Product Document Library

SEARCH
products/specs/properties

COMPILE
technical/safety data sheets

DOWNLOAD
submittals with one click

Search by the categories listed below (manufacturer, product name, etc.) for mechanical insulation information.  If you cannot find the information you need, please submit a request and we will reply with the information you need.  Click on the PDF thumbnail to download  Technical Data Sheets (TDS) and Safety Data Sheets (SDS).

Click here to watch a DOCUMENT LIBRARY TUTORIAL VIDEO.

NOTE:  You must click the filter RESET after you click a red link under the Doc Type or Product Category columns to continue Search.

Can’t find something? Send us a request and we will email it to you.

  • This field is for validation purposes and should be left unchanged.

VendorProductDoc TypeASTM / Military Spec #s Product Category DocumentsAdditional ASTM / Military Spec #shf:doc_tagshf:doc_categories
GIC, EDITABLE COVER SHEET FOR YOUR DOCUMENT SUBMISSIONSsds tds
3M3M 3015NP Air and Vapor BarrierAir Permeance of membrane: 0.0004 cfm - ASTM E2178, Air Leakage of assembled wall: 0.0021 cfm/ft2, Penetrated wall @ 75Pa (0.3 in/wg.): 0.0027 cfm/ft2. Air Leakage Rate Classification A1 - ASTM E2357. Water Vapor Transmission: Desiccant Method 0.10 US Perms. Water Method 0.09 US Perms - ASTM E96. Low Temperature Flexibility @ -30°C (-22°F) - ASTM D1970 Section 7.9. Nail Sealability 127mm (5in) water head after 3 days - ASTM D1970 Section 7.9. Surface Burning Characteristics Flame Spread Index 0 - ASTM E84. Crack Bridging - ASTM C1305. Backing Thickness 5 mils, Total Thickness (coated membrane): 10 mils - ASTM D3652. Tensile Strength (coated membrane):2153 psi, Elongation at Break: > 700% - ASTM D882. Lap Adhesion: 6.74 lbf/in - ASTM D1876. Pull Adhesion (psi/kPa) Concrete: 22 / 151, Plywood: 24 / 167, OSB: 16/111, DensGlass: 26/179 - ASTM D4541. Peel Strength (lbf/in / N/mm) Concrete: 6.40 / 1.12, Plywood: 5.31 / 0.93, OSB: 5.88/1.03, DensGlass: 5.20/0.91 - ASTM D903.ASTM E2178, ASTM E2357, ASTM E96, ASTM D1970, ASTM D1970, ASTM E84, ASTM C1305, ASTM D3652, ASTM D882, ASTM D4541, ASTM D903, ASTM E 2178, ASTM E 2357, ASTM E 96, ASTM D 1970, ASTM D 1970, ASTM E 84, ASTM C 1305, ASTM D 3652, ASTM D 882, ASTM D 4541, ASTM D 903, ASTM E-2178, ASTM E-2357, ASTM E-96, ASTM D-1970, ASTM D-1970, ASTM E-84, ASTM C-1305, ASTM D-3652, ASTM D-882, ASTM D-4541, ASTM D-903tdsair-vapor-barriers-waterproofing-systems
3M3M 3015NP Air and Vapor BarrierAir Permeance of membrane: 0.0004 cfm - ASTM E2178, Air Leakage of assembled wall: 0.0021 cfm/ft2, Penetrated wall @ 75Pa (0.3 in/wg.): 0.0027 cfm/ft2. Air Leakage Rate Classification A1 - ASTM E2357. Water Vapor Transmission: Desiccant Method 0.10 US Perms. Water Method 0.09 US Perms - ASTM E96. Low Temperature Flexibility @ -30°C (-22°F) - ASTM D1970 Section 7.9. Nail Sealability 127mm (5in) water head after 3 days - ASTM D1970 Section 7.9. Surface Burning Characteristics Flame Spread Index 0 - ASTM E84. Crack Bridging - ASTM C1305. Backing Thickness 5 mils, Total Thickness (coated membrane): 10 mils - ASTM D3652. Tensile Strength (coated membrane):2153 psi, Elongation at Break: > 700% - ASTM D882. Lap Adhesion: 6.74 lbf/in - ASTM D1876. Pull Adhesion (psi/kPa) Concrete: 22 / 151, Plywood: 24 / 167, OSB: 16/111, DensGlass: 26/179 - ASTM D4541. Peel Strength (lbf/in / N/mm) Concrete: 6.40 / 1.12, Plywood: 5.31 / 0.93, OSB: 5.88/1.03, DensGlass: 5.20/0.91 - ASTM D903.ASTM E2178, ASTM E2357, ASTM E96, ASTM D1970, ASTM D1970, ASTM E84, ASTM C1305, ASTM D3652, ASTM D882, ASTM D4541, ASTM D903, ASTM E 2178, ASTM E 2357, ASTM E 96, ASTM D 1970, ASTM D 1970, ASTM E 84, ASTM C 1305, ASTM D 3652, ASTM D 882, ASTM D 4541, ASTM D 903, ASTM E-2178, ASTM E-2357, ASTM E-96, ASTM D-1970, ASTM D-1970, ASTM E-84, ASTM C-1305, ASTM D-3652, ASTM D-882, ASTM D-4541, ASTM D-903sdsair-vapor-barriers-waterproofing-systems
3M3M Fire Barrier Duct Wrap 615+ASTM E 2336 Standard Test Methods for Fire Resistive Grease Duct Enclosure Systems ICC-ES AC101, Acceptance Criteria for Grease Duct Enclosure Assemblies ASTM E 119, Standard Test Methods for Fire Tests of Building Construction ASTM E 814, Standard Test Method for Fire Tests of Penetration Firestop Systems ASTM E 136, Standard Test Method for Behavior of Material in a Vertical Tube Furnace at 750ºC (1382°F) ASTM C 518 Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus ASTM E 84, Standard Test Method for Surface Burning Characteristics of Building Materials ISO 6944-85, Fire Resistance Tests – Ventilation Ducts. Noise Reduction Coefficient ASTM C 423: 0.80ASTM E 2336, ASTM E 119, ASTM E 814, ASTM E 136, ASTM C 518, ASTM E 84, ASTM C 423. ASTM E-2336, ASTM E-119, ASTM E-814, ASTM E-136, ASTM C-518, ASTM E-84, ASTM C-423. ASTM E2336, ASTM E119, ASTM E814, ASTM E136, ASTM C518, ASTM E84, ASTM C423.tdsfirestop
3M3M Fire Barrier Duct Wrap 615+ASTM E 2336 Standard Test Methods for Fire Resistive Grease Duct Enclosure Systems ICC-ES AC101, Acceptance Criteria for Grease Duct Enclosure Assemblies ASTM E 119, Standard Test Methods for Fire Tests of Building Construction ASTM E 814, Standard Test Method for Fire Tests of Penetration Firestop Systems ASTM E 136, Standard Test Method for Behavior of Material in a Vertical Tube Furnace at 750ºC (1382°F) ASTM C 518 Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus ASTM E 84, Standard Test Method for Surface Burning Characteristics of Building Materials ISO 6944-85, Fire Resistance Tests – Ventilation Ducts. Noise Reduction Coefficient ASTM C 423: 0.80ASTM E 2336, ASTM E 119, ASTM E 814, ASTM E 136, ASTM C 518, ASTM E 84, ASTM C 423. ASTM E-2336, ASTM E-119, ASTM E-814, ASTM E-136, ASTM C-518, ASTM E-84, ASTM C-423. ASTM E2336, ASTM E119, ASTM E814, ASTM E136, ASTM C518, ASTM E84, ASTM C423.sdsfirestop
3M3M Fire Barrier Duct Wrap 615+Asbestos : Not intentionally added. Cadmium and (Cd) Compounds : Not intentionally added. Chlorinated Polyethylene : Not intentionally added. Chlorofluorocarbons (CFCs) : Not intentionally added. Chloroprene (Neoprene) : Not intentionally added. Chlorosulfonated Polyethylene : Not intentionally added. Cobalt and (Co) Compounds : Not intentionally added. Creosote : Not intentionally added. Epoxy Compounds : Not intentionally added. Formaldehyde (CAS 50-00-0) : Not intentionally added. Lead and (Pb) Compounds : Not intentionally added. Mercury and (Hg) Compounds : Not intentionally added. Ozone Depleting Chemicals (ODCs) : Not intentionally added. Pentachlorophenol (87-86-5) : Not intentionally added. Petrochemical Fertilizers : Not intentionally added. Polybrominated Biphenyls (PBB) : Not intentionally added. Polybrominated Diphenylethers (PBDE) : Not intentionally added. Polychlorinated Biphenyls (PCBs) : Not intentionally added. Polyvinyl Chloride (PVC) : Not intentionally added. Radioactive Substance : Not intentionally added. Selenium and (Se) Compounds : Not intentionally added. Urea-Formaldehyde (UF) : Not intentionally added.leedfirestop
3M3M Fire Barrier Sealant CP 25WB+• Firestop tested up to 4 hours in accordance with ASTM E 814 (UL 1479) & CAN/ULC S115 • Fire Resistance tested for static construction joint systems in accordance with ASTM E 1966 (UL 2079) • Re-enterable / repairable • Meets UL 1479 aging requirements • Helps minimize sound transfer. Application Temperature Range (ASTM C 1299): 40° to 122°F (4° to 50°C) Service Temperature Range: -20° to 180°F (-28° to 82°C) STC (ASTM E 90 and ASTM E 413): 54 when tested in STC 54-rated wall assembly Surface Burning (ASTM E 84): Flame Spread 0, Smoke Development 0 Hardness (ASTM D 2240 Shore A): 45 Tensile Strength: 85 psi (0.59 MPa) Volume Shrinkage (ASTM C 1241): 28% VOC Less H2O and Exempt Solvents: < 1g/L.CP25, CP-25, ASTM E 814, UL1479 CAN/ULC S115, ASTM E 1966 (UL 2079), UL 1479, ASTM C 1299, ASTM E 90, ASTM E 413, ASTM E 84, ASTM D 2240 ASTM C 1241. ASTM E814, CAN/ULCS115, ASTM E1966 (UL2079), UL1479, ASTM C1299, ASTM E90, ASTM E413, ASTM E84, ASTM D2240 ASTM C1241. ASTM E-814, CAN/ULCS-115, ASTM E-1966 (UL-2079), UL-1479, ASTM C-1299, ASTM E-90, ASTM E-413, ASTM E-84, ASTM D-2240 ASTM C-1241. tdsfirestop
3M3M Fire Barrier Sealant CP 25WB+• Firestop tested up to 4 hours in accordance with ASTM E 814 (UL 1479) & CAN/ULC S115 • Fire Resistance tested for static construction joint systems in accordance with ASTM E 1966 (UL 2079) • Re-enterable / repairable • Meets UL 1479 aging requirements • Helps minimize sound transfer. Application Temperature Range (ASTM C 1299): 40° to 122°F (4° to 50°C) Service Temperature Range: -20° to 180°F (-28° to 82°C) STC (ASTM E 90 and ASTM E 413): 54 when tested in STC 54-rated wall assembly Surface Burning (ASTM E 84): Flame Spread 0, Smoke Development 0 Hardness (ASTM D 2240 Shore A): 45 Tensile Strength: 85 psi (0.59 MPa) Volume Shrinkage (ASTM C 1241): 28% VOC Less H2O and Exempt Solvents: < 1g/L.CP25, CP-25, ASTM E 814, UL1479 CAN/ULC S115, ASTM E 1966 (UL 2079), UL 1479, ASTM C 1299, ASTM E 90, ASTM E 413, ASTM E 84, ASTM D 2240 ASTM C 1241. ASTM E814, CAN/ULCS115, ASTM E1966 (UL2079), UL1479, ASTM C1299, ASTM E90, ASTM E413, ASTM E84, ASTM D2240 ASTM C1241. ASTM E-814, CAN/ULCS-115, ASTM E-1966 (UL-2079), UL-1479, ASTM C-1299, ASTM E-90, ASTM E-413, ASTM E-84, ASTM D-2240 ASTM C-1241. sdsfirestop
3M3M Fire Barrier Water Tight Sealant 1000 NSASTM E 814 (UL 1479), ASTM E 1966 (UL 2079), CAN/ ULC-S115, UL W-Rating Class 1, NEC (NFPA 70), IBC, IFC, IRC, NBCC, NFPA 101, NFPA 5000. Elongation at Break (ASTM D 412): 600%. Service Temperature Range: -60°F to 300°F (-51°C to 149°C). STC (ASTM E 90 and ASTM E 413): 56 when tested in STC 56 rated wall assembly. Surface Burning (ASTM E 84 Mod): Flame Spread 0, Smoke Development 0. Hardness (ASTM C 66 Shore A): 20–25 (1000 NS) 10–15 (1003 SL). Tensile Strength: 85 psi (0.59 MPa). VOC Less H2O and Exempt Solvents: < 250g/L. ASTM E814, ASTM E1966, ASTM D412, ASTM E90, ASTM E413, ASTM E84, ASTM C66 , ASTM E 814, ASTM E 1966, ASTM D 412, ASTM E 90, ASTM E 413, ASTM E 84, ASTM C 66 , ASTM E-814, ASTM E-1966, ASTM D-412, ASTM E-90, ASTM E-413, ASTM E-84, ASTM C-66 tdsfirestop
3M3M Fire Barrier Water Tight Sealant 1000 NSASTM E 814 (UL 1479), ASTM E 1966 (UL 2079), CAN/ ULC-S115, UL W-Rating Class 1, NEC (NFPA 70), IBC, IFC, IRC, NBCC, NFPA 101, NFPA 5000. Elongation at Break (ASTM D 412): 600%. Service Temperature Range: -60°F to 300°F (-51°C to 149°C). STC (ASTM E 90 and ASTM E 413): 56 when tested in STC 56 rated wall assembly. Surface Burning (ASTM E 84 Mod): Flame Spread 0, Smoke Development 0. Hardness (ASTM C 66 Shore A): 20–25 (1000 NS) 10–15 (1003 SL). Tensile Strength: 85 psi (0.59 MPa). VOC Less H2O and Exempt Solvents: < 250g/L. ASTM E814, ASTM E1966, ASTM D412, ASTM E90, ASTM E413, ASTM E84, ASTM C66 , ASTM E 814, ASTM E 1966, ASTM D 412, ASTM E 90, ASTM E 413, ASTM E 84, ASTM C 66 , ASTM E-814, ASTM E-1966, ASTM D-412, ASTM E-90, ASTM E-413, ASTM E-84, ASTM C-66 sdsfirestop
3M3M Fire Barrier Water Tight Sealant 1003 SLASTM E 814 (UL 1479), ASTM E 1966 (UL 2079), CAN/ ULC-S115, UL W-Rating Class 1, NEC (NFPA 70), IBC, IFC, IRC, NBCC, NFPA 101, NFPA 5000. Elongation at Break (ASTM D 412): 600%. Service Temperature Range: -60°F to 300°F (-51°C to 149°C). STC (ASTM E 90 and ASTM E 413): 56 when tested in STC 56 rated wall assembly. Surface Burning (ASTM E 84 Mod): Flame Spread 0, Smoke Development 0. Hardness (ASTM C 66 Shore A): 20–25 (1000 NS) 10–15 (1003 SL). Tensile Strength: 85 psi (0.59 MPa). VOC Less H2O and Exempt Solvents: < 250g/L. ASTM E814, ASTM E1966, ASTM D412, ASTM E90, ASTM E413, ASTM E84, ASTM C66 , ASTM E 814, ASTM E 1966, ASTM D 412, ASTM E 90, ASTM E 413, ASTM E 84, ASTM C 66 , ASTM E-814, ASTM E-1966, ASTM D-412, ASTM E-90, ASTM E-413, ASTM E-84, ASTM C-66 tdsfirestop
3M3M Fire Barrier Water Tight Sealant 1003 SLASTM E 814 (UL 1479), ASTM E 1966 (UL 2079), CAN/ ULC-S115, UL W-Rating Class 1, NEC (NFPA 70), IBC, IFC, IRC, NBCC, NFPA 101, NFPA 5000. Elongation at Break (ASTM D 412): 600%. Service Temperature Range: -60°F to 300°F (-51°C to 149°C). STC (ASTM E 90 and ASTM E 413): 56 when tested in STC 56 rated wall assembly. Surface Burning (ASTM E 84 Mod): Flame Spread 0, Smoke Development 0. Hardness (ASTM C 66 Shore A): 20–25 (1000 NS) 10–15 (1003 SL). Tensile Strength: 85 psi (0.59 MPa). VOC Less H2O and Exempt Solvents: < 250g/L. ASTM E814, ASTM E1966, ASTM D412, ASTM E90, ASTM E413, ASTM E84, ASTM C66 , ASTM E 814, ASTM E 1966, ASTM D 412, ASTM E 90, ASTM E 413, ASTM E 84, ASTM C 66 , ASTM E-814, ASTM E-1966, ASTM D-412, ASTM E-90, ASTM E-413, ASTM E-84, ASTM C-66 sdsfirestop
3M3M Fire Barrier Water Tight Sealant 3000 WTFirestop tested up to 4 hours in accordance with ASTM E 814 (UL 1479) & CAN/ULC S115 • Fire Resistance tested for static construction joint systems in accordance with ASTM E 1966 (UL 2079) • Meets UL Water Leakage Test, W Rating — Class 1 requirements. Application Temperature Range: (ASTM C 1299) -20°F to 122°F (-29°C to 50°C) Service Temperature Range: 14°F to 230°F (-10°C to 110°C) STC (ASTM E 90 and ASTM E 413): 53 when tested in STC 54 rated wall assembly Fungi Testing: Meets ASTM G 21 requirements Surface Burning (ASTM E 84 Mod): Flame Spread 0, Smoke Development 0 Working Time: 20–40 minutes Expansion Volume: > 6 times at 662°F (350°C) Specific Gravity: 1.25 VOC Less H2O and Exempt Solvents: < 31g/L.ASTM E 814, UL 1479, CAN/ULC S115, ASTM E 1966 (UL 2079), ASTM C 1299, ASTM E 90, ASTM E 413, ASTM G 21, ASTM E 84. ASTM E814, UL1479, CAN/ULC S115, ASTM E1966 (UL2079), ASTM C1299, ASTM E90, ASTM E413, ASTM G21, ASTM E84. ASTM E-814, UL-1479, CAN/ULC S-115, ASTM E-1966 (UL-2079), ASTM C-1299, ASTM E-90, ASTM E-413, ASTM G-21, ASTM E-84.tdsfirestop
3M3M Fire Barrier Water Tight Sealant 3000 WTFirestop tested up to 4 hours in accordance with ASTM E 814 (UL 1479) & CAN/ULC S115 • Fire Resistance tested for static construction joint systems in accordance with ASTM E 1966 (UL 2079) • Meets UL Water Leakage Test, W Rating — Class 1 requirements. Application Temperature Range: (ASTM C 1299) -20°F to 122°F (-29°C to 50°C) Service Temperature Range: 14°F to 230°F (-10°C to 110°C) STC (ASTM E 90 and ASTM E 413): 53 when tested in STC 54 rated wall assembly Fungi Testing: Meets ASTM G 21 requirements Surface Burning (ASTM E 84 Mod): Flame Spread 0, Smoke Development 0 Working Time: 20–40 minutes Expansion Volume: > 6 times at 662°F (350°C) Specific Gravity: 1.25 VOC Less H2O and Exempt Solvents: < 31g/L.ASTM E 814, UL 1479, CAN/ULC S115, ASTM E 1966 (UL 2079), ASTM C 1299, ASTM E 90, ASTM E 413, ASTM G 21, ASTM E 84. ASTM E814, UL1479, CAN/ULC S115, ASTM E1966 (UL2079), ASTM C1299, ASTM E90, ASTM E413, ASTM G21, ASTM E84. ASTM E-814, UL-1479, CAN/ULC S-115, ASTM E-1966 (UL-2079), ASTM C-1299, ASTM E-90, ASTM E-413, ASTM G-21, ASTM E-84.sdsfirestop
3M3M FireDam Spray 200ASTM E 84: Flame Spread <25 Smoke Developed Index <50. Up to 4-hour fire protection in construction joints per ASTM E 1966 (UL 2079) • Up to 2-hour fire protection for through penetration systems per ASTM E 814 (UL 1479) & CAN/ULC-S115 • Highly elastic material maintains performance with up to ± 50% movement capabilities Construction Joints: Has been fire tested and evaluated under the pass/fail criteria of ASTM E 1966 (UL 2079) and CAN/ULC-S115 at the maximum extended joint width. Perimeter Joints: Has been fire tested and evaluated under the pass/fail criteria of ASTM E 2307 and CAN/ULC-S115 at the maximum extended joint width. Through Penetrations: Has been fire tested and evaluated under the pass/fail criteria of ASTM E 814 (UL 1479) Standard and CAN/ULC-S115.ASTM E84, ASTM E1966, (UL 2079) ASTM E814, (UL 1479) ASTM E1966, (UL 2079) ASTM E2307, CAN/ULC-S115. ASTM E 84, ASTM E 1966, (UL2079) ASTM E 814, (UL1479) ASTM E 1966, (UL2079) ASTM E 2307, CAN/ULC S115. ASTM E-84, ASTM E-1966, (UL-2079) ASTM E-814, (UL-1479) ASTM E-1966, (UL-2079) ASTM E-2307, CAN/UL CS115. tdsfirestop
3M3M FireDam Spray 200ASTM E 84: Flame Spread <25 Smoke Developed Index <50. Up to 4-hour fire protection in construction joints per ASTM E 1966 (UL 2079) • Up to 2-hour fire protection for through penetration systems per ASTM E 814 (UL 1479) & CAN/ULC-S115 • Highly elastic material maintains performance with up to ± 50% movement capabilities Construction Joints: Has been fire tested and evaluated under the pass/fail criteria of ASTM E 1966 (UL 2079) and CAN/ULC-S115 at the maximum extended joint width. Perimeter Joints: Has been fire tested and evaluated under the pass/fail criteria of ASTM E 2307 and CAN/ULC-S115 at the maximum extended joint width. Through Penetrations: Has been fire tested and evaluated under the pass/fail criteria of ASTM E 814 (UL 1479) Standard and CAN/ULC-S115.ASTM E84, ASTM E1966, (UL 2079) ASTM E814, (UL 1479) ASTM E1966, (UL 2079) ASTM E2307, CAN/ULC-S115. ASTM E 84, ASTM E 1966, (UL2079) ASTM E 814, (UL1479) ASTM E 1966, (UL2079) ASTM E 2307, CAN/ULC S115. ASTM E-84, ASTM E-1966, (UL-2079) ASTM E-814, (UL-1479) ASTM E-1966, (UL-2079) ASTM E-2307, CAN/UL CS115. sdsfirestop
3M3M Interam Endothermic Mat E-5A-4ASTM E 84 (UL 723) Surface Burning Characteristics of Building Materials ASTM E 119 (UL 263) Fire Tests of Building Construction and Materials ASTM E 1529 (UL 1709) Determining Effects of Large Hydrocarbon Pool Fires on Structural Members and Assemblies ASTM E 1725 (UL 1724) Fire Tests of Fire-Resistive Barrier Systems for Electrical System Components ASTM E 814 (UL 1479) Standard Test Method for Fire Tests of Penetration Firestop Systems CAN/ULC-S115 Standard Method of Fire Tests of Firestop Systems. Provides up to 4 hour fire protection for structural steel applications1 in accordance with ASTM E 119 • Provides up to 3 hour fire protection for electrical circuit applications1,2 in accordance with ASTM E 1725 • Provides protection against large hydrocarbon pool fires in accordance with ASTM E 1529 (UL 1709). Surface Burning (ASTM E 84): Flame Spread 0.7, Smoke Development 0 Fuel Contribution 0. ASTM E 84 (UL 723), ASTM E 119 (UL 263), ASTM E 1529 (UL 1709), ASTM E 1725 (UL 1724), ASTM E 814 (UL 1479), CAN/ULC-S115, ASTM E 119, ASTM E 1725, ASTM E 1529 (UL 1709). ASTM E84 (UL723), ASTM E119 (UL263), ASTM E1529 (UL1709), ASTM E1725 (UL1724), ASTM E814 (UL1479), CAN/ULC S 115, ASTM E119, ASTM E1725, ASTM E1529 (UL1709). ASTM E-84 (UL-723), ASTM E-119 (UL-263), ASTM E-1529 (UL-1709), ASTM E-1725 (UL-1724), ASTM E-814 (UL-1479), CAN/ULC S-115, ASTM E119, ASTM E-1725, ASTM E-1529 (UL-1709).tdsfirestop
3M3M Interam Endothermic Mat E-5A-4ASTM E 84 (UL 723) Surface Burning Characteristics of Building Materials ASTM E 119 (UL 263) Fire Tests of Building Construction and Materials ASTM E 1529 (UL 1709) Determining Effects of Large Hydrocarbon Pool Fires on Structural Members and Assemblies ASTM E 1725 (UL 1724) Fire Tests of Fire-Resistive Barrier Systems for Electrical System Components ASTM E 814 (UL 1479) Standard Test Method for Fire Tests of Penetration Firestop Systems CAN/ULC-S115 Standard Method of Fire Tests of Firestop Systems. Provides up to 4 hour fire protection for structural steel applications1 in accordance with ASTM E 119 • Provides up to 3 hour fire protection for electrical circuit applications1,2 in accordance with ASTM E 1725 • Provides protection against large hydrocarbon pool fires in accordance with ASTM E 1529 (UL 1709). Surface Burning (ASTM E 84): Flame Spread 0.7, Smoke Development 0 Fuel Contribution 0. ASTM E 84 (UL 723), ASTM E 119 (UL 263), ASTM E 1529 (UL 1709), ASTM E 1725 (UL 1724), ASTM E 814 (UL 1479), CAN/ULC-S115, ASTM E 119, ASTM E 1725, ASTM E 1529 (UL 1709). ASTM E84 (UL723), ASTM E119 (UL263), ASTM E1529 (UL1709), ASTM E1725 (UL1724), ASTM E814 (UL1479), CAN/ULC S 115, ASTM E119, ASTM E1725, ASTM E1529 (UL1709). ASTM E-84 (UL-723), ASTM E-119 (UL-263), ASTM E-1529 (UL-1709), ASTM E-1725 (UL-1724), ASTM E-814 (UL-1479), CAN/ULC S-115, ASTM E119, ASTM E-1725, ASTM E-1529 (UL-1709).sdsfirestop
3M3M Ultra Conformable Flashing Tape 3015UC3M acrylic adhesive allows the application of 3M™ Ultra Conformable Flashing Tape 3015UC at temperatures as low as 0°F and as high as 150°F. 3M Ultra Conformable Flashing Tape 3015UC can be exposed to UV sunlight for up to 12 months. It is repositionable, yet will adhere to and accept adhesion from most common building substrates per criteria of AMAA 711-13 using test method ASTM C-794.ASTM C794, ASTM C 794, ASTM C-794tdstapes
3M3M Ultra Conformable Flashing Tape 3015UC3M acrylic adhesive allows the application of 3M™ Ultra Conformable Flashing Tape 3015UC at temperatures as low as 0°F and as high as 150°F. 3M Ultra Conformable Flashing Tape 3015UC can be exposed to UV sunlight for up to 12 months. It is repositionable, yet will adhere to and accept adhesion from most common building substrates per criteria of AMAA 711-13 using test method ASTM C-794.ASTM C794, ASTM C 794, ASTM C-794sdstapes
3M3M Venture Tape Self wound PVC Tape 1506RProduct Thickness: 6.0 mils (0.15 mm), Test Method PSTC-133 • Peel Adhesion: 29 oz/in (8.1 N/25 mm), Test Method PSTC-101 • Shear Adhesion: >24 hrs @ 2.2 psi (>24 hrs @ 15.2 kPa), Test Method PSTC-107 • Tensile Strength: 15 lb/in (67.8 N/25 mm), Test Method PSTC-131 • Elongation: 150% (150%), Test Method PSTC-131 • Service Temperature: 0° to 175°F (-18° to 79°C).PSTC133, PSTC101, PSTC107, PSTC131, PSTC131. PSTC 133, PSTC 101, PSTC 107, PSTC 131, PSTC 131. tdstapes
AlphaALPHA Maritex Style 2025/9383 Lagging FabricCoast Guard Specification 164.009. MIL-I-24244B. Military Specification MIL-C-20079H. ANSI/FM 4950. WEIGHT: ASTM-D-3776 17.8 oz/sy ± 10%, 605.2 g/m² ± 10%. THICKNESS ASTM D-1777 0.030" ± 10% 0.762 mm ± .025 mm. TENSILE STRENGTH ASTM-D-579 Warp- 250 lbs/inch 44.72 kg/cm. FLAME RESISTANCE ASTM D-6413 Char Length 1 inch max. 2.54 cm max. ENDS PER INCH ASTM-D-3775 20 (±2) x 14 (±2).MIL I24244B, MIL C20079H. ANSI/FM 4950, ASTM D3776, ASTM D579, ASTM D1777, ASTM D6413, ASTM D3775. MIL I 24244B, MIL C 20079H. ANSI/FM 4950, ASTM D 3776, ASTM D 579, ASTM D 1777, ASTM D 6413, ASTM D 3775. MIL-I-24244B, MIL-C-20079H. ANSI/FM 4950, ASTM-D-3776, ASTM-D-579, ASTM D-1777, ASTM D-6413, ASTM-D-3775.tdshigh-temperature-cloths
AlphaALPHA Maritex Style 2025/9383 Lagging FabricCoast Guard Specification 164.009. MIL-I-24244B. Military Specification MIL-C-20079H. ANSI/FM 4950. WEIGHT: ASTM-D-3776 17.8 oz/sy ± 10%, 605.2 g/m² ± 10%. THICKNESS ASTM D-1777 0.030" ± 10% 0.762 mm ± .025 mm. TENSILE STRENGTH ASTM-D-579 Warp- 250 lbs/inch 44.72 kg/cm. FLAME RESISTANCE ASTM D-6413 Char Length 1 inch max. 2.54 cm max. ENDS PER INCH ASTM-D-3775 20 (±2) x 14 (±2).MIL I24244B, MIL C20079H. ANSI/FM 4950, ASTM D3776, ASTM D579, ASTM D1777, ASTM D6413, ASTM D3775. MIL I 24244B, MIL C 20079H. ANSI/FM 4950, ASTM D 3776, ASTM D 579, ASTM D 1777, ASTM D 6413, ASTM D 3775. MIL-I-24244B, MIL-C-20079H. ANSI/FM 4950, ASTM-D-3776, ASTM-D-579, ASTM D-1777, ASTM D-6413, ASTM-D-3775.sdshigh-temperature-cloths
AlphaALPHA Maritex Style 84215/9383 Lagging FabricCoast Guard Specification 164.009. MIL-C-20079H. MIL-DTL-24244. temperature of the insulated surface is between 125 °F (52 °C) and 500 °F (260 °C). WEIGHT ASTM-D-3776 8.5 oz/sy ± 10% 289 g/m² ± 10%. THICKNESS ASTM-D-1777 0.018" ± 10% 0.457 mm ± 10%. TENSILE STRENGTH ASTM-D-579 Warp- 100 lbs/inch 17.86 kg/cm. FLAME RESISTANCE ASTM D-6413 Char Length 1 inch max. 2.54 cm max. ENDS PER INCH ASTM-D-3775 18 (±2) x 14 (±2). MIL C 20079H. MIL DTL 24244. ASTM D3776, ASTM D1777, ASTM D579, ASTM D6413, ASTM D3775.MILC20079H. MILDTL24244. ASTMD3776, ASTMD1777, ASTMD579, ASTM D6413, ASTMD3775.MIL-C-20079H. MIL-DTL-24244. ASTM-D-3776, ASTM-D-1777, ASTM-D-579, ASTM D-6413, ASTM-D-3775.tdshigh-temperature-cloths
AlphaALPHA Maritex Style 84215/9383 Lagging FabricCoast Guard Specification 164.009. MIL-C-20079H. MIL-DTL-24244. temperature of the insulated surface is between 125 °F (52 °C) and 500 °F (260 °C). WEIGHT ASTM-D-3776 8.5 oz/sy ± 10% 289 g/m² ± 10%. THICKNESS ASTM-D-1777 0.018" ± 10% 0.457 mm ± 10%. TENSILE STRENGTH ASTM-D-579 Warp- 100 lbs/inch 17.86 kg/cm. FLAME RESISTANCE ASTM D-6413 Char Length 1 inch max. 2.54 cm max. ENDS PER INCH ASTM-D-3775 18 (±2) x 14 (±2). MIL C 20079H. MIL DTL 24244. ASTM D3776, ASTM D1777, ASTM D579, ASTM D6413, ASTM D3775.MILC20079H. MILDTL24244. ASTMD3776, ASTMD1777, ASTMD579, ASTM D6413, ASTMD3775.MIL-C-20079H. MIL-DTL-24244. ASTM-D-3776, ASTM-D-1777, ASTM-D-579, ASTM D-6413, ASTM-D-3775.sdshigh-temperature-cloths
AlphaALPHA TEMP-MATMIL-1-16411 Type II, ASTM-C-1086-96, Coast Guard Specification for Incombustible Materials #164.009 and MIL-I-24244, “E” type glass fibers 9-13 microns ln diameter, Weight 3 oz./ft.2 915.6 g/m2, service T°: Up to 1200° F (649°C), Weight 6 oz./ft.2 1831.2 g/m2, service T°: Up to 1200° F (649°C). weight 9 oz./ft.2 2746.8 g/m2, service T°: Up to 1200° F (649°C), weight 15 oz./ft.2 4578 g/m2, service T°: Up to 1200° F (649°C).MIL 116411, ASTM C1086 96, MIL I24244, MIL 1 16411, ASTM C 1086 96, MIL I 24244, MIL-1-16411, ASTM-C-1086-96, MIL-I-24244.tdstemp-mat
AlphaALPHA TEMP-MATMIL-1-16411 Type II, ASTM-C-1086-96, Coast Guard Specification for Incombustible Materials #164.009 and MIL-I-24244, “E” type glass fibers 9-13 microns ln diameter, Weight 3 oz./ft.2 915.6 g/m2, service T°: Up to 1200° F (649°C), Weight 6 oz./ft.2 1831.2 g/m2, service T°: Up to 1200° F (649°C). weight 9 oz./ft.2 2746.8 g/m2, service T°: Up to 1200° F (649°C), weight 15 oz./ft.2 4578 g/m2, service T°: Up to 1200° F (649°C).MIL 116411, ASTM C1086 96, MIL I24244, MIL 1 16411, ASTM C 1086 96, MIL I 24244, MIL-1-16411, ASTM-C-1086-96, MIL-I-24244.sdstemp-mat
ArmacellArmacell ArmaGel DT Duel-Temperature Aerogel InsulationASTM C1728 compliant. ASTM C1104: Water vapour absorption, ≤ 5% by weight. ASTM C1338: Fungal resistance, No growth. ASTM E96: Water vapour transmission of integrated vapour barrier, 0.00 perm. ASTM C1617, procedure A: Corrosiveness of steel, Passed. ASTM C692, ASTM C795: Stress corrosion cracking, passed. ASTM C411: Sag resistance, ≤ 5% thickness change. ASTM C1101: Classifying the flexibility of mineral fiber blankets, Flexible. ASTM C165: Compressive strength, ≥ 5 psi/ 34.5 kPa at 10% compression. ASTM C303: Density, 185 kg/m³ 11.5 lb/ft³. ASTM E84: Surface burning characteristics, ≤ 25 flame spread index ≤ 50 smoke development. ASTM C1763: Water absorption, Maximum 8%. ASTM C356: Linear shrinkage under soaking heat, < 2% in width and length. ASTM C411: Hot surface performance, Pass. Tested according to ASTM C177. ASTM C411 and ASTM C447: Service temperature, Max. service temperature +250 °C +482 °F, Min. service temperature*1 -180/-196 °C -292/-321 °F.ASTM C1728, ASTM C1104, ASTM C1338, ASTM E96, ASTM C1617, ASTM C692, ASTM C795, ASTM C411, ASTM C1101, ASTM C165, ASTM C303, ASTM E84, ASTM C1763, ASTM C356, ASTM C411, ASTM C177, ASTM C411, ASTM C447. ASTM C 1728, ASTM C 1104, ASTM C 1338, ASTM E 96, ASTM C 1617, ASTM C 692, ASTM C 795, ASTM C 411, ASTM C 1101, ASTM C 165, ASTM C 303, ASTM E 84, ASTM C 1763, ASTM C 356, ASTM C 411, ASTM C 177, ASTM C 411, ASTM C 447. ASTM C-1728, ASTM C-1104, ASTM C-1338, ASTM E-96, ASTM C-1617, ASTM C-692, ASTM C-795, ASTM C-411, ASTM C-1101, ASTM C-165, ASTM C-303, ASTM E-84, ASTM C-1763, ASTM C-356, ASTM C-411, ASTM C-177, ASTM C-411, ASTM C-447.sdsaerogel
ArmacellArmacell ArmaGel DT Duel-Temperature Aerogel InsulationASTM C1728 compliant. ASTM C1104: Water vapour absorption, ≤ 5% by weight. ASTM C1338: Fungal resistance, No growth. ASTM E96: Water vapour transmission of integrated vapour barrier, 0.00 perm. ASTM C1617, procedure A: Corrosiveness of steel, Passed. ASTM C692, ASTM C795: Stress corrosion cracking, passed. ASTM C411: Sag resistance, ≤ 5% thickness change. ASTM C1101: Classifying the flexibility of mineral fiber blankets, Flexible. ASTM C165: Compressive strength, ≥ 5 psi/ 34.5 kPa at 10% compression. ASTM C303: Density, 185 kg/m³ 11.5 lb/ft³. ASTM E84: Surface burning characteristics, ≤ 25 flame spread index ≤ 50 smoke development. ASTM C1763: Water absorption, Maximum 8%. ASTM C356: Linear shrinkage under soaking heat, < 2% in width and length. ASTM C411: Hot surface performance, Pass. Tested according to ASTM C177. ASTM C411 and ASTM C447: Service temperature, Max. service temperature +250 °C +482 °F, Min. service temperature*1 -180/-196 °C -292/-321 °F.ASTM C1728, ASTM C1104, ASTM C1338, ASTM E96, ASTM C1617, ASTM C692, ASTM C795, ASTM C411, ASTM C1101, ASTM C165, ASTM C303, ASTM E84, ASTM C1763, ASTM C356, ASTM C411, ASTM C177, ASTM C411, ASTM C447. ASTM C 1728, ASTM C 1104, ASTM C 1338, ASTM E 96, ASTM C 1617, ASTM C 692, ASTM C 795, ASTM C 411, ASTM C 1101, ASTM C 165, ASTM C 303, ASTM E 84, ASTM C 1763, ASTM C 356, ASTM C 411, ASTM C 177, ASTM C 411, ASTM C 447. ASTM C-1728, ASTM C-1104, ASTM C-1338, ASTM E-96, ASTM C-1617, ASTM C-692, ASTM C-795, ASTM C-411, ASTM C-1101, ASTM C-165, ASTM C-303, ASTM E-84, ASTM C-1763, ASTM C-356, ASTM C-411, ASTM C-177, ASTM C-411, ASTM C-447.tdsaerogel
ArmacellArmacell ArmaGel HT High-Temperature Aerogel InsulationASTM C1728 compliant (Comprehensive Technical Overview available upon request). ASTM E84, 5/10 High temperature up to 1200°F (650°C). ASTM C1104: Water vapour absorption, ≤ 5% by weight. ASTM C1338: Fungal resistance, No growth. ASTM C1617, procedure A: Corrosiveness of steel, Passed. ASTM C692, ASTM C795: Stress corrosion cracking, passed. ASTM C411: Sag resistance, ≤ 5% thickness change. ASTM C1101: Classifying the flexibility of mineral fibre blankets, Flexible. ASTM C165: Compressive strength, >3 psi/ 20.7 kPa at 10% compression. ASTM C303: Density, 180 kg/m³ 11 lb/ft³. ASTM E84: Surface burning characteristics, < 5 flame spread index < 10 smoke development. ASTM C1763: Water absorption, Maximum 8% (before conditioning), maximum 16% (after conditioning for 24h at 316 ºC/600 ºF). ASTM C356: Linear shrinkage under soaking heat, < 2% in width and length. ASTM C411: Hot surface performance, Pass. Tested according to ASTM C177. ASTM C411 and ASTM C447: Service temperature, Max. service temperature +650 °C +1200 °F, Min. service temperature -40 °C -40 °F. ASTM C1728, ASTM E84, ASTM C1104, ASTM C1338, ASTM C1617, ASTM C692, ASTM C795, ASTM C411, ASTM C1101, ASTM C165, ASTM C303, ASTM E84, ASTM C1763, ASTM C356, ASTM C411, ASTM C177. ASTM C411, ASTM C447. ASTM C-1728, ASTM E-84, ASTM C-1104, ASTM C-1338, ASTM C-1617, ASTM C-692, ASTM C-795, ASTM C-411, ASTM C-1101, ASTM C-165, ASTM C-303, ASTM E-84, ASTM C-1763, ASTM C-356, ASTM C-411, ASTM C-177. ASTM C-411, ASTM C-447. ASTM C 1728, ASTM E 84, ASTM C 1104, ASTM C 1338, ASTM C 1617, ASTM C 692, ASTM C 795, ASTM C 411, ASTM C 1101, ASTM C 165, ASTM C 303, ASTM E 84, ASTM C 1763, ASTM C 356, ASTM C 411, ASTM C 177. ASTM C 411, ASTM C 447.tdsaerogel
ArmacellArmacell ArmaGel HT High-Temperature Aerogel InsulationASTM C1728 compliant (Comprehensive Technical Overview available upon request). ASTM E84, 5/10 High temperature up to 1200°F (650°C). ASTM C1104: Water vapour absorption, ≤ 5% by weight. ASTM C1338: Fungal resistance, No growth. ASTM C1617, procedure A: Corrosiveness of steel, Passed. ASTM C692, ASTM C795: Stress corrosion cracking, passed. ASTM C411: Sag resistance, ≤ 5% thickness change. ASTM C1101: Classifying the flexibility of mineral fibre blankets, Flexible. ASTM C165: Compressive strength, >3 psi/ 20.7 kPa at 10% compression. ASTM C303: Density, 180 kg/m³ 11 lb/ft³. ASTM E84: Surface burning characteristics, < 5 flame spread index < 10 smoke development. ASTM C1763: Water absorption, Maximum 8% (before conditioning), maximum 16% (after conditioning for 24h at 316 ºC/600 ºF). ASTM C356: Linear shrinkage under soaking heat, < 2% in width and length. ASTM C411: Hot surface performance, Pass. Tested according to ASTM C177. ASTM C411 and ASTM C447: Service temperature, Max. service temperature +650 °C +1200 °F, Min. service temperature -40 °C -40 °F. ASTM C1728, ASTM E84, ASTM C1104, ASTM C1338, ASTM C1617, ASTM C692, ASTM C795, ASTM C411, ASTM C1101, ASTM C165, ASTM C303, ASTM E84, ASTM C1763, ASTM C356, ASTM C411, ASTM C177. ASTM C411, ASTM C447. ASTM C-1728, ASTM E-84, ASTM C-1104, ASTM C-1338, ASTM C-1617, ASTM C-692, ASTM C-795, ASTM C-411, ASTM C-1101, ASTM C-165, ASTM C-303, ASTM E-84, ASTM C-1763, ASTM C-356, ASTM C-411, ASTM C-177. ASTM C-411, ASTM C-447. ASTM C 1728, ASTM E 84, ASTM C 1104, ASTM C 1338, ASTM C 1617, ASTM C 692, ASTM C 795, ASTM C 411, ASTM C 1101, ASTM C 165, ASTM C 303, ASTM E 84, ASTM C 1763, ASTM C 356, ASTM C 411, ASTM C 177. ASTM C 411, ASTM C 447.sdsaerogel
BossBoss 180 Multi Seal Insulation Anchor Pin System AdhesiveASTM C920, Type S, Grade NS, Class 25, Use G-glass, M-mortar, A-aluminum and O-other; CAN/ CGSB 19.13-M87, meets TT-S-000230C, Type II, Class A. Uncured: Specific Gravity: 1.30. Sag/Slump: Nil. Tack Free: 20-25 min. Cure Time at 75°F (24°C) and 50% RH (3/8” thick): 24 hrs. Extrusion Rate: 225 g/min. Cured-Physical: Durometer, Shore A Hardness: 35 points. Tensile Strength: 220 psi. Elongation: 400%. Service Temperature: -40°F to 325°F. Application Temperature: -35°F to 140°F.ASTM C920, ASTM C 920, ASTM C-920tdsadhesives-sealants
BossBoss 180 Multi Seal Insulation Anchor Pin System AdhesiveASTM C920, Type S, Grade NS, Class 25, Use G-glass, M-mortar, A-aluminum and O-other; CAN/ CGSB 19.13-M87, meets TT-S-000230C, Type II, Class A. Uncured: Specific Gravity: 1.30. Sag/Slump: Nil. Tack Free: 20-25 min. Cure Time at 75°F (24°C) and 50% RH (3/8” thick): 24 hrs. Extrusion Rate: 225 g/min. Cured-Physical: Durometer, Shore A Hardness: 35 points. Tensile Strength: 220 psi. Elongation: 400%. Service Temperature: -40°F to 325°F. Application Temperature: -35°F to 140°F.ASTM C920, ASTM C 920, ASTM C-920sdsadhesives-sealants
BossBoss 310 RTV Industrial Silicone SealantElongation: 425. Durometer, Shore A: 20 Tensile Strength: 330 psi. Movement Capacity: ±25%. Extrusion Rate: 425 gr/min. VOC 29 grams/liter. Service Temperature: -40°F to 400°F. Application Temperature: -35° to 140°F. TT-S-001543A (silicone building sealant) • TT-S-00230C (one component building sealant) • ASTM C-920-86 Cured sealant stays rubbery from -60°F to 400°F.ASTM C920, ASTM C 920, ASTM C-920tdsadhesives-sealants
BossBoss 310 RTV Industrial Silicone SealantElongation: 425. Durometer, Shore A: 20 Tensile Strength: 330 psi. Movement Capacity: ±25%. Extrusion Rate: 425 gr/min. VOC 29 grams/liter. Service Temperature: -40°F to 400°F. Application Temperature: -35° to 140°F. TT-S-001543A (silicone building sealant) • TT-S-00230C (one component building sealant) • ASTM C-920-86 Cured sealant stays rubbery from -60°F to 400°F.ASTM C920, ASTM C 920, ASTM C-920sdsadhesives-sealants
BossBoss 380 Contractors Silicone SealantElongation: 510. Durometer, Shore A: 19. Tensile Strength: 300 psi. Movement Capability: ±25%. Service Temperature: -40° to 400°F. Application Temperature: -35°F to 140°F. • TT-S-001543A (silicone building sealant) • TT-S-00230C (one component building sealant) • ASTM C-920-86 Cured sealant stays rubbery from -60°F to 400°F.ASTM C920, ASTM C 920, ASTM C-920tdsadhesives-sealants
BossBoss 380 Contractors Silicone SealantElongation: 510. Durometer, Shore A: 19. Tensile Strength: 300 psi. Movement Capability: ±25%. Service Temperature: -40° to 400°F. Application Temperature: -35°F to 140°F. • TT-S-001543A (silicone building sealant) • TT-S-00230C (one component building sealant) • ASTM C-920-86 Cured sealant stays rubbery from -60°F to 400°F.ASTM C920, ASTM C 920, ASTM C-920sdsadhesives-sealants
BossBoss 387 Universal Silicone SealantEase of use, one-part sealant, no mixing required. Good weatherability - virtually unaffected by sunlight, rain, snow, ozone, and temperature extremes. Long life reliability, cured sealant stays rubbery from -60°F to 400°F without tearing, cracking, drying out, or becoming brittle. Wide temperature gunnability can be applied in any seasontdsadhesives-sealants
BossBoss 387 Universal Silicone SealantEase of use, one-part sealant, no mixing required. Good weatherability - virtually unaffected by sunlight, rain, snow, ozone, and temperature extremes. Long life reliability, cured sealant stays rubbery from -60°F to 400°F without tearing, cracking, drying out, or becoming brittle. Wide temperature gunnability can be applied in any seasonsdsadhesives-sealants
BossBoss 635 Contact / Spray AdhesiveVOC Compliant. Nonchlorinated. Fast drying. High strength. Web spray. Formulated with high solidstdsadhesives-sealants
BossBoss 635 Contact / Spray AdhesiveVOC Compliant. Nonchlorinated. Fast drying. High strength. Web spray. Formulated with high solidssdsadhesives-sealants
Johns ManvilleCalcium Silicate Block InsulationASTM C165 Compressive Strength@5% Deformation: >100 psi (>690 kPa). ASTM C203 Flexural Strength: > 50 psi (>345 kPa). ASTM C447 Maximum Recommended Continuous Service Temperature: 1700°F (927°C). ASTM C533 Type II Density (Average): 18 pcf (288 kg/m3). ASTM C533 Material Specification: Type II. ASTM C795/C871/C692 Corrosion: Austenitic Stainless Steel: Passes. ASTM E84 FlameSpread/Smoke Developed: 0/0. ASTM E136 Non-Combustible: Passes. Moisture Content, Normal Percentage of Dry Weight: 4. MIL-I-2819: Class 3ASTM C165, ASTM C203, ASTM C447, ASTM C533, ASTM C533, ASTM C795, ASTM C871, ASTM C692, ASTM E84, ASTM E136, ASTM C 165, ASTM C 203, ASTM C 447, ASTM C 533, ASTM C 533, ASTM C 795, ASTM C 871, ASTM C 692, ASTM E 84, ASTM E 136, ASTM C-165, ASTM C-203, ASTM C-447, ASTM C-533, ASTM C-533, ASTM C-795, ASTM C-871, ASTM C-692, ASTM E-84, ASTM E-136tdsblock-insulation
Johns ManvilleCalcium Silicate Block InsulationASTM C165 Compressive Strength@5% Deformation: >100 psi (>690 kPa). ASTM C203 Flexural Strength: > 50 psi (>345 kPa). ASTM C447 Maximum Recommended Continuous Service Temperature: 1700°F (927°C). ASTM C533 Type II Density (Average): 18 pcf (288 kg/m3). ASTM C533 Material Specification: Type II. ASTM C795/C871/C692 Corrosion: Austenitic Stainless Steel: Passes. ASTM E84 FlameSpread/Smoke Developed: 0/0. ASTM E136 Non-Combustible: Passes. Moisture Content, Normal Percentage of Dry Weight: 4. MIL-I-2819: Class 3ASTM C165, ASTM C203, ASTM C447, ASTM C533, ASTM C533, ASTM C795, ASTM C871, ASTM C692, ASTM E84, ASTM E136, ASTM C 165, ASTM C 203, ASTM C 447, ASTM C 533, ASTM C 533, ASTM C 795, ASTM C 871, ASTM C 692, ASTM E 84, ASTM E 136, ASTM C-165, ASTM C-203, ASTM C-447, ASTM C-533, ASTM C-533, ASTM C-795, ASTM C-871, ASTM C-692, ASTM E-84, ASTM E-136sdsblock-insulation
Johns ManvilleCalcium Silicate FittingsASTM C165 Compressive Strength: >100psi(690kPa) 5% compression. ASTM C203 Flexural Strength: >50psi(450kPa). ASTM C302 Density (Dry) Average: >14pcf(230kg/m3 ). ASTM C356 Linear Shrinkage: <2.0% after 24hr Soaking period at 1200°F(650°C). ASTM C421 Abrasion Resistance Weight Loss by Tumbling After the first 10min: <20% After the second 10min <40%. ASTM C447 Maximum Service Temperature: 1200°F(650°C). ASTM C533, Type I Material Specification: Passes. ASTM C665 Corrosivity to Steel: Passes-Inhibits. ASTM C795/C871/C692 Corrosion: Passes-Inhibits. ASTM C1338 Fungi Resistant: Passes. ASTM C1617 Corrosion: Passes-Inhibits. ASTM E84 Surface Burning Characteristics: Flame Spread -0 Smoke Developed -0. ASTM E119 Building Fire Test: Passes. ASTM E136 Non Combustibility: Passes. BS 476 PART II: Passes. Can/ULC S-102 Surface Burning Characteristics: Flame Spread -0 Smoke Developed -0. City of New York MEA: 436-88-M. ISO 8143 Material Specification: Passes. MIL-I-24244 Military Specification: Passes. MIL-I-2781F to 1200°F(650°C) [Pipe] Military Specification: Passes. MIL-I-2819F Class 2 to 1200°F(650°C) [Block] Military Specification: Passes. NRC Reg. Guide 1.36: Passes. NFPA 255 Surface Burning Characteristics: Flame Spread -0 Smoke Developed -0. UL 1709 Hydrocarbon Fire Test: Rated (See IIG document TB005).ASTM C177, ASTM C518 and ASTM C335ASTM C165, ASTM C203, ASTM C302, ASTM C356, ASTM C421, ASTM C447, ASTM C533, ASTM C665, ASTM C795, ASTM C871, ASTM C692, ASTM C1338, ASTM C1617, ASTM E84, ASTM E119, ASTM E136, ASTM C 165, ASTM C 203, ASTM C 302, ASTM C 356, ASTM C 421, ASTM C 447, ASTM C 533, ASTM C 665, ASTM C 795, ASTM C 871, ASTM C 692, ASTM C 1338, ASTM C 1617, ASTM E 84, ASTM E 119, ASTM E 136, ASTM C-165, ASTM C-203, ASTM C-302, ASTM C-356, ASTM C-421, ASTM C-447, ASTM C-533, ASTM C-665, ASTM C-795, ASTM C-871, ASTM C-692, ASTM C-1338, ASTM C-1617, ASTM E-84, ASTM E-119, ASTM E-136tdsfittings
Johns ManvilleCalcium Silicate FittingsASTM C165 Compressive Strength: >100psi(690kPa) 5% compression. ASTM C203 Flexural Strength: >50psi(450kPa). ASTM C302 Density (Dry) Average: >14pcf(230kg/m3 ). ASTM C356 Linear Shrinkage: <2.0% after 24hr Soaking period at 1200°F(650°C). ASTM C421 Abrasion Resistance Weight Loss by Tumbling After the first 10min: <20% After the second 10min <40%. ASTM C447 Maximum Service Temperature: 1200°F(650°C). ASTM C533, Type I Material Specification: Passes. ASTM C665 Corrosivity to Steel: Passes-Inhibits. ASTM C795/C871/C692 Corrosion: Passes-Inhibits. ASTM C1338 Fungi Resistant: Passes. ASTM C1617 Corrosion: Passes-Inhibits. ASTM E84 Surface Burning Characteristics: Flame Spread -0 Smoke Developed -0. ASTM E119 Building Fire Test: Passes. ASTM E136 Non Combustibility: Passes. BS 476 PART II: Passes. Can/ULC S-102 Surface Burning Characteristics: Flame Spread -0 Smoke Developed -0. City of New York MEA: 436-88-M. ISO 8143 Material Specification: Passes. MIL-I-24244 Military Specification: Passes. MIL-I-2781F to 1200°F(650°C) [Pipe] Military Specification: Passes. MIL-I-2819F Class 2 to 1200°F(650°C) [Block] Military Specification: Passes. NRC Reg. Guide 1.36: Passes. NFPA 255 Surface Burning Characteristics: Flame Spread -0 Smoke Developed -0. UL 1709 Hydrocarbon Fire Test: Rated (See IIG document TB005). ASTM C177, ASTM C518 and ASTM C335ASTM C165, ASTM C203, ASTM C302, ASTM C356, ASTM C421, ASTM C447, ASTM C533, ASTM C665, ASTM C795, ASTM C871, ASTM C692, ASTM C1338, ASTM C1617, ASTM E84, ASTM E119, ASTM E136, ASTM C 165, ASTM C 203, ASTM C 302, ASTM C 356, ASTM C 421, ASTM C 447, ASTM C 533, ASTM C 665, ASTM C 795, ASTM C 871, ASTM C 692, ASTM C 1338, ASTM C 1617, ASTM E 84, ASTM E 119, ASTM E 136, ASTM C-165, ASTM C-203, ASTM C-302, ASTM C-356, ASTM C-421, ASTM C-447, ASTM C-533, ASTM C-665, ASTM C-795, ASTM C-871, ASTM C-692, ASTM C-1338, ASTM C-1617, ASTM E-84, ASTM E-119, ASTM E-136sdsfittings
Johns ManvilleCalcium Silicate Pipe CoveringASTM C165 Compressive Strength >100psi(690kPa) 5% compression ASTM C203 Flexural Strength >50psi(450kPa) ASTM C302 Density (Dry) Average >14pcf(230kg/m3 ) ASTM C356 Linear Shrinkage <2.0% after 24hr Soaking period at 1200°F(650°C) ASTM C421 Abrasion Resistance Weight Loss by Tumbling After the first 10min <20% After the second 10min <40% ASTM C447 Maximum Service Temperature 1200°F(650°C) ASTM C533, Type I Material Specification Passes ASTM C665 Corrosivity to Steel Passes-Inhibits ASTM C795/C871/C692 Corrosion Passes-Inhibits ASTM C1338 Fungi Resistant Passes ASTM C1617 Corrosion Passes-Inhibits ASTM E84 Surface Burning Characteristics Flame Spread -0 Smoke Developed -0 ASTM E119 Building Fire Test Passes ASTM E136 Non Combustibility Passes BS 476 PART II Passes Can/ULC S-102 Surface Burning Characteristics Flame Spread -0 Smoke Developed -0 City of New York MEA 436-88-M ISO 8143 Material Specification Passes MIL-I-24244 Military Specification Passes MIL-I-2781F to 1200°F(650°C) [Pipe] Military Specification Passes MIL-I-2819F Class 2 to 1200°F(650°C) [Block] Military Specification Passes NRC Reg. Guide 1.36 Passes NFPA 255 Surface Burning Characteristics Flame Spread -0 Smoke Developed -0 UL 1709 Hydrocarbon Fire Test Rated (See IIG document TB005). ASTM C177, ASTM C518 and ASTM C335.ASTM C165, ASTM C203, ASTM C302, ASTM C356, ASTM C421, ASTM C447, ASTM C533, ASTM C665, ASTM C795, ASTM C871, ASTM C692, ASTM C1338, ASTM C1617, ASTM E84, ASTM E119, ASTM E136, ASTM C 165, ASTM C 203, ASTM C 302, ASTM C 356, ASTM C 421, ASTM C 447, ASTM C 533, ASTM C 665, ASTM C 795, ASTM C 871, ASTM C 692, ASTM C 1338, ASTM C 1617, ASTM E 84, ASTM E 119, ASTM E 136, ASTM C-165, ASTM C-203, ASTM C-302, ASTM C-356, ASTM C-421, ASTM C-447, ASTM C-533, ASTM C-665, ASTM C-795, ASTM C-871, ASTM C-692, ASTM C-1338, ASTM C-1617, ASTM E-84, ASTM E-119, ASTM E-136tdspipe-insulation
Johns ManvilleCalcium Silicate Pipe CoveringASTM C165 Compressive Strength >100psi(690kPa) 5% compression ASTM C203 Flexural Strength >50psi(450kPa) ASTM C302 Density (Dry) Average >14pcf(230kg/m3 ) ASTM C356 Linear Shrinkage <2.0% after 24hr Soaking period at 1200°F(650°C) ASTM C421 Abrasion Resistance Weight Loss by Tumbling After the first 10min <20% After the second 10min <40% ASTM C447 Maximum Service Temperature 1200°F(650°C) ASTM C533, Type I Material Specification Passes ASTM C665 Corrosivity to Steel Passes-Inhibits ASTM C795/C871/C692 Corrosion Passes-Inhibits ASTM C1338 Fungi Resistant Passes ASTM C1617 Corrosion Passes-Inhibits ASTM E84 Surface Burning Characteristics Flame Spread -0 Smoke Developed -0 ASTM E119 Building Fire Test Passes ASTM E136 Non Combustibility Passes BS 476 PART II Passes Can/ULC S-102 Surface Burning Characteristics Flame Spread -0 Smoke Developed -0 City of New York MEA 436-88-M ISO 8143 Material Specification Passes MIL-I-24244 Military Specification Passes MIL-I-2781F to 1200°F(650°C) [Pipe] Military Specification Passes MIL-I-2819F Class 2 to 1200°F(650°C) [Block] Military Specification Passes NRC Reg. Guide 1.36 Passes NFPA 255 Surface Burning Characteristics Flame Spread -0 Smoke Developed -0 UL 1709 Hydrocarbon Fire Test Rated (See IIG document TB005). ASTM C177, ASTM C518 and ASTM C335.ASTM C165, ASTM C203, ASTM C302, ASTM C356, ASTM C421, ASTM C447, ASTM C533, ASTM C665, ASTM C795, ASTM C871, ASTM C692, ASTM C1338, ASTM C1617, ASTM E84, ASTM E119, ASTM E136, ASTM C 165, ASTM C 203, ASTM C 302, ASTM C 356, ASTM C 421, ASTM C 447, ASTM C 533, ASTM C 665, ASTM C 795, ASTM C 871, ASTM C 692, ASTM C 1338, ASTM C 1617, ASTM E 84, ASTM E 119, ASTM E 136, ASTM C-165, ASTM C-203, ASTM C-302, ASTM C-356, ASTM C-421, ASTM C-447, ASTM C-533, ASTM C-665, ASTM C-795, ASTM C-871, ASTM C-692, ASTM C-1338, ASTM C-1617, ASTM E-84, ASTM E-119, ASTM E-136sdspipe-insulation
CarbolineCarboline A/D Firefilm III Fireproofing•ASTM D2240 Hardness Shore D 65-70 (fully cured) Shore D 60 (for top coating) •ASTM D2794 Impact 152 inch-lbs (1.75 kg-m) •ASTM D4060 Abrasion 103 mg loss @ 1,000 cycles •ASTM D4541 Bond Strength 550 psi (3.79 MPa) •ASTM D4541 Bond Strength Typical Field Value 200 psi (1.38 MPa) •ASTM E761 Compressive Strength 757 psi (5.2 MPa) •ASTM E84 Surface Burning Class A Density 89 pcf (1,425 kg/m³)•ASTM D2240 •ASTM D2794 •ASTM D4060 •ASTM D4541 •ASTM D4541 •ASTM E761 •ASTM E84. •ASTM D 2240 •ASTM D 2794 •ASTM D 4060 •ASTM D 4541 •ASTM D 4541 •ASTM E 761 •ASTM E 84. •ASTM D-2240 •ASTM D-2794 •ASTM D-4060 •ASTM D-4541 •ASTM D-4541 •ASTM E-761 •ASTM E-84.sdsfirestop
CarbolineCarboline A/D Firefilm III Fireproofing•ASTM D2240 Hardness Shore D 65-70 (fully cured) Shore D 60 (for top coating) •ASTM D2794 Impact 152 inch-lbs (1.75 kg-m) •ASTM D4060 Abrasion 103 mg loss @ 1,000 cycles •ASTM D4541 Bond Strength 550 psi (3.79 MPa) •ASTM D4541 Bond Strength Typical Field Value 200 psi (1.38 MPa) •ASTM E761 Compressive Strength 757 psi (5.2 MPa) •ASTM E84 Surface Burning Class A Density 89 pcf (1,425 kg/m³)•ASTM D2240 •ASTM D2794 •ASTM D4060 •ASTM D4541 •ASTM D4541 •ASTM E761 •ASTM E84. •ASTM D 2240 •ASTM D 2794 •ASTM D 4060 •ASTM D 4541 •ASTM D 4541 •ASTM E 761 •ASTM E 84. •ASTM D-2240 •ASTM D-2794 •ASTM D-4060 •ASTM D-4541 •ASTM D-4541 •ASTM E-761 •ASTM E-84.tdsfirestop
CarbolineCarboline A/D TC-55 Sealer Fireproofing•ASTM E84 Surface Burning TC-55 Class A •Density TC-55 68 pcf •Film Clarity TC-55 Very Good •Film Gloss TC-55 Very Good •Film Hardness TC-55 Soft and flexible •Free Monomer TC-55 0.5% maximum •Freeze/Thaw Stability TC-55 Very Good •Particle Size TC-55 0.2-0.5 microns •pH @77°F (25°C) TC-55 4.0-5.0•ASTM E84 •ASTM E-84 •ASTM E 84 tdsfirestop
CarbolineCarboline A/D TC-55 Sealer Fireproofing•ASTM E84 Surface Burning TC-55 Class A •Density TC-55 68 pcf •Film Clarity TC-55 Very Good •Film Gloss TC-55 Very Good •Film Hardness TC-55 Soft and flexible •Free Monomer TC-55 0.5% maximum •Freeze/Thaw Stability TC-55 Very Good •Particle Size TC-55 0.2-0.5 microns •pH @77°F (25°C) TC-55 4.0-5.0•ASTM E84 •ASTM E-84 •ASTM E 84 sdsfirestop
CarbolineCarboline Accelerator A-20 FireproofingPackaging 50 lbs. bags Shelf Life 24 months Storage Material should be kept dry, covered, and off the ground between -20°F to 150°F (-29°C to 66°C). Shipping Weight (Approximate) Bag Weight is 50 lbs (22.7 kg)tdsfirestop
CarbolineCarboline Accelerator A-20 FireproofingPackaging 50 lbs. bags Shelf Life 24 months Storage Material should be kept dry, covered, and off the ground between -20°F to 150°F (-29°C to 66°C). Shipping Weight (Approximate) Bag Weight is 50 lbs (22.7 kg)sdsfirestop
CarbolineCarboline Carbocrylic 3359 Primer/TopCoat FireproofingASTM B117 Salt Fog Blasted Steel 1 ct. IOZ 1 ct. 3359 No blistering, rusting or rust creepage at scribe after 1500 hours ASTM D1653 Water Vapor Transmission 1 ct. 3359 Water Vapor Permeance (WVP) of 3.94 U.S. Perms ASTM D3359 Adhesion Blasted Steel 1 ct 3358 1 ct 3359 5A ASTM D3363 Pencil Hardness 1 ct. Acrylic Pr. 2 cts. 3359 5B ASTM D4060 Abrasion 1 ct. Acrylic Pr. 2 cts. 3359 185 mg. loss. 3000 cycles, CS10 Wheel ASTM D4213 Scrub Resistance 1 ct. 3359 .0235/.0655 Microliters per 100 cycles Wet/Dry Film Volume ASTM D4541 Adhesion Stainless Steel 1 ct 3359 1675 psi (Elcometer) ASTM E84 Flame and Smoke 1 ct 3358 1 ct. 3359 Flame 10 Smoke 20 Class A. ASTM D3359.ASTM B117, ASTM D1653, ASTM D3359, ASTM D3363, ASTM D4060, ASTM D4213, ASTM D4541, ASTM E84, ASTM B 117, ASTM D 1653, ASTM D 3359, ASTM D 3363, ASTM D 4060, ASTM D 4213, ASTM D 4541, ASTM E 84, ASTM B-117, ASTM D-1653, ASTM D-3359, ASTM D-3363, ASTM D-4060, ASTM D-4213, ASTM D-4541, ASTM E-84sdsfirestop
CarbolineCarboline Carbocrylic 3359 Primer/TopCoat FireproofingASTM B117 Salt Fog Blasted Steel 1 ct. IOZ 1 ct. 3359 No blistering, rusting or rust creepage at scribe after 1500 hours ASTM D1653 Water Vapor Transmission 1 ct. 3359 Water Vapor Permeance (WVP) of 3.94 U.S. Perms ASTM D3359 Adhesion Blasted Steel 1 ct 3358 1 ct 3359 5A ASTM D3363 Pencil Hardness 1 ct. Acrylic Pr. 2 cts. 3359 5B ASTM D4060 Abrasion 1 ct. Acrylic Pr. 2 cts. 3359 185 mg. loss. 3000 cycles, CS10 Wheel ASTM D4213 Scrub Resistance 1 ct. 3359 .0235/.0655 Microliters per 100 cycles Wet/Dry Film Volume ASTM D4541 Adhesion Stainless Steel 1 ct 3359 1675 psi (Elcometer) ASTM E84 Flame and Smoke 1 ct 3358 1 ct. 3359 Flame 10 Smoke 20 Class A. ASTM D3359.ASTM B117, ASTM D1653, ASTM D3359, ASTM D3363, ASTM D4060, ASTM D4213, ASTM D4541, ASTM E84, ASTM B 117, ASTM D 1653, ASTM D 3359, ASTM D 3363, ASTM D 4060, ASTM D 4213, ASTM D 4541, ASTM E 84, ASTM B-117, ASTM D-1653, ASTM D-3359, ASTM D-3363, ASTM D-4060, ASTM D-4213, ASTM D-4541, ASTM E-84tdsfirestop
CarbolineCarboline Southwest Type DK3 FireproofingTest for thickness and density in accordance with the applicable building code, AWCI Technical Manual 12-A (Standard Practice for the Testing and Inspection of Field Applied Sprayed FireResistive Materials, an Annotated Guide), and ASTM E605 (Standard Test Methods for Thickness and Density of Sprayed Fire-Resistive Materials Applied to Structural Members).ASTM E605. ASTM E 605. ASTM E-605.tdsfirestop
CarbolineCarboline Southwest Type DK3 FireproofingTest for thickness and density in accordance with the applicable building code, AWCI Technical Manual 12-A (Standard Practice for the Testing and Inspection of Field Applied Sprayed Fire Resistive Materials, an Annotated Guide), and ASTM E605 (Standard Test Methods for Thickness and Density of Sprayed Fire-Resistive Materials Applied to Structural Members).ASTM E605. ASTM E 605. ASTM E-605.sdsfirestop
ChildersChilders CP-35 CHIL-PERM Water-Based Vapor Retardant Coating, VOC (grams/liter less water)*: 36 g/l VOC Emissions TVOC Range**: 28µg/m³ Classroom – 67µg/m³ Private Office Water (weight %): 25.9% Solids (weight %): 73% Product Specific Gravity (ASTM D1475): 1.5 Product Weight per Gallon (ASTM D792): 12.1 lbs/gal. LEED v4: TVOC <0.5 mg/m³ (500 µg/m³). Requirements: VOC emissions: Building products must be tested and determined compliant in accordance with California Department of Public Health (CDPH) Standard Method v1.1–2010 /1.2. VOC Content: SCAQMD Rule 1113 Interior Coatings: Non-Flat*: 50 g/l, less water and exempts Flat*: 50 g/l, less water and exempts.CP 35. ASTM D 1475, ASTM D-1475. ASTM D 792, ASTM D-792.leed vocmastics-coating
ChildersChilders AK-CRYL CP-9 Weather Barrier CoatingASTM E-84, LEED IEQ 4.2 Low-Emitting Materials, NFPA Standard 90-A and 90-B 25/50. WATER VAPOR PERMEANCE ASTM E-96 Greater than 1.0 perms (Procedure B) at 1/16” film thickness. COLORS White Other colors available on special order WET WEIGHT 11.3 lbs./U.S. gal. (1.35 kg/liter) AVERAGE NON-VOLATILE 51% by volume (64% by weight) SERVICE TEMPERATURE RANGE (Temperature to which dry coating is subjected.) -40ºF to 180ºF (-40ºC to 83ºC) APPLICATION TEMPERATURE RANGE 40ºF to 100ºF (4ºC to 38ºC) DRYING TIME Touch - 2-4 hours Through - 24-36 hours (Drying time will vary depending upon film thickness, temperature and humidity.) COVERAGE 6 U.S. gal./100 sq. ft. (2.4 l/sq.m) (Varies with substrate and membrane.) CLEAN-UP Warm, soapy water (wet), xylol (dry).ASTM E84, ASTM E 84, ASTM E-84, CP9tdsmastics-coating
ChildersChilders AK-CRYL CP-9 Weather Barrier CoatingASTM E-84, LEED IEQ 4.2 Low-Emitting Materials, NFPA Standard 90-A and 90-B 25/50. WATER VAPOR PERMEANCE ASTM E-96 Greater than 1.0 perms (Procedure B) at 1/16” film thickness. COLORS White Other colors available on special order WET WEIGHT 11.3 lbs./U.S. gal. (1.35 kg/liter) AVERAGE NON-VOLATILE 51% by volume (64% by weight) SERVICE TEMPERATURE RANGE (Temperature to which dry coating is subjected.) -40ºF to 180ºF (-40ºC to 83ºC) APPLICATION TEMPERATURE RANGE 40ºF to 100ºF (4ºC to 38ºC) DRYING TIME Touch - 2-4 hours Through - 24-36 hours (Drying time will vary depending upon film thickness, temperature and humidity.) COVERAGE 6 U.S. gal./100 sq. ft. (2.4 l/sq.m) (Varies with substrate and membrane.) CLEAN-UP Warm, soapy water (wet), xylol (dry).ASTM E84, ASTM E 84, ASTM E-84, CP9sdsmastics-coating
ChildersChilders CHIL-BYL CP-76 SealantASTM E-84, SERVICE TEMPERATURE RANGE (Temperature to which dry film is subjected.) -100ºF to 300ºF -73ºC to 149ºC, ASTM F-1249, 0.038 perm (0.025 metric perm) tested in 0.047” ( 1.3 mm) dry film at 100o F (38o C) and 90%RH, ASTM E-84, Tunnel Test) CP-76 contains no asbestos, lead, mercury, or mercury compounds. 1008 Flame Spread: 5 Smoke Developed: 5 Surface Inorganic reinforced cement board Total Coverage 32 sq. ft./gal, 2” wide strip.ASTM F1249, ASTM E84, ASTM F 1249, ASTM E 84, ASTM F-1249, ASTM E-84, CP76tdsmastics-coating
ChildersChilders CHIL-BYL CP-76 SealantASTM E-84, SERVICE TEMPERATURE RANGE (Temperature to which dry film is subjected.) -100ºF to 300ºF -73ºC to 149ºC, ASTM F-1249, 0.038 perm (0.025 metric perm) tested in 0.047” ( 1.3 mm) dry film at 100o F (38o C) and 90%RH, ASTM E-84, Tunnel Test) CP-76 contains no asbestos, lead, mercury, or mercury compounds. 1008 Flame Spread: 5 Smoke Developed: 5 Surface Inorganic reinforced cement board Total Coverage 32 sq. ft./gal, 2” wide strip.ASTM F1249, ASTM E84, ASTM F 1249, ASTM E 84, ASTM F-1249, ASTM E-84, CP76sdsmastics-coating
ChildersChilders CHIL-PERM CP-30 LO Low Odor Vapor Barrier CoatingASTM E-84, NFPA Standard 90-A and 90-B 25/50, COLOR White (Other colors are available on special order.) WET WEIGHT 9.9 lbs./U.S. gal. 1.19 kg/liter AVERAGE NON-VOLATILE 39% by volume. 59% by weight. SERVICE TEMPERATURE RANGE (Temperature to which dry film is subjected.) -40ºF to 190ºF -40ºC to 88ºC APPLICATION TEMPERATURE RANGE 40ºF to 100ºF 4ºC to 38ºC DRYING TIME To Touch–8 hours Through–24-36 hours (Drying time will vary depending upon film thickness, temperature and humidity.) FLASH POINT 107ºF (42ºC) COVERAGE 4 U.S. Gals./100 sq. ft. (1.6 l/sq. m) (Varies with substrate and reinforcing membrane.) CLEAN-UP Non-flammable–Chlorinated Solvents Flammable–Xylene WATER VAPOR PERMEANCE (ASTM E-96) ASTM E-96 Procedure B, Less than 0.02 perms at 0.02 inch film thickness.ASTM E84, ASTM E96, ASTM E 84, ASTM E 96, ASTM E-84, ASTM E-96, CP30tdsmastics-coating
ChildersChilders CHIL-PERM CP-30 LO Low Odor Vapor Barrier CoatingASTM E-84, NFPA Standard 90-A and 90-B 25/50, COLOR White (Other colors are available on special order.) WET WEIGHT 9.9 lbs./U.S. gal. 1.19 kg/liter AVERAGE NON-VOLATILE 39% by volume. 59% by weight. SERVICE TEMPERATURE RANGE (Temperature to which dry film is subjected.) -40ºF to 190ºF -40ºC to 88ºC APPLICATION TEMPERATURE RANGE 40ºF to 100ºF 4ºC to 38ºC DRYING TIME To Touch–8 hours Through–24-36 hours (Drying time will vary depending upon film thickness, temperature and humidity.) FLASH POINT 107ºF (42ºC) COVERAGE 4 U.S. Gals./100 sq. ft. (1.6 l/sq. m) (Varies with substrate and reinforcing membrane.) CLEAN-UP Non-flammable–Chlorinated Solvents Flammable–Xylene WATER VAPOR PERMEANCE (ASTM E-96) ASTM E-96 Procedure B, Less than 0.02 perms at 0.02 inch film thickness.ASTM E84, ASTM E96, ASTM E 84, ASTM E 96, ASTM E-84, ASTM E-96, CP30sdsmastics-coating
ChildersChilders CP-34 Vapor Retardant CoatingASTM E-84, NFPA Standard 90-A and 90-B 25/50, COLOR White WET WEIGHT (ASTM D1475) 11.5 lbs. 1.38 kg/liter AVERAGE NON-VOLATILE (ASTM D1644) 48% by volume (62% by weight) SERVICE TEMPERATURE LIMITS (FSTM 70) (Temperature at coated surface.) -20°F to 180°F -29°C to 82°C DRYING TIME (23°C) 50% RH (ASTM D1640) To Touch – 4 hours Through – 24 hours COVERAGE (FSTM 71) 4 gallons/100 sq. ft. (1.6 l/sq. m) .064 in. wet thickness (1.6 mm). (Subject to the surface being coated.) Wet coverages are for smooth non-porous surfaces. Porous or rough surfaces will require higher gallonage to attain required dry thickness. WATER VAPOR PERMEANCE ASTM F 1249, 0.08 perms at 45 mils dry. Tested at 100°F (38°C) and 50% RH. WET FLAMMABILITY (ASTM D3278) Flash Point: None to boiling, 212°F (100°C) SURFACE BURNING CHARACTERISTICS (ASTM E-84) Flame Spread: 5 Smoke Developed: 30 Surface: Inorganic reinforced cement board Number of Coats: 1 Coverage: 25 sq. ft/gal. (Applied in a 4 inch wide strip) Flash Point of liquid coating, closed cup: No flash to boiling.ASTM E84, ASTM D1475, ASTM D1644, ASTM D1640, ASTM D3278, ASTM E 84, ASTM D 1475, ASTM D 1644, ASTM D 1640, ASTM D 3278, ASTM E-84, ASTM D-1475, ASTM D-1644, ASTM D-1640, ASTM D-3278, CP34tdsmastics-coating
ChildersChilders CP-34 Vapor Retardant CoatingASTM E-84, NFPA Standard 90-A and 90-B 25/50, COLOR White WET WEIGHT (ASTM D1475) 11.5 lbs. 1.38 kg/liter AVERAGE NON-VOLATILE (ASTM D1644) 48% by volume (62% by weight) SERVICE TEMPERATURE LIMITS (FSTM 70) (Temperature at coated surface.) -20°F to 180°F -29°C to 82°C DRYING TIME (23°C) 50% RH (ASTM D1640) To Touch – 4 hours Through – 24 hours COVERAGE (FSTM 71) 4 gallons/100 sq. ft. (1.6 l/sq. m) .064 in. wet thickness (1.6 mm). (Subject to the surface being coated.) Wet coverages are for smooth non-porous surfaces. Porous or rough surfaces will require higher gallonage to attain required dry thickness. WATER VAPOR PERMEANCE ASTM F 1249, 0.08 perms at 45 mils dry. Tested at 100°F (38°C) and 50% RH. WET FLAMMABILITY (ASTM D3278) Flash Point: None to boiling, 212°F (100°C) SURFACE BURNING CHARACTERISTICS (ASTM E-84) Flame Spread: 5 Smoke Developed: 30 Surface: Inorganic reinforced cement board Number of Coats: 1 Coverage: 25 sq. ft/gal. (Applied in a 4 inch wide strip) Flash Point of liquid coating, closed cup: No flash to boiling.ASTM E84, ASTM D1475, ASTM D1644, ASTM D1640, ASTM D3278, ASTM E 84, ASTM D 1475, ASTM D 1644, ASTM D 1640, ASTM D 3278, ASTM E-84, ASTM D-1475, ASTM D-1644, ASTM D-1640, ASTM D-3278, CP34sdsmastics-coating
ChildersChilders CP-35 CHIL-PERM Water-Based Vapor Retardant CoatingASTM E-84, NFPA Standard 90-A and 90-B 25/50, WATER VAPOR PERMEANCE ASTM F-1249 0.09 Perms (0.06 metric perms) @ 55 mils (1.4 mm) Dry film thickness. Tested at 73ºF, 50% RH, SERVICE TEMPERATURE RANGE (Temperature to which dry film is subjected.) -20ºF to 190ºF (-29ºC to 88ºC), WET WEIGHT 12.1 lbs./U.S. gal. (1.5 kg/liter)ASTM F1249, ASTM E84, ASTM F 1249, ASTM E 84, ASTM F-1249, ASTM E-84, CP35tdsmastics-coating
ChildersChilders CP-35 CHIL-PERM Water-Based Vapor Retardant CoatingASTM E-84, NFPA Standard 90-A and 90-B 25/50, WATER VAPOR PERMEANCE ASTM F-1249 0.09 Perms (0.06 metric perms) @ 55 mils (1.4 mm) Dry film thickness. Tested at 73ºF, 50% RH, SERVICE TEMPERATURE RANGE (Temperature to which dry film is subjected.) -20ºF to 190ºF (-29ºC to 88ºC), WET WEIGHT 12.1 lbs./U.S. gal. (1.5 kg/liter)ASTM F1249, ASTM E84, ASTM F 1249, ASTM E 84, ASTM F-1249, ASTM E-84, CP35sdsmastics-coating
ChildersChilders CP-70 CHIL-JOINT SealantWATER VAPOR PERMEANCE ASTM F-1249, 0.06 perm (0.04 metric perm) tested in 1/8”( 3.2mm) film at 100o F (38o C) and 90%RH, SERVICE TEMPERATURE RANGE (Temperature to which dry coating is subjected.) -100ºF to 300ºF -73ºC to 149ºC ASTM F1249, ASTM F 1249, ASTM F-1249, CP70tdsadhesives-sealants
ChildersChilders CP-70 CHIL-JOINT SealantWATER VAPOR PERMEANCE ASTM F-1249, 0.06 perm (0.04 metric perm) tested in 1/8”( 3.2mm) film at 100o F (38o C) and 90%RH, SERVICE TEMPERATURE RANGE (Temperature to which dry coating is subjected.) -100ºF to 300ºF -73ºC to 149ºC ASTM F1249, ASTM F 1249, ASTM F-1249, CP70sdsadhesives-sealants
ChildersChilders CP-97 Fibrous AdhesiveCOLOR Beige, WET WEIGHT (ASTM D1475) 12.5 lbs./U.S. gal. (1.5 kg/liter), AVERAGE NON-VOLATILE (ASTM D2369) 59% by weight, SERVICE TEMPERATURE RANGE Temperature to which dry film is subjected. 40ºF to 850ºF (4ºC to 454ºC), APPLICATION TEMPERATURE RANGE Temperature of product when applied. 40°F to 100°F (4°C to 38°C), BONDING TIME 0 – 5 Minutes, DRYING TIME Bonding and drying time will vary depending upon applied thickness, temperature and humidity. 1 Hour, COVERAGE Varies with substrate and membrane. 2.5 – 3.0 U.S. gal./100 sq. ft. (1.0 – 1.2 l/m2), DRY COMBUSTIBILITY Incombustible, CLEAN UP Warm, soapy water ASTM D1475, ASTM D2369, ASTM D 1475, ASTM D 2369, ASTM D-1475, ASTM D-2369, CP97tdsadhesives-sealants
ChildersChilders CP-97 Fibrous AdhesiveCOLOR Beige, WET WEIGHT (ASTM D1475) 12.5 lbs./U.S. gal. (1.5 kg/liter), AVERAGE NON-VOLATILE (ASTM D2369) 59% by weight, SERVICE TEMPERATURE RANGE Temperature to which dry film is subjected. 40ºF to 850ºF (4ºC to 454ºC), APPLICATION TEMPERATURE RANGE Temperature of product when applied. 40°F to 100°F (4°C to 38°C), BONDING TIME 0 – 5 Minutes, DRYING TIME Bonding and drying time will vary depending upon applied thickness, temperature and humidity. 1 Hour, COVERAGE Varies with substrate and membrane. 2.5 – 3.0 U.S. gal./100 sq. ft. (1.0 – 1.2 l/m2), DRY COMBUSTIBILITY Incombustible, CLEAN UP Warm, soapy water ASTM D1475, ASTM D2369, ASTM D 1475, ASTM D 2369, ASTM D-1475, ASTM D-2369, CP97sdsadhesives-sealants
ChildersChilders ENCACEL V CP-45 Vapor Retarder CoatingASTM E84, Meets NFPA Standard 90A and 90B 25/50 requirements, SERVICE TEMPERATURE RANGE Temperature to which dry film is subjected. -50°F to 220°F (-46°C to 104°C), WATER VAPOR PERMEANCE (TYPICAL AVERAGE) ASTM E96, METHOD E: 0.025 perms (0.016 metric perms) at 51 mils dry (1.3 mm) ASTM E96, PROCEDURE A: 0.018 perms (0.012 metric perms) at 26 mils (0.66 mm) dry ASTM F1249: 0.05 perms (0.033 metric perms) at 30 mils dry (0.8 mm). Tested at 100°F (38°C) and 90% RH ENCACEL® V CP-45 meets the permeance requirements of ASTM C755- 19 for below ambient vapor retarder coatings.ASTM E84, ASTM E96, ASTM E96, ASTM F1249, ASTM C755, ASTM E 84, ASTM E 96, ASTM E 96, ASTM F 1249, ASTM C 755, ASTM E-84, ASTM E-96, ASTM E-96, ASTM F-1249, ASTM C-755, CP45tdsmastics-coating
ChildersChilders ENCACEL V CP-45 Vapor Retarder CoatingASTM E84, Meets NFPA Standard 90A and 90B 25/50 requirements, SERVICE TEMPERATURE RANGE Temperature to which dry film is subjected. -50°F to 220°F (-46°C to 104°C), WATER VAPOR PERMEANCE (TYPICAL AVERAGE) ASTM E96, METHOD E: 0.025 perms (0.016 metric perms) at 51 mils dry (1.3 mm) ASTM E96, PROCEDURE A: 0.018 perms (0.012 metric perms) at 26 mils (0.66 mm) dry ASTM F1249: 0.05 perms (0.033 metric perms) at 30 mils dry (0.8 mm). Tested at 100°F (38°C) and 90% RH ENCACEL® V CP-45 meets the permeance requirements of ASTM C755- 19 for below ambient vapor retarder coatings.ASTM E84, ASTM E96, ASTM E96, ASTM F1249, ASTM C755, ASTM E 84, ASTM E 96, ASTM E 96, ASTM F 1249, ASTM C 755, ASTM E-84, ASTM E-96, ASTM E-96, ASTM F-1249, ASTM C-755, CP45sdsmastics-coating
ChildersChilders VI-CRYL CP-10/11 Weather Barrier CoatingASTM E-84, NFPA Standard 90-A and 90-B 25/50. WET WEIGHT 11.3 lbs./U.S. gal. (1.35 kg/liter) AVERAGE NON-VOLATILE 51% by volume (64% by weight) SERVICE TEMPERATURE RANGE (Temperature to which dry coating is subjected.) -40ºF to 180ºF (-40ºC to 83ºC) APPLICATION TEMPERATURE RANGE 40ºF to 100ºF (4ºC to 38ºC) DRYING TIME Touch - 2-4 hours Through - 24-36 hours (Drying time will vary depending upon film thickness, temperature and humidity.) COVERAGE 6 U.S. gal./100 sq. ft. (2.4 l/sq.m) (Varies with substrate and membrane.) CLEAN-UP Warm, soapy water (wet) xylol (dry) WATER VAPOR PERMEANCE ASTM E-96 Greater than 1.0 perm for 1/16 inch (0.16cm) dry film. (Procedure B)ASTM E84, ASTM E96, ASTM E 84, ASTM E 96, ASTM E-84, ASTM E-96. CP-10, CP-11. CP10, CP11tdsmastics-coating
ChildersChilders VI-CRYL CP-10/11 Weather Barrier CoatingASTM E-84, NFPA Standard 90-A and 90-B 25/50. WET WEIGHT 11.3 lbs./U.S. gal. (1.35 kg/liter) AVERAGE NON-VOLATILE 51% by volume (64% by weight) SERVICE TEMPERATURE RANGE (Temperature to which dry coating is subjected.) -40ºF to 180ºF (-40ºC to 83ºC) APPLICATION TEMPERATURE RANGE 40ºF to 100ºF (4ºC to 38ºC) DRYING TIME Touch - 2-4 hours Through - 24-36 hours (Drying time will vary depending upon film thickness, temperature and humidity.) COVERAGE 6 U.S. gal./100 sq. ft. (2.4 l/sq.m) (Varies with substrate and membrane.) CLEAN-UP Warm, soapy water (wet) xylol (dry) WATER VAPOR PERMEANCE ASTM E-96 Greater than 1.0 perm for 1/16 inch (0.16cm) dry film. (Procedure B)ASTM E84, ASTM E96, ASTM E 84, ASTM E 96, ASTM E-84, ASTM E-96, CP-10, CP-11. CP10, CP11sdsmastics-coating
CL WardCL Ward BioCoat Antimicrobial Encapsulating CoatingUL 723 Classified • TVOC Emissions: CDPH Standard Method v1.2 = Private Office - Pass: School Classroom - Pass • VOC Content: EPA Method 24 Test = Pass - Very Low • Dry Time: 11 minutes at 4mils wet film thickness and 76°F, depending on temperature, humidity and application thickness • Mold and Mildew Resistant: ASTM G21: Standard Practice for Determining Resistance of Synthetic Poymeric Materials to Fungi - Pass ASTM Method D 4300-01: Standard Test Methods for Ability of Adhesive Films to Support or Resist the Growth of Fungi - Pass • ASTM D2574: Standard Test Method for Resistance of Emulsion Paints in the Container to Attack by Microorganisms - Pass • Application Temp: 20°F to 90°F • Storage Temp: 20°F to 90°F • Coverage: 400 sq.ft. per gallon.UL723, ASTM G21, ASTM Method D4300, ASTM D2574. UL 723, ASTM G 21, ASTM Method D 4300, ASTM D 2574. UL-723, ASTM G-21, ASTM Method D-4300, ASTM D-2574tdsmastics-coating
CL WardCL Ward BioCoat Antimicrobial Encapsulating CoatingUL 723 Classified • TVOC Emissions: CDPH Standard Method v1.2 = Private Office - Pass: School Classroom - Pass • VOC Content: EPA Method 24 Test = Pass - Very Low • Dry Time: 11 minutes at 4mils wet film thickness and 76°F, depending on temperature, humidity and application thickness • Mold and Mildew Resistant: ASTM G21: Standard Practice for Determining Resistance of Synthetic Poymeric Materials to Fungi - Pass ASTM Method D 4300-01: Standard Test Methods for Ability of Adhesive Films to Support or Resist the Growth of Fungi - Pass • ASTM D2574: Standard Test Method for Resistance of Emulsion Paints in the Container to Attack by Microorganisms - Pass • Application Temp: 20°F to 90°F • Storage Temp: 20°F to 90°F • Coverage: 400 sq.ft. per gallon.UL723, ASTM G21, ASTM Method D4300, ASTM D2574. UL 723, ASTM G 21, ASTM Method D 4300, ASTM D 2574. UL-723, ASTM G-21, ASTM Method D-4300, ASTM D-2574sdsmastics-coating
The Claremont CompanyClaremont Low K 200 and 340 Polyimide HullboardMIL-I-24703, MIL-T-24708, DOD-I-24688, PPD-802-6335736, PPD-802-6335737, PPD-802-6335741tdsmarine-insulation
The Claremont Company Claremont Low K 200 and 340 Polyimide HullboardMIL-I-24703, MIL-T-24708, DOD-I-24688, PPD-802-6335736, PPD-802-6335737, PPD-802-6335741sdsmarine-insulation
3MCompac 105 ASJ Insulation TapeSubstrate (Backing) ASTM C 1136 ASJ, Meets Type I - IV. Adhesive Infrared Analysis Acrylic Liner Visual Kraft Thickness without Liner PSTC 33/ASTM D 3652 11 mils 0.28 mm Peel Adhesion to Steel PSTC 1/ASTM D 3330 96 oz/in 1.05 kN/m Tensile Strength PSTC 31/ASTM D 3759 50 lb/in 8.8 kN/m Elongation PSTC 31/ASTM D 3759 1% Permeance ASTM E 96, Procedure A 0.02 perm 1.15 ng/m2 ·s·Pa .Surface Burning Characteristics UL 723/ASTM E 84 UL File No. R10984 5 flame 5 smokeASTM C1136, ASTM E96, ASTM E84, ASTM D3652, ASTM D3330, ASTM D3759, ASTM C 1136, ASTM E 96, ASTM E 84, ASTM D 3652, ASTM D 3330, ASTM D 3759, ASTM C-1136, ASTM E-96, ASTM E-84, ASTM D-3652, ASTM D-3330, ASTM D-3759tdstapes
3MCompac 105 ASJ Insulation TapeSubstrate (Backing) ASTM C 1136 ASJ, Meets Type I - IV. Adhesive Infrared Analysis Acrylic Liner Visual Kraft Thickness without Liner PSTC 33/ASTM D 3652 11 mils 0.28 mm Peel Adhesion to Steel PSTC 1/ASTM D 3330 96 oz/in 1.05 kN/m Tensile Strength PSTC 31/ASTM D 3759 50 lb/in 8.8 kN/m Elongation PSTC 31/ASTM D 3759 1% Permeance ASTM E 96, Procedure A 0.02 perm 1.15 ng/m2 ·s·Pa .Surface Burning Characteristics UL 723/ASTM E 84 UL File No. R10984 5 flame 5 smokeASTM C1136, ASTM E96, ASTM E84, ASTM D3652, ASTM D3330, ASTM D3759, ASTM C 1136, ASTM E 96, ASTM E 84, ASTM D 3652, ASTM D 3330, ASTM D 3759, ASTM C-1136, ASTM E-96, ASTM E-84, ASTM D-3652, ASTM D-3330, ASTM D-3759sdstapes
3MCompac 110 FSK Insulation TapeSubstrate (Backing) ASTM C 1136 Type II,IV FSK, Meets Types II,lV Adhesive Infrared Analysis Acrylic Liner Visual Kraft Thickness without Liner PSTC 33/ASTM D 3652 9 mils 0.23 mm Peel Adhesion to Steel PSTC 1/ASTM D 3330 90 oz/in 1.0 kN/m Tensile Strength PSTC 31/ASTM D 3759 30 lb/in 5.3 kN/m Elongation PSTC 31/ASTM D 3759 1% Permeance ASTM E 96, Procedure A 0.02 perm 1.15 ng/m2 ·s·Pa Surface Burning Characteristics UL 723/ASTM E 84 UL File No. R6131 5 flame 0 smoke.ASTM C1136, ASTM E96, ASTM E84, ASTM D3652, ASTM D3330, ASTM D3759, ASTM C 1136, ASTM E 96, ASTM E 84, ASTM D 3652, ASTM D 3330, ASTM D 3759, ASTM C-1136, ASTM E-96, ASTM E-84, ASTM D-3652, ASTM D-3330, ASTM D-3759tdstapes
3MCompac 110 FSK Insulation TapeSubstrate (Backing) ASTM C 1136 Type II,IV FSK, Meets Types II,lV Adhesive Infrared Analysis Acrylic Liner Visual Kraft Thickness without Liner PSTC 33/ASTM D 3652 9 mils 0.23 mm Peel Adhesion to Steel PSTC 1/ASTM D 3330 90 oz/in 1.0 kN/m Tensile Strength PSTC 31/ASTM D 3759 30 lb/in 5.3 kN/m Elongation PSTC 31/ASTM D 3759 1% Permeance ASTM E 96, Procedure A 0.02 perm 1.15 ng/m2 ·s·Pa Surface Burning Characteristics UL 723/ASTM E 84 UL File No. R6131 5 flame 0 smoke.ASTM C1136, ASTM E96, ASTM E84, ASTM D3652, ASTM D3330, ASTM D3759, ASTM C 1136, ASTM E 96, ASTM E 84, ASTM D 3652, ASTM D 3330, ASTM D 3759, ASTM C-1136, ASTM E-96, ASTM E-84, ASTM D-3652, ASTM D-3330, ASTM D-3759sdstapes
3MCompac 120 Aluminum Foil Insulation TapeSubstrate (Backing) Visual, Micrometer 2 mil Aluminum Foil Adhesive Infrared Analysis Acrylic Liner Visual Kraft Thickness without Liner PSTC 33/ASTM D 3652 3.3 mils 0.08 mm Peel Adhesion to Steel PSTC 1/ASTM D 3330 60 oz/in 0.66 kN/m Tensile Strength PSTC 31/ASTM D 3759 15 lb/in 2.6 kN/m Elongation PSTC 31/ASTM D 3759 1% Permeance ASTM E 96, Procedure A 0.0 perm 0.0 ng/m2 ·s·Pa Surface Burning Characteristics UL 723/ASTM E 84 UL File No. R10984 5 flame 0 smoke.ASTM E96, ASTM E84, ASTM D3652, ASTM D3330, ASTM D3759, ASTM E 96, ASTM E 84, ASTM D 3652, ASTM D 3330, ASTM D 3759, ASTM E-96, ASTM E-84, ASTM D-3652, ASTM D-3330, ASTM D-3759tdstapes
3MCompac 120 Aluminum Foil Insulation TapeSubstrate (Backing) Visual, Micrometer 2 mil Aluminum Foil Adhesive Infrared Analysis Acrylic Liner Visual Kraft Thickness without Liner PSTC 33/ASTM D 3652 3.3 mils 0.08 mm Peel Adhesion to Steel PSTC 1/ASTM D 3330 60 oz/in 0.66 kN/m Tensile Strength PSTC 31/ASTM D 3759 15 lb/in 2.6 kN/m Elongation PSTC 31/ASTM D 3759 1% Permeance ASTM E 96, Procedure A 0.0 perm 0.0 ng/m2 ·s·Pa Surface Burning Characteristics UL 723/ASTM E 84 UL File No. R10984 5 flame 0 smoke.ASTM E96, ASTM E84, ASTM D3652, ASTM D3330, ASTM D3759, ASTM E 96, ASTM E 84, ASTM D 3652, ASTM D 3330, ASTM D 3759, ASTM E-96, ASTM E-84, ASTM D-3652, ASTM D-3330, ASTM D-3759sdstapes
Aspen AerogelsCryogel Z Flexible Aerogel Blanket InsulationASTM C 1728, Type 1, Grade 1B Standard Specification for Flexible Aerogel Insulation 1 Complies ASTM C 795 Standard Specification for Thermal Insulation for Use in Contact With Austenitic Steel Pass ASTM C 1101 Flexibility at Cryogenic Temperature Resilient Flexible ASTM C 1104 Water Vapor Sorption ≤5% (weight) ASTM C 1338 Fungi Resistance No Growth ASTM C 1511 Water Retention after Submersion in Water 2 ≤5% (weight) ASTM E 84 Flame and Smoke Spread Class A: FSI <25 SDI <50 ASTM E 96 Water Vapor Transmission Rate (with vapor retarder) 0.00 perm ISO 15665 Acoustic Insulation for Pipes, Valves and Flanges 3 Meets Class A, B, C, and Shell D OTI 95 634 Jet-Fire Resistance Test of Passive Fire Protection Materials 3, 4, 5 75 min 60 mm 120 min 100 mm UL 1709 Structural Steel Fire Protection 3, 5 30 min 20 mm 60 min 30 mm 90 min 50 mm 120 min 60 mm 150 min 70 mm.ASTM C1728, ASTM C795, ASTM C1101, ASTM C1104, ASTM C1338, ASTM C1511, ASTM E84, ASTM E96, ASTM C 1728, ASTM C 795, ASTM C 1101, ASTM C 1104, ASTM C 1338, ASTM C 1511, ASTM E 84, ASTM E 96, ASTM C-1728, ASTM C-795, ASTM C-1101, ASTM C-1104, ASTM C-1338, ASTM C-1511, ASTM E-84, ASTM E-96tdsaerogel
Aspen AerogelsCryogel Z Flexible Aerogel Blanket InsulationASTM C 1728, Type 1, Grade 1B Standard Specification for Flexible Aerogel Insulation 1 Complies ASTM C 795 Standard Specification for Thermal Insulation for Use in Contact With Austenitic Steel Pass ASTM C 1101 Flexibility at Cryogenic Temperature Resilient Flexible ASTM C 1104 Water Vapor Sorption ≤5% (weight) ASTM C 1338 Fungi Resistance No Growth ASTM C 1511 Water Retention after Submersion in Water 2 ≤5% (weight) ASTM E 84 Flame and Smoke Spread Class A: FSI <25 SDI <50 ASTM E 96 Water Vapor Transmission Rate (with vapor retarder) 0.00 perm ISO 15665 Acoustic Insulation for Pipes, Valves and Flanges 3 Meets Class A, B, C, and Shell D OTI 95 634 Jet-Fire Resistance Test of Passive Fire Protection Materials 3, 4, 5 75 min 60 mm 120 min 100 mm UL 1709 Structural Steel Fire Protection 3, 5 30 min 20 mm 60 min 30 mm 90 min 50 mm 120 min 60 mm 150 min 70 mmASTM C1728, ASTM C795, ASTM C1101, ASTM C1104, ASTM C1338, ASTM C1511, ASTM E84, ASTM E96, ASTM C 1728, ASTM C 795, ASTM C 1101, ASTM C 1104, ASTM C 1338, ASTM C 1511, ASTM E 84, ASTM E 96, ASTM C-1728, ASTM C-795, ASTM C-1101, ASTM C-1104, ASTM C-1338, ASTM C-1511, ASTM E-84, ASTM E-96sdsaerogel
DeltaDELTA-DRY STUCCO & STONE VENTILATED RAINSCREENDimple height approx. 2/5” (10.5 mm) ASTM D1777-96 Compressive strength 93 kPa (1,946 psf) @ 8 % strain ASTM D6364-06 Drainage efficiency approx. 95% ASTM 2273 Fungus resistance Does not support fungus growth ASTM C1338 Flame spread 210 CAN/ULC-S102.2 Smoke developed 105-190 CAN/ULC-S102.2 Water penetration resistance 118 psi (813 kPa)Watertight AATCC 127 Water vapor transmission 22 ng/(Pa s m²) ASTM E96, Method A Vapor Permeance 0.14 perms [grains/h/ft²/in Hg] ASTM E96, Method A Ventilation/Airflow 1.18 L/s @ 10Pa* 1.41L/s @ 10Pa** ASTM E2954-14 Drainage 1.94% * 0.65% ** ASTM E2954-14 Thickness PASS ASTM D5199-14 Compression Strength 123.2 kPa ASTM D5199-12 UV Exposure PASS ASTM D6363-06 Heat Aging PASS ASTM D6364-06 Mold/Fungal Growth No Mold ASTM D1338-14 Water Exposure PASS ASTM D6364-06 Contact surface of rainscreen to WRB less than 20% greater than 80% open Chemical properties excellent chemical resistance, rot-proof Toxicity non-toxic, non-polluting Temperature range -22°F to +176°F (-30°C to +80°C) Weight per unit area approx. 1.71 oz/ft² (525 g/m²) ASTM D5261-92.ASTM D1777, ASTM D6364, ASTM 2273, ASTM C1338, ASTM E96, ASTM E2954, ASTM D5199, ASTM D5199, ASTM D6363, ASTM D1338, ASTM D6364, ASTM D5261, ASTM D 1777, ASTM D 6364, ASTM 2273, ASTM C 1338, ASTM E 96, ASTM E 2954, ASTM D 5199, ASTM D 5199, ASTM D 6363, ASTM D 1338, ASTM D 6364, ASTM D 5261, ASTM D-1777, ASTM D-6364, ASTM 2273, ASTM C-1338, ASTM E-96, ASTM E-2954, ASTM D-5199, ASTM D-5199, ASTM D-6363, ASTM D-1338, ASTM D-6364, ASTM D-5261tdsair-vapor-barriers-waterproofing-systems
DeltaDELTA-DRY STUCCO & STONE VENTILATED RAINSCREENDimple height approx. 2/5” (10.5 mm) ASTM D1777-96 Compressive strength 93 kPa (1,946 psf) @ 8 % strain ASTM D6364-06 Drainage efficiency approx. 95% ASTM 2273 Fungus resistance Does not support fungus growth ASTM C1338 Flame spread 210 CAN/ULC-S102.2 Smoke developed 105-190 CAN/ULC-S102.2 Water penetration resistance 118 psi (813 kPa)Watertight AATCC 127 Water vapor transmission 22 ng/(Pa s m²) ASTM E96, Method A Vapor Permeance 0.14 perms [grains/h/ft²/in Hg] ASTM E96, Method A Ventilation/Airflow 1.18 L/s @ 10Pa* 1.41L/s @ 10Pa** ASTM E2954-14 Drainage 1.94% * 0.65% ** ASTM E2954-14 Thickness PASS ASTM D5199-14 Compression Strength 123.2 kPa ASTM D5199-12 UV Exposure PASS ASTM D6363-06 Heat Aging PASS ASTM D6364-06 Mold/Fungal Growth No Mold ASTM D1338-14 Water Exposure PASS ASTM D6364-06 Contact surface of rainscreen to WRB less than 20% greater than 80% open Chemical properties excellent chemical resistance, rot-proof Toxicity non-toxic, non-polluting Temperature range -22°F to +176°F (-30°C to +80°C) Weight per unit area approx. 1.71 oz/ft² (525 g/m²) ASTM D5261-92.ASTM D1777, ASTM D6364, ASTM 2273, ASTM C1338, ASTM E96, ASTM E2954, ASTM D5199, ASTM D5199, ASTM D6363, ASTM D1338, ASTM D6364, ASTM D5261, ASTM D 1777, ASTM D 6364, ASTM 2273, ASTM C 1338, ASTM E 96, ASTM E 2954, ASTM D 5199, ASTM D 5199, ASTM D 6363, ASTM D 1338, ASTM D 6364, ASTM D 5261, ASTM D-1777, ASTM D-6364, ASTM 2273, ASTM C-1338, ASTM E-96, ASTM E-2954, ASTM D-5199, ASTM D-5199, ASTM D-6363, ASTM D-1338, ASTM D-6364, ASTM D-5261sdsair-vapor-barriers-waterproofing-systems
DeltaDELTA-FASSADE SA AIR & WATER BARRIERVapor permeance 30 perms [grains/h/ft²/in Hg] ASTM E96-05, Proc. A 50 perms [grains/h/ft²/in Hg] ASTM E96-05, Proc. B Water vapor transmission 214 g/m²/24 h ASTM E96-05, Proc. A 343 g/m²/24 h ASTM E96-05, Proc. B Tensile strength MD 101 lbf ASTM D5034 XD 94 lbf Elongation at break MD 40 % ASTM D5034 XD 58 % 90° Peel adhesion Pass AAMA 711-5.3 (ASTM D3330) Accelerated aging (UV) Pass AAMA 711-5.4 Elevated temperature Pass (Level 3) AAMA 711-5.5 Thermal cycling Pass AAMA 711-5.6 Adhesion after water immersion Pass AAMA 711-5.8 Air permeance < 0.02 l/(s x m²) @ 75 Pa ASTM E2178 Water resistance hydrostatic pressure Pass 60 minute Grade D building paper equivalent ASTM D779-03 Flame spread 10 ASTM E84-18 NFPA Class A; IBC Class A Smoke developed 95 ASTM E84-18 NFPA Class A; IBC Class A Service temperature -40 °F to +176 °F (-40 °C to +80 °C) Application temperature Minimum 40 °F (5 °C).ASTM E96, ASTM D5034, ASTM D5034, ASTM D3330, ASTM E2178, ASTM D779, ASTM E84, ASTM E 96, ASTM D 5034, ASTM D 5034, ASTM D 3330, ASTM E 2178, ASTM D 779, ASTM E 84, ASTM E-96, ASTM D-5034, ASTM D-5034, ASTM D-3330, ASTM E-2178, ASTM D-779, ASTM E-84tdsair-vapor-barriers-waterproofing-systems
DeltaDELTA-FASSADE SA AIR & WATER BARRIERVapor permeance 30 perms [grains/h/ft²/in Hg] ASTM E96-05, Proc. A 50 perms [grains/h/ft²/in Hg] ASTM E96-05, Proc. B Water vapor transmission 214 g/m²/24 h ASTM E96-05, Proc. A 343 g/m²/24 h ASTM E96-05, Proc. B Tensile strength MD 101 lbf ASTM D5034 XD 94 lbf Elongation at break MD 40 % ASTM D5034 XD 58 % 90° Peel adhesion Pass AAMA 711-5.3 (ASTM D3330) Accelerated aging (UV) Pass AAMA 711-5.4 Elevated temperature Pass (Level 3) AAMA 711-5.5 Thermal cycling Pass AAMA 711-5.6 Adhesion after water immersion Pass AAMA 711-5.8 Air permeance < 0.02 l/(s x m²) @ 75 Pa ASTM E2178 Water resistance hydrostatic pressure Pass 60 minute Grade D building paper equivalent ASTM D779-03 Flame spread 10 ASTM E84-18 NFPA Class A; IBC Class A Smoke developed 95 ASTM E84-18 NFPA Class A; IBC Class A Service temperature -40 °F to +176 °F (-40 °C to +80 °C) Application temperature Minimum 40 °F (5 °C).ASTM E96, ASTM D5034, ASTM D5034, ASTM D3330, ASTM E2178, ASTM D779, ASTM E84, ASTM E 96, ASTM D 5034, ASTM D 5034, ASTM D 3330, ASTM E 2178, ASTM D 779, ASTM E 84, ASTM E-96, ASTM D-5034, ASTM D-5034, ASTM D-3330, ASTM E-2178, ASTM D-779, ASTM E-84sdsair-vapor-barriers-waterproofing-systems
Design PolymericsDesign Polymerics DP 240 / DP 340 Foil Mastic TapeASTM E-96, NFPA 90A & 90B, ASTM E-84, and UL-723, Color: Aluminum Foil/Dark Gray Butyl, Chemical Family: Butyl Rubber, Solids Content: 100%, Application Temperature: 0°F to 120°F, Storage Temperature: 0°F to 120°F, Service Temperature: -25°F to 200°F, Freeze/Thaw Stability: Yes, Perm Rating: .02, perm ASTM E-96, Flammability: Non-flammable wet or dry Flash Point: No flash to boiling, Shelf Life: Minimum 2 Years, Cure Time: Immediate Coverage: 100, Linear feet per roll.ASTM E96, ASTM E84, ASTM E 96, ASTM E 84, ASTM E-96, ASTM E-84tdstapes
Design PolymericsDesign Polymerics DP 240 / DP 340 Foil Mastic TapeASTM E-96, NFPA 90A & 90B, ASTM E-84, and UL-723, Color: Aluminum Foil/Dark Gray Butyl, Chemical Family: Butyl Rubber, Solids Content: 100%, Application Temperature: 0°F to 120°F, Storage Temperature: 0°F to 120°F, Service Temperature: -25°F to 200°F, Freeze/Thaw Stability: Yes, Perm Rating: .02, perm ASTM E-96, Flammability: Non-flammable wet or dry Flash Point: No flash to boiling, Shelf Life: Minimum 2 Years, Cure Time: Immediate Coverage: 100, Linear feet per roll.ASTM E96, ASTM E84, ASTM E 96, ASTM E 84, ASTM E-96, ASTM E-84sdstapes
Design PolymericsDesign Polymerics DP 2502 Water Based Duct Liner AdhesiveNFPA 90A & 90B, ASTM E-84, UL 723, ASTM C-916 Type II, Color: Black or White. Base: Water. Chemical Family: Synthetic Latex. Solids Content: 40 ± 2%. Viscosity: Approx. 2,500 - 3,500 cps. Application Temperature: 40°F - 110°F Storage Temperature: 40°F - 110°F. Do not allow to freeze Service Temperature: -25°F - 200°F. Freeze/Thaw Stability: Do not allow to freeze. Flammability: Non-flammable wet or dry. Flash Point: No flash to boiling. Shelf Life: 1 Year (unopened containers). Open Time: 10 to 20 minutes depending on humidity, temperature, and application rate. Coverage: Typical spray application may yield up to 400 sq. ft. per gallon.ASTM E84, ASTM C916 , ASTM E 84, ASTM C 916 , ASTM E-84, ASTM C-916, DP-2502, DP2502tdsadhesives-sealants
Design PolymericsDesign Polymerics DP 2502 Water Based Duct Liner AdhesiveNFPA 90A & 90B, ASTM E-84, UL 723, ASTM C-916 Type II, Color: Black or White. Base: Water. Chemical Family: Synthetic Latex. Solids Content: 40 ± 2%. Viscosity: Approx. 2,500 - 3,500 cps. Application Temperature: 40°F - 110°F Storage Temperature: 40°F - 110°F. Do not allow to freeze Service Temperature: -25°F - 200°F. Freeze/Thaw Stability: Do not allow to freeze. Flammability: Non-flammable wet or dry. Flash Point: No flash to boiling. Shelf Life: 1 Year (unopened containers). Open Time: 10 to 20 minutes depending on humidity, temperature, and application rate. Coverage: Typical spray application may yield up to 400 sq. ft. per gallon.ASTM E84, ASTM C916 , ASTM E 84, ASTM C 916 , ASTM E-84, ASTM C-916, DP-2502, DP2502sdsadhesives-sealants
Design PolymericsDesign Polymerics DP 2590 Solvent Based Spray Fiberglass AdhesiveColor: Green Solvent: Methylene Chloride Chemical Family: Synthetic rubber and resin Application Temperature: 30°F - 110°F Service Temperature: -20°F - 160°F Flammability: Non-flammable after application Flash Point: None when dry Bonding Time: 1 to 5 minutes depending on humidity, temperature, and substrate Coverage: Typical spray application will yield up to 100 sq. ft. per pound Packaging: Net wt. 12 lb. and 40 lb. disposable spray canisters Shelf Life: 1 YearDP-2590, DP2590tdsadhesives-sealants
Design PolymericsDesign Polymerics DP 2590 Solvent Based Spray Fiberglass AdhesiveColor: Green Solvent: Methylene Chloride Chemical Family: Synthetic rubber and resin Application Temperature: 30°F - 110°F Service Temperature: -20°F - 160°F Flammability: Non-flammable after application Flash Point: None when dry Bonding Time: 1 to 5 minutes depending on humidity, temperature, and substrate Coverage: Typical spray application will yield up to 100 sq. ft. per pound Packaging: Net wt. 12 lb. and 40 lb. disposable spray canisters Shelf Life: 1 YearDP-2590, DP2590sdsadhesives-sealants
Design PolymericsDesign Polymerics DP 2595 Closed Cell Foam Spray AdhesiveColor: Clear Solvent: Methylene Chloride Chemical Family: Synthetic polymer Application Temperature: 30°F - 110°F Service Temperature: -20°F - 200°F Flammability: Non-flammable after application Flash Point: None when dry Bonding Time: 1 to 5 minutes depending on humidity, temperature, and substrate Coverage: Typical spray application will yield up to 100 sq. ft. per pound Packaging: Net wt. 11 lb. and 38 lb. disposable spray canisters Shelf Life: 1 YearDP-2595, DP2595tdsadhesives-sealants
Design PolymericsDesign Polymerics DP 2595 Closed Cell Foam Spray AdhesiveColor: Clear Solvent: Methylene Chloride Chemical Family: Synthetic polymer Application Temperature: 30°F - 110°F Service Temperature: -20°F - 200°F Flammability: Non-flammable after application Flash Point: None when dry Bonding Time: 1 to 5 minutes depending on humidity, temperature, and substrate Coverage: Typical spray application will yield up to 100 sq. ft. per pound Packaging: Net wt. 11 lb. and 38 lb. disposable spray canisters Shelf Life: 1 YearDP-2595, DP2595sdsadhesives-sealants
Design PolymericsDesign Polymerics DP 3040 Vapor Barrier CoatingNFPA 90A & 90B, and ASTM E-84, ASTM E-96-00 Method B, ASTM E-96-00 Method D, Color: White Base: Water Chemical Family: Synthetic Latex Solids Content: 66 ± 2% Viscosity: Approx. 75,000 - 90,000 cps Application Temperature: 40°F - 110°F. Storage Temperature: 40°F - 110°F. Service Temperature: -25°F - 200°F Freeze/Thaw Stability: Do not allow to freeze Average Perm Rating: 0.016 perms (ASTM E-96-00 Method B) at 42 mils dry film thickness 0.018 perms (ASTM E-96-00 Method D) at 50 mils dry film thickness Flammability: Non-flammable wet or dry. Flash Point: No flash to boiling Shelf Life: 1 Year (unopened containers). Cure Time: 4 to 36 hours depending on humidity, temperature, and application rateASTM E84, ASTM E96, ASTM E 84, ASTM E 96, ASTM E-84, ASTM E-96, DP-3040, DP3040tdsmastics-coating
Design PolymericsDesign Polymerics DP 3040 Vapor Barrier CoatingNFPA 90A & 90B, and ASTM E-84, ASTM E-96-00 Method B, ASTM E-96-00 Method D, Color: White Base: Water Chemical Family: Synthetic Latex Solids Content: 66 ± 2% Viscosity: Approx. 75,000 - 90,000 cps Application Temperature: 40°F - 110°F. Storage Temperature: 40°F - 110°F. Service Temperature: -25°F - 200°F Freeze/Thaw Stability: Do not allow to freeze Average Perm Rating: 0.016 perms (ASTM E-96-00 Method B) at 42 mils dry film thickness 0.018 perms (ASTM E-96-00 Method D) at 50 mils dry film thickness Flammability: Non-flammable wet or dry. Flash Point: No flash to boiling Shelf Life: 1 Year (unopened containers). Cure Time: 4 to 36 hours depending on humidity, temperature, and application rateASTM E84, ASTM E96, ASTM E 84, ASTM E 96, ASTM E-84, ASTM E-96, DP-3040, DP3040sdsmastics-coating
Design PolymericsDesign Polymerics DP 3040 Vapor Barrier MasticASTM E-96-00 Method B, (ASTM E-96-00 Method D, Color: White Base: Water Chemical Family: Synthetic Latex Solids Content: 66 ± 2% Viscosity: Approx. 75,000 - 90,000 cps Application Temperature: 40°F - 110°F Storage Temperature: 40°F - 110°F Service Temperature: -25°F - 200°F Freeze/Thaw Stability: Do not allow to freeze Average Permeability: 0.016 perms (ASTM E-96-00 Method B) 0.018 perms (ASTM E-96-00 Method D) Flammability: Non-flammable wet or dry Flash Point: No flash to boiling Shelf Life: 1 Year (unopened containers) Cure Time: 4 to 36 hours depending on humidity, temperature, and application rateASTM E96, ASTM E 96, ASTM E-96, DP-3040, DP3040tdsmastics-coating
Design PolymericsDesign Polymerics DP 3040 Vapor Barrier MasticASTM E-96-00 Method B, (ASTM E-96-00 Method D, Color: White Base: Water Chemical Family: Synthetic Latex Solids Content: 66 ± 2% Viscosity: Approx. 75,000 - 90,000 cps Application Temperature: 40°F - 110°F Storage Temperature: 40°F - 110°F Service Temperature: -25°F - 200°F Freeze/Thaw Stability: Do not allow to freeze Average Permeability: 0.016 perms (ASTM E-96-00 Method B) 0.018 perms (ASTM E-96-00 Method D) Flammability: Non-flammable wet or dry Flash Point: No flash to boiling Shelf Life: 1 Year (unopened containers) Cure Time: 4 to 36 hours depending on humidity, temperature, and application rate.ASTM E96, ASTM E 96, ASTM E-96, DP-3040, DP3040sdsmastics-coating
Design PolymericsDesign Polymerics DP 3050 AF Antifungal Water Based Lagging AdhesiveNFPA 90A & 90B, UL 723, and ASTM E-84, Color: White Base: Water Chemical Family: Synthetic Latex Solids Content: 56 ± 2% Viscosity: Approx. 50,000 - 70,000 cps Application Temperature: 40°F - 110°F Storage Temperature: 40°F - 110°F Service Temperature: -25°F - 200°F Freeze/Thaw Stability: Through 5 cycles with no deterioration (DPTM-20) Flammability: Non-flammable wet or dry Flash Point: No flash to boiling Shelf Life: 1 Year (unopened containers) Cure Time: 8 to 72 hours depending on humidity, temperature and application rate Coverage: Dependent on application thickness and material. 50-100 sq. ft. per gallon per coatASTM E84, ASTM E 84, ASTM E-84, DP-3050, DP3050tdsmastics-coating
Design PolymericsDesign Polymerics DP 3050 AF Antifungal Water Based Lagging AdhesiveNFPA 90A & 90B, UL 723, and ASTM E-84, Color: White Base: Water Chemical Family: Synthetic Latex Solids Content: 56 ± 2% Viscosity: Approx. 50,000 - 70,000 cps Application Temperature: 40°F - 110°F Storage Temperature: 40°F - 110°F Service Temperature: -25°F - 200°F Freeze/Thaw Stability: Through 5 cycles with no deterioration (DPTM-20) Flammability: Non-flammable wet or dry Flash Point: No flash to boiling Shelf Life: 1 Year (unopened containers) Cure Time: 8 to 72 hours depending on humidity, temperature and application rate Coverage: Dependent on application thickness and material. 50-100 sq. ft. per gallon per coatASTM E84, ASTM E 84, ASTM E-84, DP-3050, DP3050sdsmastics-coating
Design PolymericsDesign Polymerics DP 3050 Water Based Lagging AdhesiveNFPA 90A & 90B, UL 723, and ASTM E-84, ASTM E-96-00 Method B,Color: White Base: Water Chemical Family: Synthetic Latex Solids Content: 56 ± 2% Viscosity: Approx. 50,000 - 70,000 cps Application Temperature: 40°F - 110°F Storage Temperature: 40°F - 110°F Service Temperature: -25°F - 200°F Freeze/Thaw Stability: Through 5 cycles with no deterioration (DPTM-20) Average Permeability: 0.24 perms (ASTM E-96-00 Method B) Flammability: Non-flammable wet or dry Flash Point: No flash to boiling Shelf Life: 1 Year (unopened containers) Cure Time: 8 to 72 hours depending on humidity, temperature and application rate Coverage: Dependent on application thickness and material. 50-100 sq. ft. per gallon per coat.ASTM E84, ASTM E96, ASTM E 84, ASTM E 96, ASTM E-84, ASTM E-96, DP-3050, DP3050tdsmastics-coating
Design PolymericsDesign Polymerics DP 3050 Water Based Lagging AdhesiveNFPA 90A & 90B, UL 723, and ASTM E-84, ASTM E-96-00 Method B, Color: White Base: Water Chemical Family: Synthetic Latex Solids Content: 56 ± 2% Viscosity: Approx. 50,000 - 70,000 cps Application Temperature: 40°F - 110°F Storage Temperature: 40°F - 110°F Service Temperature: -25°F - 200°F Freeze/Thaw Stability: Through 5 cycles with no deterioration (DPTM-20) Average Permeability: 0.24 perms (ASTM E-96-00 Method B) Flammability: Non-flammable wet or dry Flash Point: No flash to boiling Shelf Life: 1 Year (unopened containers) Cure Time: 8 to 72 hours depending on humidity, temperature and application rate Coverage: Dependent on application thickness and material. 50-100 sq. ft. per gallon per coatASTM E84, ASTM E96, ASTM E 84, ASTM E 96, ASTM E-84, ASTM E-96, DP-3050, DP3050sdsmastics-coating
Design PolymericsDesign Polymerics DP 502 100% RTV Silicone• ASTM C920 Type S, Grade NS, Class 25 • ASTM G26 • TT-S 001543A, TT-S 00230C Type II • QUV Testing (ASTM G26): Pass 10,000 hours • FDA Regulation No. 21 CFR177.2600 • NSF Standard 51 • UL Recognized • MIL-46106 TYPE 1. Packaging: 10 fl. oz. tubes VOC: 23 g/lASTM C920, ASTM G26, MIL46106. ASTM C 920, ASTM G 26, MIL 46106. ASTM C-920, ASTM G-26, MIL-46106.tdsadhesives-sealants
Design PolymericsDesign Polymerics DP 502 100% RTV Silicone• ASTM C920 Type S, Grade NS, Class 25 • ASTM G26 • TT-S 001543A, TT-S 00230C Type II • QUV Testing (ASTM G26): Pass 10,000 hours • FDA Regulation No. 21 CFR177.2600 • NSF Standard 51 • UL Recognized • MIL-46106 TYPE 1. Packaging: 10 fl. oz. tubes VOC: 23 g/lASTM C920, ASTM G26, MIL46106. ASTM C 920, ASTM G 26, MIL 46106. ASTM C-920, ASTM G-26, MIL-46106.sdsadhesives-sealants
Design PolymericsDesign Polymerics DP 503 100% High Temperature RTV Silicone• ASTM C920 Type S, Grade NS, Class 25, Use NT, G, O • ASTM G26 • TT-S 001543A, TT-S 00230C Type II • FDA Regulation No. 21 CFR177.2600 • NSF Standard 51 • UL Recognized • MIL-46106 TYPE 1. QUV Testing (ASTM G26): Pass 10,000 hours. VOC: 23 g/lASTM C920, ASTM G26, MIL46106. ASTM C-920, ASTM G-26, MIL-46106. ASTM C 920, ASTM G 26, MIL 46106.tdsadhesives-sealants
Design PolymericsDesign Polymerics DP 503 100% High Temperature RTV Silicone• ASTM C920 Type S, Grade NS, Class 25, Use NT, G, O • ASTM G26 • TT-S 001543A, TT-S 00230C Type II • FDA Regulation No. 21 CFR177.2600 • NSF Standard 51 • UL Recognized • MIL-46106 TYPE 1. QUV Testing (ASTM G26): Pass 10,000 hours. VOC: 23 g/lASTM C920, ASTM G26, MIL46106. ASTM C-920, ASTM G-26, MIL-46106. ASTM C 920, ASTM G 26, MIL 46106.sdsadhesives-sealants
Design PolymericsDesign Polymerics DP 5050 Water Based Weather Barrier CoatingNFPA 90A & 90B, ASTM E-84, ASTM E-96, Color: White or Gray Base: Water Chemical Family: Synthetic Latex Solids Content: 66 ± 2% Viscosity: Approx. 110,000 - 130,000 cps Application Temperature: 40°F - 110°F Storage Temperature: 40°F - 110°F Service Temperature: -25°F - 200°F Freeze/Thaw Stability: Do not allow to freeze Flammability: Non-flammable wet or dry Flash Point: No flash to boiling Shelf Life: 1 Year (unopened containers) Cure Time: 24 to 72 hours depending on humidity, temperature, and application rate.NFPA 90A & 90B, ASTM E-84, ASTM E-96, DP-5050, DP5050tdsmastics-coating
Design PolymericsDesign Polymerics DP 5050 Water Based Weather Barrier CoatingNFPA 90A & 90B, ASTM E-84, ASTM E-96, Color: White or Gray Base: Water Chemical Family: Synthetic Latex Solids Content: 66 ± 2% Viscosity: Approx. 110,000 - 130,000 cps Application Temperature: 40°F - 110°F Storage Temperature: 40°F - 110°F Service Temperature: -25°F - 200°F Freeze/Thaw Stability: Do not allow to freeze Flammability: Non-flammable wet or dry Flash Point: No flash to boiling Shelf Life: 1 Year (unopened containers) Cure Time: 24 to 72 hours depending on humidity, temperature, and application rate.NFPA 90A & 90B, ASTM E-84, ASTM E-96, DP-5050, DP5050sdsmastics-coating
Design PolymericsDesign Polymerics DP 5060 Low Viscosity Water Based Weather Barrier CoatingASTM E-84, ASTM E-96, Color: White Base: Water Chemical Family: Synthetic Latex Solids Content: 66 ± 2% Viscosity: Approx. 75,000 - 90,000 cps Application Temperature: 40°F - 110°F Storage Temperature: 40°F - 110°F Service Temperature: -25°F - 200°F Freeze/Thaw Stability: Do not allow to freeze Flammability: Non-flammable wet or dry Flash Point: No flash to boiling Shelf Life: 1 Year (unopened containers) Cure Time: 24 to 72 hours depending on humidity, temperature, and application rateASTM E84, ASTM E96, ASTM E 84, ASTM E 96, ASTM E-84, ASTM E-96, DP-5060, DP5060tdsmastics-coating
Design PolymericsDesign Polymerics DP 5060 Low Viscosity Water Based Weather Barrier CoatingASTM E-84, ASTM E-96, Color: White Base: Water Chemical Family: Synthetic Latex Solids Content: 66 ± 2% Viscosity: Approx. 75,000 - 90,000 cps Application Temperature: 40°F - 110°F Storage Temperature: 40°F - 110°F Service Temperature: -25°F - 200°F Freeze/Thaw Stability: Do not allow to freeze Flammability: Non-flammable wet or dry Flash Point: No flash to boiling Shelf Life: 1 Year (unopened containers) Cure Time: 24 to 72 hours depending on humidity, temperature, and application rate.ASTM E84, ASTM E96, ASTM E 84, ASTM E 96, ASTM E-84, ASTM E-96, DP-5060, DP5060sdsmastics-coating
Design PolymericsDesign Polymerics DP 5060 Low Viscosity Weather Barrier Breather MasticNFPA 90A & 90B, ASTM E-84, ASTM E-96, Color: White Base: Water Chemical Family: Synthetic Latex Solids Content: 66 ± 2% Viscosity: Approx. 75,000 - 90,000 cps Application Temperature: 40°F - 110°F Storage Temperature: 40°F - 110°F Service Temperature: -25°F - 200°F Freeze/Thaw Stability: Do not allow to freeze Flammability: Non-flammable wet or dry Flash Point: No flash to boiling Shelf Life: 1 Year (unopened containers) Cure Time: 24 to 72 hours depending on humidity, temperature, and application rate.ASTM E84, ASTM E96, ASTM E 84, ASTM E 96, ASTM E-84, ASTM E-96, DP-5060, DP5060tdsmastics-coating
Design PolymericsDesign Polymerics DP 5060 Low Viscosity Weather Barrier Breather MasticNFPA 90A & 90B, ASTM E-84, ASTM E-96, Color: White Base: Water Chemical Family: Synthetic Latex Solids Content: 66 ± 2% Viscosity: Approx. 75,000 - 90,000 cps Application Temperature: 40°F - 110°F Storage Temperature: 40°F - 110°F Service Temperature: -25°F - 200°F Freeze/Thaw Stability: Do not allow to freeze Flammability: Non-flammable wet or dry Flash Point: No flash to boiling Shelf Life: 1 Year (unopened containers) Cure Time: 24 to 72 hours depending on humidity, temperature, and application rate.ASTM E84, ASTM E96, ASTM E 84, ASTM E 96, ASTM E-84, ASTM E-96, DP-5060, DP5060sdsmastics-coating
Design PolymericsDesign Polymerics DP 88 Spray Edge CoatingColor: Black Chemical Family: Synthetic rubber Application Temperature: 50°F - 110°F Service Temperature: 0°F to 200°F Flammability: Extremely Flammable Dry Time: Dries to touch in 3 to 5 minutes depending on humidity, temperature, substrate, and application thickness. Fully cures in 30 minutes. Coverage: Typical application will yield up to 400 lineal feet on 1 inch duct liner per can. Packaging: Net wt. 16 oz. cans supplied 12 cans per case Shelf Life: 1 Yeartdsadhesives-sealants
Design PolymericsDesign Polymerics DP 88 Spray Edge CoatingColor: Black Chemical Family: Synthetic rubber Application Temperature: 50°F - 110°F Service Temperature: 0°F to 200°F Flammability: Extremely Flammable Dry Time: Dries to touch in 3 to 5 minutes depending on humidity, temperature, substrate, and application thickness. Fully cures in 30 minutes. Coverage: Typical application will yield up to 400 lineal feet on 1 inch duct liner per can. Packaging: Net wt. 16 oz. cans supplied 12 cans per case Shelf Life: 1 Yearsdsadhesives-sealants
Design PolymericsDesign Polymerics DP 99 Degalvanizer Spraytdsadhesives-sealants
Design PolymericsDesign Polymerics DP 99 Degalvanizer Spraysdsadhesives-sealants
FosterFoster 30-36 AF Sealfas Coating (Fungus Resistant)AVERAGE WEIGHT / U.S. GALLON (ASTM D1475): 10.4 lbs. (1.25 kg/l) AVERAGE NON-VOLATILE (ASTM D2369): 40% by volume (51% by weight) SERVICE TEMPERATURE LIMITS: Temperature at coated surface. 0°F to 180°F (-18°C to 82°C) WATER VAPOR PERMEANCE (TYPICAL AVERAGE): ASTM F1249: 0.5 – 1.3 perms (0.9 metric perms) at 31 mils dry film thickness (0.8 mm) WET FLAMMABILITY: No flash to boiling: 212°F (100°C) FUNGAL RESISTANCE (ASTM D5590): Rating = 0 SURFACE BURNING CHARACTERISTICS (ASTM E84): Flame Spread: 10 Smoke Developed: 5. Sealfas® Coating 30-36AF It meets the performance requirements of MIL-A-3316C, Class 1, Grade A. -Meets NFPA 90A and 90B 25/50 requirements and is compatible with polystyrene and polyurethane foam insulations. -VOC Emissions and Content requirements to contribute to LEED v4 EQ Credit: Low Emitting Materials –Paints and Coatings. -VOC Content: 43 g/l, less water and exempt solvents.ASTM D1475, ASTM D2369, ASTM F1249, ASTM D5590, ASTM E84, MIL A3316C. ASTM D 1475, ASTM D 2369, ASTM F 1249, ASTM D 5590, ASTM E 84, MIL A 3316 C. ASTM D-1475, ASTM D-2369, ASTM F-1249, ASTM D-5590, ASTM E-84, MIL-A-3316C.tdsmastics-coating
FosterFoster 30-36 AF Sealfas Coating (Fungus Resistant)AVERAGE WEIGHT / U.S. GALLON (ASTM D1475): 10.4 lbs. (1.25 kg/l) AVERAGE NON-VOLATILE (ASTM D2369): 40% by volume (51% by weight) SERVICE TEMPERATURE LIMITS: Temperature at coated surface. 0°F to 180°F (-18°C to 82°C) WATER VAPOR PERMEANCE (TYPICAL AVERAGE): ASTM F1249: 0.5 – 1.3 perms (0.9 metric perms) at 31 mils dry film thickness (0.8 mm) WET FLAMMABILITY: No flash to boiling: 212°F (100°C) FUNGAL RESISTANCE (ASTM D5590): Rating = 0 SURFACE BURNING CHARACTERISTICS (ASTM E84): Flame Spread: 10 Smoke Developed: 5. Sealfas® Coating 30-36AF It meets the performance requirements of MIL-A-3316C, Class 1, Grade A. -Meets NFPA 90A and 90B 25/50 requirements and is compatible with polystyrene and polyurethane foam insulations. -VOC Emissions and Content requirements to contribute to LEED v4 EQ Credit: Low Emitting Materials –Paints and Coatings. -VOC Content: 43 g/l, less water and exempt solvents.ASTM D1475, ASTM D2369, ASTM F1249, ASTM D5590, ASTM E84, MIL A3316C. ASTM D 1475, ASTM D 2369, ASTM F 1249, ASTM D 5590, ASTM E 84, MIL A 3316 C. ASTM D-1475, ASTM D-2369, ASTM F-1249, ASTM D-5590, ASTM E-84, MIL-A-3316C.sdsmastics-coating
FosterFoster 30-36 Sealfas CoatingASTM D1475, ASTM D2369, ASTM F1249: 0.5 - 1.5 perms (0.9 metric perms) at 31 mils dry film thickness (0.8 mm), Temperature at coated surface 0ºF to 180ºF (-18ºC to 82ºC), WET FLAMMABILITY: No flash to boiling, 212ºF (100ºC), SURFACE BURNING CHARACTERISTICS (ASTM E84): Flame Spread: 10 Smoke Developed: 5, It is also used as a lagging and lap adhesive for canvas and glass lagging cloth.Sealfas® Coating meets the requirements of Military Specification MIL-A-3316C Class 1, Grade A. Select Foster 30-36 HF Sealfas® Coating where MIL-DTL3316D, Class 1 Grade A and listing on the MIL-3316 QPD are required. Sealfas® Coating is approved by the U.S. Coast Guard under 164.012. NFPA 90A and 90B 25/50. VOC Emissions and Content requirements to contribute to LEED v4. VOC Content: 15 g/l.ASTM D1475, ASTM D2369, ASTM F1249, ASTM E84, ASTM D-1475, ASTM D-2369, ASTM F-1249, ASTM E-84, ASTM D 1475, ASTM D 2369, ASTM F 1249, ASTM E 84.tdsmastics-coating
FosterFoster 30-36 Sealfas CoatingASTM D1475, ASTM D2369, ASTM F1249: 0.5 - 1.5 perms (0.9 metric perms) at 31 mils dry film thickness (0.8 mm), Temperature at coated surface 0ºF to 180ºF (-18ºC to 82ºC), WET FLAMMABILITY: No flash to boiling, 212ºF (100ºC), SURFACE BURNING CHARACTERISTICS (ASTM E84): Flame Spread: 10 Smoke Developed: 5, It is also used as a lagging and lap adhesive for canvas and glass lagging cloth. Sealfas® Coating meets the requirements of Military Specification MIL-A-3316C Class 1, Grade A. Select Foster 30-36 HF Sealfas® Coating where MIL-DTL 3316D, Class 1 Grade A and listing on the MIL-3316 QPD are required. Sealfas® Coating is approved by the U.S. Coast Guard under 164.012. NFPA 90A and 90B 25/50. VOC Emissions and Content requirements to contribute to LEED v4. VOC Content: 15 g/l.ASTM D1475, ASTM D2369, ASTM F1249, ASTM E84, ASTM D-1475, ASTM D-2369, ASTM F-1249, ASTM E-84, ASTM D 1475, ASTM D 2369, ASTM F 1249, ASTM E 84.sdsmastics-coating
FosterFoster 30-80 Vapor-Safe CoatingAVERAGE WEIGHT / U.S. GALLON (ASTM D1475): 11.5 lbs. (1.38 kg/l) AVERAGE NON-VOLATILE (ASTM D2369): 58% by volume (70% by weight) SERVICE TEMPERATURE LIMITS: Temperature at coated surface. -20°F to 180°F (-29°C to 82°C) WATER VAPOR PERMEANCE (TYPICAL AVERAGE): Tested with reinforcing mesh. ASTM E96, PROCEDURE A: 0.05 perms (0.03 metric perms) at 47 mils dft (1.2 mm) 0.03 perms (0.02 metric perms) at 73 mils dft (1.9 mm) ASTM F1249: 0.08 perms (0.05 metric perms) at 37 mils dry film thickness (0.94 mm). Tested at 100°F (38°C) and 90% RH. VAPOR-SAFE® COATING meets the permeance requirements of ASTM C755-19 for below ambient vapor retarder coatings. WET FLAMMABILITY: Flash Point: None to boiling, 212°F (100°C) SURFACE BURNING CHARACTERISTICS (ASTM E84): Flame Spread: 15 Smoke Developed: 30 VAPOR-SAFE® COATING meets NFPA 90A and 90B 25/50 requirements. VAPOR-SAFE® COATING meets the requirements of Military Specification MIL-PRF-19565C, Type II using method ASTM E96, Procedure A permeance and is QPD-19565 Listed. VOC Emissions and Content requirements to contribute to LEED v4 EQ Credit: Low Emitting Materials – Paints and Coatings. VOC Content: 33 g/l, less water and exempt solvents.ASTM D1475, ASTM D2369, ASTM E96, ASTM F1249, ASTM C755-19, ASTM E84, MIL-PRF-19565C, ASTM E96. ASTM D 1475, ASTM D 2369, ASTM E 96, ASTM F 1249, ASTM C 755 19, ASTM E 84, MIL PRF 19565 C, ASTM E 96. ASTM D-1475, ASTM D-2369, ASTM E-96, ASTM F-1249, ASTM C-755-19, ASTM E-84, MIL-PRF-19565-C, ASTM E-96. tdsmastics-coating
FosterFoster 30-80 Vapor-Safe CoatingAVERAGE WEIGHT / U.S. GALLON (ASTM D1475): 11.5 lbs. (1.38 kg/l) AVERAGE NON-VOLATILE (ASTM D2369): 58% by volume (70% by weight) SERVICE TEMPERATURE LIMITS: Temperature at coated surface. -20°F to 180°F (-29°C to 82°C) WATER VAPOR PERMEANCE (TYPICAL AVERAGE): Tested with reinforcing mesh. ASTM E96, PROCEDURE A: 0.05 perms (0.03 metric perms) at 47 mils dft (1.2 mm) 0.03 perms (0.02 metric perms) at 73 mils dft (1.9 mm) ASTM F1249: 0.08 perms (0.05 metric perms) at 37 mils dry film thickness (0.94 mm). Tested at 100°F (38°C) and 90% RH. VAPOR-SAFE® COATING meets the permeance requirements of ASTM C755-19 for below ambient vapor retarder coatings. WET FLAMMABILITY: Flash Point: None to boiling, 212°F (100°C) SURFACE BURNING CHARACTERISTICS (ASTM E84): Flame Spread: 15 Smoke Developed: 30 VAPOR-SAFE® COATING meets NFPA 90A and 90B 25/50 requirements. VAPOR-SAFE® COATING meets the requirements of Military Specification MIL-PRF-19565C, Type II using method ASTM E96, Procedure A permeance and is QPD-19565 Listed. VOC Emissions and Content requirements to contribute to LEED v4 EQ Credit: Low Emitting Materials – Paints and Coatings. VOC Content: 33 g/l, less water and exempt solvents.ASTM D1475, ASTM D2369, ASTM E96, ASTM F1249, ASTM C755-19, ASTM E84, MIL-PRF-19565C, ASTM E96. ASTM D 1475, ASTM D 2369, ASTM E 96, ASTM F 1249, ASTM C 755 19, ASTM E 84, MIL PRF 19565 C, ASTM E 96. ASTM D-1475, ASTM D-2369, ASTM E-96, ASTM F-1249, ASTM C-755-19, ASTM E-84, MIL-PRF-19565-C, ASTM E-96. sdsmastics-coating
FosterFoster 30-80 Vapor-Safe Coating AF (Fungus Resistant)AVERAGE WEIGHT / U.S. GALLON (ASTM D1475): 11.5 lbs. (1.38 kg/l) AVERAGE NON-VOLATILE (ASTM D2369): 58% by volume (70% by weight) SERVICE TEMPERATURE LIMITS: Temperature at coated surface. -20°F to 180°F (-29°C to 82°C) WATER VAPOR PERMEANCE (TYPICAL AVERAGE): Tested with reinforcing mesh. ASTM E96, PROCEDURE A: 0.05 perms (0.03 metric perms) at 47 mils dft (1.2 mm) 0.03 perms (0.02 metric perms) at 73 mils dft (1.9 mm) ASTM F1249: 0.08 perms (0.05 metric perms) at 37 mils dry film thickness (0.94 mm). Tested at 100°F (38°C) and 90% RH. VAPOR-SAFE® COATING meets the permeance requirements of ASTM C755-19 for below ambient vapor retarder coatings. WET FLAMMABILITY: Flash Point: None to boiling, 212°F (100°C) SURFACE BURNING CHARACTERISTICS (ASTM E84): Flame Spread: 15 Smoke Developed: 30 VAPOR-SAFE® COATING meets NFPA 90A and 90B 25/50requirements. VAPOR-SAFE® 30-80AF™ meets the requirements of Military Specification MIL-PRF-19565C, Type II using method ASTM E96, Procedure A permeance. VAPOR-SAFE® COATING 30-80AF meets the requirements of: VOC Emissions and Content requirements to contribute to LEED v4 EQ Credit: Low Emitting Materials – Paints and Coatings. VOC Content: 36 g/l, less water and exempt solvents. ASTM D1475, ASTM D2369, ASTM E96, ASTM F1249, ASTM C755-19, ASTM E84, MIL-PRF-19565C, ASTM E96. ASTM D 1475, ASTM D 2369, ASTM E 96, ASTM F 1249, ASTM C755 19, ASTM E 84, MIL PRF 19565 C, ASTM E 96. ASTM D-1475, ASTM D-2369, ASTM E-96, ASTM F-1249, ASTM C-755-19, ASTM E-84, MIL-PRF-19565C, ASTM E-96.tdsmastics-coating
FosterFoster 30-80 Vapor-Safe Coating AF (Fungus Resistant)AVERAGE WEIGHT / U.S. GALLON (ASTM D1475): 11.5 lbs. (1.38 kg/l) AVERAGE NON-VOLATILE (ASTM D2369): 58% by volume (70% by weight) SERVICE TEMPERATURE LIMITS: Temperature at coated surface. -20°F to 180°F (-29°C to 82°C) WATER VAPOR PERMEANCE (TYPICAL AVERAGE): Tested with reinforcing mesh. ASTM E96, PROCEDURE A: 0.05 perms (0.03 metric perms) at 47 mils dft (1.2 mm) 0.03 perms (0.02 metric perms) at 73 mils dft (1.9 mm) ASTM F1249: 0.08 perms (0.05 metric perms) at 37 mils dry film thickness (0.94 mm). Tested at 100°F (38°C) and 90% RH. VAPOR-SAFE® COATING meets the permeance requirements of ASTM C755-19 for below ambient vapor retarder coatings. WET FLAMMABILITY: Flash Point: None to boiling, 212°F (100°C) SURFACE BURNING CHARACTERISTICS (ASTM E84): Flame Spread: 15 Smoke Developed: 30 VAPOR-SAFE® COATING meets NFPA 90A and 90B 25/50requirements. VAPOR-SAFE® 30-80AF™ meets the requirements of Military Specification MIL-PRF-19565C, Type II using method ASTM E96, Procedure A permeance. VAPOR-SAFE® COATING 30-80AF meets the requirements of: VOC Emissions and Content requirements to contribute to LEED v4 EQ Credit: Low Emitting Materials – Paints and Coatings. VOC Content: 36 g/l, less water and exempt solvents. ASTM D1475, ASTM D2369, ASTM E96, ASTM F1249, ASTM C755-19, ASTM E84, MIL-PRF-19565C, ASTM E96. ASTM D 1475, ASTM D 2369, ASTM E 96, ASTM F 1249, ASTM C755 19, ASTM E 84, MIL PRF 19565 C, ASTM E 96. ASTM D-1475, ASTM D-2369, ASTM E-96, ASTM F-1249, ASTM C-755-19, ASTM E-84, MIL-PRF-19565C, ASTM E-96.sdsmastics-coating
FosterFoster 30-90 Vapor-Safe MasticAVERAGE WEIGHT/U.S. GALLON (ASTM D 1475): 11.5 pounds (1.38 Kg/l) AVERAGE NON-VOLATILE (ASTM D 2369): 59% by volume (71% by weight) SERVICE TEMPERATURE LIMITS: (Temperature at coated surface) -20°F to 180°F (-29°C to 82°C) WATER VAPOR PERMEANCE: ASTM E 96 Procedure B, 0.013 perms (0.009/metric perms) at 43 mils dry (1.09 mm)ASTM F 1249, 0.08 perms (0.05 metric perms) at 37 mils dry (0.94 mm). Tested at 100°F (38°C) and 90% RH. WET FLAMMABILITY: Flash point: None to boiling, 212°F (100°C). SURFACE BURNING CHARACTERISTICS(ASTM E 84): Flame Spread: 15 Smoke Developed: 30. VAPOR-SAFE MASTIC meets requirements for LEED IEQ 4.2 Low-Emitting Materials, Paints and Coatings. VOC: 36 g/l, less water and exempt solvents. Meets the requirements of Military Specification MIL-PRF-19565C, Type II and is listed on the QPD19565. Meets NFPA 90A and 90B 25/50 requirements.ASTM D 1475, ASTM D 2369, ASTM E 96, ASTM F 1249, ASTM E 84, MIL PRF 19565C, QPD 19565. ASTM D-1475, ASTM D-2369, ASTM E-96, ASTM F-1249, ASTM E-84, MIL-PRF-19565-C, QPD-19565. ASTM D1475, ASTM D2369, ASTM E96, ASTM F1249, ASTM E84, MIL PRF19565C, QPD19565. tdsmastics-coating
FosterFoster 30-90 Vapor-Safe MasticAVERAGE WEIGHT/U.S. GALLON (ASTM D 1475): 11.5 pounds (1.38 Kg/l) AVERAGE NON-VOLATILE (ASTM D 2369): 59% by volume (71% by weight) SERVICE TEMPERATURE LIMITS: (Temperature at coated surface) -20°F to 180°F (-29°C to 82°C) WATER VAPOR PERMEANCE: ASTM E 96 Procedure B, 0.013 perms (0.009/metric perms) at 43 mils dry (1.09 mm)ASTM F 1249, 0.08 perms (0.05 metric perms) at 37 mils dry (0.94 mm). Tested at 100°F (38°C) and 90% RH. WET FLAMMABILITY: Flash point: None to boiling, 212°F (100°C). SURFACE BURNING CHARACTERISTICS(ASTM E 84): Flame Spread: 15 Smoke Developed: 30. VAPOR-SAFE MASTIC meets requirements for LEED IEQ 4.2 Low-Emitting Materials, Paints and Coatings. VOC: 36 g/l, less water and exempt solvents. Meets the requirements of Military Specification MIL-PRF-19565C, Type II and is listed on the QPD19565. Meets NFPA 90A and 90B 25/50 requirements.ASTM D 1475, ASTM D 2369, ASTM E 96, ASTM F 1249, ASTM E 84, MIL PRF 19565C, QPD 19565. ASTM D-1475, ASTM D-2369, ASTM E-96, ASTM F-1249, ASTM E-84, MIL-PRF-19565-C, QPD-19565. ASTM D1475, ASTM D2369, ASTM E96, ASTM F1249, ASTM E84, MIL PRF19565C, QPD19565. sdsmastics-coating
FosterFoster 32-17 Safetee Duct SealantAVERAGE WEIGHT / U.S. GALLON (ASTM D1475): 11.6 lbs. (1.35 kg/l) AVERAGE NON-VOLATILE (ASTM D2369): 55% by volume (69% by weight) SERVICE TEMPERATURE LIMITS: 20ºF to 200ºF (-7ºC to 93ºC) DRYING TIME 73ºF (23ºC) 50% RH: Set to Touch: 1 hour Dry Through: 24 hours SHORE HARDNESS (ASTM D2240): Type A: 80 WATER VAPOR PERMEANCE (TYPICAL AVERAGE): ASTM E96, PROCEDURE A: 0.45 perms (0.30 metric perms) at 35 mils (0.9 mm) dry thickness WET FLAMMABILITY: No flash to boiling, over 210ºF (99ºC) SURFACE BURNING CHARACTERISTICS (ASTM E84): Flame Spread: 5 Smoke Developed: 0 SAFETEE™ DUCT SEALANT Meets NFPA 90A and 90B 25/50 requirements. It is approved for use in the City of Los Angeles, application number M-960081. SAFETEE™ DUCT SEALANT 32-17 meets the requirements VOC Emissions and Content requirements to contribute to LEED v4 EQ Credit: Low Emitting Materials – Paints and Coatings. VOC Content: 45 g/l, less water and exempt solvents.ASTM D1475, ASTM D2369, ASTM D2240, ASTM E96, ASTM E84, M-960081. ASTM D 1475, ASTM D 2369, ASTM D 2240, ASTM E 96, ASTM E 84, M 960081. ASTM D-1475, ASTM D-2369, ASTM D-2240, ASTM E-96, ASTM E-84, M960081. sdsmastics-coating
FosterFoster 32-17 Safetee Duct SealantAVERAGE WEIGHT / U.S. GALLON (ASTM D1475): 11.6 lbs. (1.35 kg/l) AVERAGE NON-VOLATILE (ASTM D2369): 55% by volume (69% by weight) SERVICE TEMPERATURE LIMITS: 20ºF to 200ºF (-7ºC to 93ºC) DRYING TIME 73ºF (23ºC) 50% RH: Set to Touch: 1 hour Dry Through: 24 hours SHORE HARDNESS (ASTM D2240): Type A: 80 WATER VAPOR PERMEANCE (TYPICAL AVERAGE): ASTM E96, PROCEDURE A: 0.45 perms (0.30 metric perms) at 35 mils (0.9 mm) dry thickness WET FLAMMABILITY: No flash to boiling, over 210ºF (99ºC) SURFACE BURNING CHARACTERISTICS (ASTM E84): Flame Spread: 5 Smoke Developed: 0 SAFETEE™ DUCT SEALANT Meets NFPA 90A and 90B 25/50 requirements. It is approved for use in the City of Los Angeles, application number M-960081. SAFETEE™ DUCT SEALANT 32-17 meets the requirements VOC Emissions and Content requirements to contribute to LEED v4 EQ Credit: Low Emitting Materials – Paints and Coatings. VOC Content: 45 g/l, less water and exempt solvents.ASTM D1475, ASTM D2369, ASTM D2240, ASTM E96, ASTM E84, M-960081. ASTM D 1475, ASTM D 2369, ASTM D 2240, ASTM E 96, ASTM E 84, M 960081. ASTM D-1475, ASTM D-2369, ASTM D-2240, ASTM E-96, ASTM E-84, M960081. tdsmastics-coating
FosterFoster 32-19 Duct-Fas Duct SealantAVERAGE WEIGHT / U.S. GALLON (ASTM D1475): 11.7 pounds (1.40 kg/l) AVERAGE NON-VOLATILE (ASTM D 2369): 56% by volume (70% by weight) COVERAGE RANGE (FSTM 72): Brush: 50 sq. ft./gal (1.2 m2/l) 0.032 in. (0.8 mm) wet film thickness DRYING TIME 73ºF (23ºC) 50% RH (ASTM D 1640): Set to Touch: 1 hour Dry Through: 16 hours SERVICE TEMPERATURE LIMITS (FSTM 165): 20ºF to 200ºF (-7ºC to 93ºC) FUNGAL GROWTH RESISTANCE (ASTM G 21): Rating=0, no fungal growth on surface. SHORE HARDNESS (ASTM D 2240): Type A: 72 WET FLAMMABILITY (ASTM D 3828): No flash to boiling, over 210ºF (99ºC) SURFACE BURNING CHARACTERISTICS (ASTM E 84): Flame Spread: 0 Smoke Developed: 0 Duct-Fas Duct Sealant is produced under the classification and follow-up service of Underwriter’s Laboratories, Inc. and meets NFPA 90A and 90B 25/50 requirements. It is approved for use in the City of Los Angeles, application number M-960057. Duct-Fas Duct Sealant is approved by the U.S. Coast Guard under 164.012. It contains no asbestos, lead, mercury, or mercury compounds. Duct-Fas Duct Sealant meets requirements for LEED IEQ 4.1 Low-Emitting Materials, Adhesives and Sealants. VOC: 24 g/l, less water and exempt solvents. Duct-Fas Duct Sealant will meet all SMACNA pressure classes up to 10″ w.g.ASTM D1475, ASTM D2369, FSTM72, ASTM D1640, FSTM165, ASTM G21, ASTM D2240, ASTM D3828, ASTM E84, M960057, 164.012. ASTM D 1475, ASTM D 2369, FSTM 72, ASTM D 1640, FSTM 165, ASTM G 21, ASTM D 2240, ASTM D 3828, ASTM E 84, M-960057, 164.012. ASTM D1475, ASTM D 2369, FSTM 72, ASTM D 1640, FSTM 165, ASTM G 21, ASTM D 2240, ASTM D 3828, ASTM E 84, M-960057, 164.012. ASTM D-1475, ASTM D-2369, FSTM-72, ASTM D-1640, FSTM-165, ASTM G-21, ASTM D-2240, ASTM D-3828, ASTM E-84, M-960057, 164.012. tdsmastics-coating
FosterFoster 32-19 Duct-Fas Duct SealantAVERAGE WEIGHT / U.S. GALLON (ASTM D1475): 11.7 pounds (1.40 kg/l) AVERAGE NON-VOLATILE (ASTM D 2369): 56% by volume (70% by weight) COVERAGE RANGE (FSTM 72): Brush: 50 sq. ft./gal (1.2 m2/l) 0.032 in. (0.8 mm) wet film thickness DRYING TIME 73ºF (23ºC) 50% RH (ASTM D 1640): Set to Touch: 1 hour Dry Through: 16 hours SERVICE TEMPERATURE LIMITS (FSTM 165): 20ºF to 200ºF (-7ºC to 93ºC) FUNGAL GROWTH RESISTANCE (ASTM G 21): Rating=0, no fungal growth on surface. SHORE HARDNESS (ASTM D 2240): Type A: 72 WET FLAMMABILITY (ASTM D 3828): No flash to boiling, over 210ºF (99ºC) SURFACE BURNING CHARACTERISTICS (ASTM E 84): Flame Spread: 0 Smoke Developed: 0 Duct-Fas Duct Sealant is produced under the classification and follow-up service of Underwriter’s Laboratories, Inc. and meets NFPA 90A and 90B 25/50 requirements. It is approved for use in the City of Los Angeles, application number M-960057. Duct-Fas Duct Sealant is approved by the U.S. Coast Guard under 164.012. It contains no asbestos, lead, mercury, or mercury compounds. Duct-Fas Duct Sealant meets requirements for LEED IEQ 4.1 Low-Emitting Materials, Adhesives and Sealants. VOC: 24 g/l, less water and exempt solvents. Duct-Fas Duct Sealant will meet all SMACNA pressure classes up to 10″ w.g.ASTM D1475, ASTM D2369, FSTM72, ASTM D1640, FSTM165, ASTM G21, ASTM D2240, ASTM D3828, ASTM E84, M960057, 164.012. ASTM D 1475, ASTM D 2369, FSTM 72, ASTM D 1640, FSTM 165, ASTM G 21, ASTM D 2240, ASTM D 3828, ASTM E 84, M-960057, 164.012. ASTM D1475, ASTM D 2369, FSTM 72, ASTM D 1640, FSTM 165, ASTM G 21, ASTM D 2240, ASTM D 3828, ASTM E 84, M-960057, 164.012. ASTM D-1475, ASTM D-2369, FSTM-72, ASTM D-1640, FSTM-165, ASTM G-21, ASTM D-2240, ASTM D-3828, ASTM E-84, M-960057, 164.012. sdsmastics-coating
FosterFoster 35-00 SEALFAS G-P-M MASTICAVERAGE WEIGHT/U.S. GALLON (ASTM D1475): 11.6 lbs. (1.39 kg/l) AVERAGE NON-VOLATILE (ASTM D2369): 63-65% by volume (73-75% by weight) SERVICE TEMPERATURE LIMITS: Temperature at coated surface. -20°F to 200°F (-29°C to 93°C) WATER VAPOR PERMEANCE (TYPICAL AVERAGE): ASTM F1249: 3.0 perms (2.0 metric perms) at 1/16 inch (1.6mm) dry film thickness; decreasing on aging to 1.0 perm (0.7metric perm) WET FLAMMABILITY: No flash to boiling, 205°F (96° C) SURFACE BURNING CHARACTERISTICS (ASTM E84): Flame Spread: 20 Smoke Developed: 25-50. Sealfas G-P-M® Mastic meets NFPA 90A & 90B 25/50 requirements. Nuclear Grade Sealfas G-P-M® Mastic 35-00Q and 45-00Q can be supplied to meet the stress corrosion and chemical analysis requirements of MIL-I-24244C or nuclear regulatory guide 1.36 on special order. Sealfas G-P-M® Mastic 35-00/45-00™ meets the requirements of: -VOC Emissions and Content requirements to contribute to LEED v4 EQ Credit: Low Emitting Materials –Paints and Coatings -VOC Content: <50 g/l, less water and exempt solvents. ASTM D1475, ASTM D2369, ASTM F1249, ASTM E84, MIL-I-24244C. ASTM D-1475, ASTM D-2369, ASTM F-1249, ASTM E-84, MIL I24244C. ASTM D 1475, ASTM D 2369, ASTM F 1249, ASTM E 84, MIL I 24244C tdsmastics-coating
FosterFoster 35-00 SEALFAS G-P-M MASTICAVERAGE WEIGHT/U.S. GALLON (ASTM D1475): 11.6 lbs. (1.39 kg/l) AVERAGE NON-VOLATILE (ASTM D2369): 63-65% by volume (73-75% by weight) SERVICE TEMPERATURE LIMITS: Temperature at coated surface. -20°F to 200°F (-29°C to 93°C) WATER VAPOR PERMEANCE (TYPICAL AVERAGE): ASTM F1249: 3.0 perms (2.0 metric perms) at 1/16 inch (1.6mm) dry film thickness; decreasing on aging to 1.0 perm (0.7metric perm) WET FLAMMABILITY: No flash to boiling, 205°F (96° C) SURFACE BURNING CHARACTERISTICS (ASTM E84): Flame Spread: 20 Smoke Developed: 25-50. Sealfas G-P-M® Mastic meets NFPA 90A & 90B 25/50 requirements. Nuclear Grade Sealfas G-P-M® Mastic 35-00Q and 45-00Q can be supplied to meet the stress corrosion and chemical analysis requirements of MIL-I-24244C or nuclear regulatory guide 1.36 on special order. Sealfas G-P-M® Mastic 35-00/45-00™ meets the requirements of: -VOC Emissions and Content requirements to contribute to LEED v4 EQ Credit: Low Emitting Materials –Paints and Coatings -VOC Content: <50 g/l, less water and exempt solvents. ASTM D1475, ASTM D2369, ASTM F1249, ASTM E84, MIL-I-24244C. ASTM D-1475, ASTM D-2369, ASTM F-1249, ASTM E-84, MIL I24244C. ASTM D 1475, ASTM D 2369, ASTM F 1249, ASTM E 84, MIL I 24244C sdsmastics-coating
FosterFoster 40-90 First Defense Disinfectant ConcentrateAVERAGE WEIGHT/U.S. GALLON (ASTM D1475): 8.4 lbs. (1.01 kg/l), ALKALINITY (ASTM E70): 12 – 13.5 pH SAFETY: Wet flammability (ASTM D3278) No flash to boiling, 212ºF (100ºC), ASTM D1475, ASTM E70, ASTM D3278. ASTM D 1475, ASTM E 70, ASTM D 3278. ASTM D-1475, ASTM E-70, ASTM D-3278.tdsmastics-coating
FosterFoster 40-90 First Defense Disinfectant ConcentrateAVERAGE WEIGHT/U.S. GALLON (ASTM D1475): 8.4 lbs. (1.01 kg/l), ALKALINITY (ASTM E70): 12 – 13.5 pH SAFETY: Wet flammability (ASTM D3278) No flash to boiling, 212ºF (100ºC), ASTM D1475, ASTM E70, ASTM D3278. ASTM D 1475, ASTM E 70, ASTM D 3278. ASTM D-1475, ASTM E-70, ASTM D-3278.sdsmastics-coating
FosterFoster 60-38 MONOLAR MASTICAVERAGE WEIGHT / U.S. GALLON (ASTM D1475): 8.8 to 9.3 lbs. (1.05 to 1.11 kg/l) AVERAGE NON-VOLATILE (ASTM D2369): 30% by volume (43% by weight) SERVICE TEMPERATURE LIMITS: Temperature at coated surface. -40°F to 250°F (-40°C to 121°C) WATER VAPOR PERMEANCE (TYPICAL AVERAGE): Tested with reinforcing mesh. -ASTM E96, PROCEDURE A: 0.04 perms (0.03 metric perms) at 46 mils dry (1.17 mm). -ASTM E96, PROCEDURE E: 0.011 perms (0.007 metric perms) at 50 mils dry (1.27 mm). -ASTM F1249: 0.047 perms (0.031 metric perms) at 46 mils dry (1.17 mm). Tested at 75°F (24°C) and 50% RH. MONOLAR II MASTIC meets the permeance requirements of ASTM C755-19 for below ambient vapor retarder coatings. WET FLAMMABILITY: Flash Point: 110°F (43°C) SURFACE BURNING CHARACTERISTICS (ASTM E84): Flame Spread: 20 Smoke Developed: 10 – 40. MONOLAR II MASTIC meets NFPA 90A and 90B 25/50 requirements.ASTM D1475, ASTM D2369, ASTM E96, ASTM E96, ASTM F1249, ASTM C755-19, ASTM E84. ASTM D 1475, ASTM D 2369, ASTM E 96, ASTM E 96, ASTM F 1249, ASTM C755 19, ASTM E 84. ASTM D-1475, ASTM D-2369, ASTM E-96, ASTM E-96, ASTM F-1249, ASTM C755-19, ASTM E-84. tdsmastics-coating
FosterFoster 60-38 MONOLAR MASTICAVERAGE WEIGHT / U.S. GALLON (ASTM D1475): 8.8 to 9.3 lbs. (1.05 to 1.11 kg/l) AVERAGE NON-VOLATILE (ASTM D2369): 30% by volume (43% by weight) SERVICE TEMPERATURE LIMITS: Temperature at coated surface. -40°F to 250°F (-40°C to 121°C) WATER VAPOR PERMEANCE (TYPICAL AVERAGE): Tested with reinforcing mesh. -ASTM E96, PROCEDURE A: 0.04 perms (0.03 metric perms) at 46 mils dry (1.17 mm). -ASTM E96, PROCEDURE E: 0.011 perms (0.007 metric perms) at 50 mils dry (1.27 mm). -ASTM F1249: 0.047 perms (0.031 metric perms) at 46 mils dry (1.17 mm). Tested at 75°F (24°C) and 50% RH. MONOLAR II MASTIC meets the permeance requirements of ASTM C755-19 for below ambient vapor retarder coatings. WET FLAMMABILITY: Flash Point: 110°F (43°C) SURFACE BURNING CHARACTERISTICS (ASTM E84): Flame Spread: 20 Smoke Developed: 10 – 40. MONOLAR II MASTIC meets NFPA 90A and 90B 25/50 requirements.ASTM D1475, ASTM D2369, ASTM E96, ASTM E96, ASTM F1249, ASTM C755-19, ASTM E84. ASTM D 1475, ASTM D 2369, ASTM E 96, ASTM E 96, ASTM F 1249, ASTM C755 19, ASTM E 84. ASTM D-1475, ASTM D-2369, ASTM E-96, ASTM E-96, ASTM F-1249, ASTM C755-19, ASTM E-84. sdsmastics-coating
FosterFoster 60-39 MONOLAR MASTICAVERAGE WEIGHT / U.S. GALLON (ASTM D1475): 8.8 to 9.3 lbs. (1.05 to 1.11 kg/l) AVERAGE NON-VOLATILE (ASTM D2369): 30% by volume (43% by weight) SERVICE TEMPERATURE LIMITS: Temperature at coated surface. -40°F to 250°F (-40°C to 121°C) WATER VAPOR PERMEANCE (TYPICAL AVERAGE): Tested with reinforcing mesh. -ASTM E96, PROCEDURE A: 0.04 perms (0.03 metric perms) at 46 mils dry (1.17 mm). -ASTM E96, PROCEDURE E: 0.011 perms (0.007 metric perms) at 50 mils dry (1.27 mm). -ASTM F1249: 0.047 perms (0.031 metric perms) at 46 mils dry (1.17 mm). Tested at 75°F (24°C) and 50% RH. MONOLAR II MASTIC meets the permeance requirements of ASTM C755-19 for below ambient vapor retarder coatings. WET FLAMMABILITY: Flash Point: 110°F (43°C) SURFACE BURNING CHARACTERISTICS (ASTM E84): Flame Spread: 20 Smoke Developed: 10 – 40. MONOLAR II MASTIC meets NFPA 90A and 90B 25/50 requirements.ASTM D1475, ASTM D2369, ASTM E96, ASTM E96, ASTM F1249, ASTM C755-19, ASTM E84. ASTM D 1475, ASTM D 2369, ASTM E 96, ASTM E 96, ASTM F 1249, ASTM C755 19, ASTM E 84. ASTM D-1475, ASTM D-2369, ASTM E-96, ASTM E-96, ASTM F-1249, ASTM C755-19, ASTM E-84. tdsmastics-coating
FosterFoster 60-39 MONOLAR MASTICAVERAGE WEIGHT / U.S. GALLON (ASTM D1475): 8.8 to 9.3 lbs. (1.05 to 1.11 kg/l) AVERAGE NON-VOLATILE (ASTM D2369): 30% by volume (43% by weight) SERVICE TEMPERATURE LIMITS: Temperature at coated surface. -40°F to 250°F (-40°C to 121°C) WATER VAPOR PERMEANCE (TYPICAL AVERAGE): Tested with reinforcing mesh. -ASTM E96, PROCEDURE A: 0.04 perms (0.03 metric perms) at 46 mils dry (1.17 mm). -ASTM E96, PROCEDURE E: 0.011 perms (0.007 metric perms) at 50 mils dry (1.27 mm). -ASTM F1249: 0.047 perms (0.031 metric perms) at 46 mils dry (1.17 mm). Tested at 75°F (24°C) and 50% RH. MONOLAR II MASTIC meets the permeance requirements of ASTM C755-19 for below ambient vapor retarder coatings. WET FLAMMABILITY: Flash Point: 110°F (43°C) SURFACE BURNING CHARACTERISTICS (ASTM E84): Flame Spread: 20 Smoke Developed: 10 – 40. MONOLAR II MASTIC meets NFPA 90A and 90B 25/50 requirements.ASTM D1475, ASTM D2369, ASTM E96, ASTM E96, ASTM F1249, ASTM C755-19, ASTM E84. ASTM D 1475, ASTM D 2369, ASTM E 96, ASTM E 96, ASTM F 1249, ASTM C755 19, ASTM E 84. ASTM D-1475, ASTM D-2369, ASTM E-96, ASTM E-96, ASTM F-1249, ASTM C755-19, ASTM E-84. sdsmastics-coating
FosterFOSTER 60-90 MONOLAR MASTICAVERAGE WEIGHT / U.S. GALLON (ASTM D1475): 10.4 to 10.8 lbs. (1.25 to 1.30 kg/l) AVERAGE NON-VOLATILE (ASTM D2369): 42% by volume (60% by weight) SERVICE TEMPERATURE LIMITS: Temperature at coated surface. -50°F to 220°F (-46°C to 104°C) WATER VAPOR PERMEANCE (TYPICAL AVERAGE): Tested with reinforcing mesh. -ASTM E96, PROCEDURE A: 0.03 perms (0.02 metric perms) at 45 mils dry (1.14 mm). -ASTM E96, PROCEDURE E: 0.025 perms (0.016 metric perms) at 51 mils dry (1.3 mm). -ASTM F1249: 0.039 perms (0.026 metric perms) at 45 mils dry (1.14 mm). Tested at 75°F (24°C) and 50% RH. MONOLAR MASTIC meets the permeance requirements of ASTM C755-19 for below ambient vapor retarder coatings. WET FLAMMABILITY (ASTM D93): Flash Point: 124°F (43°C) SURFACE BURNING CHARACTERISTICS (ASTM E84): Flame Spread: 10 Smoke Developed: 15ASTM D1475, ASTM D2369, ASTM E96, ASTM F1249, ASTM C755-19, ASTM D93, ASTM E84. ASTM D 1475, ASTM D 2369, ASTM E 96, ASTM F 1249, ASTM C 755 19, ASTM D 93, ASTM E 84. ASTM D-1475, ASTM D-2369, ASTM E-96, ASTM F-1249, ASTM C-755-19, ASTM D-93, ASTM E-84.tdsmastics-coating
FosterFOSTER 60-90 MONOLAR MASTICAVERAGE WEIGHT / U.S. GALLON (ASTM D1475): 10.4 to 10.8 lbs. (1.25 to 1.30 kg/l) AVERAGE NON-VOLATILE (ASTM D2369): 42% by volume (60% by weight) SERVICE TEMPERATURE LIMITS: Temperature at coated surface. -50°F to 220°F (-46°C to 104°C) WATER VAPOR PERMEANCE (TYPICAL AVERAGE): Tested with reinforcing mesh. -ASTM E96, PROCEDURE A: 0.03 perms (0.02 metric perms) at 45 mils dry (1.14 mm). -ASTM E96, PROCEDURE E: 0.025 perms (0.016 metric perms) at 51 mils dry (1.3 mm). -ASTM F1249: 0.039 perms (0.026 metric perms) at 45 mils dry (1.14 mm). Tested at 75°F (24°C) and 50% RH. MONOLAR MASTIC meets the permeance requirements of ASTM C755-19 for below ambient vapor retarder coatings. WET FLAMMABILITY (ASTM D93): Flash Point: 124°F (43°C) SURFACE BURNING CHARACTERISTICS (ASTM E84): Flame Spread: 10 Smoke Developed: 15ASTM D1475, ASTM D2369, ASTM E96, ASTM F1249, ASTM C755-19, ASTM D93, ASTM E84. ASTM D 1475, ASTM D 2369, ASTM E 96, ASTM F 1249, ASTM C 755 19, ASTM D 93, ASTM E 84. ASTM D-1475, ASTM D-2369, ASTM E-96, ASTM F-1249, ASTM C-755-19, ASTM D-93, ASTM E-84.sdsmastics-coating
FosterFOSTER 60-91 MONOLAR MASTICAVERAGE WEIGHT / U.S. GALLON (ASTM D1475): 10.4 to 10.8 lbs. (1.25 to 1.30 kg/l) AVERAGE NON-VOLATILE (ASTM D2369): 42% by volume (60% by weight) SERVICE TEMPERATURE LIMITS: Temperature at coated surface. -50°F to 220°F (-46°C to 104°C) WATER VAPOR PERMEANCE (TYPICAL AVERAGE): Tested with reinforcing mesh. -ASTM E96, PROCEDURE A: 0.03 perms (0.02 metric perms) at 45 mils dry (1.14 mm). -ASTM E96, PROCEDURE E: 0.025 perms (0.016 metric perms) at 51 mils dry (1.3 mm). -ASTM F1249: 0.039 perms (0.026 metric perms) at 45 mils dry (1.14 mm). Tested at 75°F (24°C) and 50% RH. MONOLAR MASTIC meets the permeance requirements of ASTM C755-19 for below ambient vapor retarder coatings. WET FLAMMABILITY (ASTM D93): Flash Point: 124°F (43°C) SURFACE BURNING CHARACTERISTICS (ASTM E84): Flame Spread: 10 Smoke Developed: 15ASTM D1475, ASTM D2369, ASTM E96, ASTM F1249, ASTM C755-19, ASTM D93, ASTM E84. ASTM D 1475, ASTM D 2369, ASTM E 96, ASTM F 1249, ASTM C 755 19, ASTM D 93, ASTM E 84. ASTM D-1475, ASTM D-2369, ASTM E-96, ASTM F-1249, ASTM C-755-19, ASTM D-93, ASTM E-84.tdsmastics-coating
FosterFOSTER 60-91 MONOLAR MASTICAVERAGE WEIGHT / U.S. GALLON (ASTM D1475): 10.4 to 10.8 lbs. (1.25 to 1.30 kg/l) AVERAGE NON-VOLATILE (ASTM D2369): 42% by volume (60% by weight) SERVICE TEMPERATURE LIMITS: Temperature at coated surface. -50°F to 220°F (-46°C to 104°C) WATER VAPOR PERMEANCE (TYPICAL AVERAGE): Tested with reinforcing mesh. -ASTM E96, PROCEDURE A: 0.03 perms (0.02 metric perms) at 45 mils dry (1.14 mm). -ASTM E96, PROCEDURE E: 0.025 perms (0.016 metric perms) at 51 mils dry (1.3 mm). -ASTM F1249: 0.039 perms (0.026 metric perms) at 45 mils dry (1.14 mm). Tested at 75°F (24°C) and 50% RH. MONOLAR MASTIC meets the permeance requirements of ASTM C755-19 for below ambient vapor retarder coatings. WET FLAMMABILITY (ASTM D93): Flash Point: 124°F (43°C) SURFACE BURNING CHARACTERISTICS (ASTM E84): Flame Spread: 10 Smoke Developed: 15ASTM D1475, ASTM D2369, ASTM E96, ASTM F1249, ASTM C755-19, ASTM D93, ASTM E84. ASTM D 1475, ASTM D 2369, ASTM E 96, ASTM F 1249, ASTM C 755 19, ASTM D 93, ASTM E 84. ASTM D-1475, ASTM D-2369, ASTM E-96, ASTM F-1249, ASTM C-755-19, ASTM D-93, ASTM E-84.sdsmastics-coating
FosterFoster 60-95 MONOLAR COATINGAVERAGE WEIGHT / U.S. GALLON (ASTM D1475): 9.5 to 9.9 lbs. (1.14 to 1.19 kg/l) AVERAGE NON-VOLATILE (ASTM D2369): 33% by volume (46% by weight) SERVICE TEMPERATURE LIMITS: Temperature at coated surface. -50°F to 220°F (-46°C to 104°C) WATER VAPOR PERMEANCE (TYPICAL AVERAGE): ASTM E96, PROCEDURE E: 0.025 perms (0.016 metric perms) at 51 mils dry (1.3 mm). ASTM E96, PROCEDURE A: 0.018 perms (0.012 metric perms) at 26 mils dry (0.66 mm). ASTM F1249: 0.05 perms (0.033 metric perms) at 30 mils dry (0.8 mm). Tested at 100°F (38°C) and 90% RH. MONOLAR COATING meets the permeance requirements of ASTM C755-19 for below ambient vapor retarder coatings. WET FLAMMABILITY (ASTM D93): Flash Point: 132°F (56°C) SURFACE BURNING CHARACTERISTICS (ASTM E84): Flame Spread: 10 Smoke Developed: 15. MONOLAR COATING meets NFPA 90A and 90B 25/50 requirements.ASTM D1475, ASTM D2369, ASTM E96, ASTM F1249, ASTM C755-19, ASTM D93, ASTM E84. ASTM D 1475, ASTM D 2369, ASTM E 96, ASTM F 1249, ASTM C 755 19, ASTM D 93, ASTM E 84. ASTM D-1475, ASTM D-2369, ASTM E-96, ASTM F-1249, ASTM C-755-19, ASTM D-93, ASTM E-84tdsmastics-coating
FosterFoster 60-95 MONOLAR COATINGAVERAGE WEIGHT / U.S. GALLON (ASTM D1475): 9.5 to 9.9 lbs. (1.14 to 1.19 kg/l) AVERAGE NON-VOLATILE (ASTM D2369): 33% by volume (46% by weight) SERVICE TEMPERATURE LIMITS: Temperature at coated surface. -50°F to 220°F (-46°C to 104°C) WATER VAPOR PERMEANCE (TYPICAL AVERAGE): ASTM E96, PROCEDURE E: 0.025 perms (0.016 metric perms) at 51 mils dry (1.3 mm). ASTM E96, PROCEDURE A: 0.018 perms (0.012 metric perms) at 26 mils dry (0.66 mm). ASTM F1249: 0.05 perms (0.033 metric perms) at 30 mils dry (0.8 mm). Tested at 100°F (38°C) and 90% RH. MONOLAR COATING meets the permeance requirements of ASTM C755-19 for below ambient vapor retarder coatings. WET FLAMMABILITY (ASTM D93): Flash Point: 132°F (56°C) SURFACE BURNING CHARACTERISTICS (ASTM E84): Flame Spread: 10 Smoke Developed: 15. MONOLAR COATING meets NFPA 90A and 90B 25/50 requirements.ASTM D1475, ASTM D2369, ASTM E96, ASTM F1249, ASTM C755-19, ASTM D93, ASTM E84. ASTM D 1475, ASTM D 2369, ASTM E 96, ASTM F 1249, ASTM C 755 19, ASTM D 93, ASTM E 84. ASTM D-1475, ASTM D-2369, ASTM E-96, ASTM F-1249, ASTM C-755-19, ASTM D-93, ASTM E-84sdsmastics-coating
FosterFoster 60-96 Monolar CoatingAVERAGE WEIGHT / U.S. GALLON (ASTM D1475): 9.5 to 9.9 lbs. (1.14 to 1.19 kg/l) AVERAGE NON-VOLATILE (ASTM D2369): 33% by volume (46% by weight) SERVICE TEMPERATURE LIMITS: Temperature at coated surface. -50°F to 220°F (-46°C to 104°C) WATER VAPOR PERMEANCE (TYPICAL AVERAGE): ASTM E96, PROCEDURE E: 0.025 perms (0.016 metric perms) at 51 mils dry (1.3 mm). ASTM E96, PROCEDURE A: 0.018 perms (0.012 metric perms) at 26 mils dry (0.66 mm). ASTM F1249: 0.05 perms (0.033 metric perms) at 30 mils dry (0.8 mm). Tested at 100°F (38°C) and 90% RH. MONOLAR COATING meets the permeance requirements of ASTM C755-19 for below ambient vapor retarder coatings. WET FLAMMABILITY (ASTM D93): Flash Point: 132°F (56°C) SURFACE BURNING CHARACTERISTICS (ASTM E84): Flame Spread: 10 Smoke Developed: 15. MONOLAR COATING meets NFPA 90A and 90B 25/50 requirements.ASTM D1475, ASTM D2369, ASTM E96, ASTM F1249, ASTM C755-19, ASTM D93, ASTM E84. ASTM D 1475, ASTM D 2369, ASTM E 96, ASTM F 1249, ASTM C 755 19, ASTM D 93, ASTM E 84. ASTM D-1475, ASTM D-2369, ASTM E-96, ASTM F-1249, ASTM C-755-19, ASTM D-93, ASTM E-84tdsmastics-coating
FosterFoster 60-96 Monolar CoatingAVERAGE WEIGHT / U.S. GALLON (ASTM D1475): 9.5 to 9.9 lbs. (1.14 to 1.19 kg/l) AVERAGE NON-VOLATILE (ASTM D2369): 33% by volume (46% by weight) SERVICE TEMPERATURE LIMITS: Temperature at coated surface. -50°F to 220°F (-46°C to 104°C) WATER VAPOR PERMEANCE (TYPICAL AVERAGE): ASTM E96, PROCEDURE E: 0.025 perms (0.016 metric perms) at 51 mils dry (1.3 mm). ASTM E96, PROCEDURE A: 0.018 perms (0.012 metric perms) at 26 mils dry (0.66 mm). ASTM F1249: 0.05 perms (0.033 metric perms) at 30 mils dry (0.8 mm). Tested at 100°F (38°C) and 90% RH. MONOLAR COATING meets the permeance requirements of ASTM C755-19 for below ambient vapor retarder coatings. WET FLAMMABILITY (ASTM D93): Flash Point: 132°F (56°C) SURFACE BURNING CHARACTERISTICS (ASTM E84): Flame Spread: 10 Smoke Developed: 15. MONOLAR COATING meets NFPA 90A and 90B 25/50 requirements.ASTM D1475, ASTM D2369, ASTM E96, ASTM F1249, ASTM C755-19, ASTM D93, ASTM E84. ASTM D 1475, ASTM D 2369, ASTM E 96, ASTM F 1249, ASTM C 755 19, ASTM D 93, ASTM E 84. ASTM D-1475, ASTM D-2369, ASTM E-96, ASTM F-1249, ASTM C-755-19, ASTM D-93, ASTM E-84.sdsmastics-coating
FosterFoster 65-05 FIRE RESISTIVE C.I. MASTICAVERAGE WEIGHT / U.S. GALLON (ASTM D1475): 9.6 lbs. (1.15 kg/l) AVERAGE NON-VOLATILE (ASTM D2369): 69% by volume (79% by weight) SERVICE TEMPERATURE LIMITS: Temperature at coated surface. -40°F to 200°F (-40°C to 93°C) WATER VAPOR PERMEANCE (TYPICAL AVERAGE): ASTM F1249: 0.03 perms (0.02 metric perms) at 1/8 in. (3.2 mm) dry film thickness. ASTM E96, PROCEDURE A: 0.017 perms (0.011 metric perms) at 115 mils (2.9 mm) dry film thickness. FIRE RESISTIVE C.I. MASTIC meets the permeance requirements of ASTM C755-19 for below ambient vapor retarder coatings. WET FLAMMABILITY (ASTM D93): Flash Point: 106°F (40°C) SURFACE BURNING CHARACTERISTICS (ASTM E84): Flame Spread: 35. ASTM D1475, ASTM D2369, ASTM F1249, ASTM E96, ASTM C755-19, ASTM D93. ASTM D 1475, ASTM D 2369, ASTM F 1249, ASTM E 96, ASTM C 755 19, ASTM D 93. ASTM D-1475, ASTM D-2369, ASTM F-1249, ASTM E-96, ASTM C-755-19, ASTM D-93.tdsmastics-coating
FosterFoster 65-05 FIRE RESISTIVE C.I. MASTICAVERAGE WEIGHT / U.S. GALLON (ASTM D1475): 9.6 lbs. (1.15 kg/l) AVERAGE NON-VOLATILE (ASTM D2369): 69% by volume (79% by weight) SERVICE TEMPERATURE LIMITS: Temperature at coated surface. -40°F to 200°F (-40°C to 93°C) WATER VAPOR PERMEANCE (TYPICAL AVERAGE): ASTM F1249: 0.03 perms (0.02 metric perms) at 1/8 in. (3.2 mm) dry film thickness. ASTM E96, PROCEDURE A: 0.017 perms (0.011 metric perms) at 115 mils (2.9 mm) dry film thickness. FIRE RESISTIVE C.I. MASTIC meets the permeance requirements of ASTM C755-19 for below ambient vapor retarder coatings. WET FLAMMABILITY (ASTM D93): Flash Point: 106°F (40°C) SURFACE BURNING CHARACTERISTICS (ASTM E84): Flame Spread: 35. ASTM D1475, ASTM D2369, ASTM F1249, ASTM E96, ASTM C755-19, ASTM D93. ASTM D 1475, ASTM D 2369, ASTM F 1249, ASTM E 96, ASTM C 755 19, ASTM D 93. ASTM D-1475, ASTM D-2369, ASTM F-1249, ASTM E-96, ASTM C-755-19, ASTM D-93.sdsmastics-coating
FosterFoster 81-10 S.M. ADHESIVEAVERAGE WEIGHT / U.S. GALLON (ASTM D1475): 6.2 lbs. (0.74 kg/l) AVERAGE NON-VOLATILE (ASTM D2369): 17 – 19% by volume (27 – 30% by weight) AVERAGE WEIGHT / U.S. GALLON (ASTM D1475): 6.2 lbs. (0.74 kg/l) AVERAGE NON-VOLATILE (ASTM D2369): 17 – 19% by volume (27 – 30% by weight). S.M. ADHESIVE meets ASTM C916, Type IV (ASC-A-7001- A, Type IV) and NFPA 90A and 90B 25/50 requirements.ASTM D1475, ASTM D2369, ASTM D1475, ASTM D2369, ASTM C916. ASTM D 1475, ASTM D 2369, ASTM D 1475, ASTM D 2369, ASTM C 916. ASTM D-1475, ASTM D-2369, ASTM D-1475, ASTM D-2369, ASTM C-916.tdsmastics-coating
FosterFoster 81-10 S.M. ADHESIVEAVERAGE WEIGHT / U.S. GALLON (ASTM D1475): 6.2 lbs. (0.74 kg/l) AVERAGE NON-VOLATILE (ASTM D2369): 17 – 19% by volume (27 – 30% by weight) AVERAGE WEIGHT / U.S. GALLON (ASTM D1475): 6.2 lbs. (0.74 kg/l) AVERAGE NON-VOLATILE (ASTM D2369): 17 – 19% by volume (27 – 30% by weight). S.M. ADHESIVE meets ASTM C916, Type IV (ASC-A-7001- A, Type IV) and NFPA 90A and 90B 25/50 requirements.ASTM D1475, ASTM D2369, ASTM D1475, ASTM D2369, ASTM C916. ASTM D 1475, ASTM D 2369, ASTM D 1475, ASTM D 2369, ASTM C 916. ASTM D-1475, ASTM D-2369, ASTM D-1475, ASTM D-2369, ASTM C-916.sdsmastics-coating
FosterFoster 81-27 Fibrous AdhesiveAVERAGE WEIGHT/U.S. GALLON (ASTM D 1475): 13.7 lbs. (1.64 kg/l) AVERAGE NON-VOLATILE (ASTM D 2369): 41% by volume (63% by weight) COVERAGE RANGE (FSTM 72): (Subject to type of surface and nature of material being coated) BONDING TIME RANGE (FSTM 66): 0 to 5 minutes SERVICE TEMPERATURE LIMITS (FSTM 70): (Temperature at coated surface) 50°F to 800°F (10°C to 427°C) WET FLAMMABILITY (ASTM D 93): No flash to boiling 212°F (100°C). Nuclear Grade Fibrous Adhesive 81-27Q can be supplied to meet the stress corrosion and chemical analysis requirements of MIL-I-24244C or Nuclear Regulatory Guide 1.36 on special order. Fibrous Adhesive meets requirements for LEED IEQ 4.1 Low-Emitting Materials, Adhesives and Sealants. VOC: 0 g/l, less water and exempt solvents.ASTM D 1475, ASTM D 2369, FSTM 72, FSTM 66, FSTM 70, ASTM D 93, MIL-I-24244C. ASTM D1475, ASTM D2369, FSTM72, FSTM66, FSTM70, ASTM D93, MIL I 24244C. ASTM D-1475, ASTM D-2369, FSTM-72, FSTM-66, FSTM-70, ASTM D-93, MIL-I-24244C.tdsmastics-coating
FosterFoster 81-27 Fibrous AdhesiveAVERAGE WEIGHT/U.S. GALLON (ASTM D 1475): 13.7 lbs. (1.64 kg/l) AVERAGE NON-VOLATILE (ASTM D 2369): 41% by volume (63% by weight) COVERAGE RANGE (FSTM 72): (Subject to type of surface and nature of material being coated) BONDING TIME RANGE (FSTM 66): 0 to 5 minutes SERVICE TEMPERATURE LIMITS (FSTM 70): (Temperature at coated surface) 50°F to 800°F (10°C to 427°C) WET FLAMMABILITY (ASTM D 93): No flash to boiling 212°F (100°C). Nuclear Grade Fibrous Adhesive 81-27Q can be supplied to meet the stress corrosion and chemical analysis requirements of MIL-I-24244C or Nuclear Regulatory Guide 1.36 on special order. Fibrous Adhesive meets requirements for LEED IEQ 4.1 Low-Emitting Materials, Adhesives and Sealants. VOC: 0 g/l, less water and exempt solvents.ASTM D 1475, ASTM D 2369, FSTM 72, FSTM 66, FSTM 70, ASTM D 93, MIL-I-24244C. ASTM D1475, ASTM D2369, FSTM72, FSTM66, FSTM70, ASTM D93, MIL I 24244C. ASTM D-1475, ASTM D-2369, FSTM-72, FSTM-66, FSTM-70, ASTM D-93, MIL-I-24244C.sdsmastics-coating
FosterFoster 81-33 Fire Resistive AdhesiveWEIGHT PER U.S.GALLON: (ASTM D 1475): -13.2 lbs. (1.58 kg/l) APPLICATION NON-VOLATILE (ASTM D 1644): -66% by volume (80% by weight) BONDING TIME RANGE (FSTM 66): -2 to 10 minutes SERVICE TEMPERATURE LIMITS: (Temperature at coated surface) -75°F to 300°F (-59°C to 149°C) WET FLAMMABILITY (ASTM D 3278): -Flash Point 110°F (43°C). Fire Resistive Adhesive meets the requirements of Military Specification MIL-A-3316C, Class 3, Grade A. ASTM D 1475, ASTM D 1644, FSTM 66, ASTM D 3278, MIL-A-3316C. ASTM D1475, ASTM D1644, FSTM66, ASTM D3278, MIL A3316C. ASTM D-1475, ASTM D-1644, FSTM-66, ASTM D-3278, MIL A-3316-C. tdsmastics-coating
FosterFoster 81-33 Fire Resistive AdhesiveWEIGHT PER U.S.GALLON: (ASTM D 1475): -13.2 lbs. (1.58 kg/l) APPLICATION NON-VOLATILE (ASTM D 1644): -66% by volume (80% by weight) BONDING TIME RANGE (FSTM 66): -2 to 10 minutes SERVICE TEMPERATURE LIMITS: (Temperature at coated surface) -75°F to 300°F (-59°C to 149°C) WET FLAMMABILITY (ASTM D 3278): -Flash Point 110°F (43°C). Fire Resistive Adhesive meets the requirements of Military Specification MIL-A-3316C, Class 3, Grade A. ASTM D 1475, ASTM D 1644, FSTM 66, ASTM D 3278, MIL-A-3316C. ASTM D1475, ASTM D1644, FSTM66, ASTM D3278, MIL A3316C. ASTM D-1475, ASTM D-1644, FSTM-66, ASTM D-3278, MIL A-3316-C. sdsmastics-coating
FosterFoster 81-84NHAVERAGE WEIGHT/U.S. GALLON (ASTM D 1475): -Part A – 12.1 Lbs. (1.45 Kg/l) -Part B – 10.3 Lbs. (1.23 Kg/l) -Mixed (A&B) 11.9 Lbs. (1.43 Kg/l) AVERAGE NON-VOLATILE (ASTM D 2369): -97% By Volume (Mixed) -98% By Weight (Mixed) MIXING RATIO: -8 Parts A: 1 Part B (By Volume) -9 Parts A: 1 Part B (By Weight) PACKAGING: 3.4 Gallon (12.8 liter) Kit Containing: • Foster 81-84NH Part A: 3 gallons (11.4 liter) • Foster 81-84 Part B: 0.4 gallons (1.4 liter) POT LIFE (FSTM 91A): 1-2 hours @ 77° F (25°C) SERVICE TEMPERATURE LIMITS: PIR / Polyurthane Foam Insulations As a joint sealant/adhesive -310°F to 200°F (-190°C to 93°C) PIR/Urethane Foam to Metal -260°F to 200°F (-162°C to 93°C) Cellular Glass Insulation As a joint sealant/adhesive -100°F to 200°F (-73°C to 93°C) Cellular Glass to Stainless Steel -155°F to 200°F (-105°C to 93°C). 81-84NH Adhesive/Sealant meets requirements for LEED 2009 IEQ 4.1 Low-Emitting Materials, Adhesives and Sealants. VOC 81-84NH Part A: 20 g/l, less water and exempt solvent. VOC 81-84 Part B: 0 g/l, less water and exempt solvents.ASTM D 1475, ASTM D 2369. ASTM D1475, ASTM D2369. ASTM D-1475, ASTM D-2369. tdsmastics-coating
FosterFoster 81-84NHAVERAGE WEIGHT/U.S. GALLON (ASTM D 1475): -Part A – 12.1 Lbs. (1.45 Kg/l) -Part B – 10.3 Lbs. (1.23 Kg/l) -Mixed (A&B) 11.9 Lbs. (1.43 Kg/l) AVERAGE NON-VOLATILE (ASTM D 2369): -97% By Volume (Mixed) -98% By Weight (Mixed) MIXING RATIO: -8 Parts A: 1 Part B (By Volume) -9 Parts A: 1 Part B (By Weight) PACKAGING: 3.4 Gallon (12.8 liter) Kit Containing: • Foster 81-84NH Part A: 3 gallons (11.4 liter) • Foster 81-84 Part B: 0.4 gallons (1.4 liter) POT LIFE (FSTM 91A): 1-2 hours @ 77° F (25°C) SERVICE TEMPERATURE LIMITS: PIR / Polyurthane Foam Insulations As a joint sealant/adhesive -310°F to 200°F (-190°C to 93°C) PIR/Urethane Foam to Metal -260°F to 200°F (-162°C to 93°C) Cellular Glass Insulation As a joint sealant/adhesive -100°F to 200°F (-73°C to 93°C) Cellular Glass to Stainless Steel -155°F to 200°F (-105°C to 93°C). 81-84NH Adhesive/Sealant meets requirements for LEED 2009 IEQ 4.1 Low-Emitting Materials, Adhesives and Sealants. VOC 81-84NH Part A: 20 g/l, less water and exempt solvent. VOC 81-84 Part B: 0 g/l, less water and exempt solvents.ASTM D 1475, ASTM D 2369. ASTM D1475, ASTM D2369. ASTM D-1475, ASTM D-2369. sdsmastics-coating
FosterFOSTER 82-77 CRYOGENIC ADHESIVEBLENDED AVERAGE WEIGHT / U.S. GALLON (ASTM D1475): Supplied as a 3-part 40 lb. kit. 15.5 lbs./gal. yields 2.6 gallons (1.85 kg/l yields 9.8 liters) BONDING TIME: Dependent on temperature. Air dry: 0 – 1 hour Set through: 4 hours Full cure: 1 week POT LIFE: 1.5 hours at 73°F (23°C) 0.5 hours at 95°F (35°C) SERVICE TEMPERATURE LIMITS: Temperature at coated surface. -320°F to 250°F (-196°C to 121°C) Cellular glass to cellular glass insulation: -320°F to 250°F (-196°C to 121°C) Cellular glass insulation to stainless steel*: -320°F to 250°F (-196°C to 121°C) WET FLAMMABILITY: Greater than 250°F (121°C). CRYOGENIC ADHESIVE meets requirements for LEED IEQ 4.1 Low-Emitting Materials, Adhesives, and Sealants. 82-77 Part A VOC: 0 g/l, less water and exempt solvents. 82-77 Part B VOC: 0 g/l, less water and exempt solvents. ASTM D1475. ASTM D 1475. ASTM D-1475. tdsmastics-coating
FosterFOSTER 82-77 CRYOGENIC ADHESIVEBLENDED AVERAGE WEIGHT / U.S. GALLON (ASTM D1475): Supplied as a 3-part 40 lb. kit. 15.5 lbs./gal. yields 2.6 gallons (1.85 kg/l yields 9.8 liters) BONDING TIME: Dependent on temperature. Air dry: 0 – 1 hour Set through: 4 hours Full cure: 1 week POT LIFE: 1.5 hours at 73°F (23°C) 0.5 hours at 95°F (35°C) SERVICE TEMPERATURE LIMITS: Temperature at coated surface. -320°F to 250°F (-196°C to 121°C) Cellular glass to cellular glass insulation: -320°F to 250°F (-196°C to 121°C) Cellular glass insulation to stainless steel*: -320°F to 250°F (-196°C to 121°C) WET FLAMMABILITY: Greater than 250°F (121°C). CRYOGENIC ADHESIVE meets requirements for LEED IEQ 4.1 Low-Emitting Materials, Adhesives, and Sealants. 82-77 Part A VOC: 0 g/l, less water and exempt solvents. 82-77 Part B VOC: 0 g/l, less water and exempt solvents. ASTM D1475. ASTM D 1475. ASTM D-1475. sdsmastics-coating
FosterFoster 85-20 Spark-Fas AdhesiveAVERAGE WEIGHT / U.S. GALLON (ASTM D1475): 10.8 lbs. (1.29 kg/l) AVERAGE NON-VOLATILE (ASTM D2369): 44% by weight FOR LAP SEALING: 75 sq. ft./gal. (1.8 m2/l) 0.021 in. wet film thickness (0.5 mm). Averages 500 linear feet (152 meters) of 2 in. (5 cm) wide band of adhesive SERVICE TEMPERATURE LIMITS: Temperature at coated surface. -20°F to 180°F (-29°C to 82°C) WET FLAMMABILITY: No flash to boiling: 98°F (37°C) SURFACE BURNING CHARACTERISTICS (ASTM E84): Flame Spread: 15 Smoke Developed: 0. Meets ASTM C916, Type I (ASC-A7001, Type I) requirements, MIL-A-3316C, Class 2, Grade A test requirements, NFPA 90A and 90B 25/50 requirements. VOC Emissions and Content requirements to contribute to LEED v4 EQ Credit: Low Emitting Materials – Paints and Coatings VOC Content: 162 g/l, less water and exempt solvents. ASTM D1475, ASTM D2369, ASTM E84, ASTM C916, MIL-A-3316C. ASTM D 1475, ASTM D 2369, ASTM E 84, ASTM C 916, MIL A 3316C. ASTM D-1475, ASTM D-2369, ASTM E-84, ASTM C-916, MIL-A-3316C. tdsmastics-coating
FosterFoster 85-20 Spark-Fas AdhesiveAVERAGE WEIGHT / U.S. GALLON (ASTM D1475): 10.8 lbs. (1.29 kg/l) AVERAGE NON-VOLATILE (ASTM D2369): 44% by weight FOR LAP SEALING: 75 sq. ft./gal. (1.8 m2/l) 0.021 in. wet film thickness (0.5 mm). Averages 500 linear feet (152 meters) of 2 in. (5 cm) wide band of adhesive SERVICE TEMPERATURE LIMITS: Temperature at coated surface. -20°F to 180°F (-29°C to 82°C) WET FLAMMABILITY: No flash to boiling: 98°F (37°C) SURFACE BURNING CHARACTERISTICS (ASTM E84): Flame Spread: 15 Smoke Developed: 0. Meets ASTM C916, Type I (ASC-A7001, Type I) requirements, MIL-A-3316C, Class 2, Grade A test requirements, NFPA 90A and 90B 25/50 requirements. VOC Emissions and Content requirements to contribute to LEED v4 EQ Credit: Low Emitting Materials – Paints and Coatings VOC Content: 162 g/l, less water and exempt solvents. ASTM D1475, ASTM D2369, ASTM E84, ASTM C916, MIL-A-3316C. ASTM D 1475, ASTM D 2369, ASTM E 84, ASTM C 916, MIL A 3316C. ASTM D-1475, ASTM D-2369, ASTM E-84, ASTM C-916, MIL-A-3316C. sdsmastics-coating
FosterFoster 85-70 SPARK-FAS WB ADHESIVEAVERAGE WEIGHT / U.S. GALLON (ASTM D1475): -8.8 lbs. (1.05 kg/l) AVERAGE NON-VOLATILE (ASTM D2369): -50% by volume (56% by weight) SERVICE TEMPERATURE LIMITS: Temperature at coated surface. -20°F to 200°F (-29°C to 93°C) FLAMMABILITY: -No flash to boiling, over 200°F (93°C) SURFACE BURNING CHARACTERISTICS (ASTM E84): -Flame Spread: 15 -Smoke Developed: 0. SPARK-FAS® WB ADHESIVE meets ASTM C916, Type 1 (ASC-A-7001, Type 1) requirements. SPARK-FAS® WB ADHESIVE meets MIL-A-3316C, Class 2, Grade A requirements, and is listed on the QPL. SPARK-FAS® WB ADHESIVE meets NFPA 90A and 90B 25/50 requirements. VOC Emissions and Content requirements to contribute to LEED v4 EQ Credit: Low Emitting Materials – Paints and Coatings Meets NFPA Standard 90A and 90B 25/50 requirements as a closure mastic VOC Content: 66 g/l, less water and exempt solvents.ASTM D1475, ASTM D2369, ASTM E84, ASTM C916, MIL-A3316C. ASTM D 1475, ASTM D 2369, ASTM E 84, ASTM C 916, MIL A 3316C. ASTM D-1475, ASTM D-2369, ASTM E-84, ASTM C-916, MIL-A-3316C. tdsmastics-coating
FosterFoster 85-70 SPARK-FAS WB ADHESIVEAVERAGE WEIGHT / U.S. GALLON (ASTM D1475): -8.8 lbs. (1.05 kg/l) AVERAGE NON-VOLATILE (ASTM D2369): -50% by volume (56% by weight) SERVICE TEMPERATURE LIMITS: Temperature at coated surface. -20°F to 200°F (-29°C to 93°C) FLAMMABILITY: -No flash to boiling, over 200°F (93°C) SURFACE BURNING CHARACTERISTICS (ASTM E84): -Flame Spread: 15 -Smoke Developed: 0. SPARK-FAS® WB ADHESIVE meets ASTM C916, Type 1 (ASC-A-7001, Type 1) requirements. SPARK-FAS® WB ADHESIVE meets MIL-A-3316C, Class 2, Grade A requirements, and is listed on the QPL. SPARK-FAS® WB ADHESIVE meets NFPA 90A and 90B 25/50 requirements. VOC Emissions and Content requirements to contribute to LEED v4 EQ Credit: Low Emitting Materials – Paints and Coatings Meets NFPA Standard 90A and 90B 25/50 requirements as a closure mastic VOC Content: 66 g/l, less water and exempt solvents.ASTM D1475, ASTM D2369, ASTM E84, ASTM C916, MIL-A3316C. ASTM D 1475, ASTM D 2369, ASTM E 84, ASTM C 916, MIL A 3316C. ASTM D-1475, ASTM D-2369, ASTM E-84, ASTM C-916, MIL-A-3316C. sdsmastics-coating
FosterFoster 85-75 DRION CONTACT CEMENTAVERAGE WEIGHT / U.S. GALLON (ASTM D1475): 11.2 lbs. (1.34 kg/l) AVERAGE NON-VOLATILE (ASTM D2369): 19% by volume (21% by weight) COVERAGE RANGE: 150 to 200 sq. ft./gal. per surface (3.7 – 4.9 m2/l) 0.011 in. to 0.008 in. (0.28 – 0.20 mm) wet film thickness FULL COVERAGE: Applying to both surfaces will yield 75 – 100 sq. ft. bonded surface area per gallon AS A LAP ADHESIVE: 450 – 600 linear ft. (137 – 183 m) of lap per gallon (assuming 2 in. (5 cm) wide band of adhesive at lap) BONDING TIME: 5 min. to 1 hour SERVICE TEMPERATURE LIMITS: Temperature at coated surface. -20°F* to 200°F (-29°C to 93°C) WET FLAMMABILITY: No flash to boiling over 104°F (40°C) SURFACE BURNING CHARACTERISTICS (ASTM E84): Flame Spread: 10 Smoke Developed: 0. DRION CONTACT CEMENT meets NFPA 90A & 90B 25/50 requirements. ASTM D1475, ASTM E84. ASTM D 1475, ASTM E 84. ASTM D-1475, ASTM E-84.tdsmastics-coating
FosterFoster 85-75 DRION CONTACT CEMENTAVERAGE WEIGHT / U.S. GALLON (ASTM D1475): 11.2 lbs. (1.34 kg/l) AVERAGE NON-VOLATILE (ASTM D2369): 19% by volume (21% by weight) COVERAGE RANGE: 150 to 200 sq. ft./gal. per surface (3.7 – 4.9 m2/l) 0.011 in. to 0.008 in. (0.28 – 0.20 mm) wet film thickness FULL COVERAGE: Applying to both surfaces will yield 75 – 100 sq. ft. bonded surface area per gallon AS A LAP ADHESIVE: 450 – 600 linear ft. (137 – 183 m) of lap per gallon (assuming 2 in. (5 cm) wide band of adhesive at lap) BONDING TIME: 5 min. to 1 hour SERVICE TEMPERATURE LIMITS: Temperature at coated surface. -20°F* to 200°F (-29°C to 93°C) WET FLAMMABILITY: No flash to boiling over 104°F (40°C) SURFACE BURNING CHARACTERISTICS (ASTM E84): Flame Spread: 10 Smoke Developed: 0. DRION CONTACT CEMENT meets NFPA 90A & 90B 25/50 requirements. ASTM D1475, ASTM E84. ASTM D 1475, ASTM E 84. ASTM D-1475, ASTM E-84.sdsmastics-coating
FosterFoster 90-07 H.I. MasticAsphalt emulsion. LEED IEQ 4.2. VOC: 21 g/l. WATER VAPOR PERMEANCE (ASTM F 1249): 1.0 perm at 1/8 in. dry film thickness (0.7 metric perm at 3.2 mm) SERVICE TEMPERATURE LIMITS: (Temperature at coated surface) -20°F to 200°F (-29.0°C to 93.3°C). WET FLAMMABILITY (ASTM D 3278): Greater than 200°F (93°C).ASTM F 1249, ASTM D 3278. ASTM F1249, ASTM D3278. ASTM F-1249, ASTM D-3278tdsmastics-coating
FosterFoster 90-07 H.I. MasticAsphalt emulsion. LEED IEQ 4.2. VOC: 21 g/l. WATER VAPOR PERMEANCE (ASTM F 1249): 1.0 perm at 1/8 in. dry film thickness (0.7 metric perm at 3.2 mm) SERVICE TEMPERATURE LIMITS: (Temperature at coated surface) -20°F to 200°F (-29.0°C to 93.3°C). WET FLAMMABILITY (ASTM D 3278): Greater than 200°F (93°C).ASTM F 1249, ASTM D 3278. ASTM F1249, ASTM D3278. ASTM F-1249, ASTM D-3278sdsmastics-coating
FosterFoster 90-61 Cryolar 1K Vapor Stop SealantVapor stop sealant for use in cryogenic applications. Applications including LNG, PUR, PIR, cellular glass. SERVICE TEMPERATURE LIMITS (FSTM 203): (Temperature at coated surface) -320°F to 250°F (-196°C to 121°C) WATER VAPOR PERMEANCE: ASTM F 1249: < 0.01 Perm (<0.0066 Metric Perm) at 0.020-0.025 in. (0.51-0.64 mm) dry film thickness. When tested at 100˚F, 90% RH. SAFETY (ASTM D 93): Flash point 115°F (46°C). DRYING TIME 73°F (23°C) 50% RH (ASTM D 1640): Temperatures below 70°F (21°C) may require longer dry times. AVERAGE WEIGHT/U.S. GALLON (ASTM D 1475): 9.3 lbs. (1.11 kg/l) Average non-Volatile (ASTM D 2369) 45.0% by volume 57.5% by weight COVERAGE RANGE (FSTM 72): (Subject to type of surface being coated).FSTM 203, ASTM F 1249, ASTM D 93, ASTM D 1640, ASTM D 1475, ASTM D 2369, FSTM 72. FSTM 203, ASTM F1249, ASTM D93, ASTM D1640, ASTM D1475, ASTM D2369, FSTM72. FSTM-203, ASTM F-1249, ASTM D-93, ASTM D-1640, ASTM D-1475, ASTM D-2369, FSTM-72.tdsmastics-coating
FosterFoster 90-61 Cryolar 1K Vapor Stop SealantVapor stop sealant for use in cryogenic applications. Applications including LNG, PUR, PIR, cellular glass. SERVICE TEMPERATURE LIMITS (FSTM 203): (Temperature at coated surface) -320°F to 250°F (-196°C to 121°C) WATER VAPOR PERMEANCE: ASTM F 1249: < 0.01 Perm (<0.0066 Metric Perm) at 0.020-0.025 in. (0.51-0.64 mm) dry film thickness. When tested at 100˚F, 90% RH. SAFETY (ASTM D 93): Flash point 115°F (46°C). DRYING TIME 73°F (23°C) 50% RH (ASTM D 1640): Temperatures below 70°F (21°C) may require longer dry times. AVERAGE WEIGHT/U.S. GALLON (ASTM D 1475): 9.3 lbs. (1.11 kg/l) Average non-Volatile (ASTM D 2369) 45.0% by volume 57.5% by weight COVERAGE RANGE (FSTM 72): (Subject to type of surface being coated).FSTM 203, ASTM F 1249, ASTM D 93, ASTM D 1640, ASTM D 1475, ASTM D 2369, FSTM 72. FSTM 203, ASTM F1249, ASTM D93, ASTM D1640, ASTM D1475, ASTM D2369, FSTM72. FSTM-203, ASTM F-1249, ASTM D-93, ASTM D-1640, ASTM D-1475, ASTM D-2369, FSTM-72.sdsmastics-coating
FosterFoster 90-66 Two-Part, Cryogenic, Vapor Stop SealantA two-part, black, elastomeric coating/vapor stop sealant. It is suitable for application to polyurethane foam, polyisocyanurate (PIR) foam, cellular glass, fibrous glass and aerogel insulations. AVERAGE WEIGHT/U.S. GALLON (ASTM D1475): Mixed – 9.6 lbs. (1.15 kg/l) AVERAGE NON-VOLATILE (ASTM D2369): Mixed – 65.0% by volume (73.5% by weight). SERVICE TEMPERATURE LIMITS: Temperature at coated surface. -320°F to 180°F (-196°C to 82°C) Up to 250°F (121°C) intermittent. WATER VAPOR PERMEANCE (TYPICAL AVERAGE): ASTM F1249: 0.01 perms (0.0066 metric perms). WET FLAMMABILITY (ASTM D93): Flash point: 75°F (24°C). ASTM D1475, ASTM D2369, ASTM F1249, ASTM D93. ASTM D 1475, ASTM D 2369, ASTM F 1249, ASTM D 93. ASTM D-1475, ASTM D-2369, ASTM F-1249, ASTM D-93.tdsmastics-coating
FosterFoster 90-66 Two-Part, Cryogenic, Vapor Stop SealantA two-part, black, elastomeric coating/vapor stop sealant. It is suitable for application to polyurethane foam, polyisocyanurate (PIR) foam, cellular glass, fibrous glass and aerogel insulations. AVERAGE WEIGHT/U.S. GALLON (ASTM D1475): Mixed – 9.6 lbs. (1.15 kg/l) AVERAGE NON-VOLATILE (ASTM D2369): Mixed – 65.0% by volume (73.5% by weight). SERVICE TEMPERATURE LIMITS: Temperature at coated surface. -320°F to 180°F (-196°C to 82°C) Up to 250°F (121°C) intermittent. WATER VAPOR PERMEANCE (TYPICAL AVERAGE): ASTM F1249: 0.01 perms (0.0066 metric perms). WET FLAMMABILITY (ASTM D93): Flash point: 75°F (24°C). ASTM D1475, ASTM D2369, ASTM F1249, ASTM D93. ASTM D 1475, ASTM D 2369, ASTM F 1249, ASTM D 93. ASTM D-1475, ASTM D-2369, ASTM F-1249, ASTM D-93.sdsmastics-coating
FosterFoster ElastiSeal 95-88 Butyl Rubber SealantLEED 2009 IEQ 4.1. AAMA 808.3-05 Exterior Perimeter Sealing ASTM C1311 – Solvent Release Sealants in Building Construction, max joint movement of ±7.5% Federal Specifications: TT-S-001657 Type I – Butyl Rubber, Solvent Release Sealing Compound for Buildings and TT-C-1796A – Caulking Compound for Metal and Wood Seam Service Temperature Limits: Temperature at sealant surface. -40°F to 250°F (-40°C to 121°C) Wet Flammability (ASTM D56): Flash Point: 105°F (40°C) Water Vapor Permeance (Typical Average): ASTM F1249: 0.02 perms (0.012 metric perms) at 0.078 in. (2.0 mm) dry film thickness. Tested at 100°F (38°C) and 90% RH 0.04 perms (0.024 metric perms) at 0.078 in. (2.0 mm) dry film thickness. Tested at 73°F (23°C) and 50% RH Surface Burining Characteristics (ASTM E84): Flame Spread: 0 Smoke Developed: 0. VOC content: 250 g/l, less water and exempt solvents.ASTM C-1311, ASTM D-56, ASTM F-1249, ASTM E-84. ASTM C 1311, ASTM D 56, ASTM F 1249, ASTM E 84. ASTM C1311, ASTM D56, ASTM F1249, ASTM E84.tdsmastics-coating
FosterFoster ElastiSeal 95-88 Butyl Rubber SealantLEED 2009 IEQ 4.1. AAMA 808.3-05 Exterior Perimeter Sealing ASTM C1311 – Solvent Release Sealants in Building Construction, max joint movement of ±7.5% Federal Specifications: TT-S-001657 Type I – Butyl Rubber, Solvent Release Sealing Compound for Buildings and TT-C-1796A – Caulking Compound for Metal and Wood Seam Service Temperature Limits: Temperature at sealant surface. -40°F to 250°F (-40°C to 121°C) Wet Flammability (ASTM D56): Flash Point: 105°F (40°C) Water Vapor Permeance (Typical Average): ASTM F1249: 0.02 perms (0.012 metric perms) at 0.078 in. (2.0 mm) dry film thickness. Tested at 100°F (38°C) and 90% RH 0.04 perms (0.024 metric perms) at 0.078 in. (2.0 mm) dry film thickness. Tested at 73°F (23°C) and 50% RH Surface Burining Characteristics (ASTM E84): Flame Spread: 0 Smoke Developed: 0. VOC content: 250 g/l, less water and exempt solvents.ASTM C-1311, ASTM D-56, ASTM F-1249, ASTM E-84. ASTM C 1311, ASTM D 56, ASTM F 1249, ASTM E 84. ASTM C1311, ASTM D56, ASTM F1249, ASTM E84.sdsmastics-coating
FosterFoster Elastolar 95-44C SealantA fire-resistive, flexible, butyl elastomer-based, vapor barrier sealant. AVERAGE WEIGHT/U.S. GALLON (ASTM D1475): 9.3 lbs. (1.12 kg/l) – Pail 9.5 lbs. (1.14 kg/l) – Cartridge AVERAGE NON-VOLATILE (ASTM D2369): 52 to 58% by volume (65% by weight) – Pail 59 to 62% by volume (72% by weight) – Cartridge. WET FLAMMABILITY (ASTM D3278): Flash Point: 105°F (41°C) SURFACE BURNING CHARACTERISTICS (ASTM E84): Flame Spread: 15 Smoke Developed: 0. SERVICE TEMPERATURE LIMITS: Temperature at coated surface. Joint Sealant – Urethane Foam -150°F to 200°F (-101°C to 93°C) Joint Sealant – Cellular Glass -100°F to 250°F (-73°C to 121°C) Flashing Compound and Jacketing Laps (temperature at flashed surface) -67°F to 250°F (-55°C to 121°C). WATER VAPOR PERMEANCE (TYPICAL AVERAGE): ASTM F1249: 0.02 perm (0.013 metric perm) at 0.080 in. (2.0 mm) dry film thickness. LEED 2009 IEQ 4.1. VOC: 384 g/l. ASTM D1475, ASTM D2369, ASTM D3278, ASTM E84, ASTM F1249. ASTM D 1475, ASTM D 2369, ASTM D 3278, ASTM E 84, ASTM F 1249. ASTM D-1475, ASTM D-2369, ASTM D-3278, ASTM E-84, ASTM F-1249tdsmastics-coating
FosterFoster Elastolar 95-44C SealantA fire-resistive, flexible, butyl elastomer-based, vapor barrier sealant. AVERAGE WEIGHT/U.S. GALLON (ASTM D1475): 9.3 lbs. (1.12 kg/l) – Pail 9.5 lbs. (1.14 kg/l) – Cartridge AVERAGE NON-VOLATILE (ASTM D2369): 52 to 58% by volume (65% by weight) – Pail 59 to 62% by volume (72% by weight) – Cartridge. WET FLAMMABILITY (ASTM D3278): Flash Point: 105°F (41°C) SURFACE BURNING CHARACTERISTICS (ASTM E84): Flame Spread: 15 Smoke Developed: 0. SERVICE TEMPERATURE LIMITS: Temperature at coated surface. Joint Sealant – Urethane Foam -150°F to 200°F (-101°C to 93°C) Joint Sealant – Cellular Glass -100°F to 250°F (-73°C to 121°C) Flashing Compound and Jacketing Laps (temperature at flashed surface) -67°F to 250°F (-55°C to 121°C). WATER VAPOR PERMEANCE (TYPICAL AVERAGE): ASTM F1249: 0.02 perm (0.013 metric perm) at 0.080 in. (2.0 mm) dry film thickness. LEED 2009 IEQ 4.1. VOC: 384 g/l. ASTM D1475, ASTM D2369, ASTM D3278, ASTM E84, ASTM F1249. ASTM D 1475, ASTM D 2369, ASTM D 3278, ASTM E 84, ASTM F 1249. ASTM D-1475, ASTM D-2369, ASTM D-3278, ASTM E-84, ASTM F-1249sdsmastics-coating
FosterFoster Flextra 95-50 SealantButyl rubber - vapor barrier sealant in the joints of cellular glass, polyisocyanurate (PIR), urethane and phenolic foam board stock insulations. AVERAGE WEIGHT/U.S. GALLON (ASTM D 1475): 11.6 lbs. (1.39 kg/l) AVERAGE NON-VOLATILE (In use) 82% by volume (89% by weight) 73% by weight (ASTM D 2369, 110oC) COVERAGE RANGE (FSTM 71): Trowel: 12 to 25 sq. ft./gal. (0.29 to 0.61 m2/l) 1/8 in. to 1/16 in. wet film thickness (3.2 mm to 1.6 mm) DRYING TIME: Skins over in 2 to 3 hours, essentially non-drying. SERVICE TEMPERATURE LIMITS (FSTM 202): (Temperature at coated surface) PIR / Urethane Foam -261°F to 200°F (-163°C to 93°C) Cellular Glass -150°F to 200°F (-100°C to 93°C) WATER VAPOR TRANSMISSION RATE (ASTM E 96): The water vapor transmission through 1 in. of impermeable insulation in 12 x 18 in. blocks with 1/8 in. joints of 95-50 is too small to measure. WET FLAMMABILITY (ASTM D 93): Flash point 145°F (63°C). meets requirements for LEED IEQ 4.1. ASTM D-1475, ASTM D-2369, FSTM-71, FSTM 202, ASTM E-96, ASTM D-93. ASTM D1475, ASTM D2369, FSTM71, FSTM202, ASTM E96, ASTM D93. ASTM D 1475, ASTM D 2369, FSTM 71, FSTM 202, ASTM E 96, ASTM D 93. tdsmastics-coating
FosterFoster Flextra 95-50 SealantButyl rubber - vapor barrier sealant in the joints of cellular glass, polyisocyanurate (PIR), urethane and phenolic foam board stock insulations. AVERAGE WEIGHT/U.S. GALLON (ASTM D 1475): 11.6 lbs. (1.39 kg/l) AVERAGE NON-VOLATILE (In use) 82% by volume (89% by weight) 73% by weight (ASTM D 2369, 110oC) COVERAGE RANGE (FSTM 71): Trowel: 12 to 25 sq. ft./gal. (0.29 to 0.61 m2/l) 1/8 in. to 1/16 in. wet film thickness (3.2 mm to 1.6 mm) DRYING TIME: Skins over in 2 to 3 hours, essentially non-drying. SERVICE TEMPERATURE LIMITS (FSTM 202): (Temperature at coated surface) PIR / Urethane Foam -261°F to 200°F (-163°C to 93°C) Cellular Glass -150°F to 200°F (-100°C to 93°C) WATER VAPOR TRANSMISSION RATE (ASTM E 96): The water vapor transmission through 1 in. of impermeable insulation in 12 x 18 in. blocks with 1/8 in. joints of 95-50 is too small to measure. WET FLAMMABILITY (ASTM D 93): Flash point 145°F (63°C). meets requirements for LEED IEQ 4.1. ASTM D-1475, ASTM D-2369, FSTM-71, FSTM 202, ASTM E-96, ASTM D-93. ASTM D1475, ASTM D2369, FSTM71, FSTM202, ASTM E96, ASTM D93. ASTM D 1475, ASTM D 2369, FSTM 71, FSTM 202, ASTM E 96, ASTM D 93. sdsmastics-coating
FosterFoster Foamseal 30-45N SealantAVERAGE WEIGHT / U.S. GALLON (ASTM D1475): 13.5 lbs. (1.62 kg/l) AVERAGE NON-VOLATILE (ASTM D2369): 90% by volume (95% by weight) SERVICE TEMPERATURE LIMITS: Temperature at coated surface. -100ºF to 300ºF (-73ºC to 149ºC) WATER VAPOR PERMEANCE: ASTM F1249: 0.06 perms (0.04 metric perms) tested in 1/8” (3.2 mm) film at 100°F (38°C) and 90% RH WET FLAMMABILITY: 142ºF (61ºC). FOAMSEAL™ 30-45N Sealant meets the requirements of: VOC Emissions and Content requirements to contribute to LEED v4 EQ Credit: Low Emitting Materials – Paints and Coatings. VOC Content: 85 g/l, less water and exempt solvents. ASTM D1475, ASTM D2369, ASTM F1249. ASTM D-1475, ASTM D-2369, ASTM F-1249. ASTM D 1475, ASTM D 2369, ASTM F 1249.tdsmastics-coating
FosterFoster Foamseal 30-45N SealantAVERAGE WEIGHT / U.S. GALLON (ASTM D1475): 13.5 lbs. (1.62 kg/l) AVERAGE NON-VOLATILE (ASTM D2369): 90% by volume (95% by weight) SERVICE TEMPERATURE LIMITS: Temperature at coated surface. -100ºF to 300ºF (-73ºC to 149ºC) WATER VAPOR PERMEANCE: ASTM F1249: 0.06 perms (0.04 metric perms) tested in 1/8” (3.2 mm) film at 100°F (38°C) and 90% RH WET FLAMMABILITY: 142ºF (61ºC). FOAMSEAL™ 30-45N Sealant meets the requirements of: VOC Emissions and Content requirements to contribute to LEED v4 EQ Credit: Low Emitting Materials – Paints and Coatings. VOC Content: 85 g/l, less water and exempt solvents. ASTM D1475, ASTM D2369, ASTM F1249. ASTM D-1475, ASTM D-2369, ASTM F-1249. ASTM D 1475, ASTM D 2369, ASTM F 1249.sdsmastics-coating
FosterFoster Sealfas 30-36 HF CoatingAVERAGE WEIGHT / U.S. GALLON (ASTM D1475): 10.4 lbs. (1.25 kg/l) AVERAGE NON-VOLATILE (ASTM D2369): 39% by volume (51% by weight) SERVICE TEMPERATURE LIMITS: Temperature at coated surface. 0°F to 180°F (-18°C to 82°C) WET FLAMMABILITY: No flash to boiling, 212°F (100°C) WATER VAPOR PERMEANCE (TYPICAL AVERAGE): ASTM F1249: 1.2 perms at 0.0125 in. dry film thickness (0.8metric perms at 0.63 mm). Tested at 24°C and 50% RH. SURFACE BURNING CHARACTERISTICS (ASTM E84): Flame Spread: 0 Smoke Developed: 5 Sealfas 30-36 HF™ Coating meets NFPA 90A and 90B 25/50 requirements. Sealfas 30-36 HF Coating meets the requirements of Military Specification MIL-DTL-3316D Class 1, Grade A and is listed on the QPD. Sealfas 30-36 HF Coating is approved by the U.S. Coast Guard under 164.112/172/0 (SOLAS/IMO approval) superseding 164.012. Meets the requirements of: VOC Emissions and Content requirements to contribute to LEED v4 EQ Credit: Low Emitting Materials – Paints and Coatings. VOC Content: 42 g/l, less water and exempt solvents.ASTM D1475, ASTM D2369, ASTM F1249, ASTM E84, MIL A3316D. ASTM D 1475, ASTM D 2369, ASTM F 1249, ASTM E 84, MIL A 3316 D. ASTM D-1475, ASTM D-2369, ASTM F-1249, ASTM E-84, MIL-A-3316D.tdsmastics-coating
FosterFoster Sealfas 30-36 HF CoatingAVERAGE WEIGHT / U.S. GALLON (ASTM D1475): 10.4 lbs. (1.25 kg/l) AVERAGE NON-VOLATILE (ASTM D2369): 39% by volume (51% by weight) SERVICE TEMPERATURE LIMITS: Temperature at coated surface. 0°F to 180°F (-18°C to 82°C) WET FLAMMABILITY: No flash to boiling, 212°F (100°C) WATER VAPOR PERMEANCE (TYPICAL AVERAGE): ASTM F1249: 1.2 perms at 0.0125 in. dry film thickness (0.8metric perms at 0.63 mm). Tested at 24°C and 50% RH. SURFACE BURNING CHARACTERISTICS (ASTM E84): Flame Spread: 0 Smoke Developed: 5 Sealfas 30-36 HF™ Coating meets NFPA 90A and 90B 25/50 requirements. Sealfas 30-36 HF Coating meets the requirements of Military Specification MIL-DTL-3316D Class 1, Grade A and is listed on the QPD. Sealfas 30-36 HF Coating is approved by the U.S. Coast Guard under 164.112/172/0 (SOLAS/IMO approval) superseding 164.012. Meets the requirements of: VOC Emissions and Content requirements to contribute to LEED v4 EQ Credit: Low Emitting Materials – Paints and Coatings. VOC Content: 42 g/l, less water and exempt solvents.ASTM D1475, ASTM D2369, ASTM F1249, ASTM E84, MIL A3316D. ASTM D 1475, ASTM D 2369, ASTM F 1249, ASTM E 84, MIL A 3316 D. ASTM D-1475, ASTM D-2369, ASTM F-1249, ASTM E-84, MIL-A-3316D.sdsmastics-coating
FosterFoster Weatherite Mastic 46-50ASTM D1475: 11.3 lbs. (1.35 kg/l), ASTM D2369: 52% by volume (64% by weight), ASTM E96, Procedure B: >1 perm at 1/16 inch (1.6 mm) dry film thickness, ASTM E84: Flame Spread: 10 Smoke Developed: 40, Temperature at coated surface. -20ºF to 180ºF (-29ºC to 82ºC)ASTM D1475, ASTM D2369, ASTM E96, ASTM E84, ASTM D 1475, ASTM D 2369, ASTM E 96, ASTM E 84, ASTM D-1475, ASTM D-2369, ASTM E-96, ASTM E-84tdsmastics-coating
FosterFoster Weatherite Mastic 46-50ASTM D1475: 11.3 lbs. (1.35 kg/l), ASTM D2369: 52% by volume (64% by weight), ASTM E96, Procedure B: >1 perm at 1/16 inch (1.6 mm) dry film thickness, ASTM E84: Flame Spread: 10 Smoke Developed: 40, Temperature at coated surface. -20ºF to 180ºF (-29ºC to 82ºC)ASTM D1475, ASTM D2369, ASTM E96, ASTM E84, ASTM D 1475, ASTM D 2369, ASTM E 96, ASTM E 84, ASTM D-1475, ASTM D-2369, ASTM E-96, ASTM E-84sdsmastics-coating
GLTGLT 2025 Fiberglass Lagging ClothWeight (oz./sq.yd.): 18.5 Oz. Sq. Yd. • Thickness: .030” • Thread Count: 20 x 14 • Tensile Warp: 200 • Tensile Fill: 100 • Weave: Plain • Flame Resistance: ASTM D-6413 • Char Length: 1 inch max. • Afterglow: 1 second max. • Flame Out: 1 second max. • MIL-C-20079H, Type 1, Class 9. • MIL-I-24244B and is ANSI/FM 4950 approved. • temperatures up to 1000ºF. • Meets MIL-C- 20079.ASTM D6413, MIL-C20079H, MIL-I24244B, MIL-C20079. ASTM D 6413, MIL-C 20079H, MIL-I 24244B, MIL-C 20079.tdscloths
GLTGLT 2025 Fiberglass Lagging ClothWeight (oz./sq.yd.): 18.5 Oz. Sq. Yd. • Thickness: .030” • Thread Count: 20 x 14 • Tensile Warp: 200 • Tensile Fill: 100 • Weave: Plain • Flame Resistance: ASTM D-6413 • Char Length: 1 inch max. • Afterglow: 1 second max. • Flame Out: 1 second max. • MIL-C-20079H, Type 1, Class 9. • MIL-I-24244B and is ANSI/FM 4950 approved. • temperatures up to 1000ºF. • Meets MIL-C- 20079.ASTM D6413, MIL-C20079H, MIL-I24244B, MIL-C20079. ASTM D 6413, MIL-C 20079H, MIL-I 24244B, MIL-C 20079.sdscloths
GLTGLT 650 Teflon-Impregnated Fiberglass FabricWeight: 17.0 oz./sq. yd. nominal. Thickness: 0.016 in. nominal. Width: 60 in. nominal. Tensile Strength: 410 lb./in. avg. warp, 375 lb./in. avg. fill. Materials: Woven fiberglass and PTFE resins. Color: Gray. Upper Use Temperature: 600°F. Trapezoidal Tear Strength: 20 lbs. avg. warp, 20 lbs. avg. fill. Non-flammability: V-O rating; UL 94, Vertical Burning Test.tdscloths
GLTGLT 650 Teflon-Impregnated Fiberglass FabricWeight: 17.0 oz./sq. yd. nominal. Thickness: 0.016 in. nominal. Width: 60 in. nominal. Tensile Strength: 410 lb./in. avg. warp, 375 lb./in. avg. fill. Materials: Woven fiberglass and PTFE resins. Color: Gray. Upper Use Temperature: 600°F. Trapezoidal Tear Strength: 20 lbs. avg. warp, 20 lbs. avg. fill. Non-flammability: V-O rating; UL 94, Vertical Burning Test.sdscloths
GLTGLT 725 Silicone Fiberglass ClothMIL-I-20079G, MIL-I-224244, Weight: 17.0 oz. yd. ±10%. Base Fabric and Weave: Fiberglass/plain weave. Thickness: 0.015˝ ±10%. Color and Coating: Gray silicone. Tensile Strength Method: FTMS 191A/M5102. Warp: 175 lbs./in. min. avg. Fill: 25 lbs. min. Temperature Resistance: 500°F. Tear Strength Method: FTMS191A/M5136. Warp: 35 lbs. min. avg. Fill: 25 lbs. min. avg. Flame Resistance: Method FTMS 191A/M5903. Flame Out: 1 second. Afterglow: 3.0 seconds.tdscloths
GLTGLT 725 Silicone Fiberglass ClothMIL-I-20079G, MIL-I-224244, Weight: 17.0 oz. yd. ±10%. Base Fabric and Weave: Fiberglass/plain weave. Thickness: 0.015˝ ±10%. Color and Coating: Gray silicone. Tensile Strength Method: FTMS 191A/M5102. Warp: 175 lbs./in. min. avg. Fill: 25 lbs. min. Temperature Resistance: 500°F. Tear Strength Method: FTMS191A/M5136. Warp: 35 lbs. min. avg. Fill: 25 lbs. min. avg. Flame Resistance: Method FTMS 191A/M5903. Flame Out: 1 second. Afterglow: 3.0 seconds.sdscloths
GLTGLT Canvas Insulation JacketGreat Lakes 6 oz. Canvas: Specifications: First Quality Material in Standard 60” wide rolls 100% cotton greige single filled osnaburg Approximately 150 yards per roll Thread Count = 36 x 28 Weight = .51 lbs per linear yard. Great Lakes 8 oz. Canvas: Specifications: First quality material in standard 72” wide rolls 100% cotton greige single filled E-Duck Approximately 125 yards per roll Thread count = 82 x 32 Weight = .85 lbs per linear yard.tdscloths
GLTGLT Canvas Insulation JacketGreat Lakes 6 oz. Canvas: Specifications: First Quality Material in Standard 60” wide rolls 100% cotton greige single filled osnaburg Approximately 150 yards per roll Thread Count = 36 x 28 Weight = .51 lbs per linear yard. Great Lakes 8 oz. Canvas: Specifications: First quality material in standard 72” wide rolls 100% cotton greige single filled E-Duck Approximately 125 yards per roll Thread count = 82 x 32 Weight = .85 lbs per linear yard.sdscloths
GLTGLT Ceramic Fiber BlanketHPS and HTZ ceramic fiber blankets are composed of long, flexible interwoven fibers manufactured by the “spun” process. This yields a strong, lightweight yet durable blanket for applications up to a temperature of 1425°C (2600°F). Both of these blankets have the heat resistance of a hard refractory with greater insulation value, Low thermal conductivity, Very low heat storage with high tensile strength, Provides both thermal shock resistance and sound absorption, Quick repairs. Should lining damage occur, furnace can be cooled quickly, Contains no binder, no fumes or furnace atmosphere contamination, Contains no asbestos, No curing or dry out time. Lining can be fired to operating temperature immediately.sdsceramic-blanket
GLTGLT Ceramic Fiber BlanketHPS and HTZ ceramic fiber blankets are composed of long, flexible interwoven fibers manufactured by the “spun” process. This yields a strong, lightweight yet durable blanket for applications up to a temperature of 1425°C (2600°F). Both of these blankets have the heat resistance of a hard refractory with greater insulation value, Low thermal conductivity, Very low heat storage with high tensile strength, Provides both thermal shock resistance and sound absorption, Quick repairs. Should lining damage occur, furnace can be cooled quickly, Contains no binder, no fumes or furnace atmosphere contamination, Contains no asbestos, No curing or dry out time. Lining can be fired to operating temperature immediately.tdsceramic-blanket
GLTGLT Fiberglass Pipe & Tank WrapASTM C-612-93, ASTM C-795-83, Federal Spec HH-I-558B, Federal Spec HH-B-100BASTM C612, ASTM C93, ASTM C795, ASTM C83, ASTM C 612, ASTM C 93, ASTM C 795, ASTM C 83, ASTM C-612, ASTM C-93, ASTM C-795, ASTM C-83tdspipe-and-tank
GLTGLT Fiberglass Pipe & Tank WrapASTM C-612-93, ASTM C-795-83, Federal Spec HH-I-558B, Federal Spec HH-B-100BASTM C612, ASTM C93, ASTM C795, ASTM C83, ASTM C 612, ASTM C 93, ASTM C 795, ASTM C 83, ASTM C-612, ASTM C-93, ASTM C-795, ASTM C-83sdspipe-and-tank
GLTGLT Mineral Wool Pipe and Tank InsulationTemperature range, ASTM C1393 Up to 1000° F. Water Absorption / Vapor Sorption, ASTM C1104 < 1% by weight. Compressive strength at 10% deformation, ASTM C1393 Complies. Thermal conductivity, 75°F mean temp., ASTM C518, C177 0.27. ASTM C1393, ASTM C1104, ASTM C1393, ASTM C518, C177. ASTM C-1393, ASTM C-1104, ASTM C-1393, ASTM C-518, C-177.ASTM C 1393, ASTM C 1104, ASTM C 1393, ASTM C 518, C 177.tdspipe-and-tank
GLTGLT Mineral Wool Pipe and Tank InsulationTemperature range, ASTM C1393 Up to 1000° F. Water Absorption / Vapor Sorption, ASTM C1104 < 1% by weight. Compressive strength at 10% deformation, ASTM C1393 Complies. Thermal conductivity, 75°F mean temp., ASTM C518, C177 0.27. ASTM C1393, ASTM C1104, ASTM C1393, ASTM C518, C177. ASTM C-1393, ASTM C-1104, ASTM C-1393, ASTM C-518, C-177.ASTM C 1393, ASTM C 1104, ASTM C 1393, ASTM C 518, C 177.sdspipe-and-tank
GLTGLT Temp Mat Removable Insulation BlanketMIL-1-24244, MIL-1-16411, Type II. Service Temperature: Up to 1200°F Fire Resistance: Incombustible Density (Approximate): 9 - 11 lbs./cu. ft.Physical/Mechanical Properties of Glass Fibers Specific Gravity: 2.60 grams/cc. Density: 0.094 lbs./cu. in. Tensile Strength (PSI×10³ @ 70°F): 500 lbs. Modulus of Elasticity (PSI×10 @ 72°F): 10.5 lbs. After Heating (PSI×10 @ 1000°F): 11.8 lbs. Elongation (@ 72°F): 4.8% Thermal Properties of Bulk Glass Softening Point: 1500°F Strain Point: 1100°F Annealing Point:1200°Fsdstemp-mat
GLTGLT Temp Mat Removable Insulation BlanketMIL-1-24244, MIL-1-16411, Type II. Service Temperature: Up to 1200°F Fire Resistance: Incombustible Density (Approximate): 9 - 11 lbs./cu. ft.Physical/Mechanical Properties of Glass Fibers Specific Gravity: 2.60 grams/cc. Density: 0.094 lbs./cu. in. Tensile Strength (PSI×10³ @ 70°F): 500 lbs. Modulus of Elasticity (PSI×10 @ 72°F): 10.5 lbs. After Heating (PSI×10 @ 1000°F): 11.8 lbs. Elongation (@ 72°F): 4.8% Thermal Properties of Bulk Glass Softening Point: 1500°F Strain Point: 1100°F Annealing Point:1200°Ftdstemp-mat
Howred CorporationGOODTEMP Perlite Block InsulationASTM C-610, ASTM C-692, ASTM C-795, ASTM C-871. Moisture Resistant: Low absorption, corrosion guard, construction savings. Fire-Resistant: Does not act as wick, protects against actual fire damage. Superior Inhibition: Provides corrosion inhibition for austenitic stainless steel and other ferrous metals. Low Shrinkage: Less than 1% linear to 1200oF. Corrosion Protection: Acid resistant; contains virtually no chloride, no lime. No Asbestos: No health hazards, meets OSHA requirements High Strength and Flexibility: Easier installation, improved appearance, longer life. Metric Lengths: All one meter lengths. Cost and Time Savings: Full rating without double layers. Easily Identified: Because it's pink, you can easily spot asbestos free GOODTEMP. Retains strength at High Temperatures: Binder does not burn out, material will not flake, or discolor.ASTM C610, ASTM C692, ASTM C795, ASTM C871, ASTM C 610, ASTM C 692, ASTM C 795, ASTM C 871, ASTM C-610, ASTM C-692, ASTM C-795, ASTM C-871tdsblock-insulation
Howred CorporationGOODTEMP Perlite Block InsulationASTM C-610, ASTM C-692, ASTM C-795, ASTM C-871, Moisture Resistant: Low absorption, corrosion guard, construction savings. Fire-Resistant: Does not act as wick, protects against actual fire damage. Superior Inhibition: Provides corrosion inhibition for austenitic stainless steel and other ferrous metals. Low Shrinkage: Less than 1% linear to 1200oF. Corrosion Protection: Acid resistant; contains virtually no chloride, no lime. No Asbestos: No health hazards, meets OSHA requirements High Strength and Flexibility: Easier installation, improved appearance, longer life. Metric Lengths: All one meter lengths. Cost and Time Savings: Full rating without double layers. Easily Identified: Because it's pink, you can easily spot asbestos free GOODTEMP. Retains strength at High Temperatures: Binder does not burn out, material will not flake, or discolor.ASTM C610, ASTM C692, ASTM C795, ASTM C871, ASTM C 610, ASTM C 692, ASTM C 795, ASTM C 871, ASTM C-610, ASTM C-692, ASTM C-795, ASTM C-871sdsblock-insulation
Howred CorporationGOODTEMP Perlite FittingsASTM C-610, ASTM C-692, ASTM C-795, ASTM C-871. Moisture Resistant: Low absorption, corrosion guard, construction savings. Fire-Resistant: Does not act as wick, protects against actual fire damage. Superior Inhibition: Provides corrosion inhibition for austenitic stainless steel and other ferrous metals. Low Shrinkage: Less than 1% linear to 1200oF. Corrosion Protection: Acid resistant; contains virtually no chloride, no lime. No Asbestos: No health hazards, meets OSHA requirements High Strength and Flexibility: Easier installation, improved appearance, longer life. Metric Lengths: All one meter lengths. Cost and Time Savings: Full rating without double layers. Easily Identified: Because it's pink, you can easily spot asbestos free GOODTEMP. Retains strength at High Temperatures: Binder does not burn out, material will not flake, or discolor.ASTM C610, ASTM C692, ASTM C795, ASTM C871, ASTM C 610, ASTM C 692, ASTM C 795, ASTM C 871, ASTM C-610, ASTM C-692, ASTM C-795, ASTM C-871sdsfittings
Howred CorporationGOODTEMP Perlite FittingsASTM C-610, ASTM C-692, ASTM C-795, ASTM C-871. Moisture Resistant: Low absorption, corrosion guard, construction savings. Fire-Resistant: Does not act as wick, protects against actual fire damage. Superior Inhibition: Provides corrosion inhibition for austenitic stainless steel and other ferrous metals. Low Shrinkage: Less than 1% linear to 1200oF. Corrosion Protection: Acid resistant; contains virtually no chloride, no lime. No Asbestos: No health hazards, meets OSHA requirements High Strength and Flexibility: Easier installation, improved appearance, longer life. Metric Lengths: All one meter lengths. Cost and Time Savings: Full rating without double layers. Easily Identified: Because it's pink, you can easily spot asbestos free GOODTEMP. Retains strength at High Temperatures: Binder does not burn out, material will not flake, or discolor.ASTM C610, ASTM C692, ASTM C795, ASTM C871, ASTM C 610, ASTM C 692, ASTM C 795, ASTM C 871, ASTM C-610, ASTM C-692, ASTM C-795, ASTM C-871tdsfittings
Howred CorporationGOODTEMP Perlite Pipe InsulationASTM C-610, ASTM C-692, ASTM C-795, ASTM C-871.Moisture Resistant: Low absorption, corrosion guard, construction savings. Fire-Resistant: Does not act as wick, protects against actual fire damage. Superior Inhibition: Provides corrosion inhibition for austenitic stainless steel and other ferrous metals. Low Shrinkage: Less than 1% linear to 1200oF. Corrosion Protection: Acid resistant; contains virtually no chloride, no lime. No Asbestos: No health hazards, meets OSHA requirements High Strength and Flexibility: Easier installation, improved appearance, longer life. Metric Lengths: All one meter lengths. Cost and Time Savings: Full rating without double layers. Easily Identified: Because it's pink, you can easily spot asbestos free GOODTEMP. Retains strength at High Temperatures: Binder does not burn out, material will not flake, or discolor.ASTM C610, ASTM C692, ASTM C795, ASTM C871, ASTM C 610, ASTM C 692, ASTM C 795, ASTM C 871, ASTM C-610, ASTM C-692, ASTM C-795, ASTM C-871tdspipe-insulation
Howred CorporationGOODTEMP Perlite Pipe InsulationASTM C-610, ASTM C-692, ASTM C-795, ASTM C-871.Moisture Resistant: Low absorption, corrosion guard, construction savings. Fire-Resistant: Does not act as wick, protects against actual fire damage. Superior Inhibition: Provides corrosion inhibition for austenitic stainless steel and other ferrous metals. Low Shrinkage: Less than 1% linear to 1200oF. Corrosion Protection: Acid resistant; contains virtually no chloride, no lime. No Asbestos: No health hazards, meets OSHA requirements High Strength and Flexibility: Easier installation, improved appearance, longer life. Metric Lengths: All one meter lengths. Cost and Time Savings: Full rating without double layers. Easily Identified: Because it's pink, you can easily spot asbestos free GOODTEMP. Retains strength at High Temperatures: Binder does not burn out, material will not flake, or discolor.ASTM C610, ASTM C692, ASTM C795, ASTM C871, ASTM C 610, ASTM C 692, ASTM C 795, ASTM C 871, ASTM C-610, ASTM C-692, ASTM C-795, ASTM C-871sdspipe-insulation
IdealIdeal Products SafetyJacs Cut & Rolled JacketingASTM B 209 Standard Specification for Aluminum and Aluminum-Alloy Sheet and Plate Conforms ASTM C 585 Standard Practice for Inner and Outer Diameters of Thermal Insulation for Nominal Sizes of Pipe Tubing Conforms ASTM C 450 Standard Practice for Fabrication of Thermal Insulating Fitting Covers for NPS Piping, and Vessel Lagging Conforms 45 & 90° Bends Standard Long Radius bends (R = 1.5 x diameter of NPS) Conforms ASTM C1729 5.1.2.3; 5.1.3.3; 10.5.1 Standard Specification for Aluminum Jacketing for Insulation Grade 3. Alloy 1100, Dead Soft Temper Class D, Painted Moisture Barrier Pressed Fittings Conforms ASTM C1729 10.5.2.2 Grade 3; Thickness, 0.024"(0.6mm) Conforms ASTM E84 Flame Spread/Smoke Development 25/50 or less ASTM C1371 Surface Emittance 0.5.ASTM A240, ASTM B209, ASTM C1729, ASTM C1767, ASTM E84, ASTM A240, ASTM B 209, ASTM C 1729, ASTM C 1767, ASTM E 84, ASTM A240, ASTM B-209, ASTM C-1729, ASTM C-1767, ASTM E-84tdsjacketing
IdealIdeal Products SafetyJacs Cut & Rolled JacketingASTM B 209 Standard Specification for Aluminum and Aluminum-Alloy Sheet and Plate Conforms ASTM C 585 Standard Practice for Inner and Outer Diameters of Thermal Insulation for Nominal Sizes of Pipe Tubing Conforms ASTM C 450 Standard Practice for Fabrication of Thermal Insulating Fitting Covers for NPS Piping, and Vessel Lagging Conforms 45 & 90° Bends Standard Long Radius bends (R = 1.5 x diameter of NPS) Conforms ASTM C1729 5.1.2.3; 5.1.3.3; 10.5.1 Standard Specification for Aluminum Jacketing for Insulation Grade 3. Alloy 1100, Dead Soft Temper Class D, Painted Moisture Barrier Pressed Fittings Conforms ASTM C1729 10.5.2.2 Grade 3; Thickness, 0.024"(0.6mm) Conforms ASTM E84 Flame Spread/Smoke Development 25/50 or less ASTM C1371 Surface Emittance 0.5.ASTM A240, ASTM B209, ASTM C1729, ASTM C1767, ASTM E84, ASTM A240, ASTM B 209, ASTM C 1729, ASTM C 1767, ASTM E 84, ASTM A240, ASTM B-209, ASTM C-1729, ASTM C-1767, ASTM E-84sdsjacketing
IdealIdeal Products WeatherJacs Aluminum AA (Aerogel) ElbowsASTM B 209 Standard Specification for Aluminum and Aluminum-Alloy Sheet and Plate Conforms ASTM C 585 Standard Practice for Inner and Outer Diameters of Thermal Insulation for Nominal Sizes of Pipe Tubing Conforms ASTM C 450 Standard Practice for Fabrication of Thermal Insulating Fitting Covers for NPS Piping, and Vessel Lagging Conforms 45 & 90° Bends Standard Long Radius bends (R = 1.5 x diameter of NPS) Conforms ASTM C1729 5.1.2.3; 5.1.3.3; 10.5.1 Standard Specification for Aluminum Jacketing for Insulation Grade 3. Alloy 1100, Dead Soft Temper Class D, Painted Moisture Barrier Pressed Fittings Conforms ASTM C1729 10.5.2.2 Grade 3; Thickness, 0.024"(0.6mm) Conforms ASTM E84 Flame Spread/Smoke Development 25/50 or less ASTM C1371 Surface Emittance 0.5.ASTM B209, ASTM C585, ASTM C450, ASTM C1729, ASTM E84, ASTM C1371, ASTM B 209, ASTM C 585, ASTM C 450, ASTM C 1729, ASTM E 84, ASTM C 1371, ASTM B-209, ASTM C-585, ASTM C-450, ASTM C-1729, ASTM E-84, ASTM C-1371tdsjacketing
IdealIdeal Products WeatherJacs Aluminum AA (Aerogel) ElbowsASTM B 209 Standard Specification for Aluminum and Aluminum-Alloy Sheet and Plate Conforms ASTM C 585 Standard Practice for Inner and Outer Diameters of Thermal Insulation for Nominal Sizes of Pipe Tubing Conforms ASTM C 450 Standard Practice for Fabrication of Thermal Insulating Fitting Covers for NPS Piping, and Vessel Lagging Conforms 45 & 90° Bends Standard Long Radius bends (R = 1.5 x diameter of NPS) Conforms ASTM C1729 5.1.2.3; 5.1.3.3; 10.5.1 Standard Specification for Aluminum Jacketing for Insulation Grade 3. Alloy 1100, Dead Soft Temper Class D, Painted Moisture Barrier Pressed Fittings Conforms ASTM C1729 10.5.2.2 Grade 3; Thickness, 0.024"(0.6mm) Conforms ASTM E84 Flame Spread/Smoke Development 25/50 or less ASTM C1371 Surface Emittance 0.5.ASTM B209, ASTM C585, ASTM C450, ASTM C1729, ASTM E84, ASTM C1371, ASTM B 209, ASTM C 585, ASTM C 450, ASTM C 1729, ASTM E 84, ASTM C 1371, ASTM B-209, ASTM C-585, ASTM C-450, ASTM C-1729, ASTM E-84, ASTM C-1371sdsjacketing
IdealIdeal Products WeatherJacs Aluminum BevelsASTM B 209 Standard Specification for Aluminum and Aluminum-Alloy Sheet and Plate Conforms ASTM C 585 Standard Practice for Inner and Outer Diameters of Thermal Insulation for Nominal Sizes of Pipe Tubing Conforms ASTM C 450 Standard Practice for Fabrication of Thermal Insulating Fitting Covers for NPS Piping, and Vessel Lagging Conforms ASTM C1729 5.1.2.3; 5.1.3.3; 10.5.1 Standard Specification for Aluminum Jacketing for Insulation Grade 3. Alloy 1100, Dead Soft Temper Class D, Painted Moisture Barrier Pressed Fittings Conforms ASTM C1729 10.5.2.2 Grade 3; Thickness, 0.024"(0.6mm) Conforms ASTM E84 Flame Spread/Smoke Development 25/50 or less ASTM C1371 Surface Emittance 0.5.ASTM B209, ASTM C585 ASTM C450, ASTM C1729, ASTM E84, ASTM C1371, ASTM B 209, ASTM C 585 ASTM C 450, ASTM C 1729, ASTM E 84, ASTM C 1371, ASTM B-209, ASTM C-585 ASTM C-450, ASTM C-1729, ASTM E-84, ASTM C-1371tdsfittings
IdealIdeal Products WeatherJacs Aluminum BevelsASTM B 209 Standard Specification for Aluminum and Aluminum-Alloy Sheet and Plate Conforms ASTM C 585 Standard Practice for Inner and Outer Diameters of Thermal Insulation for Nominal Sizes of Pipe Tubing Conforms ASTM C 450 Standard Practice for Fabrication of Thermal Insulating Fitting Covers for NPS Piping, and Vessel Lagging Conforms ASTM C1729 5.1.2.3; 5.1.3.3; 10.5.1 Standard Specification for Aluminum Jacketing for Insulation Grade 3. Alloy 1100, Dead Soft Temper Class D, Painted Moisture Barrier Pressed Fittings Conforms ASTM C1729 10.5.2.2 Grade 3; Thickness, 0.024"(0.6mm) Conforms ASTM E84 Flame Spread/Smoke Development 25/50 or less ASTM C1371 Surface Emittance 0.5.ASTM B209, ASTM C585 ASTM C450, ASTM C1729, ASTM E84, ASTM C1371, ASTM B 209, ASTM C 585 ASTM C 450, ASTM C 1729, ASTM E 84, ASTM C 1371, ASTM B-209, ASTM C-585 ASTM C-450, ASTM C-1729, ASTM E-84, ASTM C-1371sdsfittings
IdealIdeal Products WeatherJacs Aluminum End CapsASTM B 209 Standard Specification for Aluminum and Aluminum-Alloy Sheet and Plate Conforms ASTM C 585 Standard Practice for Inner and Outer Diameters of Thermal Insulation for Nominal Sizes of Pipe Tubing Conforms ASTM C 450 Standard Practice for Fabrication of Thermal Insulating Fitting Covers for NPS Piping, and Vessel Lagging Conforms ASTM C1729 5.1.2.3; 5.1.3.3; 10.5.1 Standard Specification for Aluminum Jacketing for Insulation Grade 3. Alloy 1100, Dead Soft Temper Class D, Painted Moisture Barrier Pressed Fittings Conforms ASTM C1729 10.5.2.2 Grade 3; Thickness, 0.024"(0.6mm) Conforms ASTM E84 Flame Spread/Smoke Development 25/50 or less ASTM C1371 Surface Emittance 0.5.ASTM B209, ASTM C585 ASTM C450, ASTM C1729, ASTM E84, ASTM C1371, ASTM B 209, ASTM C 585 ASTM C 450, ASTM C 1729, ASTM E 84, ASTM C 1371, ASTM B-209, ASTM C-585 ASTM C-450, ASTM C-1729, ASTM E-84, ASTM C-1371tdsfittings
IdealIdeal Products WeatherJacs Aluminum End CapsASTM B 209 Standard Specification for Aluminum and Aluminum-Alloy Sheet and Plate Conforms ASTM C 585 Standard Practice for Inner and Outer Diameters of Thermal Insulation for Nominal Sizes of Pipe Tubing Conforms ASTM C 450 Standard Practice for Fabrication of Thermal Insulating Fitting Covers for NPS Piping, and Vessel Lagging Conforms ASTM C1729 5.1.2.3; 5.1.3.3; 10.5.1 Standard Specification for Aluminum Jacketing for Insulation Grade 3. Alloy 1100, Dead Soft Temper Class D, Painted Moisture Barrier Pressed Fittings Conforms ASTM C1729 10.5.2.2 Grade 3; Thickness, 0.024"(0.6mm) Conforms ASTM E84 Flame Spread/Smoke Development 25/50 or less ASTM C1371 Surface Emittance 0.5.ASTM B209, ASTM C585 ASTM C450, ASTM C1729, ASTM E84, ASTM C1371, ASTM B 209, ASTM C 585 ASTM C 450, ASTM C 1729, ASTM E 84, ASTM C 1371, ASTM B-209, ASTM C-585 ASTM C-450, ASTM C-1729, ASTM E-84, ASTM C-1371sdsfittings
IdealIdeal Products WeatherJacs Aluminum Numbered ElbowsGuaranteed fit. Manufactured to ASTM 1729 for proper fit, even over rigid insulation. Patented WeatherSeal™ System. A better insulating system for your customers. Available in Clear, White, and Grey (other colours available). Available in smooth stainless steel (T304 and T316). No requirement to bead and crimp. Install faster.ASTM 1729, ASTM 1729, ASTM 1729tdsfittings
IdealIdeal Products WeatherJacs Aluminum Numbered ElbowsGuaranteed fit. Manufactured to ASTM 1729 for proper fit, even over rigid insulation. Patented WeatherSeal™ System. A better insulating system for your customers. Available in Clear, White, and Grey (other colours available). Available in smooth stainless steel (T304 and T316). No requirement to bead and crimp. Install faster.ASTM 1729, ASTM 1729, ASTM 1729sdsfittings
IdealIdeal Seal 3000 MasticBacking Thickness: 2 mils (0.05mm), Adhesive Thickness: 15 mils (0.38mm), Total Thickness: 17 mils (0.43mm), Adhesion to Steel: 175 oz/in (48N/25mm), Elongation %: 5, Tensile Strength: 25lb/in (109N/25mm), UL 723 Ratings: Flame spread < 25, Smoke developed < 50tdstapes
IdealIdeal Seal 3000 MasticBacking Thickness: 2 mils (0.05mm), Adhesive Thickness: 15 mils (0.38mm), Total Thickness: 17 mils (0.43mm), Adhesion to Steel: 175 oz/in (48N/25mm), Elongation %: 5, Tensile Strength: 25lb/in (109N/25mm), UL 723 Ratings: Flame spread < 25, Smoke developed < 50sdstapes
IdealIdeal Seal 777 Insulation CladdingTotal Thickness: 8 mils, PSTC-1 Adhesion to Steel: 60 oz/inch, ASTM D882 Tensile Strength: 4400 psi; Total Energy: 230 lbs/in; Elongation at Break: 270%, ASTM D624 Tear Strength: 9 lbs, ASTM E96 Procedure A Water Vapor Transmission: <0.005 US Perms, ASTM D1204 Dimensional Stablility (150˚F - 24 hr: <0.1% dimensional change, ASTM C1263 Thermal Integrity High Temperature (150˚F): No cracking/No delamination, Thermal Integrity Low Temperature (-20˚F): No cracking/No delamination, ASTM C1338 Mold Resistance: No mold growth, UL-723 Fire Ratings: Exceeds 25\50 Flame\Smoke RatingASTM D882, ASTM D624, ASTM E96, ASTM D1204, ASTM C1263, ASTM C1338, ASTM D 882, ASTM D 624, ASTM E 96, ASTM D 1204, ASTM C 1263, ASTM C 1338, ASTM D-882, ASTM D-624, ASTM E-96, ASTM D-1204, ASTM C-1263, ASTM C-1338tdscladding
IdealIdeal Seal 777 Insulation CladdingTotal Thickness: 8 mils, PSTC-1 Adhesion to Steel: 60 oz/inch, ASTM D882 Tensile Strength: 4400 psi; Total Energy: 230 lbs/in; Elongation at Break: 270%, ASTM D624 Tear Strength: 9 lbs, ASTM E96 Procedure A Water Vapor Transmission: <0.005 US Perms, ASTM D1204 Dimensional Stablility (150˚F - 24 hr: <0.1% dimensional change, ASTM C1263 Thermal Integrity High Temperature (150˚F): No cracking/No delamination, Thermal Integrity Low Temperature (-20˚F): No cracking/No delamination, ASTM C1338 Mold Resistance: No mold growth, UL-723 Fire Ratings: Exceeds 25\50 Flame\Smoke RatingASTM D882, ASTM D624, ASTM E96, ASTM D1204, ASTM C1263, ASTM C1338, ASTM D 882, ASTM D 624, ASTM E 96, ASTM D 1204, ASTM C 1263, ASTM C 1338, ASTM D-882, ASTM D-624, ASTM E-96, ASTM D-1204, ASTM C-1263, ASTM C-1338sdscladding
IdealIdeal Seal 777 JacketingProduct Thickness: Aluminum: 7.5 mils (0.19mm) / Embossed Aluminum: 10 mils (.25mm) / white 10.5 mils (.27mm) Micrometer. PSTC-1 Adhesion to Steel: 80 oz/inch (2,234 g/25mm), ASTM C1263 Thermal Integrity Temperature -20˚F to 150˚F (No cracking/No delamination). ASTM D882 Tensile Strength: 4400 psi. ASTM D882 Total Energy: 230 lbs/in. ASTM D882 Elongation at Break: 270%. ASTM D624 Tear Strength: 9 lbs. ASTM E96 Procedure A Water Vapor Transmission: <0.00 US Perms. ASTM D1204 Dimensional Stability (150˚F - 24 hr.): <0.1%. ASTM C1338 Fungi Resistance: No mold growth. ASTM E84 Fire and Smoke Ratings: Exceeds 25/50 Flame/Smoke Rating. ASTM C1371 Emittance 0.03.ASTM C1263, ASTM D882, ASTM D624, ASTM E96, ASTM D1204, ASTM C1338, ASTM E84, ASTM C1371, ASTM C 1263, ASTM D 882, ASTM D 624, ASTM E 96, ASTM D 1204, ASTM C 1338, ASTM E 84, ASTM C 1371, ASTM C-1263, ASTM D-882, ASTM D-624, ASTM E-96, ASTM D-1204, ASTM C-1338, ASTM E-84, ASTM C-1371tdscladding
IdealIdeal Seal 777 JacketingProduct Thickness: Aluminum: 7.5 mils (0.19mm) / Embossed Aluminum: 10 mils (.25mm) / white 10.5 mils (.27mm) Micrometer. PSTC-1 Adhesion to Steel: 80 oz/inch (2,234 g/25mm), ASTM C1263 Thermal Integrity Temperature -20˚F to 150˚F (No cracking/No delamination). ASTM D882 Tensile Strength: 4400 psi. ASTM D882 Total Energy: 230 lbs/in. ASTM D882 Elongation at Break: 270%. ASTM D624 Tear Strength: 9 lbs. ASTM E96 Procedure A Water Vapor Transmission: <0.00 US Perms. ASTM D1204 Dimensional Stability (150˚F - 24 hr.): <0.1%. ASTM C1338 Fungi Resistance: No mold growth. ASTM E84 Fire and Smoke Ratings: Exceeds 25/50 Flame/Smoke Rating. ASTM C1371 Emittance 0.03.ASTM C1263, ASTM D882, ASTM D624, ASTM E96, ASTM D1204, ASTM C1338, ASTM E84, ASTM C1371, ASTM C 1263, ASTM D 882, ASTM D 624, ASTM E 96, ASTM D 1204, ASTM C 1338, ASTM E 84, ASTM C 1371, ASTM C-1263, ASTM D-882, ASTM D-624, ASTM E-96, ASTM D-1204, ASTM C-1338, ASTM E-84, ASTM C-1371sdscladding
IdealIdeal Tape 370 PVC TapeBacking Type PVC, Total Thickness 5 mils (0.13mm), Adhesion to Steel 20 oz/in (14 N/25mm), Tensile Strength15 lb/in (66 N/25mm), Elongation %200, Adhesive System Acrylic, Application Temp. Range-20°F to 250°F -29°C to 104°C, Color Whitetdstapes
IdealIdeal Tape 370 PVC TapeBacking Type PVC, Total Thickness 5 mils (0.13mm), Adhesion to Steel 20 oz/in (14 N/25mm), Tensile Strength15 lb/in (66 N/25mm), Elongation %200, Adhesive System Acrylic, Application Temp. Range-20°F to 250°F -29°C to 104°C, Color Whitesdstapes
IdealIdeal Tape 411 Reinforced StrappingBacking type: BOPP, Thickness: 4.2 mils (0.11 mm), Adhesion to Steel: 50 oz/in (14N/25mm), Elongation %: 4, Tensile Strength: 175 lb/in (766 N/25 mm), Color: Natural.sdstapes
IdealIdeal Tape 411 Reinforced StrappingBacking type: BOPP, Thickness: 4.2 mils (0.11 mm), Adhesion to Steel: 50 oz/in (14N/25mm), Elongation %: 4, Tensile Strength: 175 lb/in (766 N/25 mm), Color: Natural.tdstapes
IdealIdeal Tape 427 PSK TapeDESCRIPTION: WMP/Scrim/Kraft, COLOR: White, ADHESIVE SYSTEM: Rubber, TOTAL THICKNESS mils (mm): 9 (0.23), ADHESION TO STEEL oz./in. (N/25mm): 75 (21), TENSILE STRENGTH lbs./in. (N/25mm): 40 (175), APPROVALS: UL Classifiedtdstapes
IdealIdeal Tape 427 PSK TapeDESCRIPTION: WMP/Scrim/Kraft, COLOR: White, ADHESIVE SYSTEM: Rubber, TOTAL THICKNESS mils (mm): 9 (0.23), ADHESION TO STEEL oz./in. (N/25mm): 75 (21), TENSILE STRENGTH lbs./in. (N/25mm): 40 (175), APPROVALS: UL Classifiedsdstapes
IdealIdeal Tape 469 Duct TapeBacking type: Polyethylene Coated Cloth, Total Thickness: 9 mils (0.23 mm), Adhesion to Steel: 50 oz/in (14N/25mm), Tensile Strength: 20 lb/in (88 N/25 mm), Elongation %: 18, Application Temp. Range: 50°F to 200°F, Color: Silver, Black.tdstapes
IdealIdeal Tape 469 Duct TapeBacking type: Polyethylene Coated Cloth, Total Thickness: 9 mils (0.23 mm), Adhesion to Steel: 50 oz/in (14N/25mm), Tensile Strength: 20 lb/in (88 N/25 mm), Elongation %: 18, Application Temp. Range: 50°F to 200°F, Color: Silver, Black.sdstapes
IdealIdeal Tape 488 Insulation TapeBacking Type: Dead Soft Aluminum Foil, Backing Thickness: 2 mils (0.05 mm), Total Thickness: 3.5 mils (0.09 mm), Adhesion to Steel: 90 oz/in (25N/25 mm), Tensile Strength: 20lb/in (88N/25mm), Elongation %: 3, Operating Temp. Range: -10°F to 180°F -23.3°C to 82.2°C, UL 723 Ratings: Flame spread 5, Smoke developed 10tdstapes
IdealIdeal Tape 488 Insulation TapeBacking Type: Dead Soft Aluminum Foil, Backing Thickness: 2 mils (0.05 mm), Total Thickness: 3.5 mils (0.09 mm), Adhesion to Steel: 90 oz/in (25N/25 mm), Tensile Strength: 20lb/in (88N/25mm), Elongation %: 3, Operating Temp. Range: -10°F to 180°F -23.3°C to 82.2°C, UL 723 Ratings: Flame spread 5, Smoke developed 10sdstapes
IdealIdeal Tape 491 FSK Insulation TapeBacking Type FSK, Total Thickness 6 mils (0.15mm), Adhesion to Steel 100 oz/in (27 N/25mm), Tensile Strength 35 lb/in (153 N/25mm), Elongation % 3, Adhesive System: Rubber, Operating Temp. Range: -10°F to 180°F -23.3°C to 82.2°C, UL-723 Ratings: Flame spread: 10, Smoke Developed 20tdstapes
IdealIdeal Tape 491 FSK Insulation TapeBacking Type FSK, Total Thickness 6 mils (0.15mm), Adhesion to Steel 100 oz/in (27 N/25mm), Tensile Strength 35 lb/in (153 N/25mm), Elongation % 3, Adhesive System: Rubber, Operating Temp. Range: -10°F to 180°F -23.3°C to 82.2°C, UL-723 Ratings: Flame spread: 10, Smoke Developed 20sdstapes
IdealIdeal Tape 888Backing Type: Polyester film, Total Thickness 3.75 mils (0.10mm), Adhesion to Steel 50 oz/in (14 N/25mm), Tensile Strength 18 lb/in (79 N/25mm), Elongation % 5, Adhesive System: Acrylic, Color: Cleartdstapes
IdealIdeal Tape 888Backing Type: Polyester film, Total Thickness 3.75 mils (0.10mm), Adhesion to Steel 50 oz/in (14 N/25mm), Tensile Strength 18 lb/in (79 N/25mm), Elongation % 5, Adhesive System: Acrylic, Color: Clearsdstapes
IdealIdeal Tape Cold Seal 728 ASJ Insulation TapeBacking Type All service Jacket, Total Thickness 9 mils (0.23mm), Adhesion to Steel 100 oz/in (27 N/25mm), Tensile Strength 35 lb/in (153 N/25mm), Elongation % 3, Adhesive System: Cold Seal Acrylic, Minimum Application Temp.: -5°F or -20°C Operating Temp. Range: -35°F to 250°F -37°C to 121°CASTM C1136, ASTM C 1136, ASTM C-1136tdstapes
IdealIdeal Tape Cold Seal 728 ASJ Insulation TapeBacking Type All service Jacket, Total Thickness 9 mils (0.23mm), Adhesion to Steel 100 oz/in (27 N/25mm), Tensile Strength 35 lb/in (153 N/25mm), Elongation % 3, Adhesive System: Cold Seal Acrylic, Minimum Application Temp.: -5°F or -20°C Operating Temp. Range: -35°F to 250°F -37°C to 121°CASTM C1136, ASTM C 1136, ASTM C-1136sdstapes
IdealIdeal Tape Cold Seal 729 ASJ+ Insulation Tape Backing Type: WMP, Total Thickness 10 mils (0.25 mm), Adhesion to Steel 73 oz/in (20 N/25mm), Tensile Strength: 55 lb/in (241 N/25mm), Elongation %: 3, Adhesive System: Cold Seal Acrylic, Minimum Application Temp.: -5°F or -20°C, Application Temp. Range: -35°F to 250°F -37°C to 121°C, UL 723 Ratings: Flame spread 10, Smoke developed 10sdstapes
IdealIdeal Tape Cold Seal 729 ASJ+ Insulation Tape Backing Type: WMP, Total Thickness 10 mils (0.25 mm), Adhesion to Steel 73 oz/in (20 N/25mm), Tensile Strength: 55 lb/in (241 N/25mm), Elongation %: 3, Adhesive System: Cold Seal Acrylic, Minimum Application Temp.: -5°F or -20°C, Application Temp. Range: -35°F to 250°F -37°C to 121°C, UL 723 Ratings: Flame spread 10, Smoke developed 10tdstapes
IdealIdeal Tape Cold Seal 788 Insulation TapeDescription: Dead soft aluminum foil designed for sealing seams, patching and seaming HVAC systems, Color: Aluminum, ADHESIVE SYSTEM: Cold Seal™ Acrylic, TOTAL THICKNESS mils (mm): 3.5 (0.09), ADHESION TO STEEL oz./in. (N/25mm): 90 (25), 90 (25): 20 (88), APPROVALS: UL Classified ULC Classified UL 723 Rated USCG COA Number 164.112/161/0 sdstapes
IdealIdeal Tape Cold Seal 788 Insulation TapeDescription: Dead soft aluminum foil designed for sealing seams, patching and seaming HVAC systems, Color: Aluminum, ADHESIVE SYSTEM: Cold Seal™ Acrylic, TOTAL THICKNESS mils (mm): 3.5 (0.09), ADHESION TO STEEL oz./in. (N/25mm): 90 (25), 90 (25): 20 (88), APPROVALS: UL Classified ULC Classified UL 723 Rated USCG COA Number 164.112/161/0 tdstapes
IdealIdeal Tape Cold Seal 791 FSK Insulation TapeASTM C 1136, Backing Thickness 7.0 mils, Adhesive System Cold Seal Acrylic, Adhesion to Steel ( 70° F) 90.0 (oz./in. width), Adhesion to Steel ( 35° F) 90.0 (oz./in. width), Adhesion to Steel ( 0° F) 90.0 (oz./in. width), Tensile 45.0 (lbs./in. width), Elongation 3.0%, Application Temp. Range 0° F to 180° F, Post Application Temp. Range -35° F to 250° F, UL 723 Ratings Flame Spread 0, Smoke Developed 0ASTM C1136, ASTM C 1136, ASTM C-1136sdstapes
IdealIdeal Tape Cold Seal 791 FSK Insulation TapeASTM C 1136, ASTM C 1136, Backing Thickness 7.0 mils, Adhesive System Cold Seal Acrylic, Adhesion to Steel ( 70° F) 90.0 (oz./in. width), Adhesion to Steel ( 35° F) 90.0 (oz./in. width), Adhesion to Steel ( 0° F) 90.0 (oz./in. width), Tensile 45.0 (lbs./in. width), Elongation 3.0%, Application Temp. Range 0° F to 180° F, Post Application Temp. Range -35° F to 250° F, UL 723 Ratings Flame Spread 0, Smoke Developed 0ASTM C1136, ASTM C 1136, ASTM C-1136tdstapes
IdealIdeal Tape Flex Seal 450UL181B-FX, UL181B-FX Total Thickness: 3 mils (0.08mm), Adhesion to Steel: 40 oz/in (11N/25mm), Elongation %: 140, Tensile Strength: 30lb/in (131N/25mm), Operating Temp. Range: 40°F to 212°F -40°C to 100°C, Colors: Black/Silver, Silver/Blacktdstapes
IdealIdeal Tape Flex Seal 450UL181B-FX Total Thickness: 3 mils (0.08mm), Adhesion to Steel: 40 oz/in (11N/25mm), Elongation %: 140, Tensile Strength: 30lb/in (131N/25mm), Operating Temp. Range: 40°F to 212°F -40°C to 100°C, Colors: Black/Silver, Silver/Blacksdstapes
IdealIdeal Tape Ideal Seal 2000 Foil Insulation TapeUL181B-FX, UL 181A-P, UL181B-FX, UL 181A-P, Total Thickness: 4.3 mil (0.11mm), Adhesion to Steel: Exceeds 60 oz/in (width), Exceeds 16.42 (N/25.4 mm), Tensile: Exceeds 25 (lb/in) width, exceeds 109 (N/25.4 mm), Operating Temp. Range: -20°F to 350°F -29°C to 177°C tdstapes
IdealIdeal Tape Ideal Seal 2000 Foil Insulation TapeUL181B-FX, UL 181A-P, Total Thickness: 4.3 mil (0.11mm), Adhesion to Steel: Exceeds 60 oz/in (width), Exceeds 16.42 (N/25.4 mm), Tensile: Exceeds 25 (lb/in) width, exceeds 109 (N/25.4 mm), Operating Temp. Range: -20°F to 350°F -29°C to 177°C sdstapes
ITW insulation systemsITW ELL-JACS PLUS LINED ALUMINUM ELBOW COVERSEMITTANCE OF ALUMINUM ELBOWS Ell-Jacs™ Plus have an outer surface emittance as measured by ASTM C1371 and specified by ASTM C1729 of: • Bare aluminum (oxidized in service ) = 0.1 FLAMMABILITY Ell-Jacs™ Plus have been tested for flammability via the commonly used ASTM E84 test method. The results are shown below. ASTM E84 Flame Spread Index = 0 ASTM E84 Smoke Developed Index = 5 (Tested with exterior metal surface exposed to the flame) SURFACE FINISHES Due to the pressing process during elbow formation, Ell-Jacs™ Plus have a smooth (mill) finish. COMPLIANCE TO STANDARDS Ell-Jacs™ Plus from ITW Insulation Systems comply with the applicable requirements of ASTM C1729 (Aluminum Jacketing Material Standard), Type I, Grade 3, Class A, which includes the strength and chemical composition requirements for compliance to ASTM B209 (Aluminum Alloy Standard).ASTM C1371, ASTM C1729, ASTM E84, ASTM B209, ASTM C 1371, ASTM C 1729, ASTM E 84, ASTM B 209, ASTM C-1371, ASTM C-1729, ASTM E-84, ASTM B-209tdsfittings
ITW insulation systemsITW ELL-JACS PLUS LINED ALUMINUM ELBOW COVERSEMITTANCE OF ALUMINUM ELBOWS Ell-Jacs™ Plus have an outer surface emittance as measured by ASTM C1371 and specified by ASTM C1729 of: • Bare aluminum (oxidized in service ) = 0.1 FLAMMABILITY Ell-Jacs™ Plus have been tested for flammability via the commonly used ASTM E84 test method. The results are shown below. ASTM E84 Flame Spread Index = 0 ASTM E84 Smoke Developed Index = 5 (Tested with exterior metal surface exposed to the flame) SURFACE FINISHES Due to the pressing process during elbow formation, Ell-Jacs™ Plus have a smooth (mill) finish. COMPLIANCE TO STANDARDS Ell-Jacs™ Plus from ITW Insulation Systems comply with the applicable requirements of ASTM C1729 (Aluminum Jacketing Material Standard), Type I, Grade 3, Class A, which includes the strength and chemical composition requirements for compliance to ASTM B209 (Aluminum Alloy Standard).ASTM C1371, ASTM C1729, ASTM E84, ASTM B209, ASTM C 1371, ASTM C 1729, ASTM E 84, ASTM B 209, ASTM C-1371, ASTM C-1729, ASTM E-84, ASTM B-209sdsfittings
ITW insulation systemsITW Insulation Aluminum Metal JacketingCOMPLIANCE TO STANDARDS All bare and polyfilm lined Aluminum Jacketing from ITW Insulation Systems complies with the requirements of ASTM C1729 (Aluminum Jacketing Material Standard) which includes the strength and chemical composition requirements for compliance to ASTM B209 (Aluminum Alloy Standard). RECOMMENDED THICKNESS ITW recommends that the thickness of aluminum jacketing used vary based on the outer diameter of the insulation system per the requirements of ASTM C1729. This recommended thickness is shown in the table below. EMITTANCE ITW Aluminum Jacketing has an outer surface emittance per ASTM C1371 and specified by ASTM C1729 of: • Bare aluminum (oxidized in service ) = 0.1FLAMMABILITY ITW Aluminum Jacketing with a 3 mil polysurlyn moisture barrier has been tested for flammability using the industry standard ASTM E84 test method. The results were: ASTM E84 Flame Spread Index = 0 ASTM E84 Smoke Developed Index = 5 (Tested with exterior metal surface exposed to the flame)ASTM C1729, ASTM B209, ASTM C1371, ASTM E84, ASTM C 1729, ASTM B 209, ASTM C 1371, ASTM E 84, ASTM C-1729, ASTM B-209, ASTM C-1371, ASTM E-84tdsjacketing
ITW insulation systemsITW Insulation Aluminum Metal JacketingCOMPLIANCE TO STANDARDS All bare and polyfilm lined Aluminum Jacketing from ITW Insulation Systems complies with the requirements of ASTM C1729 (Aluminum Jacketing Material Standard) which includes the strength and chemical composition requirements for compliance to ASTM B209 (Aluminum Alloy Standard). RECOMMENDED THICKNESS ITW recommends that the thickness of aluminum jacketing used vary based on the outer diameter of the insulation system per the requirements of ASTM C1729. This recommended thickness is shown in the table below. EMITTANCE ITW Aluminum Jacketing has an outer surface emittance per ASTM C1371 and specified by ASTM C1729 of: • Bare aluminum (oxidized in service ) = 0.1FLAMMABILITY ITW Aluminum Jacketing with a 3 mil polysurlyn moisture barrier has been tested for flammability using the industry standard ASTM E84 test method. The results were: ASTM E84 Flame Spread Index = 0 ASTM E84 Smoke Developed Index = 5 (Tested with exterior metal surface exposed to the flame)ASTM C1729, ASTM B209, ASTM C1371, ASTM E84, ASTM C 1729, ASTM B 209, ASTM C 1371, ASTM E 84, ASTM C-1729, ASTM B-209, ASTM C-1371, ASTM E-84sdsjacketing
ITW insulation systemsITW Metal Strapping & Seals for Insulation JacketingALUMINUM STRAPPING Aluminum Strapping is manufactured from high quality aluminum alloy conforming to ASTM B-209 designation. Aluminum Wing Seals are manufactured from heavy duty hard temper aluminum conforming to ASTM B-209 designation. These seals are .032" aluminum to allow for maximum tensioning and binding power. They are available in 1/2" and 3/4" widths.ASTM B209, ASTM B 209, ASTM B-209tdsjacketing
ITW insulation systemsITW Metal Strapping & Seals for Insulation JacketingALUMINUM STRAPPING Aluminum Strapping is manufactured from high quality aluminum alloy conforming to ASTM B-209 designation. Aluminum Wing Seals are manufactured from heavy duty hard temper aluminum conforming to ASTM B-209 designation. These seals are .032" aluminum to allow for maximum tensioning and binding power. They are available in 1/2" and 3/4" widths.ASTM B209, ASTM B 209, ASTM B-209sdsjacketing
ITW insulation systemsITW Stainless Steel Roll Insulation JacketingITW's Stainless Steel Roll Jacketing is manufactured from T-304 and T-316 prime grade Stainless Steels. These alloys comply with ASTM A-240, and are supplied with a regular dull finish for reduced glare. The yield strength is 30,000-45,000 PSI and the tensile strength is 75,000-110,000 PSI. These alloys are of a special soft-annealed temper, for ease in fabrication. T-304 is normally used in all except the most corrosive areas, where T-316 is recommended.ASTM A-240, ASTM A-240, ASTM A-240sdsjacketing
ITW insulation systemsITW Stainless Steel Roll Insulation JacketingITW's Stainless Steel Roll Jacketing is manufactured from T-304 and T-316 prime grade Stainless Steels. These alloys comply with ASTM A-240, and are supplied with a regular dull finish for reduced glare. The yield strength is 30,000-45,000 PSI and the tensile strength is 75,000-110,000 PSI. These alloys are of a special soft-annealed temper, for ease in fabrication. T-304 is normally used in all except the most corrosive areas, where T-316 is recommended.ASTM A-240, ASTM A-240, ASTM A-240tdsjacketing
KFlexK-Flex 45 Degree Elbow Rubber FittingsThermal Conductivity - (K) Btu-in/hr-Ft2 -°F (W/mK): 90°F (32°C) Mean Temp = 0.258 (0.0372) 75°F (24°C) Mean Temp = 0.245 (0.0353) 32°F (0°C) Mean Temp = 0.235 (0.0339), ASTM C177. Density: 3-6 lb/ft3, ASTM D1667. Operating Temperature Range: -297°F* (-183°C) to +220°F (104°C), ASTM C534. Water Vapor Permeability (Dry Cup): <0.01 perm-in, ASTM E96. Water Absorption (Volume Change): 0%, ASTM C209. Flame Spread / Smoke Development (up to 2” wall) <25/50, ASTM E84. Flammability: Self-Extinguishing, ASTM D635.Dimensional Stability <7% Linear Shrinkage, ASTM C534. Hot Surface Performance (250°F for 96 hours): No Cracking or Delamination, ASTM C411. Ozone Resistance: Pass, ASTM D1171. Odor Emissions: No Objectionable Odor, ASTM C1304. Chemical/Solvent/Oil/Grease Resistance Good Compatibility Data Available on Request. Flexibility: Excellent, ASTM C534. Pass: Cold Crack Test at -40°F (-40°C), ASTM D1056. Mildew Growth Resistance/Air Erosion: Pass UL 181, ASTM G21. Corrosion Risk pH neutral: 6.6±0.04, DIN 1988. Leachable Chlorides <0.05% water-soluble chloride ions, DIN 1988. UV / Weather Resistance1: Pass, QUV Chamber Test. Sound Transmission Class (1”) 13 ASTM E90. ASTM C534, ASTM D1056, ASTM E84 , ASTM C 534, ASTM D 1056, ASTM E 84 , ASTM C-534, ASTM D-1056, ASTM E-84 tdsfittings
KFlexK-Flex 45 Degree Elbow Rubber FittingsThermal Conductivity - (K) Btu-in/hr-Ft2 -°F (W/mK): 90°F (32°C) Mean Temp = 0.258 (0.0372) 75°F (24°C) Mean Temp = 0.245 (0.0353) 32°F (0°C) Mean Temp = 0.235 (0.0339), ASTM C177. Density: 3-6 lb/ft3, ASTM D1667. Operating Temperature Range: -297°F* (-183°C) to +220°F (104°C), ASTM C534. Water Vapor Permeability (Dry Cup): <0.01 perm-in, ASTM E96. Water Absorption (Volume Change): 0%, ASTM C209. Flame Spread / Smoke Development (up to 2” wall) <25/50, ASTM E84. Flammability: Self-Extinguishing, ASTM D635.Dimensional Stability <7% Linear Shrinkage, ASTM C534. Hot Surface Performance (250°F for 96 hours): No Cracking or Delamination, ASTM C411. Ozone Resistance: Pass, ASTM D1171. Odor Emissions: No Objectionable Odor, ASTM C1304. Chemical/Solvent/Oil/Grease Resistance Good Compatibility Data Available on Request. Flexibility: Excellent, ASTM C534. Pass: Cold Crack Test at -40°F (-40°C), ASTM D1056. Mildew Growth Resistance/Air Erosion: Pass UL 181, ASTM G21. Corrosion Risk pH neutral: 6.6±0.04, DIN 1988. Leachable Chlorides <0.05% water-soluble chloride ions, DIN 1988. UV / Weather Resistance1: Pass, QUV Chamber Test. Sound Transmission Class (1”) 13 ASTM E90. ASTM C534, ASTM D1056, ASTM E84 , ASTM C 534, ASTM D 1056, ASTM E 84 , ASTM C-534, ASTM D-1056, ASTM E-84 sdsfittings
KFlexK-Flex 90 Degree Elbow Rubber FittingThermal Conductivity - (K) Btu-in/hr-Ft2 -°F (W/mK): 90°F (32°C) Mean Temp = 0.258 (0.0372) 75°F (24°C) Mean Temp = 0.245 (0.0353) 32°F (0°C) Mean Temp = 0.235 (0.0339), ASTM C177. Density: 3-6 lb/ft3, ASTM D1667. Operating Temperature Range: -297°F* (-183°C) to +220°F (104°C), ASTM C534. Water Vapor Permeability (Dry Cup): <0.01 perm-in, ASTM E96. Water Absorption (Volume Change): 0%, ASTM C209. Flame Spread / Smoke Development (up to 2” wall) <25/50, ASTM E84. Flammability: Self-Extinguishing, ASTM D635.Dimensional Stability <7% Linear Shrinkage, ASTM C534. Hot Surface Performance (250°F for 96 hours): No Cracking or Delamination, ASTM C411. Ozone Resistance: Pass, ASTM D1171. Odor Emissions: No Objectionable Odor, ASTM C1304. Chemical/Solvent/Oil/Grease Resistance Good Compatibility Data Available on Request. Flexibility: Excellent, ASTM C534. Pass: Cold Crack Test at -40°F (-40°C), ASTM D1056. Mildew Growth Resistance/Air Erosion: Pass UL 181, ASTM G21. Corrosion Risk pH neutral: 6.6±0.04, DIN 1988. Leachable Chlorides <0.05% water-soluble chloride ions, DIN 1988. UV / Weather Resistance1: Pass, QUV Chamber Test. Sound Transmission Class (1”) 13 ASTM E90. ASTM C534, ASTM D1056, ASTM E84 , ASTM C 534, ASTM D 1056, ASTM E 84 , ASTM C-534, ASTM D-1056, ASTM E-84 tdsfittings
KFlexK-Flex 90 Degree Elbow Rubber FittingThermal Conductivity - (K) Btu-in/hr-Ft2 -°F (W/mK): 90°F (32°C) Mean Temp = 0.258 (0.0372) 75°F (24°C) Mean Temp = 0.245 (0.0353) 32°F (0°C) Mean Temp = 0.235 (0.0339), ASTM C177. Density: 3-6 lb/ft3, ASTM D1667. Operating Temperature Range: -297°F* (-183°C) to +220°F (104°C), ASTM C534. Water Vapor Permeability (Dry Cup): <0.01 perm-in, ASTM E96. Water Absorption (Volume Change): 0%, ASTM C209. Flame Spread / Smoke Development (up to 2” wall) <25/50, ASTM E84. Flammability: Self-Extinguishing, ASTM D635.Dimensional Stability <7% Linear Shrinkage, ASTM C534. Hot Surface Performance (250°F for 96 hours): No Cracking or Delamination, ASTM C411. Ozone Resistance: Pass, ASTM D1171. Odor Emissions: No Objectionable Odor, ASTM C1304. Chemical/Solvent/Oil/Grease Resistance Good Compatibility Data Available on Request. Flexibility: Excellent, ASTM C534. Pass: Cold Crack Test at -40°F (-40°C), ASTM D1056. Mildew Growth Resistance/Air Erosion: Pass UL 181, ASTM G21. Corrosion Risk pH neutral: 6.6±0.04, DIN 1988. Leachable Chlorides <0.05% water-soluble chloride ions, DIN 1988. UV / Weather Resistance1: Pass, QUV Chamber Test. Sound Transmission Class (1”) 13 ASTM E90. ASTM C534, ASTM D1056, ASTM E84 , ASTM C 534, ASTM D 1056, ASTM E 84 , ASTM C-534, ASTM D-1056, ASTM E-84 sdsfittings
KFlexK-Flex Insul-Sheet Rubber Sheet InsulationMain Composition: Flame-retarded NBR/PVC-based elastomeric foam Thermal Conductivity (K) Btu-in/hr-Ft2 -°F (W/mK): 90°F (32°C) Mean Temp = 0.258 (0.0372) 75°F (24°C) Mean Temp = 0.245 (0.0353) 32°F (0°C) Mean Temp = 0.235 (0.0339) ASTM C177, Density: 3-6 lb/ft3 ASTM D1667, Operating Temperature Range: -40°F (-40°C) to +200°F (93°C) ASTM C534, Water Vapor Permeability (Dry Cup): <0.01 perm-in, ASTM E96, Water Absorption (Volume Change): 0%, ASTM C209, Flame Spread / Smoke Development (up to 2” wall): <25/50 ASTM E84, Flammability: Self-Extinguishing ASTM D635, Dimensional Stability: <7% Linear Shrinkage ASTM C534, Hot Surface Performance (250°F for 96 hours): No Cracking or Delamination ASTM C411, Ozone Resistance: Pass ASTM D1171, Odor Emissions: No Objectionable Odor ASTM C1304, Chemical/Solvent/Oil/Grease Resistance: Good Compatibility Data Available on Request Flexibility: Excellent ASTM C534, Pass: Cold Crack Test at -40°F (-40°C) ASTM D1056, Mildew Growth Resistance/Air Erosion: Pass UL 181 ASTM G21, Corrosion Risk: pH neutral: 6.6±0.04 DIN 1988 Leachable Chlorides: <0.05% water-soluble chloride ions DIN 1988 UV / Weather Resistance: Good ASTM G90, Sound Transmission Class (1”): 13 ASTM E90.ASTM C177, ASTM D1667, ASTM C534, ASTM E96, ASTM C209, ASTM E84, ASTM D635, ASTM C534, ASTM C411, ASTM D1171, ASTM C1304, ASTM C534, ASTM D1056, ASTM G21, ASTM G90, ASTM E90, ASTM C 177, ASTM D 1667, ASTM C 534, ASTM E 96, ASTM C 209, ASTM E 84, ASTM D 635, ASTM C 534, ASTM C 411, ASTM D 1171, ASTM C 1304, ASTM C 534, ASTM D 1056, ASTM G 21, ASTM G 90, ASTM E 90, ASTM C-177, ASTM D-1667, ASTM C-534, ASTM E-96, ASTM C-209, ASTM E-84, ASTM D-635, ASTM C-534, ASTM C-411, ASTM D-1171, ASTM C-1304, ASTM C-534, ASTM D-1056, ASTM G-21, ASTM G-90, ASTM E-90tdssheet-and-rolls
KFlexK-Flex Insul-Sheet Rubber Sheet InsulationMain Composition: Flame-retarded NBR/PVC-based elastomeric foam Thermal Conductivity (K) Btu-in/hr-Ft2 -°F (W/mK): 90°F (32°C) Mean Temp = 0.258 (0.0372) 75°F (24°C) Mean Temp = 0.245 (0.0353) 32°F (0°C) Mean Temp = 0.235 (0.0339) ASTM C177, Density: 3-6 lb/ft3 ASTM D1667, Operating Temperature Range: -40°F (-40°C) to +200°F (93°C) ASTM C534, Water Vapor Permeability (Dry Cup): <0.01 perm-in, ASTM E96, Water Absorption (Volume Change): 0%, ASTM C209, Flame Spread / Smoke Development (up to 2” wall): <25/50 ASTM E84, Flammability: Self-Extinguishing ASTM D635, Dimensional Stability: <7% Linear Shrinkage ASTM C534, Hot Surface Performance (250°F for 96 hours): No Cracking or Delamination ASTM C411, Ozone Resistance: Pass ASTM D1171, Odor Emissions: No Objectionable Odor ASTM C1304, Chemical/Solvent/Oil/Grease Resistance: Good Compatibility Data Available on Request Flexibility: Excellent ASTM C534, Pass: Cold Crack Test at -40°F (-40°C) ASTM D1056, Mildew Growth Resistance/Air Erosion: Pass UL 181 ASTM G21, Corrosion Risk: pH neutral: 6.6±0.04 DIN 1988 Leachable Chlorides: <0.05% water-soluble chloride ions DIN 1988 UV / Weather Resistance: Good ASTM G90, Sound Transmission Class (1”): 13 ASTM E90.ASTM C177, ASTM D1667, ASTM C534, ASTM E96, ASTM C209, ASTM E84, ASTM D635, ASTM C534, ASTM C411, ASTM D1171, ASTM C1304, ASTM C534, ASTM D1056, ASTM G21, ASTM G90, ASTM E90, ASTM C 177, ASTM D 1667, ASTM C 534, ASTM E 96, ASTM C 209, ASTM E 84, ASTM D 635, ASTM C 534, ASTM C 411, ASTM D 1171, ASTM C 1304, ASTM C 534, ASTM D 1056, ASTM G 21, ASTM G 90, ASTM E 90, ASTM C-177, ASTM D-1667, ASTM C-534, ASTM E-96, ASTM C-209, ASTM E-84, ASTM D-635, ASTM C-534, ASTM C-411, ASTM D-1171, ASTM C-1304, ASTM C-534, ASTM D-1056, ASTM G-21, ASTM G-90, ASTM E-90sdssheet-and-rolls
KFlexK-Flex Insul-Sheet with PSA Rubber Sheet InsulationMain Composition: Thermal Conductivity (K) Btu-in/hr-Ft2 -°F (W/mK): 90°F (32°C) Mean Temp = 0.258 (0.0372) 75°F (24°C) Mean Temp = 0.245 (0.0353) 32°F (0°C) Mean Temp = 0.235 (0.0339) ASTM C177, Density: 3-6 lb/ft3 ASTM D1667, Operating Temperature Range: -40°F (-40°C) to +200°F (93°C) ASTM C534, Water Vapor Permeability (Dry Cup): <0.01 perm-in, ASTM E96, Water Absorption (Volume Change): 0%, ASTM C209, Flame Spread / Smoke Development (up to 2” wall): <25/50 ASTM E84, Dimensional Stability: <7% Linear Shrinkage ASTM C534, Hot Surface Performance (250°F for 96 hours): No Cracking or Delamination ASTM C411, Ozone Resistance: Pass ASTM D1171, Odor Emissions: No Objectionable Odor ASTM C1304, Chemical/Solvent/Oil/Grease Resistance: Good Compatibility Data Available on Request Flexibility: Excellent ASTM C534, Pass: Cold Crack Test at -40°F (-40°C) ASTM D1056, Mildew Growth Resistance/Air Erosion: Pass UL 181 ASTM G21, Corrosion Risk: pH neutral: 6.6±0.04 DIN 1988, Leachable Chlorides: <0.05% water-soluble chloride ions DIN 1988, UV / Weather Resistance: Good ASTM G90, Sound Transmission Class (1”): 13 ASTM E90.ASTM C177, ASTM D1667, ASTM C534, ASTM E96, ASTM C209, ASTM E84, ASTM D635, ASTM C534, ASTM C411, ASTM D1171, ASTM C1304, ASTM C534, ASTM D1056, ASTM G21, ASTM E90, ASTM C 177, ASTM D 1667, ASTM C 534, ASTM E 96, ASTM C 209, ASTM E 84, ASTM D 635, ASTM C 534, ASTM C 411, ASTM D 1171, ASTM C 1304, ASTM C 534, ASTM D 1056, ASTM G 21, ASTM E 90, ASTM C-177, ASTM D-1667, ASTM C-534, ASTM E-96, ASTM C-209, ASTM E-84, ASTM D-635, ASTM C-534, ASTM C-411, ASTM D-1171, ASTM C-1304, ASTM C-534, ASTM D-1056, ASTM G-21, ASTM E-90tdssheet-and-rolls
KFlexK-Flex Insul-Sheet with PSA Rubber Sheet InsulationMain Composition: Thermal Conductivity (K) Btu-in/hr-Ft2 -°F (W/mK): 90°F (32°C) Mean Temp = 0.258 (0.0372) 75°F (24°C) Mean Temp = 0.245 (0.0353) 32°F (0°C) Mean Temp = 0.235 (0.0339) ASTM C177, Density: 3-6 lb/ft3 ASTM D1667, Operating Temperature Range: -40°F (-40°C) to +200°F (93°C) ASTM C534, Water Vapor Permeability (Dry Cup): <0.01 perm-in, ASTM E96, Water Absorption (Volume Change): 0%, ASTM C209, Flame Spread / Smoke Development (up to 2” wall): <25/50 ASTM E84, Dimensional Stability: <7% Linear Shrinkage ASTM C534, Hot Surface Performance (250°F for 96 hours): No Cracking or Delamination ASTM C411, Ozone Resistance: Pass ASTM D1171, Odor Emissions: No Objectionable Odor ASTM C1304, Chemical/Solvent/Oil/Grease Resistance: Good Compatibility Data Available on Request Flexibility: Excellent ASTM C534, Pass: Cold Crack Test at -40°F (-40°C) ASTM D1056, Mildew Growth Resistance/Air Erosion: Pass UL 181 ASTM G21, Corrosion Risk: pH neutral: 6.6±0.04 DIN 1988, Leachable Chlorides: <0.05% water-soluble chloride ions DIN 1988, UV / Weather Resistance: Good ASTM G90, Sound Transmission Class (1”): 13 ASTM E90.ASTM C177, ASTM D1667, ASTM C534, ASTM E96, ASTM C209, ASTM E84, ASTM D635, ASTM C534, ASTM C411, ASTM D1171, ASTM C1304, ASTM C534, ASTM D1056, ASTM G21, ASTM E90, ASTM C 177, ASTM D 1667, ASTM C 534, ASTM E 96, ASTM C 209, ASTM E 84, ASTM D 635, ASTM C 534, ASTM C 411, ASTM D 1171, ASTM C 1304, ASTM C 534, ASTM D 1056, ASTM G 21, ASTM E 90, ASTM C-177, ASTM D-1667, ASTM C-534, ASTM E-96, ASTM C-209, ASTM E-84, ASTM D-635, ASTM C-534, ASTM C-411, ASTM D-1171, ASTM C-1304, ASTM C-534, ASTM D-1056, ASTM G-21, ASTM E-90sdssheet-and-rolls
KFlexK-Flex K-Fit P-trap Rubber FittingsThermal Conductivity (K) 90°F (32°C) Mean Temp = 0.258 (0.0372) ASTM C177. Density 3-6 lb/ft3 ASTM D1667 Operating Temperature Range -297°F* (-183°C) to +220°F (104°C) ASTM C534 Water Vapor Permeability (Dry Cup) <0.01 perm-in ASTM E96 Water Absorption (Volume Change) 0% ASTM C209 Flame Spread / Smoke Development (up to 2” wall) <25/50 ASTM E84 Flammability Self-Extinguishing ASTM D635 Dimensional Stability <7% Linear Shrinkage ASTM C534 Hot Surface Performance (250°F for 96 hours) No Cracking or Delamination ASTM C411 Ozone Resistance Pass ASTM D1171 Odor Emissions No Objectionable Odor ASTM C1304 Chemical/Solvent/Oil/Grease Resistance Good Compatibility Data Available on Request Flexibility Excellent Pass: Cold Crack Test at -40°F (-40°C) ASTM C534 ASTM D1056 Mildew Growth Resistance/Air Erosion Pass UL 181, ASTM G21 Corrosion Risk pH neutral: 6.6±0.04 DIN 1988 Leachable Chlorides <0.05% water-soluble chloride ions DIN 1988 UV / Weather Resistance1 Pass QUV Chamber Test Sound Transmission Class (1”) 13 ASTM E90ASTM C177, ASTM D1667, ASTM E96, ASTM C209, ASTM E84, ASTM D635, ASTM C534, ASTM C411, ASTM D1171, ASTM C1304, ASTM C534 ASTM D1056, ASTM G21, ASTM E90, ASTM C 177, ASTM D 1667, ASTM E 96, ASTM C 209, ASTM E 84, ASTM D 635, ASTM C 534, ASTM C 411, ASTM D 1171, ASTM C 1304, ASTM C 534 ASTM D 1056, ASTM G 21, ASTM E 90, ASTM C-177, ASTM D-1667, ASTM E-96, ASTM C-209, ASTM E-84, ASTM D-635, ASTM C-534, ASTM C-411, ASTM D-1171, ASTM C-1304, ASTM C-534 ASTM D-1056, ASTM G-21, ASTM E-90tdsfittings
KFlexK-Flex K-Fit P-trap Rubber FittingsThermal Conductivity (K) 90°F (32°C) Mean Temp = 0.258 (0.0372) ASTM C177. Density 3-6 lb/ft3 ASTM D1667 Operating Temperature Range -297°F* (-183°C) to +220°F (104°C) ASTM C534 Water Vapor Permeability (Dry Cup) <0.01 perm-in ASTM E96 Water Absorption (Volume Change) 0% ASTM C209 Flame Spread / Smoke Development (up to 2” wall) <25/50 ASTM E84 Flammability Self-Extinguishing ASTM D635 Dimensional Stability <7% Linear Shrinkage ASTM C534 Hot Surface Performance (250°F for 96 hours) No Cracking or Delamination ASTM C411 Ozone Resistance Pass ASTM D1171 Odor Emissions No Objectionable Odor ASTM C1304 Chemical/Solvent/Oil/Grease Resistance Good Compatibility Data Available on Request Flexibility Excellent Pass: Cold Crack Test at -40°F (-40°C) ASTM C534 ASTM D1056 Mildew Growth Resistance/Air Erosion Pass UL 181, ASTM G21 Corrosion Risk pH neutral: 6.6±0.04 DIN 1988 Leachable Chlorides <0.05% water-soluble chloride ions DIN 1988 UV / Weather Resistance1 Pass QUV Chamber Test Sound Transmission Class (1”) 13 ASTM E90ASTM C177, ASTM D1667, ASTM E96, ASTM C209, ASTM E84, ASTM D635, ASTM C534, ASTM C411, ASTM D1171, ASTM C1304, ASTM C534 ASTM D1056, ASTM G21, ASTM E90, ASTM C 177, ASTM D 1667, ASTM E 96, ASTM C 209, ASTM E 84, ASTM D 635, ASTM C 534, ASTM C 411, ASTM D 1171, ASTM C 1304, ASTM C 534 ASTM D 1056, ASTM G 21, ASTM E 90, ASTM C-177, ASTM D-1667, ASTM E-96, ASTM C-209, ASTM E-84, ASTM D-635, ASTM C-534, ASTM C-411, ASTM D-1171, ASTM C-1304, ASTM C-534 ASTM D-1056, ASTM G-21, ASTM E-90ASTM C177, ASTM D1667, ASTM E96, ASTM C209, ASTM E84, ASTM D635, ASTM C534, ASTM C411, ASTM D1171, ASTM C1304, ASTM C534 ASTM D1056, ASTM G21, ASTM E90, ASTM C 177, ASTM D 1667, ASTM E 96, ASTM C 209, ASTM E 84, ASTM D 635, ASTM C 534, ASTM C 411, ASTM D 1171, ASTM C 1304, ASTM C 534 ASTM D 1056, ASTM G 21, ASTM E 90, ASTM C-177, ASTM D-1667, ASTM E-96, ASTM C-209, ASTM E-84, ASTM D-635, ASTM C-534, ASTM C-411, ASTM D-1171, ASTM C-1304, ASTM C-534 ASTM D-1056, ASTM G-21, ASTM E-90sdsfittings
KFlexK-Flex Rubber Duct Liner GrayThermal Conductivity - 90°F (32°C) Mean Temp = 0.27 (0.039), (K) Btu-in/hr-Ft2 -°F (W/mK) - 75°F (24°C) Mean Temp = 0.25 (0.036) 32°F (0°C), ASTM C177. Density: 3-6 lb/ft^3, ASTM D1667. Operating Temperature Range: -297°F* (-183°C) to +220°F (104°C), PSA: -40°F (-40°C) TO +200°F (93°C), ASTM C534. Water Vapor Permeability (Dry Cup): <0.06 perm-in, ASTM E96. Water Absorption (Volume Change): <0,20%, ASTM C209. Flame Spread / Smoke Development (up to 2” wall) <25/50, ASTM E84. ASTM D635.Dimensional Stability <7% Linear Shrinkage, ASTM C534. Hot Surface Performance (220°F for 96 hours): No Cracking or Delamination, ASTM C411. Ozone Resistance: Pass, ASTM D1171. Odor Emissions: No Objectionable Odor, ASTM C1304. Chemical/Solvent/Oil/Grease Resistance Good Compatibility Data Available on Request. Flexibility: Excellent, ASTM C534. Pass: Cold Crack Test at -40°F (-40°C), ASTM D1056. Mildew / Fungi Resistance: Pass UL 181, ASTM G21. Corrosion Risk pH neutral: 6.6±0.04, DIN 1988. Leachable Chlorides <0.05% water-soluble chloride ions, DIN 1988. UV / Weather Resistance1: Pass, QUV Chamber Test. Sound Transmission Class (1”) 12 (Insulation only) ASTM E90. 27 (Insulation adhered to 22-gauge steel duct).ASTM C177, ASTM D1667, ASTM C534, ASTM E96, ASTM C209, ASTM E84, ASTM C534, ASTM C411, ASTM D1171, ASTM C1304, ASTM C534, ASTM D1056, ASTM G21, ASTM C1338, ASTM C1071, ASTM E90, ASTM C 177, ASTM D 1667, ASTM C 534, ASTM E 96, ASTM C 209, ASTM E 84, ASTM C 534, ASTM C 411, ASTM D 1171, ASTM C 1304, ASTM C 534, ASTM D 1056, ASTM G 21, ASTM C 1338, ASTM C 1071, ASTM E 90, ASTM C-177, ASTM D-1667, ASTM C-534, ASTM E-96, ASTM C-209, ASTM E-84, ASTM C-534, ASTM C-411, ASTM D-1171, ASTM C-1304, ASTM C-534, ASTM D-1056, ASTM G-21, ASTM C-1338, ASTM C-1071, ASTM E-90tdsduct-liner
KFlexK-Flex Rubber Duct Liner GrayThermal Conductivity - 90°F (32°C) Mean Temp = 0.27 (0.039), (K) Btu-in/hr-Ft2 -°F (W/mK) - 75°F (24°C) Mean Temp = 0.25 (0.036) 32°F (0°C), ASTM C177. Density: 3-6 lb/ft^3, ASTM D1667. Operating Temperature Range: -297°F* (-183°C) to +220°F (104°C), PSA: -40°F (-40°C) TO +200°F (93°C), ASTM C534. Water Vapor Permeability (Dry Cup): <0.06 perm-in, ASTM E96. Water Absorption (Volume Change): <0,20%, ASTM C209. Flame Spread / Smoke Development (up to 2” wall) <25/50, ASTM E84. ASTM D635.Dimensional Stability <7% Linear Shrinkage, ASTM C534. Hot Surface Performance (220°F for 96 hours): No Cracking or Delamination, ASTM C411. Ozone Resistance: Pass, ASTM D1171. Odor Emissions: No Objectionable Odor, ASTM C1304. Chemical/Solvent/Oil/Grease Resistance Good Compatibility Data Available on Request. Flexibility: Excellent, ASTM C534. Pass: Cold Crack Test at -40°F (-40°C), ASTM D1056. Mildew / Fungi Resistance: Pass UL 181, ASTM G21. Corrosion Risk pH neutral: 6.6±0.04, DIN 1988. Leachable Chlorides <0.05% water-soluble chloride ions, DIN 1988. UV / Weather Resistance1: Pass, QUV Chamber Test. Sound Transmission Class (1”) 12 (Insulation only) ASTM E90. 27 (Insulation adhered to 22-gauge steel duct).ASTM C177, ASTM D1667, ASTM C534, ASTM E96, ASTM C209, ASTM E84, ASTM C534, ASTM C411, ASTM D1171, ASTM C1304, ASTM C534, ASTM D1056, ASTM G21, ASTM C1338, ASTM C1071, ASTM E90, ASTM C 177, ASTM D 1667, ASTM C 534, ASTM E 96, ASTM C 209, ASTM E 84, ASTM C 534, ASTM C 411, ASTM D 1171, ASTM C 1304, ASTM C 534, ASTM D 1056, ASTM G 21, ASTM C 1338, ASTM C 1071, ASTM E 90, ASTM C-177, ASTM D-1667, ASTM C-534, ASTM E-96, ASTM C-209, ASTM E-84, ASTM C-534, ASTM C-411, ASTM D-1171, ASTM C-1304, ASTM C-534, ASTM D-1056, ASTM G-21, ASTM C-1338, ASTM C-1071, ASTM E-90sdsduct-liner
KFlexK-Flex Rubber Duct Liner Gray with PSAThermal Conductivity - 90°F (32°C) Mean Temp = 0.27 (0.039), (K) Btu-in/hr-Ft2 -°F (W/mK) - 75°F (24°C) Mean Temp = 0.25 (0.036) 32°F (0°C), ASTM C177. Density: 3-6 lb/ft^3, ASTM D1667. Operating Temperature Range: -297°F* (-183°C) to +220°F (104°C), PSA: -40°F (-40°C) TO +200°F (93°C), ASTM C534. Water Vapor Permeability (Dry Cup): <0.06 perm-in, ASTM E96. Water Absorption (Volume Change): <0,20%, ASTM C209. Flame Spread / Smoke Development (up to 2” wall) <25/50, ASTM E84. ASTM D635.Dimensional Stability <7% Linear Shrinkage, ASTM C534. Hot Surface Performance (220°F for 96 hours): No Cracking or Delamination, ASTM C411. Ozone Resistance: Pass, ASTM D1171. Odor Emissions: No Objectionable Odor, ASTM C1304. Chemical/Solvent/Oil/Grease Resistance Good Compatibility Data Available on Request. Flexibility: Excellent, ASTM C534. Pass: Cold Crack Test at -40°F (-40°C), ASTM D1056. Mildew / Fungi Resistance: Pass UL 181, ASTM G21. Corrosion Risk pH neutral: 6.6±0.04, DIN 1988. Leachable Chlorides <0.05% water-soluble chloride ions, DIN 1988. UV / Weather Resistance1: Pass, QUV Chamber Test. Sound Transmission Class (1”) 12 (Insulation only) ASTM E90. 27 (Insulation adhered to 22-gauge steel duct).ASTM C177, ASTM D1667, ASTM C534, ASTM E96, ASTM C209, ASTM E84, ASTM C534, ASTM C411, ASTM D1171, ASTM C1304, ASTM C534, ASTM D1056, ASTM G21, ASTM C1338, ASTM C1071, ASTM E90, ASTM C 177, ASTM D 1667, ASTM C 534, ASTM E 96, ASTM C 209, ASTM E 84, ASTM C 534, ASTM C 411, ASTM D 1171, ASTM C 1304, ASTM C 534, ASTM D 1056, ASTM G 21, ASTM C 1338, ASTM C 1071, ASTM E 90, ASTM C-177, ASTM D-1667, ASTM C-534, ASTM E-96, ASTM C-209, ASTM E-84, ASTM C-534, ASTM C-411, ASTM D-1171, ASTM C-1304, ASTM C-534, ASTM D-1056, ASTM G-21, ASTM C-1338, ASTM C-1071, ASTM E-90tdsduct-liner
KFlexK-Flex Rubber Duct Liner Gray with PSAThermal Conductivity - 90°F (32°C) Mean Temp = 0.27 (0.039), (K) Btu-in/hr-Ft2 -°F (W/mK) - 75°F (24°C) Mean Temp = 0.25 (0.036) 32°F (0°C), ASTM C177. Density: 3-6 lb/ft^3, ASTM D1667. Operating Temperature Range: -297°F* (-183°C) to +220°F (104°C), PSA: -40°F (-40°C) TO +200°F (93°C), ASTM C534. Water Vapor Permeability (Dry Cup): <0.06 perm-in, ASTM E96. Water Absorption (Volume Change): <0,20%, ASTM C209. Flame Spread / Smoke Development (up to 2” wall) <25/50, ASTM E84. ASTM D635.Dimensional Stability <7% Linear Shrinkage, ASTM C534. Hot Surface Performance (220°F for 96 hours): No Cracking or Delamination, ASTM C411. Ozone Resistance: Pass, ASTM D1171. Odor Emissions: No Objectionable Odor, ASTM C1304. Chemical/Solvent/Oil/Grease Resistance Good Compatibility Data Available on Request. Flexibility: Excellent, ASTM C534. Pass: Cold Crack Test at -40°F (-40°C), ASTM D1056. Mildew / Fungi Resistance: Pass UL 181, ASTM G21. Corrosion Risk pH neutral: 6.6±0.04, DIN 1988. Leachable Chlorides <0.05% water-soluble chloride ions, DIN 1988. UV / Weather Resistance1: Pass, QUV Chamber Test. Sound Transmission Class (1”) 12 (Insulation only) ASTM E90. 27 (Insulation adhered to 22-gauge steel duct) ASTM C177, ASTM D1667, ASTM C534, ASTM E96, ASTM C209, ASTM E84, ASTM C534, ASTM C411, ASTM D1171, ASTM C1304, ASTM C534, ASTM D1056, ASTM G21, ASTM C1338, ASTM C1071, ASTM E90, ASTM C 177, ASTM D 1667, ASTM C 534, ASTM E 96, ASTM C 209, ASTM E 84, ASTM C 534, ASTM C 411, ASTM D 1171, ASTM C 1304, ASTM C 534, ASTM D 1056, ASTM G 21, ASTM C 1338, ASTM C 1071, ASTM E 90, ASTM C-177, ASTM D-1667, ASTM C-534, ASTM E-96, ASTM C-209, ASTM E-84, ASTM C-534, ASTM C-411, ASTM D-1171, ASTM C-1304, ASTM C-534, ASTM D-1056, ASTM G-21, ASTM C-1338, ASTM C-1071, ASTM E-90sdsduct-liner
KFlexK-Flex Insul-Lock DS Rubber Pipe InsulationThermal Conductivity - (K) Btu-in/hr-Ft2 -°F (W/mK): 90°F (32°C) Mean Temp = 0.258 (0.0372) 75°F (24°C) Mean Temp = 0.245 (0.0353) 32°F (0°C) Mean Temp = 0.235 (0.0339), ASTM C177. Density: 3-6 lb/ft3, ASTM D1667. Operating Temperature Range: -40°F* (-40°C) to +220°F (104°C), ASTM C534. Water Vapor Permeability (Dry Cup): <0.01 perm-in, ASTM E96, Water Vapor Permeability (wet Cup): 0.01 perm-in, ASTM E96. Water Absorption (Volume Change): <0%, ASTM C209. Flame Spread / Smoke Development (up to 2” wall) <25/50, ASTM E84. Flammability: Self-Extinguishing, ASTM D635.Dimensional Stability <7% Linear Shrinkage, ASTM C534. Hot Surface Performance (250°F for 96 hours): No Cracking or Delamination, ASTM C411. Ozone Resistance: Pass, ASTM D1171. Odor Emissions: No Objectionable Odor, ASTM C1304. Chemical/Solvent/Oil/Grease Resistance Good Compatibility Data Available on Request. Flexibility: Excellent, ASTM C534. Pass: Cold Crack Test at -40°F (-40°C), ASTM D1056. Mildew Growth Resistance/Air Erosion: Pass UL 181, ASTM G21. Corrosion Risk pH neutral: 6.6±0.04, DIN 1988. Leachable Chlorides <0.05% water-soluble chloride ions, DIN 1988. UV / Weather Resistance1: Pass, QUV Chamber Test. Sound Transmission Class (1”) 13 ASTM E90. ASTM C534 Type 1, Grade 1 ` ASTM D1056-00-2B1 ` New York City MEA 186-86-M Vol. V ` USDA Compliant ` CFIA Compliant ` RoHS Compliant ` UL 94-5V Flammability Classification (#E300774) ` ASTM E84 25/50-rated (to 2”) - tested to UL 723, NFPA 255 and CAN/ULC S102-03 ` NFPA No. 101 Class A Rating ` NFPA 90A, 90B ` Meets requirements of California ECB Title 24 ` UL GREENGUARD® Gold Certified ` Meets energy code requirements of ASHRAE 90.1 and 189.1.ASTM C177, ASTM D1667, ASTM C534, ASTM E96, ASTM C209, ASTM E84, ASTM D635, ASTM C534, ASTM C411, ASTM D1171, ASTM C1304, ASTM C534, ASTM D1056, ASTM G21, ASTM G90, ASTM E90, ASTM C 177, ASTM D 1667, ASTM C 534, ASTM E 96, ASTM C 209, ASTM E 84, ASTM D 635, ASTM C 534, ASTM C 411, ASTM D 1171, ASTM C 1304, ASTM C 534, ASTM D 1056, ASTM G 21, ASTM G 90, ASTM E 90, ASTM C-177, ASTM D-1667, ASTM C-534, ASTM E-96, ASTM C-209, ASTM E-84, ASTM D-635, ASTM C-534, ASTM C-411, ASTM D-1171, ASTM C-1304, ASTM C-534, ASTM D-1056, ASTM G-21, ASTM G-90, ASTM E-90tdspipe-insulation
KFlexK-Flex Insul-Lock DS Rubber Pipe InsulationThermal Conductivity - (K) Btu-in/hr-Ft2 -°F (W/mK): 90°F (32°C) Mean Temp = 0.258 (0.0372) 75°F (24°C) Mean Temp = 0.245 (0.0353) 32°F (0°C) Mean Temp = 0.235 (0.0339), ASTM C177. Density: 3-6 lb/ft3, ASTM D1667. Operating Temperature Range: -40°F* (-40°C) to +220°F (104°C), ASTM C534. Water Vapor Permeability (Dry Cup): <0.01 perm-in, ASTM E96, Water Vapor Permeability (wet Cup): 0.01 perm-in, ASTM E96. Water Absorption (Volume Change): <0%, ASTM C209. Flame Spread / Smoke Development (up to 2” wall) <25/50, ASTM E84. Flammability: Self-Extinguishing, ASTM D635.Dimensional Stability <7% Linear Shrinkage, ASTM C534. Hot Surface Performance (250°F for 96 hours): No Cracking or Delamination, ASTM C411. Ozone Resistance: Pass, ASTM D1171. Odor Emissions: No Objectionable Odor, ASTM C1304. Chemical/Solvent/Oil/Grease Resistance Good Compatibility Data Available on Request. Flexibility: Excellent, ASTM C534. Pass: Cold Crack Test at -40°F (-40°C), ASTM D1056. Mildew Growth Resistance/Air Erosion: Pass UL 181, ASTM G21. Corrosion Risk pH neutral: 6.6±0.04, DIN 1988. Leachable Chlorides <0.05% water-soluble chloride ions, DIN 1988. UV / Weather Resistance1: Pass, QUV Chamber Test. Sound Transmission Class (1”) 13 ASTM E90. ASTM C534 Type 1, Grade 1 ` ASTM D1056-00-2B1 ` New York City MEA 186-86-M Vol. V ` USDA Compliant ` CFIA Compliant ` RoHS Compliant ` UL 94-5V Flammability Classification (#E300774) ` ASTM E84 25/50-rated (to 2”) - tested to UL 723, NFPA 255 and CAN/ULC S102-03 ` NFPA No. 101 Class A Rating ` NFPA 90A, 90B ` Meets requirements of California ECB Title 24 ` UL GREENGUARD® Gold Certified ` Meets energy code requirements of ASHRAE 90.1 and 189.1.ASTM C177, ASTM D1667, ASTM C534, ASTM E96, ASTM C209, ASTM E84, ASTM D635, ASTM C534, ASTM C411, ASTM D1171, ASTM C1304, ASTM C534, ASTM D1056, ASTM G21, ASTM G90, ASTM E90, ASTM C 177, ASTM D 1667, ASTM C 534, ASTM E 96, ASTM C 209, ASTM E 84, ASTM D 635, ASTM C 534, ASTM C 411, ASTM D 1171, ASTM C 1304, ASTM C 534, ASTM D 1056, ASTM G 21, ASTM G 90, ASTM E 90, ASTM C-177, ASTM D-1667, ASTM C-534, ASTM E-96, ASTM C-209, ASTM E-84, ASTM D-635, ASTM C-534, ASTM C-411, ASTM D-1171, ASTM C-1304, ASTM C-534, ASTM D-1056, ASTM G-21, ASTM G-90, ASTM E-90sdspipe-insulation
KFlexK-Flex Insul-Tube Rubber Pipe InsulationThermal Conductivity (K) 90°F (32°C) Mean Temp 0.258 (0.0372) ASTM C 177, Density 3-6 lb/ft3 ASTM D 1667 Operating Temperature Range -297°F* (-183°C) to +220°F (+104°C)** ASTM C534 Water Vapor Permeability (Dry Cup) <0.01 perm-in ASTM E96 Water Absorption (Volume Change) 0% ASTM C209 Flame Spread / Smoke Development (up to 2” wall) <25/50 ASTM E84 Dimensional Stability <7% Linear Shrinkage ASTM C534 Hot Surface Performance (250°F for 96 hours) No Cracking or Delamination ASTM C411 Ozone Resistance Pass ASTM D1171 Odor Emissions No Objectionable Odor ASTM C1304 Chemical/Solvent/Oil/Grease Resistance Good Compatibility Data Available on Request Flexibility Excellent Pass: Cold Crack Test at -40°F (-40°C) ASTM C534 ASTM D1056 Mildew Growth Resistance/Air Erosion Pass UL 181, ASTM G21 Corrosion Risk pH neutral: 6.6±0.04 DIN 1988 Leachable Chlorides <0.05% water-soluble chloride ions DIN 1988 UV / Weather Resistance1 Pass QUV Chamber Test Sound Transmission Class (1”) 13 ASTM E90. MIL-P-15280, Form T.ASTM C177, ASTM D1667, ASTM C534, ASTM E96, ASTM C209, ASTM E84, ASTM D635, ASTM C534, ASTM C411, ASTM D1171, ASTM C1304, ASTM C534, ASTM D1056, ASTM G21, ASTM E90, ASTM C 177, ASTM D 1667, ASTM C 534, ASTM E 96, ASTM C 209, ASTM E 84, ASTM D 635, ASTM C 534, ASTM C 411, ASTM D 1171, ASTM C 1304, ASTM C 534, ASTM D 1056, ASTM G 21, ASTM E 90, ASTM C-177, ASTM D-1667, ASTM C-534, ASTM E-96, ASTM C-209, ASTM E-84, ASTM D-635, ASTM C-534, ASTM C-411, ASTM D-1171, ASTM C-1304, ASTM C-534, ASTM D-1056, ASTM G-21, ASTM E-90tdspipe-insulation
KFlexK-Flex Insul-Tube Rubber Pipe InsulationThermal Conductivity (K) 90°F (32°C) Mean Temp 0.258 (0.0372) ASTM C 177, Density 3-6 lb/ft3 ASTM D 1667 Operating Temperature Range -297°F* (-183°C) to +220°F (+104°C)** ASTM C534 Water Vapor Permeability (Dry Cup) <0.01 perm-in ASTM E96 Water Absorption (Volume Change) 0% ASTM C209 Flame Spread / Smoke Development (up to 2” wall) <25/50 ASTM E84 Dimensional Stability <7% Linear Shrinkage ASTM C534 Hot Surface Performance (250°F for 96 hours) No Cracking or Delamination ASTM C411 Ozone Resistance Pass ASTM D1171 Odor Emissions No Objectionable Odor ASTM C1304 Chemical/Solvent/Oil/Grease Resistance Good Compatibility Data Available on Request Flexibility Excellent Pass: Cold Crack Test at -40°F (-40°C) ASTM C534 ASTM D1056 Mildew Growth Resistance/Air Erosion Pass UL 181, ASTM G21 Corrosion Risk pH neutral: 6.6±0.04 DIN 1988 Leachable Chlorides <0.05% water-soluble chloride ions DIN 1988 UV / Weather Resistance1 Pass QUV Chamber Test Sound Transmission Class (1”) 13 ASTM E90. MIL-P-15280, Form T.ASTM C177, ASTM D1667, ASTM C534, ASTM E96, ASTM C209, ASTM E84, ASTM D635, ASTM C534, ASTM C411, ASTM D1171, ASTM C1304, ASTM C534, ASTM D1056, ASTM G21, ASTM E90, ASTM C 177, ASTM D 1667, ASTM C 534, ASTM E 96, ASTM C 209, ASTM E 84, ASTM D 635, ASTM C 534, ASTM C 411, ASTM D 1171, ASTM C 1304, ASTM C 534, ASTM D 1056, ASTM G 21, ASTM E 90, ASTM C-177, ASTM D-1667, ASTM C-534, ASTM E-96, ASTM C-209, ASTM E-84, ASTM D-635, ASTM C-534, ASTM C-411, ASTM D-1171, ASTM C-1304, ASTM C-534, ASTM D-1056, ASTM G-21, ASTM E-90sdspipe-insulation
KFlexK-Flex Rubber Seam TapeMain Composition Flexible PVC strip, acrylic adhesive and polyethylene teraphthalate (PET) release liner Color Black or White Thickness .005” ± .0004” Surface Mass 137 g/m2 High Temperature Usage (insulation surface and ambient) +165°F Installation Temperature +50°F to +85°F Storage Recommendations 1 year between +50°F and +85°F Flammability 25/50-rated ASTM E84 Adhesive Type Acrylic Standard Length 50m (164’) Standard Width 2”ASTM E84, ASTM E 84, ASTM E-84sdstapes
KFlexK-Flex Rubber Seam TapeMain Composition Flexible PVC strip, acrylic adhesive and polyethylene teraphthalate (PET) release liner Color Black or White Thickness .005” ± .0004” Surface Mass 137 g/m2 High Temperature Usage (insulation surface and ambient) +165°F Installation Temperature +50°F to +85°F Storage Recommendations 1 year between +50°F and +85°F Flammability 25/50-rated ASTM E84 Adhesive Type Acrylic Standard Length 50m (164’) Standard Width 2”ASTM E84, ASTM E 84, ASTM E-84tdstapes
KFlexK-Flex K-Fit Rubber FittingsThermal Conductivity (K) 90°F (32°C) Mean Temp = 0.258 (0.0372) ASTM C177. Density 3-6 lb/ft3 ASTM D1667 Operating Temperature Range -297°F* (-183°C) to +220°F (104°C) ASTM C534 Water Vapor Permeability (Dry Cup) <0.01 perm-in ASTM E96 Water Absorption (Volume Change) 0% ASTM C209 Flame Spread / Smoke Development (up to 2” wall) <25/50 ASTM E84 Flammability Self-Extinguishing ASTM D635 Dimensional Stability <7% Linear Shrinkage ASTM C534 Hot Surface Performance (250°F for 96 hours) No Cracking or Delamination ASTM C411 Ozone Resistance Pass ASTM D1171 Odor Emissions No Objectionable Odor ASTM C1304 Chemical/Solvent/Oil/Grease Resistance Good Compatibility Data Available on Request Flexibility Excellent Pass: Cold Crack Test at -40°F (-40°C) ASTM C534 ASTM D1056 Mildew Growth Resistance/Air Erosion Pass UL 181, ASTM G21 Corrosion Risk pH neutral: 6.6±0.04 DIN 1988 Leachable Chlorides <0.05% water-soluble chloride ions DIN 1988 UV / Weather Resistance1 Pass QUV Chamber Test Sound Transmission Class (1”) 13 ASTM E90. ASTM C177, ASTM D1667, ASTM C534, ASTM E96, ASTM C209, ASTM E84, ASTM D635, ASTM C534, ASTM C411 ASTM D1171, ASTM C1304, ASTM C534, ASTM D1056, ASTM G21, ASTM E90, ASTM C 177, ASTM D 1667, ASTM C 534, ASTM E 96, ASTM C 209, ASTM E 84, ASTM D 635, ASTM C 534, ASTM C 411 ASTM D 1171, ASTM C 1304, ASTM C 534, ASTM D 1056, ASTM G 21, ASTM E 90, ASTM C-177, ASTM D-1667, ASTM C-534, ASTM E-96, ASTM C-209, ASTM E-84, ASTM D-635, ASTM C-534, ASTM C-411 ASTM D-1171, ASTM C-1304, ASTM C-534, ASTM D-1056, ASTM G-21, ASTM E-90tdsfittings
KFlexK-Flex K-Fit Rubber FittingsThermal Conductivity (K) 90°F (32°C) Mean Temp = 0.258 (0.0372) ASTM C177. Density 3-6 lb/ft3 ASTM D1667 Operating Temperature Range -297°F* (-183°C) to +220°F (104°C) ASTM C534 Water Vapor Permeability (Dry Cup) <0.01 perm-in ASTM E96 Water Absorption (Volume Change) 0% ASTM C209 Flame Spread / Smoke Development (up to 2” wall) <25/50 ASTM E84 Flammability Self-Extinguishing ASTM D635 Dimensional Stability <7% Linear Shrinkage ASTM C534 Hot Surface Performance (250°F for 96 hours) No Cracking or Delamination ASTM C411 Ozone Resistance Pass ASTM D1171 Odor Emissions No Objectionable Odor ASTM C1304 Chemical/Solvent/Oil/Grease Resistance Good Compatibility Data Available on Request Flexibility Excellent Pass: Cold Crack Test at -40°F (-40°C) ASTM C534 ASTM D1056 Mildew Growth Resistance/Air Erosion Pass UL 181, ASTM G21 Corrosion Risk pH neutral: 6.6±0.04 DIN 1988 Leachable Chlorides <0.05% water-soluble chloride ions DIN 1988 UV / Weather Resistance1 Pass QUV Chamber Test Sound Transmission Class (1”) 13 ASTM E90. ASTM C177, ASTM D1667, ASTM C534, ASTM E96, ASTM C209, ASTM E84, ASTM D635, ASTM C534, ASTM C411 ASTM D1171, ASTM C1304, ASTM C534, ASTM D1056, ASTM G21, ASTM E90, ASTM C 177, ASTM D 1667, ASTM C 534, ASTM E 96, ASTM C 209, ASTM E 84, ASTM D 635, ASTM C 534, ASTM C 411 ASTM D 1171, ASTM C 1304, ASTM C 534, ASTM D 1056, ASTM G 21, ASTM E 90, ASTM C-177, ASTM D-1667, ASTM C-534, ASTM E-96, ASTM C-209, ASTM E-84, ASTM D-635, ASTM C-534, ASTM C-411 ASTM D-1171, ASTM C-1304, ASTM C-534, ASTM D-1056, ASTM G-21, ASTM E-90sdsfittings
KnaufKnauf Atmosphere Air Duct Board with ECOSE TechnologyCorrosiveness ASTM C665 Does not accelerate corrosion of steel Linear Shrinkage ASTM C356 Less than 0.3% Maximum Service Temperature C411 450° F (232° C) Water Vapor Sorption (by weight) ASTM C1104 Less than 5% Water Vapor Permeance ASTM E96, Procedure A 0.02 perms Puncture Resistance TAPPI T803, Beach Units FSK facing: 25, ASJ facing: 50 Microbial Growth ASTM C1338 Pass Surface Burning Characteristics (flame spread/smoke developed) ASTM E84, UL 723, CAN/ULC S102, NFPA 90A and 90B UL/ULC Classified FHC 25/50. ASTM C612; Type IA (1.6, 2.25, 3.0, 4.25, 6.0 PCF) (26, 36, 48, 68, 96 kg/m³) Type IB (3.0, 4.25, 6.0 PCF) (48, 68, 96 kg/m³) ASTM C1136 (facings); Type II, IV (FSK), Type I, II (ASJ) California Title 24 CGSM 51-GP-10M.ASTM C1136, ASTM D5116, ASTM G21, ASTM C411, ASTM E96, ASTM C1104, ASTM G21, ASTM C 1136, ASTM D 5116, ASTM G 21, ASTM C 411, ASTM E 96, ASTM C 1104, ASTM G 21, ASTM C-1136, ASTM D-5116, ASTM G-21, ASTM C-411, ASTM E-96, ASTM C-1104, ASTM G-21tdsduct-board
KnaufKnauf Atmosphere Air Duct Board with ECOSE TechnologyCorrosiveness ASTM C665 Does not accelerate corrosion of steel Linear Shrinkage ASTM C356 Less than 0.3% Maximum Service Temperature C411 450° F (232° C) Water Vapor Sorption (by weight) ASTM C1104 Less than 5% Water Vapor Permeance ASTM E96, Procedure A 0.02 perms Puncture Resistance TAPPI T803, Beach Units FSK facing: 25, ASJ facing: 50 Microbial Growth ASTM C1338 Pass Surface Burning Characteristics (flame spread/smoke developed) ASTM E84, UL 723, CAN/ULC S102, NFPA 90A and 90B UL/ULC Classified FHC 25/50. ASTM C612; Type IA (1.6, 2.25, 3.0, 4.25, 6.0 PCF) (26, 36, 48, 68, 96 kg/m³) Type IB (3.0, 4.25, 6.0 PCF) (48, 68, 96 kg/m³) ASTM C1136 (facings); Type II, IV (FSK), Type I, II (ASJ) California Title 24 CGSM 51-GP-10M.ASTM C1136, ASTM D5116, ASTM G21, ASTM C411, ASTM E96, ASTM C1104, ASTM G21, ASTM C 1136, ASTM D 5116, ASTM G 21, ASTM C 411, ASTM E 96, ASTM C 1104, ASTM G 21, ASTM C-1136, ASTM D-5116, ASTM G-21, ASTM C-411, ASTM E-96, ASTM C-1104, ASTM G-21sdsduct-board
KnaufKnauf EcoBatt Fiberglass InsulationASTM C1617, ASTM C518, ASTM E96, ASTM C1104, ASTM E136, ASTM C1338, ASTM E84, ASTM C665 (facing); • Type I, Class A, (Unfaced) • Type II, Class C, Category 1 (Kraft) • Type III, Class A, Category 1 (FSK-25 foil) • Type III, Class B, Category 1 (Foil) • California Energy Commission • MEA #498-90-M • State of Minnesota.ASTM C1617, ASTM C518, ASTM E96, ASTM C1104, ASTM E136, ASTM C1338, ASTM E84, ASTM C 1617, ASTM C 518, ASTM E 96, ASTM C 1104, ASTM E 136, ASTM C 1338, ASTM E 84, ASTM C-1617, ASTM C-518, ASTM E-96, ASTM C-1104, ASTM E-136, ASTM C-1338, ASTM E-84sdsbatts
KnaufKnauf EcoBatt Fiberglass InsulationASTM C1617, ASTM C518, ASTM E96, ASTM C1104, ASTM E136, ASTM C1338, ASTM E84, ASTM C665 (facing); • Type I, Class A, (Unfaced) • Type II, Class C, Category 1 (Kraft) • Type III, Class A, Category 1 (FSK-25 foil) • Type III, Class B, Category 1 (Foil) • California Energy Commission • MEA #498-90-M • State of Minnesota.ASTM C1617, ASTM C518, ASTM E96, ASTM C1104, ASTM E136, ASTM C1338, ASTM E84, ASTM C 1617, ASTM C 518, ASTM E 96, ASTM C 1104, ASTM E 136, ASTM C 1338, ASTM E 84, ASTM C-1617, ASTM C-518, ASTM E-96, ASTM C-1104, ASTM E-136, ASTM C-1338, ASTM E-84tdsbatts
MansonManson AK Board Fiberglass InsulationCorrosiveness ASTM C665 Does not accelerate corrosion of steel Linear Shrinkage ASTM C356 Less than 0.3% Maximum Service Temperature C411 450° F (232° C) Water Vapor Sorption (by weight) ASTM C1104 Less than 5% Water Vapor Permeance ASTM E96, Procedure A 0.02 perms Puncture Resistance TAPPI T803, Beach Units FSK facing: 25, ASJ facing: 50 Microbial Growth ASTM C1338 Pass Surface Burning Characteristics (flame spread/smoke developed) ASTM E84, UL 723, CAN/ULC S102, NFPA 90A and 90B UL/ULC Classified FHC 25/50. ASTM C612; Type IA (1.6, 2.25, 3.0, 4.25, 6.0 PCF) (26, 36, 48, 68, 96 kg/m³) Type IB (3.0, 4.25, 6.0 PCF) (48, 68, 96 kg/m³) ASTM C1136 (facings); Type II, IV (FSK), Type I, II (ASJ) California Title 24 CGSM 51-GP-10MASTM C612, ASTM C1136, ASTM E96, ASTM C1104, ASTM C356, ASTM C1338, ASTM C665, ASTM E84, ASTM C 612, ASTM C 1136, ASTM E 96, ASTM C 1104, ASTM C 356, ASTM C 1338, ASTM C 665, ASTM E 84, ASTM C-612, ASTM C-1136, ASTM E-96, ASTM C-1104, ASTM C-356, ASTM C-1338, ASTM C-665, ASTM E-84tdsduct-board
MansonManson AK Board Fiberglass InsulationCorrosiveness ASTM C665 Does not accelerate corrosion of steel Linear Shrinkage ASTM C356 Less than 0.3% Maximum Service Temperature C411 450° F (232° C) Water Vapor Sorption (by weight) ASTM C1104 Less than 5% Water Vapor Permeance ASTM E96, Procedure A 0.02 perms Puncture Resistance TAPPI T803, Beach Units FSK facing: 25, ASJ facing: 50 Microbial Growth ASTM C1338 Pass Surface Burning Characteristics (flame spread/smoke developed) ASTM E84, UL 723, CAN/ULC S102, NFPA 90A and 90B UL/ULC Classified FHC 25/50. ASTM C612; Type IA (1.6, 2.25, 3.0, 4.25, 6.0 PCF) (26, 36, 48, 68, 96 kg/m³) Type IB (3.0, 4.25, 6.0 PCF) (48, 68, 96 kg/m³) ASTM C1136 (facings); Type II, IV (FSK), Type I, II (ASJ) California Title 24 CGSM 51-GP-10MASTM C612, ASTM C1136, ASTM E96, ASTM C1104, ASTM C356, ASTM C1338, ASTM C665, ASTM E84, ASTM C 612, ASTM C 1136, ASTM E 96, ASTM C 1104, ASTM C 356, ASTM C 1338, ASTM C 665, ASTM E 84, ASTM C-612, ASTM C-1136, ASTM E-96, ASTM C-1104, ASTM C-356, ASTM C-1338, ASTM C-665, ASTM E-84sdsduct-board
MansonManson AK Flex Fiberglass Pipe & Tank InsulationCorrosiveness ASTM C665 Does not accelerate corrosion of steel Linear Shrinkage ASTM C356 Less than 0.3% Water Vapor Sorption (by weight) ASTM C1104 5% or less Water Vapor Permeance ASTM E96, Procedure A 0.02 perms (FSK, ASJ facing) Puncture Resistance TAPPI Test T803, Beach Units FSK facing: 25, ASJ facing: 50 Microbial Growth ASTM C1338 Pass Surface Burning Characteristics (flame spread/smoke developed) ASTM E84, UL 723, CAN/ULC S102 UL/ULC Classified FHC 25/50. ASTM C1393; Types I, II, IIIA, IIIB; Category 2 ASTM C1136 (facings); FSK: Type II, ASJ: Type I, II California Title 24 CGSM 51-GP-10M.ASTM C612, ASTM C1136, ASTM E96, ASTM C1104, ASTM C356, ASTM C1338, ASTM C665, ASTM E84, ASTM C 612, ASTM C 1136, ASTM E 96, ASTM C 1104, ASTM C 356, ASTM C 1338, ASTM C 665, ASTM E 84, ASTM C-612, ASTM C-1136, ASTM E-96, ASTM C-1104, ASTM C-356, ASTM C-1338, ASTM C-665, ASTM E-84tdspipe-and-tank
MansonManson AK Flex Fiberglass Pipe & Tank InsulationCorrosiveness ASTM C665 Does not accelerate corrosion of steel Linear Shrinkage ASTM C356 Less than 0.3% Water Vapor Sorption (by weight) ASTM C1104 5% or less Water Vapor Permeance ASTM E96, Procedure A 0.02 perms (FSK, ASJ facing) Puncture Resistance TAPPI Test T803, Beach Units FSK facing: 25, ASJ facing: 50 Microbial Growth ASTM C1338 Pass Surface Burning Characteristics (flame spread/smoke developed) ASTM E84, UL 723, CAN/ULC S102 UL/ULC Classified FHC 25/50. ASTM C1393; Types I, II, IIIA, IIIB; Category 2 ASTM C1136 (facings); FSK: Type II, ASJ: Type I, II California Title 24 CGSM 51-GP-10M.ASTM C612, ASTM C1136, ASTM E96, ASTM C1104, ASTM C356, ASTM C1338, ASTM C665, ASTM E84, ASTM C 612, ASTM C 1136, ASTM E 96, ASTM C 1104, ASTM C 356, ASTM C 1338, ASTM C 665, ASTM E 84, ASTM C-612, ASTM C-1136, ASTM E-96, ASTM C-1104, ASTM C-356, ASTM C-1338, ASTM C-665, ASTM E-84sdspipe-and-tank
MansonManson Akousti-Liner Flexible Fiberglass Duct LinerCorrosiveness ASTM C665 Does not accelerate corrosion of steel Corrosion ASMT C1617 Pass Maximum Service Temperature ASTM C411 250° F (121° C) Maximum Air Velocity ASTM C1071, UL 181 Erosion Test Max. 6,000 ft./min. (30.5 m/sec.) Tested to 15,000 ft./min. (76.2 m/sec.) Water Vapor Sorption (by weight) ASTM C1104 Less than 3% Microbial Growth ASTM C1338, ASTM G21, ASTM G22 Pass Surface Burning Characteristics (flame spread/smoke developed) ASTM E84, UL 723, CAN/ULC S102 UL/ULC Classified FHC 25/5. ASTM C1071; Type I NFPA 90A and NFPA 90B CAN/CGSB 51.11-92 ASHRAE 62 CAN/ULS S102 ASTM G21 and G22.ASTM C1071, ASTM E84, ASTM C1071, ASTM C1104, ASTM C665, ASTM G22, ASTM C1338, ASTM G21, ASTM C411, ASTM C 1071, ASTM E 84, ASTM C 1071, ASTM C 1104, ASTM C 665, ASTM G 22, ASTM C 1338, ASTM G 21, ASTM C 411, ASTM C-1071, ASTM E-84, ASTM C-1071, ASTM C-1104, ASTM C-665, ASTM G-22, ASTM C-1338, ASTM G-21, ASTM C-411tdsduct-liner
MansonManson Akousti-Liner Flexible Fiberglass Duct LinerCorrosiveness ASTM C665 Does not accelerate corrosion of steel Corrosion ASMT C1617 Pass Maximum Service Temperature ASTM C411 250° F (121° C) Maximum Air Velocity ASTM C1071, UL 181 Erosion Test Max. 6,000 ft./min. (30.5 m/sec.) Tested to 15,000 ft./min. (76.2 m/sec.) Water Vapor Sorption (by weight) ASTM C1104 Less than 3% Microbial Growth ASTM C1338, ASTM G21, ASTM G22 Pass Surface Burning Characteristics (flame spread/smoke developed) ASTM E84, UL 723, CAN/ULC S102 UL/ULC Classified FHC 25/5. ASTM C1071; Type I NFPA 90A and NFPA 90B CAN/CGSB 51.11-92 ASHRAE 62 CAN/ULS S102 ASTM G21 and G22.ASTM C1071, ASTM E84, ASTM C1071, ASTM C1104, ASTM C665, ASTM G22, ASTM C1338, ASTM G21, ASTM C411, ASTM C 1071, ASTM E 84, ASTM C 1071, ASTM C 1104, ASTM C 665, ASTM G 22, ASTM C 1338, ASTM G 21, ASTM C 411, ASTM C-1071, ASTM E-84, ASTM C-1071, ASTM C-1104, ASTM C-665, ASTM G-22, ASTM C-1338, ASTM G-21, ASTM C-411sdsduct-liner
MansonManson Akousti-Liner R Rigid Fiberglass Duct LinerCorrosiveness ASTM C665 Does not accelerate corrosion of steel Corrosion ASMT C1617 Pass Maximum Service Temperature ASTM C411 250° F (121° C) Maximum Air Velocity ASTM C1071, UL 181 Erosion Test Max. 6,000 ft./min. (30.5 m/sec.) Tested to 15,000 ft./min. (76.2 m/sec.) Water Vapor Sorption (by weight) ASTM C1104 Less than 3% Microbial Growth ASTM C1338, ASTM G21, ASTM G22 Pass Surface Burning Characteristics (flame spread/smoke developed) ASTM E84, UL 723, CAN/ULC S102 UL/ULC Classified FHC 25/50.SPECIFICATION COMPLIANCE ASTM C1071; Type II NFPA 90A and NFPA 90B CGSB 51.11-92 ASHRAE 62.ASTM C665, ASMT C1617, ASTM C411, ASTM C1071, ASTM C1104, ASTM C1338, ASTM G21, ASTM G22, ASTM E84, ASTM C1071, ASTM C 665, ASMT C 1617, ASTM C 411, ASTM C 1071, ASTM C 1104, ASTM C 1338, ASTM G 21, ASTM G 22, ASTM E 84, ASTM C 1071, ASTM C-665, ASMT C-1617, ASTM C-411, ASTM C-1071, ASTM C-1104, ASTM C-1338, ASTM G-21, ASTM G-22, ASTM E-84, ASTM C-1071tdsduct-liner
MansonManson Akousti-Liner R Rigid Fiberglass Duct LinerCorrosiveness ASTM C665 Does not accelerate corrosion of steel Corrosion ASMT C1617 Pass Maximum Service Temperature ASTM C411 250° F (121° C) Maximum Air Velocity ASTM C1071, UL 181 Erosion Test Max. 6,000 ft./min. (30.5 m/sec.) Tested to 15,000 ft./min. (76.2 m/sec.) Water Vapor Sorption (by weight) ASTM C1104 Less than 3% Microbial Growth ASTM C1338, ASTM G21, ASTM G22 Pass Surface Burning Characteristics (flame spread/smoke developed) ASTM E84, UL 723, CAN/ULC S102 UL/ULC Classified FHC 25/50.SPECIFICATION COMPLIANCE ASTM C1071; Type II NFPA 90A and NFPA 90B CGSB 51.11-92 ASHRAE 62.ASTM C665, ASMT C1617, ASTM C411, ASTM C1071, ASTM C1104, ASTM C1338, ASTM G21, ASTM G22, ASTM E84, ASTM C1071, ASTM C 665, ASMT C 1617, ASTM C 411, ASTM C 1071, ASTM C 1104, ASTM C 1338, ASTM G 21, ASTM G 22, ASTM E 84, ASTM C 1071, ASTM C-665, ASMT C-1617, ASTM C-411, ASTM C-1071, ASTM C-1104, ASTM C-1338, ASTM G-21, ASTM G-22, ASTM E-84, ASTM C-1071sdsduct-liner
MansonManson Alley Wrap B Fiberglass Duct WrapCorrosiveness ASTM C665 Does not accelerate corrosion of steel Corrosion ASTM C1617 Pass Water Vapor Permeance ASTM E96, Procedure A 0.02 perms Maximum Service Temperature ASTM C411 Faced: 250° F (121° C), Unfaced: 350° F (177° C) Mold Growth ASTM C1338 Pass Water Vapor Sorption (by weight) ASTM C1104 5% or less Surface Burning Characteristics (flame spread/smoke developed) ASTM E84, CAN/ULC S102, UL 723 Unfaced, FSK: UL/ULC Classified FHC 25/50 ASTM E84 PSK: 25/50. SPECIFICATION COMPLIANCE In U.S. ASTM C1290 Type I - unfaced Type II, III - faced ASTM C553 Type I, Type II - 0.75 PCF (12 kg/m³) Type I, Type II - 1.0 PCF (16 kg/m³) Type I, II, III - 1.5 PCF (24 kg/m³) ASTM C1136; Type II California Title 24 (installed at 25% compression) NFPA 90A and 90B In Canada CAN/CGSB 51. 11-92.ASTM C1139, ASTM C553, ASTM C1136, ASTM C1290, ASTM C411, ASTM E96, ASTM C1104, ASTM C665, ASTM C1617, ASTM C1338, ASTM C 1139, ASTM C 553, ASTM C 1136, ASTM C 1290, ASTM C 411, ASTM E 96, ASTM C 1104, ASTM C 665, ASTM C 1617, ASTM C 1338, ASTM C-1139, ASTM C-553, ASTM C-1136, ASTM C-1290, ASTM C-411, ASTM E-96, ASTM C-1104, ASTM C-665, ASTM C-1617, ASTM C-1338tdsduct-wraps
MansonManson Alley Wrap B Fiberglass Duct WrapCorrosiveness ASTM C665 Does not accelerate corrosion of steel Corrosion ASTM C1617 Pass Water Vapor Permeance ASTM E96, Procedure A 0.02 perms Maximum Service Temperature ASTM C411 Faced: 250° F (121° C), Unfaced: 350° F (177° C) Mold Growth ASTM C1338 Pass Water Vapor Sorption (by weight) ASTM C1104 5% or less Surface Burning Characteristics (flame spread/smoke developed) ASTM E84, CAN/ULC S102, UL 723 Unfaced, FSK: UL/ULC Classified FHC 25/50 ASTM E84 PSK: 25/50. SPECIFICATION COMPLIANCE In U.S. ASTM C1290 Type I - unfaced Type II, III - faced ASTM C553 Type I, Type II - 0.75 PCF (12 kg/m³) Type I, Type II - 1.0 PCF (16 kg/m³) Type I, II, III - 1.5 PCF (24 kg/m³) ASTM C1136; Type II California Title 24 (installed at 25% compression) NFPA 90A and 90B In Canada CAN/CGSB 51. 11-92.ASTM C1139, ASTM C553, ASTM C1136, ASTM C1290, ASTM C411, ASTM E96, ASTM C1104, ASTM C665, ASTM C1617, ASTM C1338, ASTM C 1139, ASTM C 553, ASTM C 1136, ASTM C 1290, ASTM C 411, ASTM E 96, ASTM C 1104, ASTM C 665, ASTM C 1617, ASTM C 1338, ASTM C-1139, ASTM C-553, ASTM C-1136, ASTM C-1290, ASTM C-411, ASTM E-96, ASTM C-1104, ASTM C-665, ASTM C-1617, ASTM C-1338sdsduct-wraps
MansonManson Alley-K Fiberglass Pipe InsulationCorrosiveness ASTM C665 Does not accelerate corrosion of steel Corrosion ASTM C1617 Pass Linear Shrinkage ASTM C356 Less than 0.3% Maximum Service Temperature C411 1000° F (538° C) Water Vapor Sorption (by weight) ASTM C1104 Less than 5% Water Vapor Permeance ASTM E96 0.02 perms Puncture Resistance TAPPI T803, Beach Units Min. rating of 50 Microbial Growth ASTM C1338 Pass Surface Burning Characteristics (flame spread/smoke developed) ASTM E84, UL 723, CAN/ULC S102 UL/ULC Classified FHC 25/50. SPECIFICATION COMPLIANCE ASTM C547; Type I, Type IV ASTM C585 MIL-DTL-32585; Type I, Form 4, Facing A and D UL/ULC Classified ASTM C795 MIL-I-24244 NRC Reg. Guide 1.36 (Certification needs to be specified at the time of the order) USCG 164.109/A4/0.ASTM C547, ASTM C795, ASTM C585, ASTM C1338, ASTM C356, ASTM C1136, ASTM E96, ASTM E84, ASTM C411, ASTM C871, ASTM C665, ASTM C1104, ASTM C 547, ASTM C 795, ASTM C 585, ASTM C 1338, ASTM C 356, ASTM C 1136, ASTM E 96, ASTM E 84, ASTM C 411, ASTM C 871, ASTM C 665, ASTM C 1104, ASTM C-547, ASTM C-795, ASTM C-585, ASTM C-1338, ASTM C-356, ASTM C-1136, ASTM E-96, ASTM E-84, ASTM C-411, ASTM C-871, ASTM C-665, ASTM C-1104tdspipe-insulation
MansonManson Alley-K Fiberglass Pipe InsulationCorrosiveness ASTM C665 Does not accelerate corrosion of steel Corrosion ASTM C1617 Pass Linear Shrinkage ASTM C356 Less than 0.3% Maximum Service Temperature C411 1000° F (538° C) Water Vapor Sorption (by weight) ASTM C1104 Less than 5% Water Vapor Permeance ASTM E96 0.02 perms Puncture Resistance TAPPI T803, Beach Units Min. rating of 50 Microbial Growth ASTM C1338 Pass Surface Burning Characteristics (flame spread/smoke developed) ASTM E84, UL 723, CAN/ULC S102 UL/ULC Classified FHC 25/50. SPECIFICATION COMPLIANCE ASTM C547; Type I, Type IV ASTM C585 MIL-DTL-32585; Type I, Form 4, Facing A and D UL/ULC Classified ASTM C795 MIL-I-24244 NRC Reg. Guide 1.36 (Certification needs to be specified at the time of the order) USCG 164.109/A4/0.ASTM C547, ASTM C795, ASTM C585, ASTM C1338, ASTM C356, ASTM C1136, ASTM E96, ASTM E84, ASTM C411, ASTM C871, ASTM C665, ASTM C1104, ASTM C 547, ASTM C 795, ASTM C 585, ASTM C 1338, ASTM C 356, ASTM C 1136, ASTM E 96, ASTM E 84, ASTM C 411, ASTM C 871, ASTM C 665, ASTM C 1104, ASTM C-547, ASTM C-795, ASTM C-585, ASTM C-1338, ASTM C-356, ASTM C-1136, ASTM E-96, ASTM E-84, ASTM C-411, ASTM C-871, ASTM C-665, ASTM C-1104sdspipe-insulation
MansonManson Fiberglass High Temperature Batt & HD BlanketASTM C1139 (withdrawn 2019); Type I Grade 3, Type 2 Grade 3 -ASTM C553; Type I, II, V, VI -ASTM C795 -MIL-I-24244 -NRC Reg. Guide 1.36 (Certification needs to be specified at the time of the order) -USCG 164.109/A18/0. Corrosiveness (ASTM C665), Does not accelerate corrosion of steel Corrosion (ASTM C1617) Pass Maximum Service Temperature (ASTM C411) 1000° F (538° C) Water Vapor Sorption, by weight (ASTM C1104) Less than 5% Mold Growth: (ASTM C1338) Pass Surface Burning Characteristics, flame spread/smoke developed (ASTM E84, UL 723, CAN/ULC S102 UL/ULC) Classified FHC 25/50.ASTM C1139, ASTM C553, ASTM C795 -MIL-I-24244, ASTM C665, ASTM C1617, ASTM C411, ASTM C1104, ASTM C1338, ASTM E84, UL 723, CAN/ULC S102 UL/ULC. ASTM C 1139, ASTM C 553, ASTM C 795, MIL I 24244, ASTM C 665, ASTM C 1617, ASTM C 411, ASTM C 1104, ASTM C 1338, ASTM E 84, UL 723, CAN/ULC S 102 UL/ULC. ASTM C-1139, ASTM C-553, ASTM C-795, MIL-I-24244, ASTM C-665, ASTM C-1617, ASTM C-411, ASTM C-1104, ASTM C-1338, ASTM E-84, UL-723, CAN/ULC S-102 UL/ULC. tdshigh-temperature-blanket
MansonManson Fiberglass High Temperature Batt & HD BlanketASTM C1139 (withdrawn 2019); Type I Grade 3, Type 2 Grade 3 -ASTM C553; Type I, II, V, VI -ASTM C795 -MIL-I-24244 -NRC Reg. Guide 1.36 (Certification needs to be specified at the time of the order) -USCG 164.109/A18/0. Corrosiveness (ASTM C665), Does not accelerate corrosion of steel Corrosion (ASTM C1617) Pass Maximum Service Temperature (ASTM C411) 1000° F (538° C) Water Vapor Sorption, by weight (ASTM C1104) Less than 5% Mold Growth: (ASTM C1338) Pass Surface Burning Characteristics, flame spread/smoke developed (ASTM E84, UL 723, CAN/ULC S102 UL/ULC) Classified FHC 25/50.ASTM C1139, ASTM C553, ASTM C795 -MIL-I-24244, ASTM C665, ASTM C1617, ASTM C411, ASTM C1104, ASTM C1338, ASTM E84, UL 723, CAN/ULC S102 UL/ULC. ASTM C 1139, ASTM C 553, ASTM C 795, MIL I 24244, ASTM C 665, ASTM C 1617, ASTM C 411, ASTM C 1104, ASTM C 1338, ASTM E 84, UL 723, CAN/ULC S 102 UL/ULC. ASTM C-1139, ASTM C-553, ASTM C-795, MIL-I-24244, ASTM C-665, ASTM C-1617, ASTM C-411, ASTM C-1104, ASTM C-1338, ASTM E-84, UL-723, CAN/ULC S-102 UL/ULC. sdshigh-temperature-blanket
MansonManson Fiberglass High Temperature BlanketCorrosiveness ASTM C665 Does not accelerate corrosion of steel Corrosion ASTM C1617 Pass Maximum Service Temperature ASTM C411 1000° F (538° C) Water Vapor Sorption (by weight) ASTM C1104 Less than 5% Mold Growth ASTM C1338 Pass Surface Burning Characteristics (flame spread/smoke developed) ASTM E84, UL 723, CAN/ULC S102 UL/ULC Classified FHC 25/50. SPECIFICATION COMPLIANCE ASTM C1139 (withdrawn 2019); Type I Grade 2, Type II Grade 2 ASTM C553; Type I, II, V MIL-DTL-32585; Type I, Form 2, Facing A ASTM C795 MIL-I-24244 NRC Reg. Guide 1.36 (Certification needs to be specified at the time of the order) USCG 164.109/A18/0.ASTM C665, ASTM C411, ASTM C1104, ASTM C1338, ASTM E84, ASTM C1139, ASTM C553, ASTM C795, ASTM C 665, ASTM C 411, ASTM C 1104, ASTM C 1338, ASTM E 84, ASTM C 1139, ASTM C 553, ASTM C 795, ASTM C-665, ASTM C-411, ASTM C-1104, ASTM C-1338, ASTM E-84, ASTM C-1139, ASTM C-553, ASTM C-795sdshigh-temperature-blanket
MansonManson Fiberglass High Temperature BlanketCorrosiveness ASTM C665 Does not accelerate corrosion of steel Corrosion ASTM C1617 Pass Maximum Service Temperature ASTM C411 1000° F (538° C) Water Vapor Sorption (by weight) ASTM C1104 Less than 5% Mold Growth ASTM C1338 Pass Surface Burning Characteristics (flame spread/smoke developed) ASTM E84, UL 723, CAN/ULC S102 UL/ULC Classified FHC 25/50. SPECIFICATION COMPLIANCE ASTM C1139 (withdrawn 2019); Type I Grade 2, Type II Grade 2 ASTM C553; Type I, II, V MIL-DTL-32585; Type I, Form 2, Facing A ASTM C795 MIL-I-24244 NRC Reg. Guide 1.36 (Certification needs to be specified at the time of the order) USCG 164.109/A18/0.ASTM C665, ASTM C411, ASTM C1104, ASTM C1338, ASTM E84, ASTM C1139, ASTM C553, ASTM C795, ASTM C 665, ASTM C 411, ASTM C 1104, ASTM C 1338, ASTM E 84, ASTM C 1139, ASTM C 553, ASTM C 795, ASTM C-665, ASTM C-411, ASTM C-1104, ASTM C-1338, ASTM E-84, ASTM C-1139, ASTM C-553, ASTM C-795tdshigh-temperature-blanket
MansonManson Fiberglass High Temperature BoardCorrosiveness (ASTM C665) Does not accelerate corrosion of steel Corrosion (ASTM C1617) Pass Maximum Service Temperature (ASTM C411) 1000° F (538° C) Mold Growth (ASTM C1338) Pass Surface Burning Characteristics, flame spread/smoke developed (ASTM E84, UL 723, CAN/ULC S102 UL/ULC) Classified FHC 25/50 Specification Compliance -ASTM C612; Types IA, IB, II and III; Category I -ASTM C1139; Type III (withdrawn 2019) -MIL-DTL-32585; Type I, Form I, Facing A -ASTM C795 -MIL-I-24244 -NRC Reg. Guide 1.36 (Certification needs to be specified at the time of the order) -USCG 164.109/A15/0.ASTM C665, ASTM C1617, ASTM C411, ASTM C1338, ASTM E84, ASTM C612, ASTM C1139, MIL-DTL-32585, ASTM C795. ASTM C 665, ASTM C 1617, ASTM C 411, ASTM C 1338, ASTM E 84, ASTM C 612, ASTM C 1139, MIL DTL 32585, ASTM C 795. ASTM C-665, ASTM C-1617, ASTM C-411, ASTM C-1338, ASTM E-84, ASTM C-612, ASTM C-1139, MIL-DTL-32585, ASTM C-795.tdshigh-temperature-blanket
MansonManson Fiberglass High Temperature BoardCorrosiveness (ASTM C665) Does not accelerate corrosion of steel Corrosion (ASTM C1617) Pass Maximum Service Temperature (ASTM C411) 1000° F (538° C) Mold Growth (ASTM C1338) Pass Surface Burning Characteristics, flame spread/smoke developed (ASTM E84, UL 723, CAN/ULC S102 UL/ULC) Classified FHC 25/50 Specification Compliance -ASTM C612; Types IA, IB, II and III; Category I -ASTM C1139; Type III (withdrawn 2019) -MIL-DTL-32585; Type I, Form I, Facing A -ASTM C795 -MIL-I-24244 -NRC Reg. Guide 1.36 (Certification needs to be specified at the time of the order) -USCG 164.109/A15/0.ASTM C665, ASTM C1617, ASTM C411, ASTM C1338, ASTM E84, ASTM C612, ASTM C1139, MIL-DTL-32585, ASTM C795. ASTM C 665, ASTM C 1617, ASTM C 411, ASTM C 1338, ASTM E 84, ASTM C 612, ASTM C 1139, MIL DTL 32585, ASTM C 795. ASTM C-665, ASTM C-1617, ASTM C-411, ASTM C-1338, ASTM E-84, ASTM C-612, ASTM C-1139, MIL-DTL-32585, ASTM C-795.sdshigh-temperature-blanket
MansonManson Fiberglass High Temperature PanelCorrosiveness (ASTM C665) -Does not accelerate corrosion of steel Corrosion (ASTM C1617) -Pass Maximum Service Temperature (ASTM C411) -1000° F (538° C) Water Vapor Sorption, by weight (ASTM C1104) -Less than 5% Mold Growth (ASTM C1338) -Pass Surface Burning Characteristics: (flame spread/smoke developed) ASTM E84, UL 723, CAN/ULC S102 UL/ULC -Classified FHC 25/50 Specification Compliance: -ASTM C612; Type IA, Type IB, Type II and III, Category I -ASTM C1139; Type I, Grade 5, Type II, Grade 5 (withdrawn 2019) -ASTM C795 -MIL-I-24244 -NRC Reg. Guide 1.36 (Certification needs to be specified at the time of the order) -USCG 164.109/A15/0ASTM C665, ASTM C1617, ASTM C411, ASTM C1104, ASTM C1338, ASTM E84, ASTM C612, ASTM C1139, ASTM C795, MIL I24244. ASTM C 665, ASTM C 1617, ASTM C 411, ASTM C 1104, ASTM C 1338, ASTM E 84, ASTM C 612, ASTM C 1139, ASTM C 795, MIL I 24244. ASTM C-665, ASTM C-1617, ASTM C-411, ASTM C-1104, ASTM C-1338, ASTM E-84, ASTM C-612, ASTM C-1139, ASTM C-795, MIL-I-24244. tdshigh-temperature-blanket
MansonManson Fiberglass High Temperature PanelCorrosiveness (ASTM C665) -Does not accelerate corrosion of steel Corrosion (ASTM C1617) -Pass Maximum Service Temperature (ASTM C411) -1000° F (538° C) Water Vapor Sorption, by weight (ASTM C1104) -Less than 5% Mold Growth (ASTM C1338) -Pass Surface Burning Characteristics: (flame spread/smoke developed) ASTM E84, UL 723, CAN/ULC S102 UL/ULC -Classified FHC 25/50 Specification Compliance: -ASTM C612; Type IA, Type IB, Type II and III, Category I -ASTM C1139; Type I, Grade 5, Type II, Grade 5 (withdrawn 2019) -ASTM C795 -MIL-I-24244 -NRC Reg. Guide 1.36 (Certification needs to be specified at the time of the order) -USCG 164.109/A15/0ASTM C665, ASTM C1617, ASTM C411, ASTM C1104, ASTM C1338, ASTM E84, ASTM C612, ASTM C1139, ASTM C795, MIL I24244. ASTM C 665, ASTM C 1617, ASTM C 411, ASTM C 1104, ASTM C 1338, ASTM E 84, ASTM C 612, ASTM C 1139, ASTM C 795, MIL I 24244. ASTM C-665, ASTM C-1617, ASTM C-411, ASTM C-1104, ASTM C-1338, ASTM E-84, ASTM C-612, ASTM C-1139, ASTM C-795, MIL-I-24244. sdshigh-temperature-blanket
MarkwellMarkwell G-26 Outward Clinch Tackertdsaccessories
MarkwellMarkwell G-26 Outward Clinch Tackersdsaccessories
MarkwellMarkwell G5 Tackertdsaccessories
MarkwellMarkwell G5 Tackersdsaccessories
NventnVent RACHEM XL-Trace Edge Self-Regulating Heating Cabletdsheat-trace-solutions
NventnVent RAYCHEM 460 Single Point Electronic Controller For Heat Tracing Systemstdsheat-trace-solutions
NventnVent RAYCHEM 465 Single Point Electronic Controller For Fire Protection Pipe Tracing Systemstdsheat-trace-solutions
NventnVent RAYCHEM AMC-F5 Thermostattdsheat-trace-solutions
NventnVent RAYCHEM C910-485 Single-Point Heat-Tracing Control Systemtdsheat-trace-solutions
NventnVent RAYCHEM EC-TS Ambient, Pipe or Slab Sensing Electronic Thermostat With 25-Foot Temperature Sensing Leadtdsheat-trace-solutions
NventnVent RAYCHEM RAYCLIC Connection Kittdsheat-trace-solutions
Pittsburgh CorningPittsburgh Corning Foamglas Block InsulationFOAMGLAS® insulation cannot burn because it consists of pure glass. Fire behavior classification: EN 13501: A1. ASTM E84 flame spread 0 / Smoke development 0.ASTM E84, ASTM E136, ASTM E 84, ASTM E 136, ASTM E-84, ASTM E-136tdsblock-insulation
Pittsburgh CorningPittsburgh Corning Foamglas Block InsulationFOAMGLAS® insulation cannot burn because it consists of pure glass. Fire behavior classification: EN 13501: A1. ASTM E84 flame spread 0 / Smoke development 0.ASTM E84, ASTM E136, ASTM E 84, ASTM E 136, ASTM E-84, ASTM E-136sdsblock-insulation
Pittsburgh CorningPittsburgh Corning Foamglas Fittings InsulationDENSITY, NOMINAL ASTM C303 117 kg / m3 7.3 lbs. / ft3 ABSORPTION OF MOISTURE ASTM C240 < 0.2% by Vol < 0.2% by Vol WATER VAPOR PERMEABILITY ASTM E96 Wet Cup 0.00 ng / PaÂVÂm 0.00 permÂinch CHEMICAL RESISTANCE Impervious to common acids and their fumes. CAPILLARITY None COMBUSTIBILITY & REACTION TO FIRE ASTM E136 ASTM E84 Non Combustible Flame Spread Index 0 Smoke Development Index 0 COMPOSITION Soda lime glass. Inorganic. No fibers or binders. CORROSION, WATER SOLUABLE IONS AND PH ASTM C871 ASTM C692 ASTM C1617 Acceptable for use with Stainless Steel Pass (0 Coupon Cracked) < DI Water COMPRESSIVE STRENGTH, BLOCK AVG ASTM ASTM C165 ASTM C240 ASTM C552 620 KPa 90 lbs / in2 DIMENSIONAL STABILITY Excellent – does not shrink or swell FLEXURAL STRENGTH, BLOCK AVG ASTM C203 ASTM C240 480 KPa 70 lbs / in2 HYGROSCOPICITY No increase in weight at 90% relative humidity. COEFFICIENT OF LINEAR THERMAL EXPANSION, AVG ASTM E228 25 to 300 °C 9.0 x 10-6 / K -170 to 25 °C 6.6 x 10-6 / K 75 to 575 °F 5.0 x 10-6 / °F -274 to 75 °F 3.7 x 10-6 / °F SERVICE TEMPERATURE -268 to 482 °C -450 to 900 °F MODULUS OF ELASTICITY, APPROXIMATE C623 900 MPa 1.3 x 105 lbsÂin-2 SPECIFIC HEAT E1461 0.77 kJ / kgÂK @ 25°C 0.18 BTU / lb  °F @ 77°F THERMAL DIFFUSIVITY E1461 4.2 x 10-7 m2 / s 0.016 ft2 / hr.ASTM C552, ASTM C1639, ASTM C795, ASTM C692, ASTM C871, ASTM E84, ASTM E814, ASTM C 552, ASTM C 1639, ASTM C 795, ASTM C 692, ASTM C 871, ASTM E 84, ASTM E 814, ASTM C-552, ASTM C-1639, ASTM C-795, ASTM C-692, ASTM C-871, ASTM E-84, ASTM E-814tdsfittings
Pittsburgh CorningPittsburgh Corning Foamglas Fittings InsulationDENSITY, NOMINAL ASTM C303 117 kg / m3 7.3 lbs. / ft3 ABSORPTION OF MOISTURE ASTM C240 < 0.2% by Vol < 0.2% by Vol WATER VAPOR PERMEABILITY ASTM E96 Wet Cup 0.00 ng / PaÂVÂm 0.00 permÂinch CHEMICAL RESISTANCE Impervious to common acids and their fumes. CAPILLARITY None COMBUSTIBILITY & REACTION TO FIRE ASTM E136 ASTM E84 Non Combustible Flame Spread Index 0 Smoke Development Index 0 COMPOSITION Soda lime glass. Inorganic. No fibers or binders. CORROSION, WATER SOLUABLE IONS AND PH ASTM C871 ASTM C692 ASTM C1617 Acceptable for use with Stainless Steel Pass (0 Coupon Cracked) < DI Water COMPRESSIVE STRENGTH, BLOCK AVG ASTM ASTM C165 ASTM C240 ASTM C552 620 KPa 90 lbs / in2 DIMENSIONAL STABILITY Excellent – does not shrink or swell FLEXURAL STRENGTH, BLOCK AVG ASTM C203 ASTM C240 480 KPa 70 lbs / in2 HYGROSCOPICITY No increase in weight at 90% relative humidity. COEFFICIENT OF LINEAR THERMAL EXPANSION, AVG ASTM E228 25 to 300 °C 9.0 x 10-6 / K -170 to 25 °C 6.6 x 10-6 / K 75 to 575 °F 5.0 x 10-6 / °F -274 to 75 °F 3.7 x 10-6 / °F SERVICE TEMPERATURE -268 to 482 °C -450 to 900 °F MODULUS OF ELASTICITY, APPROXIMATE C623 900 MPa 1.3 x 105 lbsÂin-2 SPECIFIC HEAT E1461 0.77 kJ / kgÂK @ 25°C 0.18 BTU / lb  °F @ 77°F THERMAL DIFFUSIVITY E1461 4.2 x 10-7 m2 / s 0.016 ft2 / hr.ASTM C552, ASTM C1639, ASTM C795, ASTM C692, ASTM C871, ASTM E84, ASTM E814, ASTM C 552, ASTM C 1639, ASTM C 795, ASTM C 692, ASTM C 871, ASTM E 84, ASTM E 814, ASTM C-552, ASTM C-1639, ASTM C-795, ASTM C-692, ASTM C-871, ASTM E-84, ASTM E-814sdsfittings
Pittsburgh CorningPittsburgh Corning FOAMGLAS HLB 1000 Cellular Glass Tank and Vessel InsulationABSORPTION OF MOISTURE ASTM C240 < 0.2% by Vol. THERMAL EXPANSION ASTM E228 "75 to 575 °F , 5.0 x 10^{-6} / °F -274 to 75 °F , 3.7 x 10^{-6} / °F". COMBUSTIBILITY ASTM E136 Noncombustible. COMPRESSIVE STRENGTH ASTM C165 / ASTM C240 / ASTM C552 LSL_{lot avg} =145 lb / in^{2}, LSL_{ind} =100 lb / in^{2} CORROSION, ASTM C871 Acceptable for use with stainless steel. WATER SOLUBLE ASTM C692 Pass. IONS AND PH ASTM C1617 < DI Water. DENSITY (+/-15%) ASTM C303 8.1 lb / ft^{3}. FLEXURAL STRENGTH ASTM C203 / ASTM C240 LSL = 51 lb / in^{2}. MODULUS OF ELASTICITY ASTM C623 1.8 x 10^{5} lb / in^{2}. SERVICE TEMPERATURE "Without Load -450 to 900 °F With Load -450 to 752 °F". SPECIFIC HEAT ASTM E1461 0.18 BTU / lb·°F @ 77°F. SURFACE BURNING CHARACTERISTICS ASTM E84 Flame Spread Index 0 / Smoke Development Index 0. WATER VAPOR PERMEABILITY ASTM E96 Wet Cup 0.00 perm·inch. FOAMGLAS® Insulation can be certified to conform to the requirements of: • ASTM C552 “Standard Specification for Cellular Glass Thermal Insulation” (Grade 10) • I-QC-HLB / ISO 3951 • Military Specification MIL-DLT-24244D (SH), with Special Corrosion and Chloride Requirement” • Nuclear Regulatory Guide 1.36, ASTM C795, C692, C871 • Flame Spread Index 0, Smoke Developed Index 0 (UL 723, ASTM E 84), UL R2844; also classified by UL of Canada • UL 1709, Rapid Rise Fire Tests of Protection Materials for Structural Steel.ASTM C552, ASTM C795, ASTM C692, ASTM C871, ASTM E84, ASTM C 552, ASTM C 795, ASTM C 692, ASTM C 871, ASTM E 84, ASTM C-552, ASTM C-795, ASTM C-692, ASTM C-871, ASTM E-84sdspipe-and-tank
Pittsburgh CorningPittsburgh Corning FOAMGLAS HLB 1000 Cellular Glass Tank and Vessel InsulationABSORPTION OF MOISTURE ASTM C240 < 0.2% by Vol. THERMAL EXPANSION ASTM E228 "75 to 575 °F , 5.0 x 10^{-6} / °F -274 to 75 °F , 3.7 x 10^{-6} / °F". COMBUSTIBILITY ASTM E136 Noncombustible. COMPRESSIVE STRENGTH ASTM C165 / ASTM C240 / ASTM C552 LSL_{lot avg} =145 lb / in^{2}, LSL_{ind} =100 lb / in^{2} CORROSION, ASTM C871 Acceptable for use with stainless steel. WATER SOLUBLE ASTM C692 Pass. IONS AND PH ASTM C1617 < DI Water. DENSITY (+/-15%) ASTM C303 8.1 lb / ft^{3}. FLEXURAL STRENGTH ASTM C203 / ASTM C240 LSL = 51 lb / in^{2}. MODULUS OF ELASTICITY ASTM C623 1.8 x 10^{5} lb / in^{2}. SERVICE TEMPERATURE "Without Load -450 to 900 °F With Load -450 to 752 °F". SPECIFIC HEAT ASTM E1461 0.18 BTU / lb·°F @ 77°F. SURFACE BURNING CHARACTERISTICS ASTM E84 Flame Spread Index 0 / Smoke Development Index 0. WATER VAPOR PERMEABILITY ASTM E96 Wet Cup 0.00 perm·inch. FOAMGLAS® Insulation can be certified to conform to the requirements of: • ASTM C552 “Standard Specification for Cellular Glass Thermal Insulation” (Grade 10) • I-QC-HLB / ISO 3951 • Military Specification MIL-DLT-24244D (SH), with Special Corrosion and Chloride Requirement” • Nuclear Regulatory Guide 1.36, ASTM C795, C692, C871 • Flame Spread Index 0, Smoke Developed Index 0 (UL 723, ASTM E 84), UL R2844; also classified by UL of Canada • UL 1709, Rapid Rise Fire Tests of Protection Materials for Structural Steel.ASTM C552, ASTM C795, ASTM C692, ASTM C871, ASTM E84, ASTM C 552, ASTM C 795, ASTM C 692, ASTM C 871, ASTM E 84, ASTM C-552, ASTM C-795, ASTM C-692, ASTM C-871, ASTM E-84tdspipe-and-tank
Pittsburgh CorningPittsburgh Corning FOAMGLAS HLB 1200 Cellular Glass Tank and Vessel InsulationABSORPTION OF MOISTURE ASTM C240 < 0.2% by Vol. THERMAL EXPANSION ASTM E228 "75 to 575 °F , 5.0 x 10^{-6} / °F -274 to 75 °F , 3.7 x 10^{-6} / °F". COMBUSTIBILITY ASTM E136 Noncombustible. COMPRESSIVE STRENGTH ASTM C165 / ASTM C240 / ASTM C552 LSL_{lot avg} =174 lb / in^{2}, LSL_{ind} =120 lb / in^{2} CORROSION, ASTM C871 Acceptable for use with stainless steel. WATER SOLUBLE ASTM C692 Pass. IONS AND PH ASTM C1617 < DI Water. DENSITY (+/-15%) ASTM C303 8.7 lb / ft^{3}. FLEXURAL STRENGTH ASTM C203 / ASTM C240 LSL = 51 lb / in^{2}. MODULUS OF ELASTICITY ASTM C623 2.0 x 10^{5} lb / in^{2}. SERVICE TEMPERATURE "Without Load -450 to 900 °F With Load -450 to 752 °F". SPECIFIC HEAT ASTM E1461 0.18 BTU / lb·°F @ 77°F. SURFACE BURNING CHARACTERISTICS ASTM E84 Flame Spread Index 0 / Smoke Development Index 0. WATER VAPOR PERMEABILITY ASTM E96 Wet Cup 0.00 perm·inch. FOAMGLAS® Insulation can be certified to conform to the requirements of: • ASTM C552 “Standard Specification for Cellular Glass Thermal Insulation” (Grade 12) • I-QC-HLB / ISO 3951 • Military Specification MIL-DLT-24244D (SH), with Special Corrosion and Chloride Requirement” • Nuclear Regulatory Guide 1.36, ASTM C795, C692, C871 • Flame Spread Index 0, Smoke Developed Index 0 (UL 723, ASTM E 84), UL R2844; also classified by UL of Canada • UL 1709, Rapid Rise Fire Tests of Protection Materials for Structural Steel.ASTM C552, ASTM C795, ASTM C692, ASTM C871, ASTM E84, ASTM C 552, ASTM C 795, ASTM C 692, ASTM C 871, ASTM E 84, ASTM C-552, ASTM C-795, ASTM C-692, ASTM C-871, ASTM E-84tdsfoamglas
Pittsburgh CorningPittsburgh Corning FOAMGLAS HLB 1200 Cellular Glass Tank and Vessel InsulationABSORPTION OF MOISTURE ASTM C240 < 0.2% by Vol. THERMAL EXPANSION ASTM E228 "75 to 575 °F , 5.0 x 10^{-6} / °F -274 to 75 °F , 3.7 x 10^{-6} / °F". COMBUSTIBILITY ASTM E136 Noncombustible. COMPRESSIVE STRENGTH ASTM C165 / ASTM C240 / ASTM C552 LSL_{lot avg} =174 lb / in^{2}, LSL_{ind} =120 lb / in^{2} CORROSION, ASTM C871 Acceptable for use with stainless steel. WATER SOLUBLE ASTM C692 Pass. IONS AND PH ASTM C1617 < DI Water. DENSITY (+/-15%) ASTM C303 8.7 lb / ft^{3}. FLEXURAL STRENGTH ASTM C203 / ASTM C240 LSL = 51 lb / in^{2}. MODULUS OF ELASTICITY ASTM C623 2.0 x 10^{5} lb / in^{2}. SERVICE TEMPERATURE "Without Load -450 to 900 °F With Load -450 to 752 °F". SPECIFIC HEAT ASTM E1461 0.18 BTU / lb·°F @ 77°F. SURFACE BURNING CHARACTERISTICS ASTM E84 Flame Spread Index 0 / Smoke Development Index 0. WATER VAPOR PERMEABILITY ASTM E96 Wet Cup 0.00 perm·inch. FOAMGLAS® Insulation can be certified to conform to the requirements of: • ASTM C552 “Standard Specification for Cellular Glass Thermal Insulation” (Grade 12) • I-QC-HLB / ISO 3951 • Military Specification MIL-DLT-24244D (SH), with Special Corrosion and Chloride Requirement” • Nuclear Regulatory Guide 1.36, ASTM C795, C692, C871 • Flame Spread Index 0, Smoke Developed Index 0 (UL 723, ASTM E 84), UL R2844; also classified by UL of Canada • UL 1709, Rapid Rise Fire Tests of Protection Materials for Structural Steel.ASTM C552, ASTM C795, ASTM C692, ASTM C871, ASTM E84, ASTM C 552, ASTM C 795, ASTM C 692, ASTM C 871, ASTM E 84, ASTM C-552, ASTM C-795, ASTM C-692, ASTM C-871, ASTM E-84sdsfoamglas
Pittsburgh CorningPittsburgh Corning FOAMGLAS HLB 1400 Cellular Glass Tank and Vessel InsulationABSORPTION OF MOISTURE ASTM C240 < 0.2% by Vol. THERMAL EXPANSION ASTM E228 "75 to 575 °F , 5.0 x 10^{-6} / °F -274 to 75 °F , 3.7 x 10^{-6} / °F". COMBUSTIBILITY ASTM E136 Noncombustible. COMPRESSIVE STRENGTH ASTM C165 / ASTM C240 / ASTM C552 LSL_{lot avg} = 203 lb / in^{2}, LSL_{ind} =140 lb / in^{2} CORROSION, ASTM C871 Acceptable for use with stainless steel. WATER SOLUBLE ASTM C692 Pass. IONS AND PH ASTM C1617 < DI Water. DENSITY (+/-15%) ASTM C303 9.4 lb / ft^{3}. FLEXURAL STRENGTH ASTM C203 / ASTM C240 LSL = 63 lb / in^{2}. MODULUS OF ELASTICITY ASTM C623 2.2 x 10^{5} lb / in^{2}. SERVICE TEMPERATURE "Without Load -450 to 900 °F With Load -450 to 752 °F". SPECIFIC HEAT ASTM E1461 0.18 BTU / lb·°F @ 77°F. SURFACE BURNING CHARACTERISTICS ASTM E84 Flame Spread Index 0 / Smoke Development Index 0. WATER VAPOR PERMEABILITY ASTM E96 Wet Cup 0.00 perm·inch. FOAMGLAS® Insulation can be certified to conform to the requirements of: • ASTM C552 “Standard Specification for Cellular Glass Thermal Insulation” (Grade 14) • I-QC-HLB / ISO 3951 • Military Specification MIL-DLT-24244D (SH), with Special Corrosion and Chloride Requirement” • Nuclear Regulatory Guide 1.36, ASTM C795, C692, C871 • Flame Spread Index 0, Smoke Developed Index 0 (UL 723, ASTM E 84), UL R2844; also classified by UL of Canada • UL 1709, Rapid Rise Fire Tests of Protection Materials for Structural Steel.ASTM C552, ASTM C795, ASTM C692, ASTM C871, ASTM E84, ASTM C 552, ASTM C 795, ASTM C 692, ASTM C 871, ASTM E 84, ASTM C-552, ASTM C-795, ASTM C-692, ASTM C-871, ASTM E-84tdspipe-and-tank
Pittsburgh CorningPittsburgh Corning FOAMGLAS HLB 1400 Cellular Glass Tank and Vessel InsulationABSORPTION OF MOISTURE ASTM C240 < 0.2% by Vol. THERMAL EXPANSION ASTM E228 "75 to 575 °F , 5.0 x 10^{-6} / °F -274 to 75 °F , 3.7 x 10^{-6} / °F". COMBUSTIBILITY ASTM E136 Noncombustible. COMPRESSIVE STRENGTH ASTM C165 / ASTM C240 / ASTM C552 LSL_{lot avg} = 203 lb / in^{2}, LSL_{ind} =140 lb / in^{2} CORROSION, ASTM C871 Acceptable for use with stainless steel. WATER SOLUBLE ASTM C692 Pass. IONS AND PH ASTM C1617 < DI Water. DENSITY (+/-15%) ASTM C303 9.4 lb / ft^{3}. FLEXURAL STRENGTH ASTM C203 / ASTM C240 LSL = 63 lb / in^{2}. MODULUS OF ELASTICITY ASTM C623 2.2 x 10^{5} lb / in^{2}. SERVICE TEMPERATURE "Without Load -450 to 900 °F With Load -450 to 752 °F". SPECIFIC HEAT ASTM E1461 0.18 BTU / lb·°F @ 77°F. SURFACE BURNING CHARACTERISTICS ASTM E84 Flame Spread Index 0 / Smoke Development Index 0. WATER VAPOR PERMEABILITY ASTM E96 Wet Cup 0.00 perm·inch. FOAMGLAS® Insulation can be certified to conform to the requirements of: • ASTM C552 “Standard Specification for Cellular Glass Thermal Insulation” (Grade 14) • I-QC-HLB / ISO 3951 • Military Specification MIL-DLT-24244D (SH), with Special Corrosion and Chloride Requirement” • Nuclear Regulatory Guide 1.36, ASTM C795, C692, C871 • Flame Spread Index 0, Smoke Developed Index 0 (UL 723, ASTM E 84), UL R2844; also classified by UL of Canada • UL 1709, Rapid Rise Fire Tests of Protection Materials for Structural Steel.ASTM C552, ASTM C795, ASTM C692, ASTM C871, ASTM E84, ASTM C 552, ASTM C 795, ASTM C 692, ASTM C 871, ASTM E 84, ASTM C-552, ASTM C-795, ASTM C-692, ASTM C-871, ASTM E-84sdspipe-and-tank
Pittsburgh CorningPittsburgh Corning FOAMGLAS HLB 1600 Cellular Glass Tank and Vessel InsulationABSORPTION OF MOISTURE ASTM C240 < 0.2% by Vol. THERMAL EXPANSION ASTM E228 "75 to 575 °F , 5.0 x 10^{-6} / °F -274 to 75 °F , 3.7 x 10^{-6} / °F". COMBUSTIBILITY ASTM E136 Noncombustible. COMPRESSIVE STRENGTH ASTM C165 / ASTM C240 / ASTM C552 LSL_{lot avg} = 232 lb / in^{2}, LSL_{ind} =160 lb / in^{2} CORROSION, ASTM C871 Acceptable for use with stainless steel. WATER SOLUBLE ASTM C692 Pass. IONS AND PH ASTM C1617 < DI Water. DENSITY (+/-15%) ASTM C303 10 lb / ft^{3}. FLEXURAL STRENGTH ASTM C203 / ASTM C240 LSL = 69 lb / in^{2}. MODULUS OF ELASTICITY ASTM C623 2.4 x 10^{5} lb / in^{2}. SERVICE TEMPERATURE "Without Load -450 to 900 °F With Load -450 to 752 °F". SPECIFIC HEAT ASTM E1461 0.18 BTU / lb·°F @ 77°F. SURFACE BURNING CHARACTERISTICS ASTM E84 Flame Spread Index 0 / Smoke Development Index 0. WATER VAPOR PERMEABILITY ASTM E96 Wet Cup 0.00 perm·inch. FOAMGLAS® Insulation can be certified to conform to the requirements of: • ASTM C552 “Standard Specification for Cellular Glass Thermal Insulation” (Grade 16) • I-QC-HLB / ISO 3951 • Military Specification MIL-DLT-24244D (SH), with Special Corrosion and Chloride Requirement” • Nuclear Regulatory Guide 1.36, ASTM C795, C692, C871 • Flame Spread Index 0, Smoke Developed Index 0 (UL 723, ASTM E 84), UL R2844; also classified by UL of Canada • UL 1709, Rapid Rise Fire Tests of Protection Materials for Structural Steel.ASTM C552, ASTM C795, ASTM C692, ASTM C871, ASTM E84, ASTM C 552, ASTM C 795, ASTM C 692, ASTM C 871, ASTM E 84, ASTM C-552, ASTM C-795, ASTM C-692, ASTM C-871, ASTM E-84tdspipe-and-tank
Pittsburgh CorningPittsburgh Corning FOAMGLAS HLB 1600 Cellular Glass Tank and Vessel InsulationABSORPTION OF MOISTURE ASTM C240 < 0.2% by Vol. THERMAL EXPANSION ASTM E228 "75 to 575 °F , 5.0 x 10^{-6} / °F -274 to 75 °F , 3.7 x 10^{-6} / °F". COMBUSTIBILITY ASTM E136 Noncombustible. COMPRESSIVE STRENGTH ASTM C165 / ASTM C240 / ASTM C552 LSL_{lot avg} = 232 lb / in^{2}, LSL_{ind} =160 lb / in^{2} CORROSION, ASTM C871 Acceptable for use with stainless steel. WATER SOLUBLE ASTM C692 Pass. IONS AND PH ASTM C1617 < DI Water. DENSITY (+/-15%) ASTM C303 10 lb / ft^{3}. FLEXURAL STRENGTH ASTM C203 / ASTM C240 LSL = 69 lb / in^{2}. MODULUS OF ELASTICITY ASTM C623 2.4 x 10^{5} lb / in^{2}. SERVICE TEMPERATURE "Without Load -450 to 900 °F With Load -450 to 752 °F". SPECIFIC HEAT ASTM E1461 0.18 BTU / lb·°F @ 77°F. SURFACE BURNING CHARACTERISTICS ASTM E84 Flame Spread Index 0 / Smoke Development Index 0. WATER VAPOR PERMEABILITY ASTM E96 Wet Cup 0.00 perm·inch. FOAMGLAS® Insulation can be certified to conform to the requirements of: • ASTM C552 “Standard Specification for Cellular Glass Thermal Insulation” (Grade 16) • I-QC-HLB / ISO 3951 • Military Specification MIL-DLT-24244D (SH), with Special Corrosion and Chloride Requirement” • Nuclear Regulatory Guide 1.36, ASTM C795, C692, C871 • Flame Spread Index 0, Smoke Developed Index 0 (UL 723, ASTM E 84), UL R2844; also classified by UL of Canada • UL 1709, Rapid Rise Fire Tests of Protection Materials for Structural Steel.ASTM C552, ASTM C795, ASTM C692, ASTM C871, ASTM E84, ASTM C 552, ASTM C 795, ASTM C 692, ASTM C 871, ASTM E 84, ASTM C-552, ASTM C-795, ASTM C-692, ASTM C-871, ASTM E-84sdspipe-and-tank
Pittsburgh CorningPittsburgh Corning FOAMGLAS HLB 2400 Cellular Glass Tank and Vessel InsulationABSORPTION OF MOISTURE ASTM C240 < 0.2% by Vol. THERMAL EXPANSION ASTM E228 "75 to 575 °F , 5.0 x 10^{-6} / °F -274 to 75 °F , 3.7 x 10^{-6} / °F". COMBUSTIBILITY ASTM E136 Noncombustible. COMPRESSIVE STRENGTH ASTM C165 / ASTM C240 / ASTM C552 LSL_{lot avg} = 348 lb / in^{2}, LSL_{ind} =240 lb / in^{2} CORROSION, ASTM C871 Acceptable for use with stainless steel. WATER SOLUBLE ASTM C692 Pass. IONS AND PH ASTM C1617 < DI Water. DENSITY (+/-15%) ASTM C303 12.5 lb / ft^{3}. FLEXURAL STRENGTH ASTM C203 / ASTM C240 LSL = 91 lb / in^{2}. MODULUS OF ELASTICITY ASTM C623 3.1 x 10^{5} lb / in^{2}. SERVICE TEMPERATURE "Without Load -450 to 900 °F With Load -450 to 752 °F". SPECIFIC HEAT ASTM E1461 0.18 BTU / lb·°F @ 77°F. SURFACE BURNING CHARACTERISTICS ASTM E84 Flame Spread Index 0 / Smoke Development Index 0. WATER VAPOR PERMEABILITY ASTM E96 Wet Cup 0.00 perm·inch. FOAMGLAS® Insulation can be certified to conform to the requirements of: • ASTM C552 “Standard Specification for Cellular Glass Thermal Insulation” (Grade 24) • I-QC-HLB / ISO 3951 • Military Specification MIL-DLT-24244D (SH), with Special Corrosion and Chloride Requirement” • Nuclear Regulatory Guide 1.36, ASTM C795, C692, C871 • Flame Spread Index 0, Smoke Developed Index 0 (UL 723, ASTM E 84), UL R2844; also classified by UL of Canada • UL 1709, Rapid Rise Fire Tests of Protection Materials for Structural Steel.ASTM C552, ASTM C795, ASTM C692, ASTM C871, ASTM E84, ASTM C 552, ASTM C 795, ASTM C 692, ASTM C 871, ASTM E 84, ASTM C-552, ASTM C-795, ASTM C-692, ASTM C-871, ASTM E-84sdspipe-and-tank
Pittsburgh CorningPittsburgh Corning FOAMGLAS HLB 2400 Cellular Glass Tank and Vessel InsulationABSORPTION OF MOISTURE ASTM C240 < 0.2% by Vol. THERMAL EXPANSION ASTM E228 "75 to 575 °F , 5.0 x 10^{-6} / °F -274 to 75 °F , 3.7 x 10^{-6} / °F". COMBUSTIBILITY ASTM E136 Noncombustible. COMPRESSIVE STRENGTH ASTM C165 / ASTM C240 / ASTM C552 LSL_{lot avg} = 348 lb / in^{2}, LSL_{ind} =240 lb / in^{2} CORROSION, ASTM C871 Acceptable for use with stainless steel. WATER SOLUBLE ASTM C692 Pass. IONS AND PH ASTM C1617 < DI Water. DENSITY (+/-15%) ASTM C303 12.5 lb / ft^{3}. FLEXURAL STRENGTH ASTM C203 / ASTM C240 LSL = 91 lb / in^{2}. MODULUS OF ELASTICITY ASTM C623 3.1 x 10^{5} lb / in^{2}. SERVICE TEMPERATURE "Without Load -450 to 900 °F With Load -450 to 752 °F". SPECIFIC HEAT ASTM E1461 0.18 BTU / lb·°F @ 77°F. SURFACE BURNING CHARACTERISTICS ASTM E84 Flame Spread Index 0 / Smoke Development Index 0. WATER VAPOR PERMEABILITY ASTM E96 Wet Cup 0.00 perm·inch. FOAMGLAS® Insulation can be certified to conform to the requirements of: • ASTM C552 “Standard Specification for Cellular Glass Thermal Insulation” (Grade 24) • I-QC-HLB / ISO 3951 • Military Specification MIL-DLT-24244D (SH), with Special Corrosion and Chloride Requirement” • Nuclear Regulatory Guide 1.36, ASTM C795, C692, C871 • Flame Spread Index 0, Smoke Developed Index 0 (UL 723, ASTM E 84), UL R2844; also classified by UL of Canada • UL 1709, Rapid Rise Fire Tests of Protection Materials for Structural Steel.ASTM C552, ASTM C795, ASTM C692, ASTM C871, ASTM E84, ASTM C 552, ASTM C 795, ASTM C 692, ASTM C 871, ASTM E 84, ASTM C-552, ASTM C-795, ASTM C-692, ASTM C-871, ASTM E-84tdspipe-and-tank
Pittsburgh CorningPittsburgh Corning FOAMGLAS HLB 800 Cellular Glass Tank and Vessel InsulationABSORPTION OF MOISTURE ASTM C240 < 0.2% by Vol. THERMAL EXPANSION ASTM E228 "75 to 575 °F , 5.0 x 10^{-6} / °F -274 to 75 °F , 3.7 x 10^{-6} / °F". COMBUSTIBILITY ASTM E136 Noncombustible. COMPRESSIVE STRENGTH ASTM C165 / ASTM C240 / ASTM C552 LSL_{lot avg} = 116 lb / in^{2}, LSL_{ind} =80 lb / in^{2} CORROSION, ASTM C871 Acceptable for use with stainless steel. WATER SOLUBLE ASTM C692 Pass. IONS AND PH ASTM C1617 < DI Water. DENSITY (+/-15%) ASTM C303 7.5 lb / ft^{3}. FLEXURAL STRENGTH ASTM C203 / ASTM C240 LSL = 45 lb / in^{2}. MODULUS OF ELASTICITY ASTM C623 1.6 x 10^{5} lb / in^{2}. SERVICE TEMPERATURE "Without Load -450 to 900 °F With Load -450 to 752 °F". SPECIFIC HEAT ASTM E1461 0.18 BTU / lb·°F @ 77°F. SURFACE BURNING CHARACTERISTICS ASTM E84 Flame Spread Index 0 / Smoke Development Index 0. WATER VAPOR PERMEABILITY ASTM E96 Wet Cup 0.00 perm·inch. FOAMGLAS® Insulation can be certified to conform to the requirements of: • ASTM C552 “Standard Specification for Cellular Glass Thermal Insulation” (Grade 8) • I-QC-HLB / ISO 3951 • Military Specification MIL-DLT-24244D (SH), with Special Corrosion and Chloride Requirement” • Nuclear Regulatory Guide 1.36, ASTM C795, C692, C871 • Flame Spread Index 0, Smoke Developed Index 0 (UL 723, ASTM E 84), UL R2844; also classified by UL of Canada • UL 1709, Rapid Rise Fire Tests of Protection Materials for Structural Steel.ASTM C552, ASTM C795, ASTM C692, ASTM C871, ASTM E84, ASTM C 552, ASTM C 795, ASTM C 692, ASTM C 871, ASTM E 84, ASTM C-552, ASTM C-795, ASTM C-692, ASTM C-871, ASTM E-84tdspipe-and-tank
Pittsburgh CorningPittsburgh Corning FOAMGLAS HLB 800 Cellular Glass Tank and Vessel InsulationABSORPTION OF MOISTURE ASTM C240 < 0.2% by Vol. THERMAL EXPANSION ASTM E228 "75 to 575 °F , 5.0 x 10^{-6} / °F -274 to 75 °F , 3.7 x 10^{-6} / °F". COMBUSTIBILITY ASTM E136 Noncombustible. COMPRESSIVE STRENGTH ASTM C165 / ASTM C240 / ASTM C552 LSL_{lot avg} = 116 lb / in^{2}, LSL_{ind} =80 lb / in^{2} CORROSION, ASTM C871 Acceptable for use with stainless steel. WATER SOLUBLE ASTM C692 Pass. IONS AND PH ASTM C1617 < DI Water. DENSITY (+/-15%) ASTM C303 7.5 lb / ft^{3}. FLEXURAL STRENGTH ASTM C203 / ASTM C240 LSL = 45 lb / in^{2}. MODULUS OF ELASTICITY ASTM C623 1.6 x 10^{5} lb / in^{2}. SERVICE TEMPERATURE "Without Load -450 to 900 °F With Load -450 to 752 °F". SPECIFIC HEAT ASTM E1461 0.18 BTU / lb·°F @ 77°F. SURFACE BURNING CHARACTERISTICS ASTM E84 Flame Spread Index 0 / Smoke Development Index 0. WATER VAPOR PERMEABILITY ASTM E96 Wet Cup 0.00 perm·inch. FOAMGLAS® Insulation can be certified to conform to the requirements of: • ASTM C552 “Standard Specification for Cellular Glass Thermal Insulation” (Grade 8) • I-QC-HLB / ISO 3951 • Military Specification MIL-DLT-24244D (SH), with Special Corrosion and Chloride Requirement” • Nuclear Regulatory Guide 1.36, ASTM C795, C692, C871 • Flame Spread Index 0, Smoke Developed Index 0 (UL 723, ASTM E 84), UL R2844; also classified by UL of Canada • UL 1709, Rapid Rise Fire Tests of Protection Materials for Structural Steel.ASTM C552, ASTM C795, ASTM C692, ASTM C871, ASTM E84, ASTM C 552, ASTM C 795, ASTM C 692, ASTM C 871, ASTM E 84, ASTM C-552, ASTM C-795, ASTM C-692, ASTM C-871, ASTM E-84sdspipe-and-tank
Pittsburgh CorningPittsburgh Corning Foamglas One Pipe InsulationDENSITY, NOMINAL: ASTM C303 7.3 lbs. / ft3. ABSORPTION OF MOISTURE: ASTM C240 < 0.2% by Vol. WATER VAPOR PERMEABILITY: ASTM E96 0.00 perm-inch. CHEMICAL RESISTANCE: Impervious to common acids and their fumes. COMBUSTIBILITY & REACTION TO FIRE: ASTM E136 ASTM E84 Non-Combustible Flame Spread Index 0 Smoke Development Index 0. CORROSION, WATER SOLUABLE IONS AND PH: ASTM C871 ASTM C692 ASTM C1617 Acceptable for use with Stainless Steel Pass (0 Coupon Cracked) < DI Water. COMPRESSIVE STRENGTH, BLOCK AVG: ASTM C165 ASTM C240 ASTM C552 90 lbs / in2. DIMENSIONAL STABILITY: Excellent – does not shrink or swell. FLEXURAL STRENGTH, BLOCK AVG: ASTM C203 ASTM C240 480 KPa 70 lbs / in2. HYGROSCOPICITY: No increase in weight at 90% relative humidity. COEFFICIENT OF LINEAR THERMAL EXPANSION, AVG: ASTM E228 75 to 575F. 5.0 x 10^-6/F. -274 to 75F. 3.7 x 10^-6/F. SERVICE TEMPERATURE: -450 to 900F. MODULUS OF ELASTICITY, APPROXIMATE: ASTM C623 1.3 x 10^5 Lbs-in^-2. SPECIFIC HEAT: ASTM E1461 0.18 BTU / lb*F @ 77°F. THERMAL DIFFUSIVITY: ASTM E1461 0.016 ft^2/ hr. x ASTM C552 “Specification for Cellular Glass Thermal Insulation” x ASTM C1639 “Standard Specification for Fabrication of Cellular Glass Piping and Tubing Insulation” x Military Specification MIL-DLT-24244D (SH), with Special Corrosion and Chloride Requirement” x Nuclear Regulatory Guide 1.36, ASTM C795, C692, C871 x Flame Spread Index 0, Smoke Developed Index 0 (UL 723, ASTM E 84), UL R2844; also classified by UL of Canada x ISO 9001: 2008 x UL 1709, Rapid Rise Fire Tests of Protection Materials for Structural Steel x UL Through Penetration Fire Stop Approved Systems UL1479/ASTM E814,ASTM C552, ASTM C1639, ASTM C795, ASTM C692, ASTM C871, ASTM E84, ASTM E814, ASTM C 552, ASTM C 1639, ASTM C 795, ASTM C 692, ASTM C 871, ASTM E 84, ASTM E 814, ASTM C-552, ASTM C-1639, ASTM C-795, ASTM C-692, ASTM C-871, ASTM E-84, ASTM E-814tdspipe-insulation
Pittsburgh CorningPittsburgh Corning Foamglas One Pipe InsulationDENSITY, NOMINAL: ASTM C303 7.3 lbs. / ft3. ABSORPTION OF MOISTURE: ASTM C240 < 0.2% by Vol. WATER VAPOR PERMEABILITY: ASTM E96 0.00 perm-inch. CHEMICAL RESISTANCE: Impervious to common acids and their fumes. COMBUSTIBILITY & REACTION TO FIRE: ASTM E136 ASTM E84 Non-Combustible Flame Spread Index 0 Smoke Development Index 0. CORROSION, WATER SOLUABLE IONS AND PH: ASTM C871 ASTM C692 ASTM C1617 Acceptable for use with Stainless Steel Pass (0 Coupon Cracked) < DI Water. COMPRESSIVE STRENGTH, BLOCK AVG: ASTM C165 ASTM C240 ASTM C552 90 lbs / in2. DIMENSIONAL STABILITY: Excellent – does not shrink or swell. FLEXURAL STRENGTH, BLOCK AVG: ASTM C203 ASTM C240 480 KPa 70 lbs / in2. HYGROSCOPICITY: No increase in weight at 90% relative humidity. COEFFICIENT OF LINEAR THERMAL EXPANSION, AVG: ASTM E228 75 to 575F. 5.0 x 10^-6/F. -274 to 75F. 3.7 x 10^-6/F. SERVICE TEMPERATURE: -450 to 900F. MODULUS OF ELASTICITY, APPROXIMATE: ASTM C623 1.3 x 10^5 Lbs-in^-2. SPECIFIC HEAT: ASTM E1461 0.18 BTU / lb*F @ 77°F. THERMAL DIFFUSIVITY: ASTM E1461 0.016 ft^2/ hr. x ASTM C552 “Specification for Cellular Glass Thermal Insulation” x ASTM C1639 “Standard Specification for Fabrication of Cellular Glass Piping and Tubing Insulation” x Military Specification MIL-DLT-24244D (SH), with Special Corrosion and Chloride Requirement” x Nuclear Regulatory Guide 1.36, ASTM C795, C692, C871 x Flame Spread Index 0, Smoke Developed Index 0 (UL 723, ASTM E 84), UL R2844; also classified by UL of Canada x ISO 9001: 2008 x UL 1709, Rapid Rise Fire Tests of Protection Materials for Structural Steel x UL Through Penetration Fire Stop Approved Systems UL1479/ASTM E814,ASTM C552, ASTM C1639, ASTM C795, ASTM C692, ASTM C871, ASTM E84, ASTM E814, ASTM C 552, ASTM C 1639, ASTM C 795, ASTM C 692, ASTM C 871, ASTM E 84, ASTM E 814, ASTM C-552, ASTM C-1639, ASTM C-795, ASTM C-692, ASTM C-871, ASTM E-84, ASTM E-814sdspipe-insulation
PolyguardPolyguard ALUMAGUARD Flexible Weather-Proofing JacketProduct Thickness Micrometer 54 mils, (without liner) 57 mils (Cool Wrap). Product Weight Scale 0.3 lbs/sf. Water Vapor Transmission (grains/hr-ft²) ASTM E96 0.00. Permeance (US Perms) ASTM E96 0.00. Peel Adhesion (to primed steel) ASTM D1000 >12 lbs/in. Elongation at Break ASTM D882 182%. Low Temperature Pliability ASTM D146 No Cracks@-15ºF. Tensile Strength (Film only)(MD) ASTM D882 43 lbs/in, (XD) 51 lbs/in. Puncture Resistance (Film Only) ASTM D1000 15 lbs/in. Mold Resistance ASTM C1338 Pass. Upper Temperature Limit LAB 160ºF. Emissivity ASTM C1371 .030.ASTM E96, ASTM D1000, ASTM D882, ASTM D146, ASTM D882, ASTM D774, ASTM C1338, ASTM C1371, ASTM E 96, ASTM D 1000, ASTM D 882, ASTM D 146, ASTM D 882, ASTM D 774, ASTM C 1338, ASTM C 1371, ASTM E-96, ASTM D-1000, ASTM D-882, ASTM D-146, ASTM D-882, ASTM D-774, ASTM C-1338, ASTM C-1371tdscladding
PolyguardPolyguard ALUMAGUARD Flexible Weather-Proofing JacketProduct Thickness Micrometer 54 mils, (without liner) 57 mils (Cool Wrap). Product Weight Scale 0.3 lbs/sf. Water Vapor Transmission (grains/hr-ft²) ASTM E96 0.00. Permeance (US Perms) ASTM E96 0.00. Peel Adhesion (to primed steel) ASTM D1000 >12 lbs/in. Elongation at Break ASTM D882 182%. Low Temperature Pliability ASTM D146 No Cracks@-15ºF. Tensile Strength (Film only)(MD) ASTM D882 43 lbs/in, (XD) 51 lbs/in. Puncture Resistance (Film Only) ASTM D1000 15 lbs/in. Mold Resistance ASTM C1338 Pass. Upper Temperature Limit LAB 160ºF. Emissivity ASTM C1371 .030.ASTM E96, ASTM D1000, ASTM D882, ASTM D146, ASTM D882, ASTM D774, ASTM C1338, ASTM C1371, ASTM E 96, ASTM D 1000, ASTM D 882, ASTM D 146, ASTM D 882, ASTM D 774, ASTM C 1338, ASTM C 1371, ASTM E-96, ASTM D-1000, ASTM D-882, ASTM D-146, ASTM D-882, ASTM D-774, ASTM C-1338, ASTM C-1371sdscladding
ProtechglobalProTech Global GT1625HT FSK (Foil/Scrim/Kraft) Aluminum Foil TapeAdhesive Solvent Acrylic. PSTC-133 / ASTM D 3652 Product Thickness: 4.8 mil. PSTC-133 / ASTM D 3652 Total Thickness: 6.8 mil. PSTC-131 / ASTM D 3759 Elongation at Break: 1%. PSTC-6 / ASTM D 3121 Tack Rolling Ball: 6.0 in. PSTC-131 / ASTM D 3759 Tensile Strength: 27.3 lb/in. PSTC-101 / ASTM D 3330 Adhesion to Steel: 54 oz/in. ASTM E84 / UL723 Fire Rating: 25/50. Service Temperature: -22˚F to 176˚F. Application Temperature: 50˚F to 105˚F. ASTM D3652, ASTM D3652, ASTM D3759, ASTM D3759 ASTM E84, ASTM D3330, ASTM D3121, ASTM D 3652, ASTM D 3652, ASTM D 3759, ASTM D 3759 ASTM E 84, ASTM D 3330, ASTM D 3121, ASTM D-3652, ASTM D-3652, ASTM D-3759, ASTM D-3759 ASTM E-84, ASTM D-3330, ASTM D-3121tdstapes
ProtechglobalProTech Global GT1625HT FSK (Foil/Scrim/Kraft) Aluminum Foil TapeAdhesive Solvent Acrylic. PSTC-133 / ASTM D 3652 Product Thickness: 4.8 mil. PSTC-133 / ASTM D 3652 Total Thickness: 6.8 mil. PSTC-131 / ASTM D 3759 Elongation at Break: 1%. PSTC-6 / ASTM D 3121 Tack Rolling Ball: 6.0 in. PSTC-131 / ASTM D 3759 Tensile Strength: 27.3 lb/in. PSTC-101 / ASTM D 3330 Adhesion to Steel: 54 oz/in. ASTM E84 / UL723 Fire Rating: 25/50. Service Temperature: -22˚F to 176˚F. Application Temperature: 50˚F to 105˚F. ASTM D3652, ASTM D3652, ASTM D3759, ASTM D3759 ASTM E84, ASTM D3330, ASTM D3121, ASTM D 3652, ASTM D 3652, ASTM D 3759, ASTM D 3759 ASTM E 84, ASTM D 3330, ASTM D 3121, ASTM D-3652, ASTM D-3652, ASTM D-3759, ASTM D-3759 ASTM E-84, ASTM D-3330, ASTM D-3121sdstapes
ProtechglobalProTech Global GT50HT High Tack Cold Weather Aluminum Foil TapeAdhesive Solvent Acrylic. PSTC-133 / ASTM D 3652 Product Thickness: 2 mil. PSTC-133 / ASTM D 3652 Total Thickness: 3.5 mil. PSTC-131 / ASTM D 3759 Elongation at Break: 3%. PSTC-6 / ASTM D 3121 Tack Rolling Ball: 2 in. PSTC-131 / ASTM D 3759 Tensile Strength: 10.2 lb/in. PSTC-101 / ASTM D 3330 Adhesion to Steel: 54 oz/in. ASTM E84 / UL723 Fire Rating: 25/50. Service Temperature: -31˚F to 248˚F. Application Temperature: -4˚F to 105˚F. ASTM D3652, ASTM D3652, ASTM D3759, ASTM D3759 ASTM E84, ASTM D3330, ASTM D3121, ASTM D 3652, ASTM D 3652, ASTM D 3759, ASTM D 3759 ASTM E 84, ASTM D 3330, ASTM D 3121, ASTM D-3652, ASTM D-3652, ASTM D-3759, ASTM D-3759 ASTM E-84, ASTM D-3330, ASTM D-3121tdstapes
ProtechglobalProTech Global GT50HT High Tack Cold Weather Aluminum Foil TapeAdhesive Solvent Acrylic. PSTC-133 / ASTM D 3652 Product Thickness: 2 mil. PSTC-133 / ASTM D 3652 Total Thickness: 3.5 mil. PSTC-131 / ASTM D 3759 Elongation at Break: 3%. PSTC-6 / ASTM D 3121 Tack Rolling Ball: 2 in. PSTC-131 / ASTM D 3759 Tensile Strength: 10.2 lb/in. PSTC-101 / ASTM D 3330 Adhesion to Steel: 54 oz/in. ASTM E84 / UL723 Fire Rating: 25/50. Service Temperature: -31˚F to 248˚F. Application Temperature: -4˚F to 105˚F. ASTM D3652, ASTM D3652, ASTM D3759, ASTM D3759 ASTM E84, ASTM D3330, ASTM D3121, ASTM D 3652, ASTM D 3652, ASTM D 3759, ASTM D 3759 ASTM E 84, ASTM D 3330, ASTM D 3121, ASTM D-3652, ASTM D-3652, ASTM D-3759, ASTM D-3759 ASTM E-84, ASTM D-3330, ASTM D-3121sdstapes
ProtechglobalProTech Global PROCLAD150 Cladding SystemProduct Thickness: 150 microns. EN 527-3 Tensile Strength: >200 newtons. EN 527-3 Elongation: >60%. ASTM F1249 ISO 15106-2 Water Permeability: 0.00 g/m2/d. DIN EN 14477 Puncture Resistance: >100 newtons. ASTM G 26A ISO 4892-2 UV Testing: 10 years plus. ASTM E84 / UL723 Fire Rating: 15/35. Service Temperature: -40˚F to +284˚F. Application Temperature: -22˚F to +266˚F.ASTM F1249, ASTM G26A, ASTM E84, ASTM F 1249, ASTM G 26A, ASTM E 84, ASTM F-1249, ASTM G-26A, ASTM E-84tdscladding
ProtechglobalProTech Global PROCLAD150 Cladding SystemProduct Thickness: 150 microns. EN 527-3 Tensile Strength: >200 newtons. EN 527-3 Elongation: >60%. ASTM F1249 ISO 15106-2 Water Permeability: 0.00 g/m2/d. DIN EN 14477 Puncture Resistance: >100 newtons. ASTM G 26A ISO 4892-2 UV Testing: 10 years plus. ASTM E84 / UL723 Fire Rating: 15/35. Service Temperature: -40˚F to +284˚F. Application Temperature: -22˚F to +266˚F.ASTM F1249, ASTM G26A, ASTM E84, ASTM F 1249, ASTM G 26A, ASTM E 84, ASTM F-1249, ASTM G-26A, ASTM E-84sdscladding
ProtoProto Cut & Curl JacketingMade of Lo-Smoke PVC with a 25/50 Flame and Smoke Rating ASTM E-84 Up to .035” Thk. Specific Gravity (ASTM D-792): 1.41. Tensile Modulus PSI(ASTM D-638): 361,000 (25,380 kg/cm^2). Tensile Strength, PSI (ASTM D-638): 6,011. Flexural Strength, PSI (ASTM D-790): 9,396. Izod Impact (1/4”) ft. lb/in (ASTM D-256): 3.7. Heat Deflection Temp. (ASTM D-648): 157F (70C). VICAT Softening Temp. (ASTM D-1525): 198F (92C). Water Vapor Transmission (ASTM E96-95): 70F & 50% Relative Humidity: .015” thick = .58 - .020” thick = .047 – 0.30” thick = .027. Puncture Resistance (ASTM D 781): 006” thick = 178 Beach Units - .015 thick = 221 Beach Units.ASTM E84, ASTM D792, ASTM D638, ASTM D790, ASTM D256, ASTM D648, ASTM D1525, ASTM E96, ASTM E95, ASTM E 84, ASTM D 792, ASTM D 638, ASTM D 790, ASTM D 256, ASTM D 648, ASTM D 1525, ASTM E 96, ASTM E 95, ASTM E-84, ASTM D-792, ASTM D-638, ASTM D-790, ASTM D-256, ASTM D-648, ASTM D-1525, ASTM E-96, ASTM E-95tdsjacketing
ProtoProto Cut & Curl JacketingMade of Lo-Smoke PVC with a 25/50 Flame and Smoke Rating ASTM E-84 Up to .035” Thk. Specific Gravity (ASTM D-792): 1.41. Tensile Modulus PSI(ASTM D-638): 361,000 (25,380 kg/cm^2). Tensile Strength, PSI (ASTM D-638): 6,011. Flexural Strength, PSI (ASTM D-790): 9,396. Izod Impact (1/4”) ft. lb/in (ASTM D-256): 3.7. Heat Deflection Temp. (ASTM D-648): 157F (70C). VICAT Softening Temp. (ASTM D-1525): 198F (92C). Water Vapor Transmission (ASTM E96-95): 70F & 50% Relative Humidity: .015” thick = .58 - .020” thick = .047 – 0.30” thick = .027. Puncture Resistance (ASTM D 781): 006” thick = 178 Beach Units - .015 thick = 221 Beach Units.ASTM E84, ASTM D792, ASTM D638, ASTM D790, ASTM D256, ASTM D648, ASTM D1525, ASTM E96, ASTM E95, ASTM E 84, ASTM D 792, ASTM D 638, ASTM D 790, ASTM D 256, ASTM D 648, ASTM D 1525, ASTM E 96, ASTM E 95, ASTM E-84, ASTM D-792, ASTM D-638, ASTM D-790, ASTM D-256, ASTM D-648, ASTM D-1525, ASTM E-96, ASTM E-95sdsjacketing
ProtoProto PVC FittingsAll Proto Fittings are made of Lo-Smoke PVC with a 25/50 Flame and Smoke Rating ASTM E-84 Up to .035” Thk. Specific Gravity (ASTM D-792): 1.41. Tensile Modulus PSI(ASTM D-638): 361,000 (25,380 kg/cm^2). Tensile Strength, PSI (ASTM D-638): 6,011. Flexural Strength, PSI (ASTM D-790): 9,396. Izod Impact (1/4”) ft. lb/in (ASTM D-256): 3.7. Heat Deflection Temp. (ASTM D-648): 157F (70C). VICAT Softening Temp. (ASTM D-1525): 198F (92C). Water Vapor Transmission (ASTM E96-95): 70F & 50% Relative Humidity: .015” thick = .58 - .020” thick = .047 – 0.30” thick = .027. Puncture Resistance (ASTM D 781): 006” thick = 178 Beach Units - .015 thick = 221 Beach Units.ASTM E84, ASTM D792, ASTM D638, ASTM D790 ASTM D256, ASTM D648, ASTM D1525, ASTM E96, ASTM E95, ASTM E 84, ASTM D 792, ASTM D 638, ASTM D 790 ASTM D 256, ASTM D 648, ASTM D 1525, ASTM E 96, ASTM E 95, ASTM E-84, ASTM D-792, ASTM D-638, ASTM D-790 ASTM D-256, ASTM D-648, ASTM D-1525, ASTM E-96, ASTM E-95tdsfittings
ProtoProto PVC FittingsAll Proto Fittings are made of Lo-Smoke PVC with a 25/50 Flame and Smoke Rating ASTM E-84 Up to .035” Thk. Specific Gravity (ASTM D-792): 1.41. Tensile Modulus PSI(ASTM D-638): 361,000 (25,380 kg/cm^2). Tensile Strength, PSI (ASTM D-638): 6,011. Flexural Strength, PSI (ASTM D-790): 9,396. Izod Impact (1/4”) ft. lb/in (ASTM D-256): 3.7. Heat Deflection Temp. (ASTM D-648): 157F (70C). VICAT Softening Temp. (ASTM D-1525): 198F (92C). Water Vapor Transmission (ASTM E96-95): 70F & 50% Relative Humidity: .015” thick = .58 - .020” thick = .047 – 0.30” thick = .027. Puncture Resistance (ASTM D 781): 006” thick = 178 Beach Units - .015 thick = 221 Beach Units.ASTM E84, ASTM D792, ASTM D638, ASTM D790 ASTM D256, ASTM D648, ASTM D1525, ASTM E96, ASTM E95, ASTM E 84, ASTM D 792, ASTM D 638, ASTM D 790 ASTM D 256, ASTM D 648, ASTM D 1525, ASTM E 96, ASTM E 95, ASTM E-84, ASTM D-792, ASTM D-638, ASTM D-790 ASTM D-256, ASTM D-648, ASTM D-1525, ASTM E-96, ASTM E-95sdsfittings
ProtoProto PVC Bulk RollsMade of Lo-Smoke PVC with a 25/50 Flame and Smoke Rating ASTM E-84 Up to .035” Thk. Specific Gravity (ASTM D-792): 1.41. Tensile Modulus PSI(ASTM D-638): 361,000 (25,380 kg/cm^2). Tensile Strength, PSI (ASTM D-638): 6,011. Flexural Strength, PSI (ASTM D-790): 9,396. Izod Impact (1/4”) ft. lb/in (ASTM D-256): 3.7. Heat Deflection Temp. (ASTM D-648): 157F (70C). VICAT Softening Temp. (ASTM D-1525): 198F (92C). Water Vapor Transmission (ASTM E96-95): 70F & 50% Relative Humidity: .015” thick = .58 - .020” thick = .047 – 0.30” thick = .027. Puncture Resistance (ASTM D 781): 006” thick = 178 Beach Units - .015 thick = 221 Beach Units.ASTM E84, ASTM D792, ASTM D638, ASTM D790, ASTM D256, ASTM D648, ASTM D1525, ASTM E96, ASTM E95, ASTM E 84, ASTM D 792, ASTM D 638, ASTM D 790, ASTM D 256, ASTM D 648, ASTM D 1525, ASTM E 96, ASTM E 95, ASTM E-84, ASTM D-792, ASTM D-638, ASTM D-790, ASTM D-256, ASTM D-648, ASTM D-1525, ASTM E-96, ASTM E-95sdsjacketing
ProtoProto PVC Bulk RollsMade of Lo-Smoke PVC with a 25/50 Flame and Smoke Rating ASTM E-84 Up to .035” Thk. Specific Gravity (ASTM D-792): 1.41. Tensile Modulus PSI(ASTM D-638): 361,000 (25,380 kg/cm^2). Tensile Strength, PSI (ASTM D-638): 6,011. Flexural Strength, PSI (ASTM D-790): 9,396. Izod Impact (1/4”) ft. lb/in (ASTM D-256): 3.7. Heat Deflection Temp. (ASTM D-648): 157F (70C). VICAT Softening Temp. (ASTM D-1525): 198F (92C). Water Vapor Transmission (ASTM E96-95): 70F & 50% Relative Humidity: .015” thick = .58 - .020” thick = .047 – 0.30” thick = .027. Puncture Resistance (ASTM D 781): 006” thick = 178 Beach Units - .015 thick = 221 Beach Units.ASTM E84, ASTM D792, ASTM D638, ASTM D790, ASTM D256, ASTM D648, ASTM D1525, ASTM E96, ASTM E95, ASTM E 84, ASTM D 792, ASTM D 638, ASTM D 790, ASTM D 256, ASTM D 648, ASTM D 1525, ASTM E 96, ASTM E 95, ASTM E-84, ASTM D-792, ASTM D-638, ASTM D-790, ASTM D-256, ASTM D-648, ASTM D-1525, ASTM E-96, ASTM E-95tdsjacketing
ProtoProto PVC Flat Sheet JacketingMade of Lo-Smoke PVC with a 25/50 Flame and Smoke Rating ASTM E-84 Up to .035” Thk. Specific Gravity (ASTM D-792): 1.41. Tensile Modulus PSI(ASTM D-638): 361,000 (25,380 kg/cm^2). Tensile Strength, PSI (ASTM D-638): 6,011. Flexural Strength, PSI (ASTM D-790): 9,396. Izod Impact (1/4”) ft. lb/in (ASTM D-256): 3.7. Heat Deflection Temp. (ASTM D-648): 157F (70C). VICAT Softening Temp. (ASTM D-1525): 198F (92C). Water Vapor Transmission (ASTM E96-95): 70F & 50% Relative Humidity: .015” thick = .58 - .020” thick = .047 – 0.30” thick = .027. Puncture Resistance (ASTM D 781): 006” thick = 178 Beach Units - .015 thick = 221 Beach Units.ASTM E84, ASTM D792, ASTM D638, ASTM D790, ASTM D256, ASTM D648, ASTM D1525, ASTM E96, ASTM E95, ASTM E 84, ASTM D 792, ASTM D 638, ASTM D 790, ASTM D 256, ASTM D 648, ASTM D 1525, ASTM E 96, ASTM E 95, ASTM E-84, ASTM D-792, ASTM D-638, ASTM D-790, ASTM D-256, ASTM D-648, ASTM D-1525, ASTM E-96, ASTM E-95tdsjacketing
ProtoProto PVC Flat Sheet JacketingMade of Lo-Smoke PVC with a 25/50 Flame and Smoke Rating ASTM E-84 Up to .035” Thk. Specific Gravity (ASTM D-792): 1.41. Tensile Modulus PSI(ASTM D-638): 361,000 (25,380 kg/cm^2). Tensile Strength, PSI (ASTM D-638): 6,011. Flexural Strength, PSI (ASTM D-790): 9,396. Izod Impact (1/4”) ft. lb/in (ASTM D-256): 3.7. Heat Deflection Temp. (ASTM D-648): 157F (70C). VICAT Softening Temp. (ASTM D-1525): 198F (92C). Water Vapor Transmission (ASTM E96-95): 70F & 50% Relative Humidity: .015” thick = .58 - .020” thick = .047 – 0.30” thick = .027. Puncture Resistance (ASTM D 781): 006” thick = 178 Beach Units - .015 thick = 221 Beach Units.ASTM E84, ASTM D792, ASTM D638, ASTM D790, ASTM D256, ASTM D648, ASTM D1525, ASTM E96, ASTM E95, ASTM E 84, ASTM D 792, ASTM D 638, ASTM D 790, ASTM D 256, ASTM D 648, ASTM D 1525, ASTM E 96, ASTM E 95, ASTM E-84, ASTM D-792, ASTM D-638, ASTM D-790, ASTM D-256, ASTM D-648, ASTM D-1525, ASTM E-96, ASTM E-95sdsjacketing
ProtoProto PVC Mechanical Grooved CoversAll Proto Fittings are made of Lo-Smoke PVC with a 25/50 Flame and Smoke Rating ASTM E-84 Up to .035” Thk. Specific Gravity (ASTM D-792): 1.41. Tensile Modulus PSI(ASTM D-638): 361,000 (25,380 kg/cm^2). Tensile Strength, PSI (ASTM D-638): 6,011. Flexural Strength, PSI (ASTM D-790): 9,396. Izod Impact (1/4”) ft. lb/in (ASTM D-256): 3.7. Heat Deflection Temp. (ASTM D-648): 157F (70C). VICAT Softening Temp. (ASTM D-1525): 198F (92C). Water Vapor Transmission (ASTM E96-95): 70F & 50% Relative Humidity: .015” thick = .58 - .020” thick = .047 – 0.30” thick = .027. Puncture Resistance (ASTM D 781): 006” thick = 178 Beach Units - .015 thick = 221 Beach Units.ASTM E84, ASTM D792, ASTM D638, ASTM D790, ASTM D256, ASTM D648, ASTM D1525, ASTM E96, ASTM E95, ASTM E 84, ASTM D 792, ASTM D 638, ASTM D 790, ASTM D 256, ASTM D 648, ASTM D 1525, ASTM E 96, ASTM E 95, ASTM E-84, ASTM D-792, ASTM D-638, ASTM D-790, ASTM D-256, ASTM D-648, ASTM D-1525, ASTM E-96, ASTM E-95tdsfittings
ProtoProto PVC Mechanical Grooved CoversAll Proto Fittings are made of Lo-Smoke PVC with a 25/50 Flame and Smoke Rating ASTM E-84 Up to .035” Thk. Specific Gravity (ASTM D-792): 1.41. Tensile Modulus PSI(ASTM D-638): 361,000 (25,380 kg/cm^2). Tensile Strength, PSI (ASTM D-638): 6,011. Flexural Strength, PSI (ASTM D-790): 9,396. Izod Impact (1/4”) ft. lb/in (ASTM D-256): 3.7. Heat Deflection Temp. (ASTM D-648): 157F (70C). VICAT Softening Temp. (ASTM D-1525): 198F (92C). Water Vapor Transmission (ASTM E96-95): 70F & 50% Relative Humidity: .015” thick = .58 - .020” thick = .047 – 0.30” thick = .027. Puncture Resistance (ASTM D 781): 006” thick = 178 Beach Units - .015 thick = 221 Beach Units.ASTM E84, ASTM D792, ASTM D638, ASTM D790, ASTM D256, ASTM D648, ASTM D1525, ASTM E96, ASTM E95, ASTM E 84, ASTM D 792, ASTM D 638, ASTM D 790, ASTM D 256, ASTM D 648, ASTM D 1525, ASTM E 96, ASTM E 95, ASTM E-84, ASTM D-792, ASTM D-638, ASTM D-790, ASTM D-256, ASTM D-648, ASTM D-1525, ASTM E-96, ASTM E-95sdsfittings
Aspen AerogelsPyrogel HPS Aerogel InsulationASTM C1728 Type III, Grade 1A Standard Specification for Flexible Aerogel Insulation Complies, ASTM C165 Compressive Resistance‡ ≥ 3 psi (20.7 kPa) @ 10% deformation, ASTM C356 Linear Shrinkage Under Soaking Heat <2% @ 650°C (1200°F), ASTM C411 Hot Surface Performance Pass, ASTM C447 Estimation of Maximum Use Temperature 650°C (1200°F), ASTM C795 Insulation for Use Over Austenitic Stainless Steel Pass, ASTM C1101/1101M Flexibility of Blanket Insulation Flexible, ASTM C1104/1104M Water Vapor Sorption ≤ 5% (by weight), ASTM C1338 Fungal Resistance of Insulation Materials No Growth, ASTM C1617 Corrosiveness to Steel Pass, ASTM C1763 Water Absorption by Immersion Pass, ASTM E84 Surface burning Characteristics Flame Spread Index ≤ 5 Smoke Developed Index ≤ 10.ASTM C1728, ASTM C165, ASTM C356, ASTM C411, ASTM C447, ASTM C795, ASTM C1101/1101M, ASTM C1104/1104M, ASTM C1338, ASTM C1617, ASTM C1763, ASTM E-84. ASTM C-1728, ASTM C-165, ASTM C-356, ASTM C-411, ASTM C-447, ASTM C-795, ASTM C-1101/1101M, ASTM C-1104/1104M, ASTM C-1338, ASTM C-1617, ASTM C-1763, ASTM E-84. ASTM C 1728, ASTM C 165, ASTM C 356, ASTM C 411, ASTM C 447, ASTM C 795, ASTM C 1101/1101M, ASTM C 1104/1104M, ASTM C 1338, ASTM C 1617, ASTM C 1763, ASTM E 84.tdsaerogel
Aspen AerogelsPyrogel HPS Aerogel InsulationASTM C1728 Type III, Grade 1A Standard Specification for Flexible Aerogel Insulation Complies, ASTM C165 Compressive Resistance‡ ≥ 3 psi (20.7 kPa) @ 10% deformation, ASTM C356 Linear Shrinkage Under Soaking Heat <2% @ 650°C (1200°F), ASTM C411 Hot Surface Performance Pass, ASTM C447 Estimation of Maximum Use Temperature 650°C (1200°F), ASTM C795 Insulation for Use Over Austenitic Stainless Steel Pass, ASTM C1101/1101M Flexibility of Blanket Insulation Flexible, ASTM C1104/1104M Water Vapor Sorption ≤ 5% (by weight), ASTM C1338 Fungal Resistance of Insulation Materials No Growth, ASTM C1617 Corrosiveness to Steel Pass, ASTM C1763 Water Absorption by Immersion Pass, ASTM E84 Surface burning Characteristics Flame Spread Index ≤ 5 Smoke Developed Index ≤ 10.ASTM C1728, ASTM C165, ASTM C356, ASTM C411, ASTM C447, ASTM C795, ASTM C1101/1101M, ASTM C1104/1104M, ASTM C1338, ASTM C1617, ASTM C1763, ASTM E-84. ASTM C-1728, ASTM C-165, ASTM C-356, ASTM C-411, ASTM C-447, ASTM C-795, ASTM C-1101/1101M, ASTM C-1104/1104M, ASTM C-1338, ASTM C-1617, ASTM C-1763, ASTM E-84. ASTM C 1728, ASTM C 165, ASTM C 356, ASTM C 411, ASTM C 447, ASTM C 795, ASTM C 1101/1101M, ASTM C 1104/1104M, ASTM C 1338, ASTM C 1617, ASTM C 1763, ASTM E 84.sdsaerogel
Aspen AerogelsPyrogel XTE Aerogel InsulationASTM C165 Compressive Resistance: ≥ 3 psi (20.7 kPa) @ 10% deformation. ASTM C356 Linear Shrinkage Under Soaking Heat: < 2% @ 1200°F (650°C). ASTM C411 Hot Surface Performance: Pass. ASTM C447 Estimation of Maximum Use Temperature: 1200°F (650°C). ASTM C795 Insulation for Use Over Austenitic Stainless-Steel: Pass. ASTM C1101/1101M Flexibility of Blanket Insulation: Flexible. ASTM C1104/1104M Water Vapor Sorption: ≤ 5% (by weight). ASTM C1338 Fungal Resistance of Insulation Materials: Pass. ASTM C1617 Corrosiveness to Steel: Pass. ASTM C1763 Water Absorption by Immersion: PassASTM C1728, ASTM C165, ASTM C356, ASTM C411, ASTM C447, ASTM C795, ASTM C1101, ASTM C1104, ASTM C1338, ASTM C1617, ASTM C1763, ASTM E84, ASTM C 1728, ASTM C 165, ASTM C 356, ASTM C 411, ASTM C 447, ASTM C 795, ASTM C 1101, ASTM C 1104, ASTM C 1338, ASTM C 1617, ASTM C 1763, ASTM E 84, ASTM C-1728, ASTM C-165, ASTM C-356, ASTM C-411, ASTM C-447, ASTM C-795, ASTM C-1101, ASTM C-1104, ASTM C-1338, ASTM C-1617, ASTM C-1763, ASTM E-84tdsaerogel
Aspen AerogelsPyrogel XTE Aerogel InsulationASTM C165 Compressive Resistance: ≥ 3 psi (20.7 kPa) @ 10% deformation. ASTM C356 Linear Shrinkage Under Soaking Heat: < 2% @ 1200°F (650°C). ASTM C411 Hot Surface Performance: Pass. ASTM C447 Estimation of Maximum Use Temperature: 1200°F (650°C). ASTM C795 Insulation for Use Over Austenitic Stainless-Steel: Pass. ASTM C1101/1101M Flexibility of Blanket Insulation: Flexible. ASTM C1104/1104M Water Vapor Sorption: ≤ 5% (by weight). ASTM C1338 Fungal Resistance of Insulation Materials: Pass. ASTM C1617 Corrosiveness to Steel: Pass. ASTM C1763 Water Absorption by Immersion: PassASTM C1728, ASTM C165, ASTM C356, ASTM C411, ASTM C447, ASTM C795, ASTM C1101, ASTM C1104, ASTM C1338, ASTM C1617, ASTM C1763, ASTM E84, ASTM C 1728, ASTM C 165, ASTM C 356, ASTM C 411, ASTM C 447, ASTM C 795, ASTM C 1101, ASTM C 1104, ASTM C 1338, ASTM C 1617, ASTM C 1763, ASTM E 84, ASTM C-1728, ASTM C-165, ASTM C-356, ASTM C-411, ASTM C-447, ASTM C-795, ASTM C-1101, ASTM C-1104, ASTM C-1338, ASTM C-1617, ASTM C-1763, ASTM E-84sdsaerogel
Aspen AerogelsPyrogel XTF Aerogel Blanket InsulationASTM C1651 Compressive Resistance ≥ 3 psi (20.7 kPa) @ 10% deformation, ASTM C411 Hot Surface Performance Pass2, ASTM C447 Estimation of Maximum Use Temperature 650°C (1200°F), ASTM C795 Insulation for Use Over Austenitic Stainless Steel Pass, ASTM C1101/1101M Flexibility of Blanket Insulation Flexible, ASTM C1104/1104M Water Vapor Sorption ≤ 5% (by weight), ASTM C1338 Fungal Resistance of Insulation Materials No Growth, ASTM C1617 Corrosiveness to Steel Pass2, ASTM C1763 Water Absorption by Immersion Pass2, ASTM E84 Surface Burning Characteristics Flame Spread Index ≤ 5 Smoke Developed Index ≤ 10.ASTM C1651, ASTM C411, ASTM C447, ASTM C795, ASTM C1101/1101M, ASTM C1104/1104M, ASTM C1338, ASTM C1617, ASTM C1763, ASTM E84. ASTM C-1651, ASTM C-411, ASTM C-447, ASTM C-795, ASTM C-1101/1101M, ASTM C-1104/1104M, ASTM C-1338, ASTM C-1617, ASTM C-1763, ASTM E-84. ASTM C 1651, ASTM C 411, ASTM C 447, ASTM C 795, ASTM C 1101/1101M, ASTM C 1104/1104M, ASTM C 1338, ASTM C 1617, ASTM C 1763, ASTM E 84.sdsaerogel
Aspen AerogelsPyrogel XTF Aerogel Blanket InsulationASTM C1651 Compressive Resistance ≥ 3 psi (20.7 kPa) @ 10% deformation, ASTM C411 Hot Surface Performance Pass2, ASTM C447 Estimation of Maximum Use Temperature 650°C (1200°F), ASTM C795 Insulation for Use Over Austenitic Stainless Steel Pass, ASTM C1101/1101M Flexibility of Blanket Insulation Flexible, ASTM C1104/1104M Water Vapor Sorption ≤ 5% (by weight), ASTM C1338 Fungal Resistance of Insulation Materials No Growth, ASTM C1617 Corrosiveness to Steel Pass2, ASTM C1763 Water Absorption by Immersion Pass2, ASTM E84 Surface Burning Characteristics Flame Spread Index ≤ 5 Smoke Developed Index ≤ 10.ASTM C1651, ASTM C411, ASTM C447, ASTM C795, ASTM C1101/1101M, ASTM C1104/1104M, ASTM C1338, ASTM C1617, ASTM C1763, ASTM E84. ASTM C-1651, ASTM C-411, ASTM C-447, ASTM C-795, ASTM C-1101/1101M, ASTM C-1104/1104M, ASTM C-1338, ASTM C-1617, ASTM C-1763, ASTM E-84. ASTM C 1651, ASTM C 411, ASTM C 447, ASTM C 795, ASTM C 1101/1101M, ASTM C 1104/1104M, ASTM C 1338, ASTM C 1617, ASTM C 1763, ASTM E 84.tdsaerogel
RockwoolROCKWOOL Cavityrock Insulation BoardASTM C612: Type IVB Compliant. ASTM E84 (UL 723): Flame spread index = 0; Smoke developed index = 0. CAN/ULC S102: Flame spread index = 0; Smoke developed index = 0 CAN/ULC S114: Determination of Non Combustibility of Building Materials - Non Combustible ASTM E136: Behaviour of materials at 750°C - Non Combustible ASTM C303: Density (thickness:1”, 1.5”): Monolithic Density of 5.3 lbs/ft³. Density (thickness: 2”): Monolithic Density of 4.4 lbs/ft³. Density (thickness ≥ 2.5”): Dual Density - 6.2 lbs/ft³ (100 kg/m³) outer layer and 4.1 lbs/ft³ (65 kg/m³) inner layer, ASTM C795: Stress Corrosion Cracking Tendency of Austenitic Stainless Steel - Passed ASTM C665: Corrosion of Steel - Passed ASTM C518 (C177): R-Value / inch @ 75 F: 4.3 hr.ft2 .F/Btu. ASTM C1104: Moisture Sorption - 0.03% by volume ASTM E96: Water Vapor Transmission, Desiccant Method - 1555ng/Pa.s.m2 (27 perm) ASTM C1338: Determination of Fungi Resistance - Passed ASTM C423.ASTM C612, ASTM E84, ASTM E136, ASTM C303, ASTM C795, ASTM C665, ASTM C518, ASTM C1104, ASTM E96, ASTM C1338, ASTM C423, ASTM C 612, ASTM E 84, ASTM E 136, ASTM C 303, ASTM C 795, ASTM C 665, ASTM C 518, ASTM C 1104, ASTM E 96, ASTM C 1338, ASTM C 423, ASTM C-612, ASTM E-84, ASTM E-136, ASTM C-303, ASTM C-795, ASTM C-665, ASTM C-518, ASTM C-1104, ASTM E-96, ASTM C-1338, ASTM C-423tdsmineral-wool-commercial
RockwoolROCKWOOL Cavityrock Insulation BoardASTM C612: Type IVB Compliant. ASTM E84 (UL 723): Flame spread index = 0; Smoke developed index = 0. CAN/ULC S102: Flame spread index = 0; Smoke developed index = 0 CAN/ULC S114: Determination of Non Combustibility of Building Materials - Non Combustible ASTM E136: Behaviour of materials at 750°C - Non Combustible ASTM C303: Density (thickness:1”, 1.5”): Monolithic Density of 5.3 lbs/ft³. Density (thickness: 2”): Monolithic Density of 4.4 lbs/ft³. Density (thickness ≥ 2.5”): Dual Density - 6.2 lbs/ft³ (100 kg/m³) outer layer and 4.1 lbs/ft³ (65 kg/m³) inner layer, ASTM C795: Stress Corrosion Cracking Tendency of Austenitic Stainless Steel - Passed ASTM C665: Corrosion of Steel - Passed ASTM C518 (C177): R-Value / inch @ 75 F: 4.3 hr.ft2 .F/Btu. ASTM C1104: Moisture Sorption - 0.03% by volume ASTM E96: Water Vapor Transmission, Desiccant Method - 1555ng/Pa.s.m2 (27 perm) ASTM C1338: Determination of Fungi Resistance - Passed ASTM C423.ASTM C612, ASTM E84, ASTM E136, ASTM C303, ASTM C795, ASTM C665, ASTM C518, ASTM C1104, ASTM E96, ASTM C1338, ASTM C423, ASTM C 612, ASTM E 84, ASTM E 136, ASTM C 303, ASTM C 795, ASTM C 665, ASTM C 518, ASTM C 1104, ASTM E 96, ASTM C 1338, ASTM C 423, ASTM C-612, ASTM E-84, ASTM E-136, ASTM C-303, ASTM C-795, ASTM C-665, ASTM C-518, ASTM C-1104, ASTM E-96, ASTM C-1338, ASTM C-423sdsmineral-wool-commercial
RockwoolROCKWOOL Comfortboard 110 Continuous InsulationASTM C612: Type IVB Compliant. ASTM E84 (UL 723): Flame spread index = 0; Smoke developed index = 0. CAN/ULC S102: Flame spread index = 0; Smoke developed index = 0 CAN/ULC S114: Determination of Non Combustibility of Building Materials - Non Combustible ASTM C303:Actual Density - 11 lbs/ft³ (176 kg/m³), ASTM C795: Stress Corrosion Cracking Tendency of Austenitic Stainless Steel - Passed ASTM C665: Corrosion of Steel - Passed, Corrosion of Aluminum - Passed ASTM C518 (C177):R-Value / inch @ 75 F - 4 hr.ft2 .F/Btu. ASTM C1104: Moisture Sorption - 0.28% ASTM E96: Water Vapor Transmission, Desiccant Method - 2160ng/Pa.s.m2 (35 perm) ASTM C209: Water Absorption - 1.2% ASTM C1338:Determination of Fungi Resistance - Passed ASTM C165: 584psf (28kPa) @ 10% compression, 1566psf (75kPa) @ 25% compression ASTM C423.ASTM C612, ASTM E84, ASTM C303, ASTM C795, ASTM C665, ASTM C518, ASTM C1104, ASTM E96, ASTM C209, ASTM C1338, ASTM C165, ASTM C423, ASTM C 612, ASTM E 84, ASTM C 303, ASTM C 795, ASTM C 665, ASTM C 518, ASTM C 1104, ASTM E 96, ASTM C 209, ASTM C 1338, ASTM C 165, ASTM C 423, ASTM C-612, ASTM E-84, ASTM C-303, ASTM C-795, ASTM C-665, ASTM C-518, ASTM C-1104, ASTM E-96, ASTM C-209, ASTM C-1338, ASTM C-165, ASTM C-423tdsmineral-wool-commercial
RockwoolROCKWOOL Comfortboard 110 Continuous InsulationASTM C612: Type IVB Compliant. ASTM E84 (UL 723): Flame spread index = 0; Smoke developed index = 0. CAN/ULC S102: Flame spread index = 0; Smoke developed index = 0 CAN/ULC S114: Determination of Non Combustibility of Building Materials - Non Combustible ASTM C303:Actual Density - 11 lbs/ft³ (176 kg/m³), ASTM C795: Stress Corrosion Cracking Tendency of Austenitic Stainless Steel - Passed ASTM C665: Corrosion of Steel - Passed, Corrosion of Aluminum - Passed ASTM C518 (C177):R-Value / inch @ 75 F - 4 hr.ft2 .F/Btu. ASTM C1104: Moisture Sorption - 0.28% ASTM E96: Water Vapor Transmission, Desiccant Method - 2160ng/Pa.s.m2 (35 perm) ASTM C209: Water Absorption - 1.2% ASTM C1338:Determination of Fungi Resistance - Passed ASTM C165: 584psf (28kPa) @ 10% compression, 1566psf (75kPa) @ 25% compression ASTM C423.ASTM C612, ASTM E84, ASTM C303, ASTM C795, ASTM C665, ASTM C518, ASTM C1104, ASTM E96, ASTM C209, ASTM C1338, ASTM C165, ASTM C423, ASTM C 612, ASTM E 84, ASTM C 303, ASTM C 795, ASTM C 665, ASTM C 518, ASTM C 1104, ASTM E 96, ASTM C 209, ASTM C 1338, ASTM C 165, ASTM C 423, ASTM C-612, ASTM E-84, ASTM C-303, ASTM C-795, ASTM C-665, ASTM C-518, ASTM C-1104, ASTM E-96, ASTM C-209, ASTM C-1338, ASTM C-165, ASTM C-423sdsmineral-wool-commercial
RockwoolROCKWOOL Comfortboard 80 Continuous InsulationASTM C612: Type IVB Compliant. CAN/ULC S702: Mineral Fiber Thermal Insulation for buildings - Type 1 Compliant. ASTM E84 (UL 723): Flame spread index = 0; Smoke developed index = 0. CAN/ULC S102: Flame spread index = 0; Smoke developed index = 0 CAN/ULC S114: Determination of Non Combustibility of Building Materials - Non Combustible ASTM C303:Actual Density - 8 lbs/ft³ (128 kg/m³), ASTM C795: Stress Corrosion Cracking Tendency of Austenitic Stainless Steel - Passed ASTM C665: Corrosion of Steel - Passed ASTM C518 (C177):R-Value / inch @ 75 F - 4 hr.ft2 .F/Btu. ASTM C1104: Moisture Sorption - 0.05% ASTM E96: Water Vapor Transmission, Desiccant Method - 1768ng/Pa.s.m^{2} (31 perm) ASTM C1338:Determination of Fungi Resistance - Passed ASTM C165: 439psf (21kPa) @ 10% compression, 1065psf (50kPa) @ 25% compression ASTM C423.ASTM C612, ASTM E84, ASTM C303, ASTM C795, ASTM C665, ASTM C518, ASTM C1104, ASTM E96, ASTM C1338, ASTM C165, ASTM C423, ASTM C 612, ASTM E 84, ASTM C 303, ASTM C 795, ASTM C 665, ASTM C 518, ASTM C 1104, ASTM E 96, ASTM C 1338, ASTM C 165, ASTM C 423, ASTM C-612, ASTM E-84, ASTM C-303, ASTM C-795, ASTM C-665, ASTM C-518, ASTM C-1104, ASTM E-96, ASTM C-1338, ASTM C-165, ASTM C-423tdsmineral-wool-commercial
RockwoolROCKWOOL Comfortboard 80 Continuous InsulationASTM C612: Type IVB Compliant. CAN/ULC S702: Mineral Fiber Thermal Insulation for buildings - Type 1 Compliant. ASTM E84 (UL 723): Flame spread index = 0; Smoke developed index = 0. CAN/ULC S102: Flame spread index = 0; Smoke developed index = 0 CAN/ULC S114: Determination of Non Combustibility of Building Materials - Non Combustible ASTM C303:Actual Density - 8 lbs/ft³ (128 kg/m³), ASTM C795: Stress Corrosion Cracking Tendency of Austenitic Stainless Steel - Passed ASTM C665: Corrosion of Steel - Passed ASTM C518 (C177):R-Value / inch @ 75 F - 4 hr.ft2 .F/Btu. ASTM C1104: Moisture Sorption - 0.05% ASTM E96: Water Vapor Transmission, Desiccant Method - 1768ng/Pa.s.m^{2} (31 perm) ASTM C1338:Determination of Fungi Resistance - Passed ASTM C165: 439psf (21kPa) @ 10% compression, 1065psf (50kPa) @ 25% compression ASTM C423.ASTM C612, ASTM E84, ASTM C303, ASTM C795, ASTM C665, ASTM C518, ASTM C1104, ASTM E96, ASTM C1338, ASTM C165, ASTM C423, ASTM C 612, ASTM E 84, ASTM C 303, ASTM C 795, ASTM C 665, ASTM C 518, ASTM C 1104, ASTM E 96, ASTM C 1338, ASTM C 165, ASTM C 423, ASTM C-612, ASTM E-84, ASTM C-303, ASTM C-795, ASTM C-665, ASTM C-518, ASTM C-1104, ASTM E-96, ASTM C-1338, ASTM C-165, ASTM C-423sdsmineral-wool-commercial
RockwoolROCKWOOL Curtainrock Insulation BoardASTM C612: Type IVB Compliant. ASTM E84 (UL 723): Flame spread index = 0; Smoke developed index = 0. CAN/ULC S102: Flame spread index = 0; Smoke developed index = 0 CAN/ULC S114: Determination of Non Combustibility of Building Materials - Non Combustible ASTM C411: Hot Surface Performance = 1200F ASTM C303:Actual Density - 3.5 lbs/ft³ (56 kg/m³), ASTM C356: Linear Shrinkage - < 2 % @ 1200°F ASTM C795: Stress Corrosion Cracking Tendency of Austenitic Stainless Steel - Passed ASTM C665: Corrosion of Steel - Passed ASTM C518 (C177):R-Value / inch @ 75 F - 4.2 hr.ft2 .F/Btu. ASTM C1104: Moisture Sorption - 0.01% ASTM E96: Water Vapor Transmission, Desiccant Method - 1805ng/Pa.s.m2 (32 perm) ASTM C1338:Determination of Fungi Resistance - Passed ASTM C423.ASTM C612, ASTM E84, ASTM E136, ASTM C411, ASTM C303, ASTM C795, ASTM C665, ASTM C518, ASTM C1104, ASTM E96, ASTM C1338, ASTM C423, ASTM C 612, ASTM E 84, ASTM E 136, ASTM C 411, ASTM C 303, ASTM C 795, ASTM C 665, ASTM C 518, ASTM C 1104, ASTM E 96, ASTM C 1338, ASTM C 423, ASTM C-612, ASTM E-84, ASTM E-136, ASTM C-411, ASTM C-303, ASTM C-795, ASTM C-665, ASTM C-518, ASTM C-1104, ASTM E-96, ASTM C-1338, ASTM C-423tdsmineral-wool-commercial
RockwoolROCKWOOL Curtainrock Insulation BoardASTM C612: Type IVB Compliant. ASTM E84 (UL 723): Flame spread index = 0; Smoke developed index = 0. CAN/ULC S102: Flame spread index = 0; Smoke developed index = 0 CAN/ULC S114: Determination of Non Combustibility of Building Materials - Non Combustible ASTM C411: Hot Surface Performance = 1200F ASTM C303:Actual Density - 3.5 lbs/ft³ (56 kg/m³), ASTM C356: Linear Shrinkage - < 2 % @ 1200°F ASTM C795: Stress Corrosion Cracking Tendency of Austenitic Stainless Steel - Passed ASTM C665: Corrosion of Steel - Passed ASTM C518 (C177):R-Value / inch @ 75 F - 4.2 hr.ft2 .F/Btu. ASTM C1104: Moisture Sorption - 0.01% ASTM E96: Water Vapor Transmission, Desiccant Method - 1805ng/Pa.s.m2 (32 perm) ASTM C1338:Determination of Fungi Resistance - Passed ASTM C423.ASTM C612, ASTM E84, ASTM E136, ASTM C411, ASTM C303, ASTM C795, ASTM C665, ASTM C518, ASTM C1104, ASTM E96, ASTM C1338, ASTM C423, ASTM C 612, ASTM E 84, ASTM E 136, ASTM C 411, ASTM C 303, ASTM C 795, ASTM C 665, ASTM C 518, ASTM C 1104, ASTM E 96, ASTM C 1338, ASTM C 423, ASTM C-612, ASTM E-84, ASTM E-136, ASTM C-411, ASTM C-303, ASTM C-795, ASTM C-665, ASTM C-518, ASTM C-1104, ASTM E-96, ASTM C-1338, ASTM C-423sdsmineral-wool-commercial
RockwoolROCKWOOL ProRox MA 930 Wrap / Mat Mineral Wool InsulationASTM C177 ASTM C411: Hot Surface Performance: 1200°F- (650°C) ASTM E136 / CAN4 S114: Non-Combustible ASTM C356: Linear Shrinkage: ≤ 2 % at 1200°F- (650°C) ASTM E84 (UL 723): Flame spread index = 0 ; Smoke development index = 0 CAN/ULC S102: Flame spread index = 0 ; Smoke development index = 0 ASTM C303: Actual Density = 3.5 lb/ft³ - (56 kg/m³), Nominal Density = 4.0 lb/ft3 ASTM C692: Stress Corrosion Cracking Tendency of Austenitic Stainless Steel - Passed ASTM C665: Corrosion of Steel - Passed ASTM C795 / ASTM C871 ASTM C518(C177): R-Value / inch @ 75 F - 4.0 hr.ft2 .F/Btu ASTM C1104: Water Absorption/ Vapor Sorption - < 1% Weight ASTM C553: Complies with Type VIIASTM C177, ASTM C411, ASTM E136, ASTM C356, ASTM E84, ASTM C303, ASTM C692, ASTM C665, ASTM C795, ASTM C871, ASTM C518, ASTM C1104, ASTM C553, ASTM C 177, ASTM C 411, ASTM E 136, ASTM C 356, ASTM E 84, ASTM C 303, ASTM C 692, ASTM C 665, ASTM C 795, ASTM C 871, ASTM C 518, ASTM C 1104, ASTM C 553, ASTM C-177, ASTM C-411, ASTM E-136, ASTM C-356, ASTM E-84, ASTM C-303, ASTM C-692, ASTM C-665, ASTM C-795, ASTM C-871, ASTM C-518, ASTM C-1104, ASTM C-553sdspipe-and-tank
RockwoolROCKWOOL ProRox MA 930 Wrap / Mat Mineral Wool InsulationASTM C177 ASTM C411: Hot Surface Performance: 1200°F- (650°C) ASTM E136 / CAN4 S114: Non-Combustible ASTM C356: Linear Shrinkage: ≤ 2 % at 1200°F- (650°C) ASTM E84 (UL 723): Flame spread index = 0 ; Smoke development index = 0 CAN/ULC S102: Flame spread index = 0 ; Smoke development index = 0 ASTM C303: Actual Density = 3.5 lb/ft³ - (56 kg/m³), Nominal Density = 4.0 lb/ft3 ASTM C692: Stress Corrosion Cracking Tendency of Austenitic Stainless Steel - Passed ASTM C665: Corrosion of Steel - Passed ASTM C795 / ASTM C871 ASTM C518(C177): R-Value / inch @ 75 F - 4.0 hr.ft2 .F/Btu ASTM C1104: Water Absorption/ Vapor Sorption - < 1% Weight ASTM C553: Complies with Type VIIASTM C177, ASTM C411, ASTM E136, ASTM C356, ASTM E84, ASTM C303, ASTM C692, ASTM C665, ASTM C795, ASTM C871, ASTM C518, ASTM C1104, ASTM C553, ASTM C 177, ASTM C 411, ASTM E 136, ASTM C 356, ASTM E 84, ASTM C 303, ASTM C 692, ASTM C 665, ASTM C 795, ASTM C 871, ASTM C 518, ASTM C 1104, ASTM C 553, ASTM C-177, ASTM C-411, ASTM E-136, ASTM C-356, ASTM E-84, ASTM C-303, ASTM C-692, ASTM C-665, ASTM C-795, ASTM C-871, ASTM C-518, ASTM C-1104, ASTM C-553tdspipe-and-tank
RockwoolROCKWOOL ProRox MA 940 Wrap / Mat Mineral Wool InsulationASTM C177 ASTM C411: Hot Surface Performance: 1200°F- (650°C) ASTM E136 / CAN4 S114: Non-Combustible ASTM C356: Linear Shrinkage: ≤ 2 % at 1200°F- (650°C) ASTM E84 (UL 723): Flame spread index = 0 ; Smoke development index = 0 CAN/ULC S102: Flame spread index = 0 ; Smoke development index = 0 ASTM C303: Actual Density = 4.4 lb/ft³ - (70 kg/m³), Nominal Density = 6.0 lb/ft3 ASTM C692: Stress Corrosion Cracking Tendency of Austenitic Stainless Steel - Passed ASTM C665: Corrosion of Steel - Passed ASTM C795 / ASTM C871 ASTM C518(C177): R-Value / inch @ 75 F - 4.2 hr.ft2 .F/Btu ASTM C1104: Water Absorption/ Vapor Sorption - < 1% Weight ASTM C553: Complies with Type VIIASTM C612, ASTM C177, ASTM C411 ASTM E136, ASTM C356, ASTM E84, ASTM C303, ASTM C692, ASTM C665, ASTM C795, ASTM C871, ASTM C518, ASTM C1104, ASTM C553, ASTM C795, ASTM C 612, ASTM C 177, ASTM C 411 ASTM E 136, ASTM C 356, ASTM E 84, ASTM C 303, ASTM C 692, ASTM C 665, ASTM C 795, ASTM C 871, ASTM C 518, ASTM C 1104, ASTM C 553, ASTM C 795, ASTM C-612, ASTM C-177, ASTM C-411 ASTM E-136, ASTM C-356, ASTM E-84, ASTM C-303, ASTM C-692, ASTM C-665, ASTM C-795, ASTM C-871, ASTM C-518, ASTM C-1104, ASTM C-553, ASTM C-795tdspipe-and-tank
RockwoolROCKWOOL ProRox MA 940 Wrap / Mat Mineral Wool InsulationASTM C177 ASTM C411: Hot Surface Performance: 1200°F- (650°C) ASTM E136 / CAN4 S114: Non-Combustible ASTM C356: Linear Shrinkage: ≤ 2 % at 1200°F- (650°C) ASTM E84 (UL 723): Flame spread index = 0 ; Smoke development index = 0 CAN/ULC S102: Flame spread index = 0 ; Smoke development index = 0 ASTM C303: Actual Density = 4.4 lb/ft³ - (70 kg/m³), Nominal Density = 6.0 lb/ft3 ASTM C692: Stress Corrosion Cracking Tendency of Austenitic Stainless Steel - Passed ASTM C665: Corrosion of Steel - Passed ASTM C795 / ASTM C871 ASTM C518(C177): R-Value / inch @ 75 F - 4.2 hr.ft2 .F/Btu ASTM C1104: Water Absorption/ Vapor Sorption - < 1% Weight ASTM C553: Complies with Type VIIASTM C612, ASTM C177, ASTM C411 ASTM E136, ASTM C356, ASTM E84, ASTM C303, ASTM C692, ASTM C665, ASTM C795, ASTM C871, ASTM C518, ASTM C1104, ASTM C553, ASTM C795, ASTM C 612, ASTM C 177, ASTM C 411 ASTM E 136, ASTM C 356, ASTM E 84, ASTM C 303, ASTM C 692, ASTM C 665, ASTM C 795, ASTM C 871, ASTM C 518, ASTM C 1104, ASTM C 553, ASTM C 795, ASTM C-612, ASTM C-177, ASTM C-411 ASTM E-136, ASTM C-356, ASTM E-84, ASTM C-303, ASTM C-692, ASTM C-665, ASTM C-795, ASTM C-871, ASTM C-518, ASTM C-1104, ASTM C-553, ASTM C-795sdspipe-and-tank
RockwoolROCKWOOL ProRox MA 960 Wrap / Mat Mineral Wool InsulationASTM C177 ASTM C411: Hot Surface Performance: 1200°F- (650°C) ASTM E136 / CAN4 S114: Non-Combustible ASTM C356: Linear Shrinkage: ≤ 2 % at 1200°F- (650°C) ASTM E84 (UL 723): Flame spread index = 0 ; Smoke development index = 0 CAN/ULC S102: Flame spread index = 0 ; Smoke development index = 0 ASTM C167: Actual Density = 5.68 lb/ft³ - (91 kg/m³), Nominal Density = 8.0 lb/ft3 ASTM C692: Stress Corrosion Cracking Tendency of Austenitic Stainless Steel - Passed ASTM C665: Corrosion of Steel - Passed ASTM C795 / ASTM C871 ASTM C518(C177): R-Value / inch @ 75 F - 4.2 hr.ft2 .F/Btu ASTM C1104: Water Absorption/ Vapor Sorption - < 1% Weight ASTM C553: Complies with Type VIIASTM C553, ASTM C177, ASTM C411 ASTM E136, ASTM C356, ASTM E84, ASTM 167, ASTM C692 ASTM C665, ASTM C795, ASTM C518, ASTM C1104, ASTM C553, ASTM C 553, ASTM C 177, ASTM C 411 ASTM E 136, ASTM C 356, ASTM E 84, ASTM 167, ASTM C 692 ASTM C 665, ASTM C 795, ASTM C 518, ASTM C 1104, ASTM C 553, ASTM C-553, ASTM C-177, ASTM C-411 ASTM E-136, ASTM C-356, ASTM E-84, ASTM 167, ASTM C-692 ASTM C-665, ASTM C-795, ASTM C-518, ASTM C-1104, ASTM C-553tdspipe-and-tank
RockwoolROCKWOOL ProRox MA 960 Wrap / Mat Mineral Wool InsulationASTM C177 ASTM C411: Hot Surface Performance: 1200°F- (650°C) ASTM E136 / CAN4 S114: Non-Combustible ASTM C356: Linear Shrinkage: ≤ 2 % at 1200°F- (650°C) ASTM E84 (UL 723): Flame spread index = 0 ; Smoke development index = 0 CAN/ULC S102: Flame spread index = 0 ; Smoke development index = 0 ASTM C167: Actual Density = 5.68 lb/ft³ - (91 kg/m³), Nominal Density = 8.0 lb/ft3 ASTM C692: Stress Corrosion Cracking Tendency of Austenitic Stainless Steel - Passed ASTM C665: Corrosion of Steel - Passed ASTM C795 / ASTM C871 ASTM C518(C177): R-Value / inch @ 75 F - 4.2 hr.ft2 .F/Btu ASTM C1104: Water Absorption/ Vapor Sorption - < 1% Weight ASTM C553: Complies with Type VIIASTM C553, ASTM C177, ASTM C411 ASTM E136, ASTM C356, ASTM E84, ASTM 167, ASTM C692 ASTM C665, ASTM C795, ASTM C518, ASTM C1104, ASTM C553, ASTM C 553, ASTM C 177, ASTM C 411 ASTM E 136, ASTM C 356, ASTM E 84, ASTM 167, ASTM C 692 ASTM C 665, ASTM C 795, ASTM C 518, ASTM C 1104, ASTM C 553, ASTM C-553, ASTM C-177, ASTM C-411 ASTM E-136, ASTM C-356, ASTM E-84, ASTM 167, ASTM C-692 ASTM C-665, ASTM C-795, ASTM C-518, ASTM C-1104, ASTM C-553sdspipe-and-tank
RockwoolROCKWOOL ProRox PS 960 With WR-TechEN 14707: Maximum Service Temperature - 650°C DIN 4102-17: Melting point >1000°C EN 13501-1 IMO 2010 FTPC: Reaction to fire - Non Combustible EN 13470: Nominal density - ≥ 100 kg/m3 EN 13468: Corrosion resistance -Trace quantity of water leachable chloride ions: ≤ 10 ppm EN 13472: ≤ 0,2 kg/m2 , ≤ 0,2 kg/m2 (After 24 hrs. pre-heating at 250°C) EN 14303: Water vapour diffusion resistance - μ = 1 EN 29053: Air Flow Resistivity - > 80 kPa.s/m2 VW 3.10.7: Free from substances (e.g. silicone oil) that might impair surface wetting EN 14303: MW EN 14303-T9(T8 if Do <150)-ST(+)650-WS1-CL10 AGI Q132-06: 10.04.04.65.99ASTM C795, ASTM C547, ASTM C 795, ASTM C 547, ASTM C-795, ASTM C-547sdspipe-insulation
RockwoolROCKWOOL ProRox PS 960 With WR-TechEN 14707: Maximum Service Temperature - 650°C DIN 4102-17: Melting point >1000°C EN 13501-1 IMO 2010 FTPC: Reaction to fire - Non Combustible EN 13470: Nominal density - ≥ 100 kg/m3 EN 13468: Corrosion resistance -Trace quantity of water leachable chloride ions: ≤ 10 ppm EN 13472: ≤ 0,2 kg/m2 , ≤ 0,2 kg/m2 (After 24 hrs. pre-heating at 250°C) EN 14303: Water vapour diffusion resistance - μ = 1 EN 29053: Air Flow Resistivity - > 80 kPa.s/m2 VW 3.10.7: Free from substances (e.g. silicone oil) that might impair surface wetting EN 14303: MW EN 14303-T9(T8 if Do <150)-ST(+)650-WS1-CL10 AGI Q132-06: 10.04.04.65.99ASTM C795, ASTM C547, ASTM C 795, ASTM C 547, ASTM C-795, ASTM C-547tdspipe-insulation
RockwoolROCKWOOL ProRox SL 430 NA Pipe and Tank Lamella WrapASTM C177 ASTM C411: Hot Surface Performance: 1200°F- (650°C) ASTM E136 / CAN4 S114: Non-Combustible ASTM C356: Linear Shrinkage: 0.35 % at 1200 °F- (650 °C) ASTM E84 (UL 723): Flame spread index = 0; Smoke developed index = 0 CAN/ULC S102: Flame spread index = 0; Smoke developed index = 0 ASTM C303: Actual Density = 3.5 lb/ft³ - (56 kg/m³) ASTM C692: Stress Corrosion Cracking Tendency of Austenitic Stainless Steel = Passed ASTM C665: Corrosion of Steel = Passed ASTM C795 / ASTM C871 ASTM C518 (C177): 4.1 hr. ft2 .°F/BTU ASTM C1104: Water Absorption/ Vapor Sorption < 1 % Weight ASTM C165: 71psf (3.4kPa) @ 10 % compression ASTM C612: Complies with Type: IVAASTM C177, ASTM C411, ASTM E136, ASTM C356, ASTM E84, ASTM C303, ASTM C692, ASTM C665, ASTM C795, ASTM C871, ASTM C518, ASTM C1104, ASTM C165, ASTM C612, ASTM C 177, ASTM C 411, ASTM E 136, ASTM C 356, ASTM E 84, ASTM C 303, ASTM C 692, ASTM C 665, ASTM C 795, ASTM C 871, ASTM C 518, ASTM C 1104, ASTM C 165, ASTM C 612, ASTM C-177, ASTM C-411, ASTM E-136, ASTM C-356, ASTM E-84, ASTM C-303, ASTM C-692, ASTM C-665, ASTM C-795, ASTM C-871, ASTM C-518, ASTM C-1104, ASTM C-165, ASTM C-612tdspipe-and-tank
RockwoolROCKWOOL ProRox SL 430 NA Pipe and Tank Lamella WrapASTM C177 ASTM C411: Hot Surface Performance: 1200°F- (650°C) ASTM E136 / CAN4 S114: Non-Combustible ASTM C356: Linear Shrinkage: 0.35 % at 1200 °F- (650 °C) ASTM E84 (UL 723): Flame spread index = 0; Smoke developed index = 0 CAN/ULC S102: Flame spread index = 0; Smoke developed index = 0 ASTM C303: Actual Density = 3.5 lb/ft³ - (56 kg/m³) ASTM C692: Stress Corrosion Cracking Tendency of Austenitic Stainless Steel = Passed ASTM C665: Corrosion of Steel = Passed ASTM C795 / ASTM C871 ASTM C518 (C177): 4.1 hr. ft2 .°F/BTU ASTM C1104: Water Absorption/ Vapor Sorption < 1 % Weight ASTM C165: 71psf (3.4kPa) @ 10 % compression ASTM C612: Complies with Type: IVAASTM C177, ASTM C411, ASTM E136, ASTM C356, ASTM E84, ASTM C303, ASTM C692, ASTM C665, ASTM C795, ASTM C871, ASTM C518, ASTM C1104, ASTM C165, ASTM C612, ASTM C 177, ASTM C 411, ASTM E 136, ASTM C 356, ASTM E 84, ASTM C 303, ASTM C 692, ASTM C 665, ASTM C 795, ASTM C 871, ASTM C 518, ASTM C 1104, ASTM C 165, ASTM C 612, ASTM C-177, ASTM C-411, ASTM E-136, ASTM C-356, ASTM E-84, ASTM C-303, ASTM C-692, ASTM C-665, ASTM C-795, ASTM C-871, ASTM C-518, ASTM C-1104, ASTM C-165, ASTM C-612sdspipe-and-tank
RockwoolROCKWOOL ProRox SL 450 NA V-Groove Pipe SectionsASTM C177 ASTM C411: Hot Surface Performance: 1200°F- (650°C) CAN4 S114: Non-Combustible ASTM C356: ≤ 1 % at 1200°F- (650°C) ASTM E84 (UL 723): Flame spread index = 0; Smoke developed index = 0 CAN/ULC S102: Flame spread index = 0; Smoke developed index = 0 ASTM C303: Actual Density = 9.0 lb/ft³ - (144 kg/m³), Nominal Density = 12.0 lb/ft³ ASTM C692: Stress Corrosion Cracking Tendency of Austenitic Stainless Steel = Passed ASTM C665: Corrosion of Steel = Passed ASTM C795 / ASTM C871 ASTM C518 (C177): 4.0 hr. ft2 .°F/BTU ASTM C1104: Water Absorption/ Vapor Sorption < 1 % Weight ASTM C165: 418psf (20kPa) @ 10 % compression ASTM C612: Complies with Type: IVBASTM C177, ASTM C411, ASTM E136, ASTM C356, ASTM E84, ASTM C303, ASTM C692, ASTM C665, ASTM C795, ASTM C871, ASTM C518, ASTM C1104, ASTM C165, ASTM C612, ASTM C 177, ASTM C 411, ASTM E 136, ASTM C 356, ASTM E 84, ASTM C 303, ASTM C 692, ASTM C 665, ASTM C 795, ASTM C 871, ASTM C 518, ASTM C 1104, ASTM C 165, ASTM C 612, ASTM C-177, ASTM C-411, ASTM E-136, ASTM C-356, ASTM E-84, ASTM C-303, ASTM C-692, ASTM C-665, ASTM C-795, ASTM C-871, ASTM C-518, ASTM C-1104, ASTM C-165, ASTM C-612tdspipe-and-tank
RockwoolROCKWOOL ProRox SL 450 NA V-Groove Pipe SectionsASTM C177 ASTM C411: Hot Surface Performance: 1200°F- (650°C) CAN4 S114: Non-Combustible ASTM C356: ≤ 1 % at 1200°F- (650°C) ASTM E84 (UL 723): Flame spread index = 0; Smoke developed index = 0 CAN/ULC S102: Flame spread index = 0; Smoke developed index = 0 ASTM C303: Actual Density = 9.0 lb/ft³ - (144 kg/m³), Nominal Density = 12.0 lb/ft³ ASTM C692: Stress Corrosion Cracking Tendency of Austenitic Stainless Steel = Passed ASTM C665: Corrosion of Steel = Passed ASTM C795 / ASTM C871 ASTM C518 (C177): 4.0 hr. ft2 .°F/BTU ASTM C1104: Water Absorption/ Vapor Sorption < 1 % Weight ASTM C165: 418psf (20kPa) @ 10 % compression ASTM C612: Complies with Type: IVBASTM C177, ASTM C411, ASTM E136, ASTM C356, ASTM E84, ASTM C303, ASTM C692, ASTM C665, ASTM C795, ASTM C871, ASTM C518, ASTM C1104, ASTM C165, ASTM C612, ASTM C 177, ASTM C 411, ASTM E 136, ASTM C 356, ASTM E 84, ASTM C 303, ASTM C 692, ASTM C 665, ASTM C 795, ASTM C 871, ASTM C 518, ASTM C 1104, ASTM C 165, ASTM C 612, ASTM C-177, ASTM C-411, ASTM E-136, ASTM C-356, ASTM E-84, ASTM C-303, ASTM C-692, ASTM C-665, ASTM C-795, ASTM C-871, ASTM C-518, ASTM C-1104, ASTM C-165, ASTM C-612sdspipe-and-tank
RockwoolROCKWOOL ProRox SL 460 NA Precision Cut Pipe SectionsASTM C177 ASTM C411: Hot Surface Performance: 1200°F- (650°C) CAN4 S114: Non-Combustible ASTM C356: ≤ 0.4 % at 1200°F- (650°C) ASTM E84 (UL 723): Flame spread index = 0; Smoke developed index = 0 CAN/ULC S102: Flame spread index = 0; Smoke developed index = 0 ASTM C303: Actual Density = 6.5 lb/ft³ - (Density 105 kg/m³) ASTM C692: Stress Corrosion Cracking Tendency of Austenitic Stainless Steel = Passed ASTM C665: Corrosion of Steel = Passed ASTM C795 / ASTM C871 ASTM C518 (C177): 4.2 hr. ft2 .°F/BTU ASTM C1104: Water Absorption/ Vapor Sorption < 1 % Weight ASTM C165: 720psf (34.4kPa) @ 10 % compression ASTM C612: Complies with Type: IVBASTM C177, ASTM C411, ASTM E136, ASTM C356, ASTM E84, ASTM C303, ASTM C692, ASTM C665, ASTM C795, ASTM C871, ASTM C518, ASTM C1104, ASTM C165, ASTM C612, ASTM C 177, ASTM C 411, ASTM E 136, ASTM C 356, ASTM E 84, ASTM C 303, ASTM C 692, ASTM C 665, ASTM C 795, ASTM C 871, ASTM C 518, ASTM C 1104, ASTM C 165, ASTM C 612, ASTM C-177, ASTM C-411, ASTM E-136, ASTM C-356, ASTM E-84, ASTM C-303, ASTM C-692, ASTM C-665, ASTM C-795, ASTM C-871, ASTM C-518, ASTM C-1104, ASTM C-165, ASTM C-612tdspipe-insulation
RockwoolROCKWOOL ProRox SL 460 NA Precision Cut Pipe SectionsASTM C177 ASTM C411: Hot Surface Performance: 1200°F- (650°C) CAN4 S114: Non-Combustible ASTM C356: ≤ 0.4 % at 1200°F- (650°C) ASTM E84 (UL 723): Flame spread index = 0; Smoke developed index = 0 CAN/ULC S102: Flame spread index = 0; Smoke developed index = 0 ASTM C303: Actual Density = 6.5 lb/ft³ - (Density 105 kg/m³) ASTM C692: Stress Corrosion Cracking Tendency of Austenitic Stainless Steel = Passed ASTM C665: Corrosion of Steel = Passed ASTM C795 / ASTM C871 ASTM C518 (C177): 4.2 hr. ft2 .°F/BTU ASTM C1104: Water Absorption/ Vapor Sorption < 1 % Weight ASTM C165: 720psf (34.4kPa) @ 10 % compression ASTM C612: Complies with Type: IVBASTM C177, ASTM C411, ASTM E136, ASTM C356, ASTM E84, ASTM C303, ASTM C692, ASTM C665, ASTM C795, ASTM C871, ASTM C518, ASTM C1104, ASTM C165, ASTM C612, ASTM C 177, ASTM C 411, ASTM E 136, ASTM C 356, ASTM E 84, ASTM C 303, ASTM C 692, ASTM C 665, ASTM C 795, ASTM C 871, ASTM C 518, ASTM C 1104, ASTM C 165, ASTM C 612, ASTM C-177, ASTM C-411, ASTM E-136, ASTM C-356, ASTM E-84, ASTM C-303, ASTM C-692, ASTM C-665, ASTM C-795, ASTM C-871, ASTM C-518, ASTM C-1104, ASTM C-165, ASTM C-612sdspipe-insulation
RockwoolROCKWOOL ProRox-Enerwrap MA 960 Industrial Insulation BlanketASTM C177 ASTM C411: Hot Surface Performance: 1200°F- (650°C) CAN4 S114: Non-Combustible ASTM C356: ≤ 2 % at 1200°F- (650°C) ASTM E84 (UL 723): Flame spread index = 0; Smoke developed index = 0 CAN/ULC S102: Flame spread index = 0; Smoke developed index = 0 ASTM C167: Actual Density = 5.68 lb/ft³ - (91 kg/m³), Nominal Density = 8.0 lb/ft³ ASTM C692: Stress Corrosion Cracking Tendency of Austenitic Stainless Steel = Passed ASTM C665: Corrosion of Steel = Passed ASTM C795 / ASTM C871 ASTM C518 (C177): 4.2 hr. ft2 .°F/BTU ASTM C1104: Water Absorption/ Vapor Sorption < 1 % Weight ASTM C165: 720psf (34.4kPa) @ 10 % compression ASTM C553: Complies with Type VIIASTM C177, ASTM C411, ASTM E136, ASTM C356, ASTM E84, ASTM 167, ASTM C692, ASTM C665, ASTM C795, ASTM C795, ASTM C1104, ASTM C553, ASTM C 177, ASTM C 411, ASTM E 136, ASTM C 356, ASTM E 84, ASTM 167, ASTM C 692, ASTM C 665, ASTM C 795, ASTM C 795, ASTM C 1104, ASTM C 553, ASTM C-177, ASTM C-411, ASTM E-136, ASTM C-356, ASTM E-84, ASTM 167, ASTM C-692, ASTM C-665, ASTM C-795, ASTM C-795, ASTM C-1104, ASTM C-553tdspipe-and-tank
RockwoolROCKWOOL ProRox-Enerwrap MA 960 Industrial Insulation BlanketASTM C177 ASTM C411: Hot Surface Performance: 1200°F- (650°C) CAN4 S114: Non-Combustible ASTM C356: ≤ 2 % at 1200°F- (650°C) ASTM E84 (UL 723): Flame spread index = 0; Smoke developed index = 0 CAN/ULC S102: Flame spread index = 0; Smoke developed index = 0 ASTM C167: Actual Density = 5.68 lb/ft³ - (91 kg/m³), Nominal Density = 8.0 lb/ft³ ASTM C692: Stress Corrosion Cracking Tendency of Austenitic Stainless Steel = Passed ASTM C665: Corrosion of Steel = Passed ASTM C795 / ASTM C871 ASTM C518 (C177): 4.2 hr. ft2 .°F/BTU ASTM C1104: Water Absorption/ Vapor Sorption < 1 % Weight ASTM C165: 720psf (34.4kPa) @ 10 % compression ASTM C553: Complies with Type VIIASTM C177, ASTM C411, ASTM E136, ASTM C356, ASTM E84, ASTM 167, ASTM C692, ASTM C665, ASTM C795, ASTM C795, ASTM C1104, ASTM C553, ASTM C 177, ASTM C 411, ASTM E 136, ASTM C 356, ASTM E 84, ASTM 167, ASTM C 692, ASTM C 665, ASTM C 795, ASTM C 795, ASTM C 1104, ASTM C 553, ASTM C-177, ASTM C-411, ASTM E-136, ASTM C-356, ASTM E-84, ASTM 167, ASTM C-692, ASTM C-665, ASTM C-795, ASTM C-795, ASTM C-1104, ASTM C-553sdspipe-and-tank
RockwoolROCKWOOL Rockboard 40/60 Interior Insulation BoardRockboard 40: Density: 4 lb/ft3 (64Kg/m3) ASTM C612: Mineral Fiber Block and Board Thermal Insulation - Type IVA compliant ASTM C356: Linear Shrinkage - 0.47% @ 1200 °F (650 °C) ASTM C165 - Compressive Strength @ 10% - 90 psf (4.3 kPa), @25% - 226 psf (10.8 kPa) ASTM C518 (C177): R-value/inch @ 75°F - 4.2 hr.ft2.°F/BTU ASTM C1104: Moisture Sorption <0.08% ASTM C1338: Determoination of Fungi resistance - passed ASTM E84 (UL 723): Flame spread index = 0; Smoke developed index = 0. CAN/ULC S102: Flame spread index = 0; Smoke developed index = 0 CAN/ULC S114: Determination of Non Combustibility of Building Materials - Non Combustible ASTM C411: Hot Surface Performance - 1200°F (650°C) ASTM C423 Rockboard 60: Density: 6 lb/ft3 (96Kg/m3) ASTM C612: Mineral Fiber Block and Board Thermal Insulation - Type IVB compliant ASTM C356: Linear Shrinkage - 1.14% @ 1200 °F (650 °C) ASTM C165 - Compressive Strength @ 10% - 196 psf (9.4 kPa), @25% - 547 psf (26.2 kPa) ASTM C518 (C177): R-value/inch @ 75°F - 4.3 hr.ft2.°F/BTU ASTM C1104: Moisture Sorption <0.08% ASTM C1338: Determoination of Fungi resistance - passed ASTM E84 (UL 723): Flame spread index = 0; Smoke developed index = 0. CAN/ULC S102: Flame spread index = 0; Smoke developed index = 0 CAN/ULC S114: Determination of Non Combustibility of Building Materials - Non Combustible ASTM C612: Hot Surface Performance - 1200°F (650°C) ASTM C423 Rockboard 80: Density: 8 lb/ft3 (128Kg/m3) ASTM C612: Mineral Fiber Block and Board Thermal Insulation - Type IVB compliant ASTM C356: Linear Shrinkage - 0.41% @ 1200 °F (650 °C) ASTM C165 - Compressive Strength @ 10% - 353 psf (16.9 kPa), @25% - 794 psf (38 kPa) ASTM C518 (C177): R-value/inch @ 75°F - 4.0 hr.ft2.°F/BTU ASTM C1104: Moisture Sorption <0.08% ASTM C1338: Determoination of Fungi resistance - passed ASTM E84 (UL 723): Flame spread index = 0; Smoke developed index = 0. CAN/ULC S102: Flame spread index = 0; Smoke developed index = 0 CAN/ULC S114: Determination of Non Combustibility of Building Materials - Non Combustible ASTM C612: Hot Surface Performance - 1200°F (650°C) ASTM C423ASTM C356, ASTM C165, ASTM C612, ASTM C423, ASTM C518, ASTM C1104, ASTM C1338, ASTM E84, ASTM C411, ASTM C 356, ASTM C 165, ASTM C 612, ASTM C 423, ASTM C 518, ASTM C 1104, ASTM C 1338, ASTM E 84, ASTM C 411, ASTM C-356, ASTM C-165, ASTM C-612, ASTM C-423, ASTM C-518, ASTM C-1104, ASTM C-1338, ASTM E-84, ASTM C-411tdsmineral-wool-commercial
RockwoolROCKWOOL Rockboard 40/60 Interior Insulation BoardRockboard 40: Density: 4 lb/ft3 (64Kg/m3) ASTM C612: Mineral Fiber Block and Board Thermal Insulation - Type IVA compliant ASTM C356: Linear Shrinkage - 0.47% @ 1200 °F (650 °C) ASTM C165 - Compressive Strength @ 10% - 90 psf (4.3 kPa), @25% - 226 psf (10.8 kPa) ASTM C518 (C177): R-value/inch @ 75°F - 4.2 hr.ft2.°F/BTU ASTM C1104: Moisture Sorption <0.08% ASTM C1338: Determoination of Fungi resistance - passed ASTM E84 (UL 723): Flame spread index = 0; Smoke developed index = 0. CAN/ULC S102: Flame spread index = 0; Smoke developed index = 0 CAN/ULC S114: Determination of Non Combustibility of Building Materials - Non Combustible ASTM C411: Hot Surface Performance - 1200°F (650°C) ASTM C423 Rockboard 60: Density: 6 lb/ft3 (96Kg/m3) ASTM C612: Mineral Fiber Block and Board Thermal Insulation - Type IVB compliant ASTM C356: Linear Shrinkage - 1.14% @ 1200 °F (650 °C) ASTM C165 - Compressive Strength @ 10% - 196 psf (9.4 kPa), @25% - 547 psf (26.2 kPa) ASTM C518 (C177): R-value/inch @ 75°F - 4.3 hr.ft2.°F/BTU ASTM C1104: Moisture Sorption <0.08% ASTM C1338: Determoination of Fungi resistance - passed ASTM E84 (UL 723): Flame spread index = 0; Smoke developed index = 0. CAN/ULC S102: Flame spread index = 0; Smoke developed index = 0 CAN/ULC S114: Determination of Non Combustibility of Building Materials - Non Combustible ASTM C612: Hot Surface Performance - 1200°F (650°C) ASTM C423 Rockboard 80: Density: 8 lb/ft3 (128Kg/m3) ASTM C612: Mineral Fiber Block and Board Thermal Insulation - Type IVB compliant ASTM C356: Linear Shrinkage - 0.41% @ 1200 °F (650 °C) ASTM C165 - Compressive Strength @ 10% - 353 psf (16.9 kPa), @25% - 794 psf (38 kPa) ASTM C518 (C177): R-value/inch @ 75°F - 4.0 hr.ft2.°F/BTU ASTM C1104: Moisture Sorption <0.08% ASTM C1338: Determoination of Fungi resistance - passed ASTM E84 (UL 723): Flame spread index = 0; Smoke developed index = 0. CAN/ULC S102: Flame spread index = 0; Smoke developed index = 0 CAN/ULC S114: Determination of Non Combustibility of Building Materials - Non Combustible ASTM C612: Hot Surface Performance - 1200°F (650°C) ASTM C423ASTM C356, ASTM C165, ASTM C612, ASTM C423, ASTM C518, ASTM C1104, ASTM C1338, ASTM E84, ASTM C411, ASTM C 356, ASTM C 165, ASTM C 612, ASTM C 423, ASTM C 518, ASTM C 1104, ASTM C 1338, ASTM E 84, ASTM C 411, ASTM C-356, ASTM C-165, ASTM C-612, ASTM C-423, ASTM C-518, ASTM C-1104, ASTM C-1338, ASTM E-84, ASTM C-411sdsmineral-wool-commercial
RockwoolRockwool (Roxul) Safe 45 Residential Party Wall InsulationASTM C612: Type IVA Compliant. CAN/ULC S702: Mineral Fiber Thermal Insulation for buildings - Type 1 Compliant ASTM E84 (UL 723): Flame spread index = 0; Smoke developed index = 0. CAN/ULC S102: Flame spread index = 0; Smoke developed index = 0 CAN/ULC S114: Determination of Non Combustibility of Building Materials - Non Combustible ASTM E136: Behaviour of materials at 750°C - Non Combustible ASTM C303: Actual Density - 4.4 lbs/ft³, ASTM C356: Linear Shrinkage - <1% @ 1200°F ASTM C795: Stress Corrosion Cracking Tendency of Austenitic Stainless Steel - Passed ASTM C665: Corrosion of Steel - Passed ASTM C518 (C177): R-Value / inch @ 75 F: 4.2 hr.ft2 .F/Btu. ASTM C1104: Moisture Sorption - 0.03% by weight ASTM C1338: Determination of Fungi Resistance - PassedASTM C612, ASTM E84, ASTM E136, ASTM C303, ASTM C518, ASTM C356, ASTM C795, ASTM C665, ASTM C1104, ASTM C1338, ASTM C 612, ASTM E 84, ASTM E 136, ASTM C 303, ASTM C 518, ASTM C 356, ASTM C 795, ASTM C 665, ASTM C 1104, ASTM C 1338, ASTM C-612, ASTM E-84, ASTM E-136, ASTM C-303, ASTM C-518, ASTM C-356, ASTM C-795, ASTM C-665, ASTM C-1104, ASTM C-1338tdsmineral-wool-commercial
RockwoolRockwool (Roxul) Safe 45 Residential Party Wall InsulationASTM C612: Type IVA Compliant. CAN/ULC S702: Mineral Fiber Thermal Insulation for buildings - Type 1 Compliant ASTM E84 (UL 723): Flame spread index = 0; Smoke developed index = 0. CAN/ULC S102: Flame spread index = 0; Smoke developed index = 0 CAN/ULC S114: Determination of Non Combustibility of Building Materials - Non Combustible ASTM E136: Behaviour of materials at 750°C - Non Combustible ASTM C303: Actual Density - 4.4 lbs/ft³, ASTM C356: Linear Shrinkage - <1% @ 1200°F ASTM C795: Stress Corrosion Cracking Tendency of Austenitic Stainless Steel - Passed ASTM C665: Corrosion of Steel - Passed ASTM C518 (C177): R-Value / inch @ 75 F: 4.2 hr.ft2 .F/Btu. ASTM C1104: Moisture Sorption - 0.03% by weight ASTM C1338: Determination of Fungi Resistance - PassedASTM C612, ASTM E84, ASTM E136, ASTM C303, ASTM C518, ASTM C356, ASTM C795, ASTM C665, ASTM C1104, ASTM C1338, ASTM C 612, ASTM E 84, ASTM E 136, ASTM C 303, ASTM C 518, ASTM C 356, ASTM C 795, ASTM C 665, ASTM C 1104, ASTM C 1338, ASTM C-612, ASTM E-84, ASTM E-136, ASTM C-303, ASTM C-518, ASTM C-356, ASTM C-795, ASTM C-665, ASTM C-1104, ASTM C-1338sdsmineral-wool-commercial
RockwoolROCKWOOL Safe 55 Firewall Insulation BoardASTM C612: Type IVB Compliant. CAN/ULC S702: Mineral Fiber Thermal Insulation for buildings - Type 1 Compliant ASTM E84 (UL 723): Flame spread index = 0; Smoke developed index = 0. CAN/ULC S102: Flame spread index = 0; Smoke developed index = 0 CAN/ULC S114: Determination of Non Combustibility of Building Materials - Non Combustible ASTM E136: Behaviour of materials at 750°C - Non Combustible, ULC 2 hr rated from interior side - W606, ULC 2 hr rated from both sides - W611, UL 2 hr rated from interior side - U655, UL 2 hr rated from both sides - U659 ASTM C303: Actual Density - 4.5 lbs/ft³, ASTM C356: Linear Shrinkage - <1% @ 1200°F ASTM C795: Stress Corrosion Cracking Tendency of Austenitic Stainless Steel - Passed ASTM C665: Corrosion of Steel - Passed ASTM C518 (C177): R-Value / inch @ 75 F: 4.2 hr.ft2 .F/Btu. ASTM C1104: Moisture Sorption - 0.04% by weight ASTM C1338: Determination of Fungi Resistance - PassedASTM C612, ASTM E84, ASTM E136, ASTM C303, ASTM C518, ASTM C356, ASTM C795, ASTM C665, ASTM C1104, ASTM C1338, ASTM C 612, ASTM E 84, ASTM E 136, ASTM C 303, ASTM C 518, ASTM C 356, ASTM C 795, ASTM C 665, ASTM C 1104, ASTM C 1338, ASTM C-612, ASTM E-84, ASTM E-136, ASTM C-303, ASTM C-518, ASTM C-356, ASTM C-795, ASTM C-665, ASTM C-1104, ASTM C-1338tdsmineral-wool-safing
RockwoolROCKWOOL Safe 55 Firewall Insulation BoardASTM C612: Type IVB Compliant. CAN/ULC S702: Mineral Fiber Thermal Insulation for buildings - Type 1 Compliant ASTM E84 (UL 723): Flame spread index = 0; Smoke developed index = 0. CAN/ULC S102: Flame spread index = 0; Smoke developed index = 0 CAN/ULC S114: Determination of Non Combustibility of Building Materials - Non Combustible ASTM E136: Behaviour of materials at 750°C - Non Combustible, ULC 2 hr rated from interior side - W606, ULC 2 hr rated from both sides - W611, UL 2 hr rated from interior side - U655, UL 2 hr rated from both sides - U659 ASTM C303: Actual Density - 4.5 lbs/ft³, ASTM C356: Linear Shrinkage - <1% @ 1200°F ASTM C795: Stress Corrosion Cracking Tendency of Austenitic Stainless Steel - Passed ASTM C665: Corrosion of Steel - Passed ASTM C518 (C177): R-Value / inch @ 75 F: 4.2 hr.ft2 .F/Btu. ASTM C1104: Moisture Sorption - 0.04% by weight ASTM C1338: Determination of Fungi Resistance - PassedASTM C612, ASTM E84, ASTM E136, ASTM C303, ASTM C518, ASTM C356, ASTM C795, ASTM C665, ASTM C1104, ASTM C1338, ASTM C 612, ASTM E 84, ASTM E 136, ASTM C 303, ASTM C 518, ASTM C 356, ASTM C 795, ASTM C 665, ASTM C 1104, ASTM C 1338, ASTM C-612, ASTM E-84, ASTM E-136, ASTM C-303, ASTM C-518, ASTM C-356, ASTM C-795, ASTM C-665, ASTM C-1104, ASTM C-1338sdsmineral-wool-safing
RockwoolROCKWOOL Safe 65 Firewall Insulation BoardASTM C612: Type IVB Compliant. CAN/ULC S702: Mineral Fiber Thermal Insulation for buildings - Type 1 Compliant ASTM E84 (UL 723): Flame spread index = 0; Smoke developed index = 0. CAN/ULC S102: Flame spread index = 0; Smoke developed index = 0 CAN/ULC S114: Determination of Non Combustibility of Building Materials - Non Combustible ASTM E136: Behaviour of materials at 750°C - Non Combustible, ULC 1 hr rated from interior side - W605, ULC 1 hr rated from both sides - W610, UL 1 hr rated from interior side - U654, UL 1 hr rated from both sides - U658 ASTM C303: Nominal density, Minimum - 6.0 lbs/ft³ (96 kg/m³) ASTM C356: Linear Shrinkage - <1% @ 1200°F ASTM C795: Stress Corrosion Cracking Tendency of Austenitic Stainless Steel - Passed ASTM C665: Corrosion of Steel - Passed ASTM C518 (C177): R-Value / inch @ 75 F: 4.2 hr.ft2 .F/Btu. ASTM C1104: Moisture Sorption - 0.04% by weight ASTM C1338: Determination of Fungi Resistance - PassedASTM C612, ASTM E84, ASTM E136, ASTM C303, ASTM C518, ASTM C356, ASTM C795, ASTM C665, ASTM C1104, ASTM C1338, ASTM C 612, ASTM E 84, ASTM E 136, ASTM C 303, ASTM C 518, ASTM C 356, ASTM C 795, ASTM C 665, ASTM C 1104, ASTM C 1338, ASTM C-612, ASTM E-84, ASTM E-136, ASTM C-303, ASTM C-518, ASTM C-356, ASTM C-795, ASTM C-665, ASTM C-1104, ASTM C-1338sdsmineral-wool-safing
RockwoolROCKWOOL Safe 65 Firewall Insulation BoardASTM C612: Type IVB Compliant. CAN/ULC S702: Mineral Fiber Thermal Insulation for buildings - Type 1 Compliant ASTM E84 (UL 723): Flame spread index = 0; Smoke developed index = 0. CAN/ULC S102: Flame spread index = 0; Smoke developed index = 0 CAN/ULC S114: Determination of Non Combustibility of Building Materials - Non Combustible ASTM E136: Behaviour of materials at 750°C - Non Combustible, ULC 1 hr rated from interior side - W605, ULC 1 hr rated from both sides - W610, UL 1 hr rated from interior side - U654, UL 1 hr rated from both sides - U658 ASTM C303: Nominal density, Minimum - 6.0 lbs/ft³ (96 kg/m³) ASTM C356: Linear Shrinkage - <1% @ 1200°F ASTM C795: Stress Corrosion Cracking Tendency of Austenitic Stainless Steel - Passed ASTM C665: Corrosion of Steel - Passed ASTM C518 (C177): R-Value / inch @ 75 F: 4.2 hr.ft2 .F/Btu. ASTM C1104: Moisture Sorption - 0.04% by weight ASTM C1338: Determination of Fungi Resistance - PassedASTM C612, ASTM E84, ASTM E136, ASTM C303, ASTM C518, ASTM C356, ASTM C795, ASTM C665, ASTM C1104, ASTM C1338, ASTM C 612, ASTM E 84, ASTM E 136, ASTM C 303, ASTM C 518, ASTM C 356, ASTM C 795, ASTM C 665, ASTM C 1104, ASTM C 1338, ASTM C-612, ASTM E-84, ASTM E-136, ASTM C-303, ASTM C-518, ASTM C-356, ASTM C-795, ASTM C-665, ASTM C-1104, ASTM C-1338tdsmineral-wool-safing
RockwoolROCKWOOL SeaRox FSL 618 NA Flexible Marine Insulation BoardsASTM C177: @ 75 F: 0.24 Btu.in/hr.ft^2 ASTM C411: 1200°F- (650°C) ASTM E136 / CAN4 S114: Non-Combustible ASTM C356: Linear Shrinkage: ≤ 1 % at 1200°F- (650°C) ASTM E84 (UL 723): Flame spread index = 0 ; Smoke development index = 0 CAN/ULC S102: Flame spread index = 0 ; Smoke development index = 0 ASTM C303: Actual Density = 6 lb/ft³ - (96 kg/m³) ASTM C692: Stress Corrosion Cracking Tendency of Austenitic Stainless Steel = Passed ASTM C665: Corrosion of Steel = Passed ASTM C795 / ASTM C871 ASTM C518 (C177): R-Value / inch @ 75°F - 4.1 hr. ft2 .°F/BTU ASTM C1104/1104M: Water Absorption/Vapor Sorption - < 1 % Weight ASTM C553: Complies with Type: VII US Coast Guard Certificate of Approval: 164.107/16/0, 164.107/17/0, 164.109/26/0, 164.112/142/0ASTM C177, ASTM C411, ASTM E136, ASTM C356, ASTM E84, ASTM C303, ASTM C692, ASTM C665, ASTM C795, ASTM C871, ASTM C518, ASTM C1104, ASTM C553, ASTM C 177, ASTM C 411, ASTM E 136, ASTM C 356, ASTM E 84, ASTM C 303, ASTM C 692, ASTM C 665, ASTM C 795, ASTM C 871, ASTM C 518, ASTM C 1104, ASTM C 553, ASTM C-177, ASTM C-411, ASTM E-136, ASTM C-356, ASTM E-84, ASTM C-303, ASTM C-692, ASTM C-665, ASTM C-795, ASTM C-871, ASTM C-518, ASTM C-1104, ASTM C-553tdsmineral-wool-safing
RockwoolROCKWOOL SeaRox FSL 618 NA Flexible Marine Insulation BoardsASTM C177: @ 75 F: 0.24 Btu.in/hr.ft^2 ASTM C411: 1200°F- (650°C) ASTM E136 / CAN4 S114: Non-Combustible ASTM C356: Linear Shrinkage: ≤ 1 % at 1200°F- (650°C) ASTM E84 (UL 723): Flame spread index = 0 ; Smoke development index = 0 CAN/ULC S102: Flame spread index = 0 ; Smoke development index = 0 ASTM C303: Actual Density = 6 lb/ft³ - (96 kg/m³) ASTM C692: Stress Corrosion Cracking Tendency of Austenitic Stainless Steel = Passed ASTM C665: Corrosion of Steel = Passed ASTM C795 / ASTM C871 ASTM C518 (C177): R-Value / inch @ 75°F - 4.1 hr. ft2 .°F/BTU ASTM C1104/1104M: Water Absorption/Vapor Sorption - < 1 % Weight ASTM C553: Complies with Type: VII US Coast Guard Certificate of Approval: 164.107/16/0, 164.107/17/0, 164.109/26/0, 164.112/142/0ASTM C177, ASTM C411, ASTM E136, ASTM C356, ASTM E84, ASTM C303, ASTM C692, ASTM C665, ASTM C795, ASTM C871, ASTM C518, ASTM C1104, ASTM C553, ASTM C 177, ASTM C 411, ASTM E 136, ASTM C 356, ASTM E 84, ASTM C 303, ASTM C 692, ASTM C 665, ASTM C 795, ASTM C 871, ASTM C 518, ASTM C 1104, ASTM C 553, ASTM C-177, ASTM C-411, ASTM E-136, ASTM C-356, ASTM E-84, ASTM C-303, ASTM C-692, ASTM C-665, ASTM C-795, ASTM C-871, ASTM C-518, ASTM C-1104, ASTM C-553sdsmineral-wool-safing
RockwoolROCKWOOL SeaRox PS 968 NA Marine Pipe InsulationASTM C335: @ 100 F: 0.25 Btu.in/hr.ft2 ASTM C411: 1200°F- (650°C) ASTM C411: Sag Resistance: ≤ 2 % at 1200°F - (650°C) ASTM C447: Maximum Use Temperature: 1200°F - (650°C) ASTM C356: Linear Shrinkage: ≤ 1 % at 1200°F - (650°C) ASTM E84 (UL 723): Flame spread index = 0 ; Smoke development index = 0 ASTM C303: Actual Density = 8.0 lb/ft³ - (128 kg/m³) ASTM C692: Stress Corrosion Cracking Tendency of Austenitic Stainless Steel = Passed ASTM C665: Corrosion of Steel = Passed ASTM C795 / ASTM C871 ASTM C1104: Water Absorption/Vapor Sorption - < 1 % Weight ASTM C547: Complies with Grade A Type I, II, IV ASTM C585: Inner and Outer diameter for nominal pipe sizes compliance US Coast Guard Certificate of Approval: 164.109/27/0ASTM C335, ASTM C411, ASTM C447, ASTM C356, ASTM E84, ASTM C692, ASTM C665, ASTM C795, ASTM C871, ASTM C1104, ASTM C547, ASTM C585, ASTM C 335, ASTM C 411, ASTM C 447, ASTM C 356, ASTM E 84, ASTM C 692, ASTM C 665, ASTM C 795, ASTM C 871, ASTM C 1104, ASTM C 547, ASTM C 585, ASTM C-335, ASTM C-411, ASTM C-447, ASTM C-356, ASTM E-84, ASTM C-692, ASTM C-665, ASTM C-795, ASTM C-871, ASTM C-1104, ASTM C-547, ASTM C-585sdsmarine-insulation
RockwoolROCKWOOL SeaRox PS 968 NA Marine Pipe InsulationASTM C335: @ 100 F: 0.25 Btu.in/hr.ft2 ASTM C411: 1200°F- (650°C) ASTM C411: Sag Resistance: ≤ 2 % at 1200°F - (650°C) ASTM C447: Maximum Use Temperature: 1200°F - (650°C) ASTM C356: Linear Shrinkage: ≤ 1 % at 1200°F - (650°C) ASTM E84 (UL 723): Flame spread index = 0 ; Smoke development index = 0 ASTM C303: Actual Density = 8.0 lb/ft³ - (128 kg/m³) ASTM C692: Stress Corrosion Cracking Tendency of Austenitic Stainless Steel = Passed ASTM C665: Corrosion of Steel = Passed ASTM C795 / ASTM C871 ASTM C1104: Water Absorption/Vapor Sorption - < 1 % Weight ASTM C547: Complies with Grade A Type I, II, IV ASTM C585: Inner and Outer diameter for nominal pipe sizes compliance US Coast Guard Certificate of Approval: 164.109/27/0ASTM C335, ASTM C411, ASTM C447, ASTM C356, ASTM E84, ASTM C692, ASTM C665, ASTM C795, ASTM C871, ASTM C1104, ASTM C547, ASTM C585, ASTM C 335, ASTM C 411, ASTM C 447, ASTM C 356, ASTM E 84, ASTM C 692, ASTM C 665, ASTM C 795, ASTM C 871, ASTM C 1104, ASTM C 547, ASTM C 585, ASTM C-335, ASTM C-411, ASTM C-447, ASTM C-356, ASTM E-84, ASTM C-692, ASTM C-665, ASTM C-795, ASTM C-871, ASTM C-1104, ASTM C-547, ASTM C-585tdsmarine-insulation
RockwoolROCKWOOL SeaRox SL 328 NA Marine Insulation BoardASTM C117: @ 75 F: 0.25 Btu.in/hr.ft2 ASTM C411: Hot surface performnace: 1200°F- (650°C) ASTM E136/CAN4 S114: Non combustible ASTM C356: Linear Shrinkage: ≤ 1 % at 1200°F - (650°C) ASTM E84 (UL 723): Flame spread index = 0 ; Smoke development index = 0 CAN/ULC S102: Flame spread index = 0 ; Smoke development index = 0 ASTM C303: Actual Density = 4 lb/ft³ - (64 kg/m³) ASTM C692: Stress Corrosion Cracking Tendency of Austenitic Stainless Steel = Passed ASTM C665: Corrosion of Steel = Passed ASTM C795 / ASTM C871 ASTM C518 (C177): R-Value / inch @ 75°F - 4.1 hr. ft2 .°F/BTU ASTM C1104: Water Absorption/Vapor Sorption - < 1 % Weight ASTM C612: Complies with Type IVA ASTM C423: NRC Rating: 1 US Coast Guard Certificate of Approval: 164.109/26/0, 164.112/142/0ASTM C177, ASTM C411, ASTM E136, ASTM C356, ASTM E84, ASTM C303, ASTM C692, ASTM C665, ASTM C795, ASTM C871, ASTM C518, ASTM C1104, ASTM C612, ASTM C423, ASTM C 177, ASTM C 411, ASTM E 136, ASTM C 356, ASTM E 84, ASTM C 303, ASTM C 692, ASTM C 665, ASTM C 795, ASTM C 871, ASTM C 518, ASTM C 1104, ASTM C 612, ASTM C 423, ASTM C-177, ASTM C-411, ASTM E-136, ASTM C-356, ASTM E-84, ASTM C-303, ASTM C-692, ASTM C-665, ASTM C-795, ASTM C-871, ASTM C-518, ASTM C-1104, ASTM C-612, ASTM C-423tdsmarine-insulation
RockwoolROCKWOOL SeaRox SL 328 NA Marine Insulation BoardASTM C117: @ 75 F: 0.25 Btu.in/hr.ft2 ASTM C411: Hot surface performnace: 1200°F- (650°C) ASTM E136/CAN4 S114: Non combustible ASTM C356: Linear Shrinkage: ≤ 1 % at 1200°F - (650°C) ASTM E84 (UL 723): Flame spread index = 0 ; Smoke development index = 0 CAN/ULC S102: Flame spread index = 0 ; Smoke development index = 0 ASTM C303: Actual Density = 4 lb/ft³ - (64 kg/m³) ASTM C692: Stress Corrosion Cracking Tendency of Austenitic Stainless Steel = Passed ASTM C665: Corrosion of Steel = Passed ASTM C795 / ASTM C871 ASTM C518 (C177): R-Value / inch @ 75°F - 4.1 hr. ft2 .°F/BTU ASTM C1104: Water Absorption/Vapor Sorption - < 1 % Weight ASTM C612: Complies with Type IVA ASTM C423: NRC Rating: 1 US Coast Guard Certificate of Approval: 164.109/26/0, 164.112/142/0ASTM C177, ASTM C411, ASTM E136, ASTM C356, ASTM E84, ASTM C303, ASTM C692, ASTM C665, ASTM C795, ASTM C871, ASTM C518, ASTM C1104, ASTM C612, ASTM C423, ASTM C 177, ASTM C 411, ASTM E 136, ASTM C 356, ASTM E 84, ASTM C 303, ASTM C 692, ASTM C 665, ASTM C 795, ASTM C 871, ASTM C 518, ASTM C 1104, ASTM C 612, ASTM C 423, ASTM C-177, ASTM C-411, ASTM E-136, ASTM C-356, ASTM E-84, ASTM C-303, ASTM C-692, ASTM C-665, ASTM C-795, ASTM C-871, ASTM C-518, ASTM C-1104, ASTM C-612, ASTM C-423sdsmarine-insulation
RockwoolROCKWOOL SeaRox SL 618 NA Series Marine Insulation BoardASTM C117: @ 75 F: 0.24 Btu.in/hr.ft2 ASTM C411: Hot surface performnace: 1200°F- (650°C) ASTM E136/CAN4 S114: Non combustible ASTM C356: Linear Shrinkage: ≤ 1 % at 1200°F - (650°C) ASTM E84 (UL 723): Flame spread index = 0 ; Smoke development index = 0 CAN/ULC S102: Flame spread index = 0 ; Smoke development index = 0 ASTM C303: Actual Density = 6 lb/ft³ - (96 kg/m³) ASTM C692: Stress Corrosion Cracking Tendency of Austenitic Stainless Steel = Passed ASTM C665: Corrosion of Steel = Passed ASTM C795 / ASTM C871 ASTM C518 (C177): R-Value / inch @ 75°F - 4.1 hr. ft2 .°F/BTU ASTM C1104: Water Absorption/Vapor Sorption - < 1 % Weight ASTM C612: Complies with Type IVB US Coast Guard Certificate of Approval: 164.107/16/0, 164.107/17/0, 164.109/26/0, 164.112/142/0ASTM C177, ASTM C411, ASTM C356, ASTM E84, ASTM C303, ASTM C692, ASTM C665, ASTM C795, ASTM C871, ASTM C518 , ASTM C1104, ASTM C612, ASTM C 177, ASTM C 411, ASTM C 356, ASTM E 84, ASTM C 303, ASTM C 692, ASTM C 665, ASTM C 795, ASTM C 871, ASTM C 518 , ASTM C 1104, ASTM C 612, ASTM C-177, ASTM C-411, ASTM C-356, ASTM E-84, ASTM C-303, ASTM C-692, ASTM C-665, ASTM C-795, ASTM C-871, ASTM C-518 , ASTM C-1104, ASTM C-612tdsmarine-insulation
RockwoolROCKWOOL SeaRox SL 618 NA Series Marine Insulation BoardASTM C117: @ 75 F: 0.24 Btu.in/hr.ft2 ASTM C411: Hot surface performnace: 1200°F- (650°C) ASTM E136/CAN4 S114: Non combustible ASTM C356: Linear Shrinkage: ≤ 1 % at 1200°F - (650°C) ASTM E84 (UL 723): Flame spread index = 0 ; Smoke development index = 0 CAN/ULC S102: Flame spread index = 0 ; Smoke development index = 0 ASTM C303: Actual Density = 6 lb/ft³ - (96 kg/m³) ASTM C692: Stress Corrosion Cracking Tendency of Austenitic Stainless Steel = Passed ASTM C665: Corrosion of Steel = Passed ASTM C795 / ASTM C871 ASTM C518 (C177): R-Value / inch @ 75°F - 4.1 hr. ft2 .°F/BTU ASTM C1104: Water Absorption/Vapor Sorption - < 1 % Weight ASTM C612: Complies with Type IVB US Coast Guard Certificate of Approval: 164.107/16/0, 164.107/17/0, 164.109/26/0, 164.112/142/0ASTM C177, ASTM C411, ASTM C356, ASTM E84, ASTM C303, ASTM C692, ASTM C665, ASTM C795, ASTM C871, ASTM C518 , ASTM C1104, ASTM C612, ASTM C 177, ASTM C 411, ASTM C 356, ASTM E 84, ASTM C 303, ASTM C 692, ASTM C 665, ASTM C 795, ASTM C 871, ASTM C 518 , ASTM C 1104, ASTM C 612, ASTM C-177, ASTM C-411, ASTM C-356, ASTM E-84, ASTM C-303, ASTM C-692, ASTM C-665, ASTM C-795, ASTM C-871, ASTM C-518 , ASTM C-1104, ASTM C-612sdsmarine-insulation
RockwoolROCKWOOL SeaRox SL 638 NA Series Marine Insulation BoardASTM C117: @ 75 F: 0.24 Btu.in/hr.ft2 ASTM C411: Hot surface performnace: 1200°F- (650°C) ASTM E136/CAN4 S114: Non combustible ASTM C356: Linear Shrinkage: ≤ 1 % at 1200°F - (650°C) ASTM E84 (UL 723): Flame spread index = 0 ; Smoke development index = 0 CAN/ULC S102: Flame spread index = 0 ; Smoke development index = 0 ASTM C303: Actual Density = 7 lb/ft³ - (112 kg/m³) ASTM C692: Stress Corrosion Cracking Tendency of Austenitic Stainless Steel = Passed ASTM C665: Corrosion of Steel = Passed ASTM C795 / ASTM C871 ASTM C518 (C177): R-Value / inch @ 75°F - 4.1 hr. ft2 .°F/BTU ASTM C1104/C1104M: Water Absorption/Vapor Sorption - < 1 % Weight ASTM C612: Complies with Type IVB US Coast Guard Certificate of Approval: 164.107/16/0, 164.107/17/0, 164.109/26/0, 164.112/142/0ASTM C177, ASTM C411, ASTM C356, ASTM E84, ASTM C303, ASTM C692, ASTM C665, ASTM C795, ASTM C871, ASTM C518 , ASTM C1104, ASTM C612, ASTM C 177, ASTM C 411, ASTM C 356, ASTM E 84, ASTM C 303, ASTM C 692, ASTM C 665, ASTM C 795, ASTM C 871, ASTM C 518 , ASTM C 1104, ASTM C 612, ASTM C-177, ASTM C-411, ASTM C-356, ASTM E-84, ASTM C-303, ASTM C-692, ASTM C-665, ASTM C-795, ASTM C-871, ASTM C-518 , ASTM C-1104, ASTM C-612tdsmarine-insulation
RockwoolROCKWOOL SeaRox SL 638 NA Series Marine Insulation BoardASTM C117: @ 75 F: 0.24 Btu.in/hr.ft2 ASTM C411: Hot surface performnace: 1200°F- (650°C) ASTM E136/CAN4 S114: Non combustible ASTM C356: Linear Shrinkage: ≤ 1 % at 1200°F - (650°C) ASTM E84 (UL 723): Flame spread index = 0 ; Smoke development index = 0 CAN/ULC S102: Flame spread index = 0 ; Smoke development index = 0 ASTM C303: Actual Density = 7 lb/ft³ - (112 kg/m³) ASTM C692: Stress Corrosion Cracking Tendency of Austenitic Stainless Steel = Passed ASTM C665: Corrosion of Steel = Passed ASTM C795 / ASTM C871 ASTM C518 (C177): R-Value / inch @ 75°F - 4.1 hr. ft2 .°F/BTU ASTM C1104/C1104M: Water Absorption/Vapor Sorption - < 1 % Weight ASTM C612: Complies with Type IVB US Coast Guard Certificate of Approval: 164.107/16/0, 164.107/17/0, 164.109/26/0, 164.112/142/0ASTM C177, ASTM C411, ASTM C356, ASTM E84, ASTM C303, ASTM C692, ASTM C665, ASTM C795, ASTM C871, ASTM C518 , ASTM C1104, ASTM C612, ASTM C 177, ASTM C 411, ASTM C 356, ASTM E 84, ASTM C 303, ASTM C 692, ASTM C 665, ASTM C 795, ASTM C 871, ASTM C 518 , ASTM C 1104, ASTM C 612, ASTM C-177, ASTM C-411, ASTM C-356, ASTM E-84, ASTM C-303, ASTM C-692, ASTM C-665, ASTM C-795, ASTM C-871, ASTM C-518 , ASTM C-1104, ASTM C-612sdsmarine-insulation
RockwoolROCKWOOL SeaRox SL 648 NA Series Marine Insulation BoardASTM C117: @ 75 F: 0.24 Btu.in/hr.ft2 ASTM C411: Hot surface performnace: 1200°F- (650°C) ASTM E136/CAN4 S114: Non combustible ASTM C356: Linear Shrinkage: ≤ 1 % at 1200°F - (650°C) ASTM E84 (UL 723): Flame spread index = 0 ; Smoke development index = 0 CAN/ULC S102: Flame spread index = 0 ; Smoke development index = 0 ASTM C303: Actual Density = 8 lb/ft³ - (128 kg/m³) ASTM C692: Stress Corrosion Cracking Tendency of Austenitic Stainless Steel = Passed ASTM C665: Corrosion of Steel = Passed ASTM C795 / ASTM C871 ASTM C518 (C177): R-Value / inch @ 75°F - 4.1 hr. ft2 .°F/BTU ASTM C1104/C1104M: Water Absorption/Vapor Sorption - < 1 % Weight ASTM C612: Complies with Type IVB US Coast Guard Certificate of Approval: 164.107/16/0, 164.107/17/0, 164.109/26/0, 164.112/142/0ASTM C177, ASTM C411, ASTM C356, ASTM E84, ASTM C303, ASTM C692, ASTM C665, ASTM C795, ASTM C871, ASTM C518 , ASTM C1104, ASTM C612, ASTM C 177, ASTM C 411, ASTM C 356, ASTM E 84, ASTM C 303, ASTM C 692, ASTM C 665, ASTM C 795, ASTM C 871, ASTM C 518 , ASTM C 1104, ASTM C 612, ASTM C-177, ASTM C-411, ASTM C-356, ASTM E-84, ASTM C-303, ASTM C-692, ASTM C-665, ASTM C-795, ASTM C-871, ASTM C-518 , ASTM C-1104, ASTM C-612tdsmarine-insulation
RockwoolROCKWOOL SeaRox SL 648 NA Series Marine Insulation BoardASTM C117: @ 75 F: 0.24 Btu.in/hr.ft2 ASTM C411: Hot surface performnace: 1200°F- (650°C) ASTM E136/CAN4 S114: Non combustible ASTM C356: Linear Shrinkage: ≤ 1 % at 1200°F - (650°C) ASTM E84 (UL 723): Flame spread index = 0 ; Smoke development index = 0 CAN/ULC S102: Flame spread index = 0 ; Smoke development index = 0 ASTM C303: Actual Density = 8 lb/ft³ - (128 kg/m³) ASTM C692: Stress Corrosion Cracking Tendency of Austenitic Stainless Steel = Passed ASTM C665: Corrosion of Steel = Passed ASTM C795 / ASTM C871 ASTM C518 (C177): R-Value / inch @ 75°F - 4.1 hr. ft2 .°F/BTU ASTM C1104/C1104M: Water Absorption/Vapor Sorption - < 1 % Weight ASTM C612: Complies with Type IVB US Coast Guard Certificate of Approval: 164.107/16/0, 164.107/17/0, 164.109/26/0, 164.112/142/0ASTM C177, ASTM C411, ASTM C356, ASTM E84, ASTM C303, ASTM C692, ASTM C665, ASTM C795, ASTM C871, ASTM C518 , ASTM C1104, ASTM C612, ASTM C 177, ASTM C 411, ASTM C 356, ASTM E 84, ASTM C 303, ASTM C 692, ASTM C 665, ASTM C 795, ASTM C 871, ASTM C 518 , ASTM C 1104, ASTM C 612, ASTM C-177, ASTM C-411, ASTM C-356, ASTM E-84, ASTM C-303, ASTM C-692, ASTM C-665, ASTM C-795, ASTM C-871, ASTM C-518 , ASTM C-1104, ASTM C-612sdsmarine-insulation
RockwoolROCKWOOL SeaRox SL 658 NA Series Marine Insulation BoardASTM C117: @ 75 F: 0.24 Btu.in/hr.ft2 ASTM C411: Hot surface performnace: 1200°F- (650°C) ASTM E136/CAN4 S114: Non combustible ASTM C356: Linear Shrinkage: ≤ 1 % at 1200°F - (650°C) ASTM E84 (UL 723): Flame spread index = 0 ; Smoke development index = 0 CAN/ULC S102: Flame spread index = 0 ; Smoke development index = 0 ASTM C303: Actual Density = 10 lb/ft³ - (160 kg/m³) ASTM C692: Stress Corrosion Cracking Tendency of Austenitic Stainless Steel = Passed ASTM C665: Corrosion of Steel = Passed ASTM C795 / ASTM C871 ASTM C518 (C177): R-Value / inch @ 75°F - 4.1 hr. ft2 .°F/BTU ASTM C1104/C1104M: Water Absorption/Vapor Sorption - < 1 % Weight ASTM C612: Complies with Type IVB US Coast Guard Certificate of Approval: 164.107/16/0, 164.107/17/0, 164.109/26/0, 164.112/142/0ASTM C177, ASTM C411, ASTM C356, ASTM E84, ASTM C303, ASTM C692, ASTM C665, ASTM C795, ASTM C871, ASTM C518 , ASTM C1104, ASTM C612, ASTM C 177, ASTM C 411, ASTM C 356, ASTM E 84, ASTM C 303, ASTM C 692, ASTM C 665, ASTM C 795, ASTM C 871, ASTM C 518 , ASTM C 1104, ASTM C 612, ASTM C-177, ASTM C-411, ASTM C-356, ASTM E-84, ASTM C-303, ASTM C-692, ASTM C-665, ASTM C-795, ASTM C-871, ASTM C-518 , ASTM C-1104, ASTM C-612tdsmarine-insulation
RockwoolROCKWOOL SeaRox SL 658 NA Series Marine Insulation BoardASTM C117: @ 75 F: 0.24 Btu.in/hr.ft2 ASTM C411: Hot surface performnace: 1200°F- (650°C) ASTM E136/CAN4 S114: Non combustible ASTM C356: Linear Shrinkage: ≤ 1 % at 1200°F - (650°C) ASTM E84 (UL 723): Flame spread index = 0 ; Smoke development index = 0 CAN/ULC S102: Flame spread index = 0 ; Smoke development index = 0 ASTM C303: Actual Density = 10 lb/ft³ - (160 kg/m³) ASTM C692: Stress Corrosion Cracking Tendency of Austenitic Stainless Steel = Passed ASTM C665: Corrosion of Steel = Passed ASTM C795 / ASTM C871 ASTM C518 (C177): R-Value / inch @ 75°F - 4.1 hr. ft2 .°F/BTU ASTM C1104/C1104M: Water Absorption/Vapor Sorption - < 1 % Weight ASTM C612: Complies with Type IVB US Coast Guard Certificate of Approval: 164.107/16/0, 164.107/17/0, 164.109/26/0, 164.112/142/0ASTM C177, ASTM C411, ASTM C356, ASTM E84, ASTM C303, ASTM C692, ASTM C665, ASTM C795, ASTM C871, ASTM C518 , ASTM C1104, ASTM C612, ASTM C 177, ASTM C 411, ASTM C 356, ASTM E 84, ASTM C 303, ASTM C 692, ASTM C 665, ASTM C 795, ASTM C 871, ASTM C 518 , ASTM C 1104, ASTM C 612, ASTM C-177, ASTM C-411, ASTM C-356, ASTM E-84, ASTM C-303, ASTM C-692, ASTM C-665, ASTM C-795, ASTM C-871, ASTM C-518 , ASTM C-1104, ASTM C-612sdsmarine-insulation
RockwoolROCKWOOL SeaRox SL 720 Marine Insulation BoardsEN 12667: 0,036 λ (W/mK)@ 10 °C EN 1602 / IMO - Nominal density: 32 kg/m³ Acc. IMO FTP code: Non-combustible, Low Flame-Spread Properties EN 1609 AC - Water absorption (short term) - < 1 kg/m2 ISO 354 (approximated)- sound absorption: αW = 0,75, thickness 50 mmtdsmarine-insulation
RockwoolROCKWOOL SeaRox SL 720 Marine Insulation BoardsEN 12667: 0,036 λ (W/mK)@ 10 °C EN 1602 / IMO - Nominal density: 32 kg/m³ Acc. IMO FTP code: Non-combustible, Low Flame-Spread Properties EN 1609 AC - Water absorption (short term) - < 1 kg/m2 ISO 354 (approximated)- sound absorption: αW = 0,75, thickness 50 mmsdsmarine-insulation
RockwoolROCKWOOL SeaRox SL 740 Marine Insulation BoardsEN 12667: 0,034 λ (W/mK)@ 10 °C EN 1602 / IMO - Nominal density: 45 kg/m³ Acc. IMO FTP code: Non-combustible, Low Flame-Spread Properties, Approved for A constructions. EN 1609 AC - Water absorption (short term) - < 1 kg/m2 ISO 354 (approximated)- sound absorption: αW = 0,75, thickness 50 mmtdsmarine-insulation
RockwoolROCKWOOL SeaRox SL 740 Marine Insulation BoardsEN 12667: 0,034 λ (W/mK)@ 10 °C EN 1602 / IMO - Nominal density: 45 kg/m³ Acc. IMO FTP code: Non-combustible, Low Flame-Spread Properties, Approved for A constructions. EN 1609 AC - Water absorption (short term) - < 1 kg/m2 ISO 354 (approximated)- sound absorption: αW = 0,75, thickness 50 mmsdsmarine-insulation
RockwoolROCKWOOL AFB Acoustical Fire Batt Mineral Wool InsulationCAN/ULC S702: Mineral Fiber Thermal Insulation for Buildings, Type 1 Compliant ASTM C665: Mineral Fiber Thermal Insulation for Buildings, Type 1 Compliant ASTM C553: Mineral Fiber Thermal Insulation for Buildings, Type 7 Compliant 338-97-M: MEA Approval, New York City Approval RR 25444: City of Los Angeles Approval ASTM E84 (UL 723): Flame spread index = 0; Smoke developed index = 0 CAN/ULC S102: Flame spread index = 0; Smoke developed index = 0 ASTM E136: Behavior of materials at 750°C - Non-combustible CAN/ULC S129: Smolder Resistance - 0.09% ASTM C303: Actual Density at thicknesses ≥ 3” (76.2 mm) - 2.5 lbs/ft³ (40 kg/m³). ASTM C303: Actual Density at thicknesses < 3” (76.2 mm) - 2.8 lbs/ft³ (45 kg/m³). ASTM C795: Stress Corrosion Cracking Tendency of Austenitic Stainless Steel - Passed ASTM C665: Corrosion of Steel - Passed UL 181: Air erosion - Maximum Air Velocity - 1000 fpm (5.08 m/s) ASTM C423, ASTM E90. Fire Rated Designs: ULC Classification Code: BZJZC UL Classification Code: BZJZASTM C665, ASTM E84, ASTM E136, ASTM C303, ASTM C423, ASTM E90, ASTM C 665, ASTM E 84, ASTM E 136, ASTM C 303, ASTM C 423, ASTM E 90, ASTM C-665, ASTM E-84, ASTM E-136, ASTM C-303, ASTM C-423, ASTM E-90tdsmineral-wool-commercial
RockwoolROCKWOOL AFB Acoustical Fire Batt Mineral Wool InsulationCAN/ULC S702: Mineral Fiber Thermal Insulation for Buildings, Type 1 Compliant ASTM C665: Mineral Fiber Thermal Insulation for Buildings, Type 1 Compliant ASTM C553: Mineral Fiber Thermal Insulation for Buildings, Type 7 Compliant 338-97-M: MEA Approval, New York City Approval RR 25444: City of Los Angeles Approval ASTM E84 (UL 723): Flame spread index = 0; Smoke developed index = 0 CAN/ULC S102: Flame spread index = 0; Smoke developed index = 0 ASTM E136: Behavior of materials at 750°C - Non-combustible CAN/ULC S129: Smolder Resistance - 0.09% ASTM C303: Actual Density at thicknesses ≥ 3” (76.2 mm) - 2.5 lbs/ft³ (40 kg/m³). ASTM C303: Actual Density at thicknesses < 3” (76.2 mm) - 2.8 lbs/ft³ (45 kg/m³). ASTM C795: Stress Corrosion Cracking Tendency of Austenitic Stainless Steel - Passed ASTM C665: Corrosion of Steel - Passed UL 181: Air erosion - Maximum Air Velocity - 1000 fpm (5.08 m/s) ASTM C423, ASTM E90. Fire Rated Designs: ULC Classification Code: BZJZC UL Classification Code: BZJZASTM C665, ASTM E84, ASTM E136, ASTM C303, ASTM C423, ASTM E90, ASTM C 665, ASTM E 84, ASTM E 136, ASTM C 303, ASTM C 423, ASTM E 90, ASTM C-665, ASTM E-84, ASTM E-136, ASTM C-303, ASTM C-423, ASTM E-90sdsmineral-wool-commercial
RockwoolROCKWOOL AFB evo Acoustical Fire Batt Mineral Wool InsulationCAN/ULC S702: Mineral Fiber Thermal Insulation for Buildings, Type 1 Compliant ASTM C665: Mineral Fiber Thermal Insulation for Buildings, Type 1 Compliant ASTM E84 (UL 723): Flame spread index = 0; Smoke developed index = 0 CAN/ULC S102: Flame spread index = 0; Smoke developed index = 0 CAN/ULC S114: Determination of non-combustibility of building materials - Non Combustible ASTM E136: Behavior of materials at 750°C - Non-combustible ASTM C303: Actual Density at thicknesses ≥ 3” (76.2 mm) - 2.5 lbs/ft³ (40 kg/m³). ASTM C303: Actual Density at thicknesses < 3” (76.2 mm) - 2.8 lbs/ft³ (45 kg/m³). ASTM C665: Corrosion of Steel - Passed ASTM C423, ASTM E90. Fire Rated Designs: ULC Classification Code: BZJZC UL Classification Code: BZJZASTM C665, ASTM E84, ASTM E136, ASTM C303, ASTM C665, ASTM C423, ASTM E90, ASTM C 665, ASTM E 84, ASTM E 136, ASTM C 303, ASTM C 665, ASTM C 423, ASTM E 90, ASTM C-665, ASTM E-84, ASTM E-136, ASTM C-303, ASTM C-665, ASTM C-423, ASTM E-90tdsmineral-wool-commercial
RockwoolROCKWOOL AFB evo Acoustical Fire Batt Mineral Wool InsulationCAN/ULC S702: Mineral Fiber Thermal Insulation for Buildings, Type 1 Compliant ASTM C665: Mineral Fiber Thermal Insulation for Buildings, Type 1 Compliant ASTM E84 (UL 723): Flame spread index = 0; Smoke developed index = 0 CAN/ULC S102: Flame spread index = 0; Smoke developed index = 0 CAN/ULC S114: Determination of non-combustibility of building materials - Non Combustible ASTM E136: Behavior of materials at 750°C - Non-combustible ASTM C303: Actual Density at thicknesses ≥ 3” (76.2 mm) - 2.5 lbs/ft³ (40 kg/m³). ASTM C303: Actual Density at thicknesses < 3” (76.2 mm) - 2.8 lbs/ft³ (45 kg/m³). ASTM C665: Corrosion of Steel - Passed ASTM C423, ASTM E90. Fire Rated Designs: ULC Classification Code: BZJZC UL Classification Code: BZJZASTM C665, ASTM E84, ASTM E136, ASTM C303, ASTM C665, ASTM C423, ASTM E90, ASTM C 665, ASTM E 84, ASTM E 136, ASTM C 303, ASTM C 665, ASTM C 423, ASTM E 90, ASTM C-665, ASTM E-84, ASTM E-136, ASTM C-303, ASTM C-665, ASTM C-423, ASTM E-90sdsmineral-wool-commercial
RockwoolROCKWOOL Cavityrock Black Insulation BoardCavityrock® Black achieves a flame spread (FS) index of 10 and smoke development (SD) index of 25, per ASTM E84, and a FS of 10 and SD of 10 when tested under CAN/ULC S102ASTM E84, ASTM E 84, ASTM E-84sdsmineral-wool-commercial
RockwoolROCKWOOL Cavityrock Black Insulation BoardCavityrock® Black achieves a flame spread (FS) index of 10 and smoke development (SD) index of 25, per ASTM E84, and a FS of 10 and SD of 10 when tested under CAN/ULC S102ASTM E84, ASTM E 84, ASTM E-84tdsmineral-wool-commercial
RockwoolROCKWOOL Comfortbatt Thermal Batt InsulationASTM C665: Mineral Fiber Thermal Insulation for Buildings, Type 1 Compliant ASTM E84 (UL 723): Flame spread index = 0; Smoke developed index = 0 ASTM E136: Behavior of materials at 750°C - Non-combustible ASTM C167: Density > 2lbs/ft3 (> 32Kg/m3) ASTM C518ASTM C665, ASTM E84, ASTM E136, ASTM C167, ASTM C518, ASTM C 665, ASTM E 84, ASTM E 136, ASTM C 167, ASTM C 518, ASTM C-665, ASTM E-84, ASTM E-136, ASTM C-167, ASTM C-518tdsmineral-wool-commercial
RockwoolROCKWOOL Comfortbatt Thermal Batt InsulationASTM C665: Mineral Fiber Thermal Insulation for Buildings, Type 1 Compliant ASTM E84 (UL 723): Flame spread index = 0; Smoke developed index = 0 ASTM E136: Behavior of materials at 750°C - Non-combustible ASTM C167: Density > 2lbs/ft3 (> 32Kg/m3) ASTM C518ASTM C665, ASTM E84, ASTM E136, ASTM C167, ASTM C518, ASTM C 665, ASTM E 84, ASTM E 136, ASTM C 167, ASTM C 518, ASTM C-665, ASTM E-84, ASTM E-136, ASTM C-167, ASTM C-518sdsmineral-wool-commercial
RockwoolROCKWOOL Fabrock BattASTM C612: Mineral Fiber Block and Board Thermal Insulation - Type IVB Compliant. ASTM E84 (UL 723): Flame spread index = 0; Smoke developed index = 0 CAN/ULC S102: Flame spread index = 0; Smoke developed index = 0 CAN/ULC S114: Determination of non-combustibility of building materials - Non Combustible ASTM E136: Behavior of materials at 750°C - Non-combustible CAN/ULC S129: Smolder Resistance - 0.09% ASTM C303: Actual Density 2.8 lb/ft3 (45 Kg/m3) ASTM C795: Stress Corrosion Cracking Tendency of Austenitic Stainless Steel - Passed ASTM C665: Corrosion of Steel - Passed ASTM C518 (C177): R-Value / inch @ 75°F - 4.0 hr. ft^{2} .°F/BTU ASTM C1104: Moisture Sorption by weight - < 1 % Weight ASTM C1338: Determination of Fungi Resistance - Passed ASTM C165: 418psf (20kPa) @ 10% compression, 877psf (42kPa) @ 25% compression ASTM C423ASTM C612, ASTM E84, ASTM E136, ASTM C303, ASTM C795, ASTM C665, ASTM C518, ASTM C1104, ASTM C1338, ASTM C165, ASTM C423, ASTM C 612, ASTM E 84, ASTM E 136, ASTM C 303, ASTM C 795, ASTM C 665, ASTM C 518, ASTM C 1104, ASTM C 1338, ASTM C 165, ASTM C 423, ASTM C-612, ASTM E-84, ASTM E-136, ASTM C-303, ASTM C-795, ASTM C-665, ASTM C-518, ASTM C-1104, ASTM C-1338, ASTM C-165, ASTM C-423tdsoem
RockwoolROCKWOOL Fabrock BattASTM C612: Mineral Fiber Block and Board Thermal Insulation - Type IVB Compliant. ASTM E84 (UL 723): Flame spread index = 0; Smoke developed index = 0 CAN/ULC S102: Flame spread index = 0; Smoke developed index = 0 CAN/ULC S114: Determination of non-combustibility of building materials - Non Combustible ASTM E136: Behavior of materials at 750°C - Non-combustible CAN/ULC S129: Smolder Resistance - 0.09% ASTM C303: Actual Density 2.8 lb/ft3 (45 Kg/m3) ASTM C795: Stress Corrosion Cracking Tendency of Austenitic Stainless Steel - Passed ASTM C665: Corrosion of Steel - Passed ASTM C518 (C177): R-Value / inch @ 75°F - 4.0 hr. ft^{2} .°F/BTU ASTM C1104: Moisture Sorption by weight - < 1 % Weight ASTM C1338: Determination of Fungi Resistance - Passed ASTM C165: 418psf (20kPa) @ 10% compression, 877psf (42kPa) @ 25% compression ASTM C423ASTM C612, ASTM E84, ASTM E136, ASTM C303, ASTM C795, ASTM C665, ASTM C518, ASTM C1104, ASTM C1338, ASTM C165, ASTM C423, ASTM C 612, ASTM E 84, ASTM E 136, ASTM C 303, ASTM C 795, ASTM C 665, ASTM C 518, ASTM C 1104, ASTM C 1338, ASTM C 165, ASTM C 423, ASTM C-612, ASTM E-84, ASTM E-136, ASTM C-303, ASTM C-795, ASTM C-665, ASTM C-518, ASTM C-1104, ASTM C-1338, ASTM C-165, ASTM C-423sdsoem
RockwoolROCKWOOL Plus MB – Metal Building InsulationASTM C553: Mineral Fiber Blanket Thermal Insulation, Type I, II, and III ASTM E84 (UL 723): Flame spread index = 0; Smoke developed index = 0 CAN/ULC S102: Flame spread index = 0; Smoke developed index = 0 CAN/ULC S114: Determination of non-combustibility of building materials - Non Combustible ASTM E136: Behavior of materials at 750°C - Non-combustible ASTM C303: Actual Density 2.0 lb/ft3 (32 Kg/m3) ASTM C795: Stress Corrosion Cracking Tendency of Austenitic Stainless Steel - Passed ASTM C665: Corrosion of Steel - Passed ASTM C518 (C177): R-Value / inch @ 75°F - 4.0 hr. ft2 .°F/BTU ASTM C1104: Moisture Sorption - 0.03% ASTM C1338: Determination of Fungi Resistance - Passed ASTM C423ASTM C612, ASTM C665, ASTM E84, ASTM E136, ASTM C167, ASTM C423, ASTM C 612, ASTM C 665, ASTM E 84, ASTM E 136, ASTM C 167, ASTM C 423, ASTM C-612, ASTM C-665, ASTM E-84, ASTM E-136, ASTM C-167, ASTM C-423tdsmetal-building-insulation
RockwoolROCKWOOL Plus MB – Metal Building InsulationASTM C553: Mineral Fiber Blanket Thermal Insulation, Type I, II, and III ASTM E84 (UL 723): Flame spread index = 0; Smoke developed index = 0 CAN/ULC S102: Flame spread index = 0; Smoke developed index = 0 CAN/ULC S114: Determination of non-combustibility of building materials - Non Combustible ASTM E136: Behavior of materials at 750°C - Non-combustible ASTM C303: Actual Density 2.0 lb/ft3 (32 Kg/m3) ASTM C795: Stress Corrosion Cracking Tendency of Austenitic Stainless Steel - Passed ASTM C665: Corrosion of Steel - Passed ASTM C518 (C177): R-Value / inch @ 75°F - 4.0 hr. ft2 .°F/BTU ASTM C1104: Moisture Sorption - 0.03% ASTM C1338: Determination of Fungi Resistance - Passed ASTM C423ASTM C612, ASTM C665, ASTM E84, ASTM E136, ASTM C167, ASTM C423, ASTM C 612, ASTM C 665, ASTM E 84, ASTM E 136, ASTM C 167, ASTM C 423, ASTM C-612, ASTM C-665, ASTM E-84, ASTM E-136, ASTM C-167, ASTM C-423sdsmetal-building-insulation
RockwoolROCKWOOL ProRox PS 680 with FR-TechMaximum use temperature 1,400°F (760°C) ASTM C447 Sag resistance ≤ 2% at 1,400°F (760°C) ASTM C411 Linear shrinkage ≤ 1% at 1,400°F (760°C) ASTM C356 Surface burning characteristics Flame spread index = 25; Smoke development index = 50 ASTM E84 Corrosion resistance Evaluation on external stress corrosion cracking tendency of austenitic stainless steel = Passed Chemical analysis for Cl- , Fl- , Na+ , SiO4 4-: Results fall within acceptability limits of ASTM C795 Trace quantity of water leachable chloride ions: ≤ 10 ppm ASTM C692 / ASTM C795 ASTM C871 / ASTM C795 EN 13468 Water absorption ≤ 0.04 lb/ft² (≤ 0.2 kg/m²) ≤ 0.04 lb/ft² (≤ 0.2 kg/m²) (After 24 hrs. pre-heating at 482°F (250°C)) EN 13472 Vapor sorption < 1% Weight ASTM C1104, ASTM C335, ASTM C547.ASTM C447, ASTM C411, ASTM C356, ASTM E84, ASTM C795, ASTM C692, ASTM C871, ASTM C1104, ASTM C335, ASTM C547. ASTM C 447, ASTM C 411, ASTM C 356, ASTM E 84, ASTM C 795, ASTM C 692, ASTM C 871, ASTM C 1104, ASTM C 335, ASTM C 547. ASTM C-447, ASTM C-411, ASTM C-356, ASTM E-84, ASTM C-795, ASTM C-692, ASTM C-871, ASTM C-1104, ASTM C-335, ASTM C-547. tdsmineral-wool-industrial
RockwoolROCKWOOL ProRox PS 680 with FR-TechMaximum use temperature 1,400°F (760°C) ASTM C447 Sag resistance ≤ 2% at 1,400°F (760°C) ASTM C411 Linear shrinkage ≤ 1% at 1,400°F (760°C) ASTM C356 Surface burning characteristics Flame spread index = 25; Smoke development index = 50 ASTM E84 Corrosion resistance Evaluation on external stress corrosion cracking tendency of austenitic stainless steel = Passed Chemical analysis for Cl- , Fl- , Na+ , SiO4 4-: Results fall within acceptability limits of ASTM C795 Trace quantity of water leachable chloride ions: ≤ 10 ppm ASTM C692 / ASTM C795 ASTM C871 / ASTM C795 EN 13468 Water absorption ≤ 0.04 lb/ft² (≤ 0.2 kg/m²) ≤ 0.04 lb/ft² (≤ 0.2 kg/m²) (After 24 hrs. pre-heating at 482°F (250°C)) EN 13472 Vapor sorption < 1% Weight ASTM C1104, ASTM C335, ASTM C547.ASTM C447, ASTM C411, ASTM C356, ASTM E84, ASTM C795, ASTM C692, ASTM C871, ASTM C1104, ASTM C335, ASTM C547. ASTM C 447, ASTM C 411, ASTM C 356, ASTM E 84, ASTM C 795, ASTM C 692, ASTM C 871, ASTM C 1104, ASTM C 335, ASTM C 547. ASTM C-447, ASTM C-411, ASTM C-356, ASTM E-84, ASTM C-795, ASTM C-692, ASTM C-871, ASTM C-1104, ASTM C-335, ASTM C-547.sdsmineral-wool-industrial
RockwoolROCKWOOL Safe’n’Sound Fire and Soundproofing InsulationASTM C665: Mineral Fiber Blanket Thermal Insulation, Type 1 Compliant CAN/ULC S702: Mineral Fiber Thermal Insulation for Buildings, Type 1 Compliant ASTM E84 (UL 723): Flame spread index = 0; Smoke developed index = 0 CAN/ULC S102: Flame spread index = 0; Smoke developed index = 0 CAN/ULC S114: Determination of non-combustibility of building materials - Non Combustible ASTM E136: Behavior of materials at 750°C - Non-combustible CAN/ULC S129: Smolder resistance - 0.09% ASTM C167: Actual density - 2.5 lb/ft3 (40 Kg/m3) ASTM C423ASTM C665, ASTM E84, ASTM E136, ASTM C167, ASTM C423, ASTM C 665, ASTM E 84, ASTM E 136, ASTM C 167, ASTM C 423, ASTM C-665, ASTM E-84, ASTM E-136, ASTM C-167, ASTM C-423tdsmineral-wool-commercial
RockwoolROCKWOOL Safe’n’Sound Fire and Soundproofing InsulationASTM C665: Mineral Fiber Blanket Thermal Insulation, Type 1 Compliant CAN/ULC S702: Mineral Fiber Thermal Insulation for Buildings, Type 1 Compliant ASTM E84 (UL 723): Flame spread index = 0; Smoke developed index = 0 CAN/ULC S102: Flame spread index = 0; Smoke developed index = 0 CAN/ULC S114: Determination of non-combustibility of building materials - Non Combustible ASTM E136: Behavior of materials at 750°C - Non-combustible CAN/ULC S129: Smolder resistance - 0.09% ASTM C167: Actual density - 2.5 lb/ft3 (40 Kg/m3) ASTM C423ASTM C665, ASTM E84, ASTM E136, ASTM C167, ASTM C423, ASTM C 665, ASTM E 84, ASTM E 136, ASTM C 167, ASTM C 423, ASTM C-665, ASTM E-84, ASTM E-136, ASTM C-167, ASTM C-423sdsmineral-wool-commercial
SpeedlineSpeedline 73-20 RTV Silicone Adhesive/SealantSpecific Gravity @77°F (25°C) ASTM 792 1.04 Durometer Hardness, Shore A ASTM D412 30 Tensile Strength, psi ASTM D412 350 Elongation ASTM D412 500% Brittle Point ASTM D746 –100°F (–73°C), MIL-A-46106A, Amend 2, Type 1. Meets the requirements of FDA Regulation No. 21 CFR 177.2600 subject to end use compliance with limitations. Meets the requirements of USDA for use in Federally inspected meat and poultry plantsASTM 792, ASTM D412, ASTM D746, ASTM 792, ASTM D 412, ASTM D 746, ASTM 792, ASTM D-412, ASTM D-746tdsadhesives-sealants
SpeedlineSpeedline 73-20 RTV Silicone Adhesive/SealantSpecific Gravity @77°F (25°C) ASTM 792 1.04 Durometer Hardness, Shore A ASTM D412 30 Tensile Strength, psi ASTM D412 350 Elongation ASTM D412 500% Brittle Point ASTM D746 –100°F (–73°C), MIL-A-46106A, Amend 2, Type 1. Meets the requirements of FDA Regulation No. 21 CFR 177.2600 subject to end use compliance with limitations. Meets the requirements of USDA for use in Federally inspected meat and poultry plantsASTM 792, ASTM D412, ASTM D746, ASTM 792, ASTM D 412, ASTM D 746, ASTM 792, ASTM D-412, ASTM D-746sdsadhesives-sealants
STISTI SmokeBlock 136 Firestop CaulkDensity/Weight per Gallon 14.3 lb/gal (1.71 kg/L). Solids Content by Weight 63.6%. Solids Content by Volume 38%. Flame Spread* Non-Combustible ASTM E136. Smoke Developement* Non-Combustible ASTM E136. Coverage Penetration. pH 10.5 to 11.5. In Service Temperature 0°F (-18°C) to 300°F (149°C). Storage Temperature 35°F (1.7°C) to 95°F (35°C). Application Temperature 35°F (1.7°C) to 95°F (35°C).ASTM E136. ASTM E 136. ASTM E-136.tdsfirestop
STISTI SmokeBlock 136 Firestop CaulkDensity/Weight per Gallon 14.3 lb/gal (1.71 kg/L). Solids Content by Weight 63.6%. Solids Content by Volume 38%. Flame Spread* Non-Combustible ASTM E136. Smoke Developement* Non-Combustible ASTM E136. Coverage Penetration. pH 10.5 to 11.5. In Service Temperature 0°F (-18°C) to 300°F (149°C). Storage Temperature 35°F (1.7°C) to 95°F (35°C). Application Temperature 35°F (1.7°C) to 95°F (35°C).ASTM E136. ASTM E 136. ASTM E-136.sdsfirestop
STISTI SmokeBlock 200 Fireblocking FoamColor Salmon Red/Pink Density 1.56 lbs/cu ft (24.98 kg/cu m) Flame Spread* 15 Smoke Development* 35 In Service Temperature 40°F (4°C) to 200°F (93°C) Application Temperature 40°F (4°C) to 115°F (46°C) Storage Temperature 40°F (4°C) to 95°F (35°C) Cellular Structure 70% to 80% Closed Cell Tack Free Time (1” Bead) 10 Minutes Shelf Life 12 months.tdsfirestop
STISTI SmokeBlock 200 Fireblocking FoamColor Salmon Red/Pink Density 1.56 lbs/cu ft (24.98 kg/cu m) Flame Spread* 15 Smoke Development* 35 In Service Temperature 40°F (4°C) to 200°F (93°C) Application Temperature 40°F (4°C) to 115°F (46°C) Storage Temperature 40°F (4°C) to 95°F (35°C) Cellular Structure 70% to 80% Closed Cell Tack Free Time (1” Bead) 10 Minutes Shelf Life 12 months.sdsfirestop
STISTI SpecSeal EW E-Wrap Endothermic WrapASTM E1725 - Circuit Integrity - Values 1, 2 Hour, UL1489 - Fuel Oil - Values 1, 2 Hour, ASTM E814/UL1479 - Utility Box - Values 1, 2 Hour.ASTM E1725, UL1489, ASTM E814/UL1479. ASTM E 1725, UL 1489, ASTM E 814/UL 1479. ASTM E-1725, UL-1489, ASTM E-814/UL-1479. sdsfirestop
STISTI SpecSeal EW E-Wrap Endothermic WrapASTM E1725 - Circuit Integrity - Values 1, 2 Hour, UL1489 - Fuel Oil - Values 1, 2 Hour, ASTM E814/UL1479 - Utility Box - Values 1, 2 Hour.ASTM E1725, UL1489, ASTM E814/UL1479. ASTM E 1725, UL 1489, ASTM E 814/UL 1479. ASTM E-1725, UL-1489, ASTM E-814/UL-1479. tdsfirestop
STISTI WF300 Intumescent Firestop CaulkIn Service Temperature Less than 185°F (85°C). Density/Weight per Gallon 10.2 lbs/gal (1.22 kg/L). Storage Temperature 40°F (4°C) to 95°F (35°C). Solids Content by Weight 81%. Application Temperature 35°F (2°C) to 100°F (38°C). Solids Content by Volume 77.6%. STC Rating (ASTM E90-04/ASTM C919) 61 (Relates to Specific Construction). Flame Spread* 0. VOC Content** 53 g/L. Smoke Development* 20. Expansion Begins 350°F (176°C). Average Volume Shrinkage (ASTM C1241) 23.5%. Volume Expansion 5x free expansion. pH 7.4 to 8.4. Shelf Life From Date of Manufacture 24 months.ASTM E90-04/ASTM C919, ASTM C1241, ASTM E814 (ANSI/UL1479), CAN/ULC-S115, ASTM E119 (ANSI/UL263). ASTM E 90-04/ASTM C 919, ASTM C 1241, ASTM E 814 (ANSI/UL1479), CAN/ULC S115, ASTM E 119 (ANSI/UL 263). ASTM E-90-04/ASTM C-919, ASTM C-1241, ASTM E-814 (ANSI/UL-1479), CAN/ULC S-115, ASTM E-119 (ANSI/UL-263)tdsfirestop
STISTI WF300 Intumescent Firestop CaulkIn Service Temperature Less than 185°F (85°C). Density/Weight per Gallon 10.2 lbs/gal (1.22 kg/L). Storage Temperature 40°F (4°C) to 95°F (35°C). Solids Content by Weight 81%. Application Temperature 35°F (2°C) to 100°F (38°C). Solids Content by Volume 77.6%. STC Rating (ASTM E90-04/ASTM C919) 61 (Relates to Specific Construction). Flame Spread* 0. VOC Content** 53 g/L. Smoke Development* 20. Expansion Begins 350°F (176°C). Average Volume Shrinkage (ASTM C1241) 23.5%. Volume Expansion 5x free expansion. pH 7.4 to 8.4. Shelf Life From Date of Manufacture 24 months.ASTM E90-04/ASTM C919, ASTM C1241, ASTM E814 (ANSI/UL1479), CAN/ULC-S115, ASTM E119 (ANSI/UL263). ASTM E 90-04/ASTM C 919, ASTM C 1241, ASTM E 814 (ANSI/UL1479), CAN/ULC S115, ASTM E 119 (ANSI/UL 263). ASTM E-90-04/ASTM C-919, ASTM C-1241, ASTM E-814 (ANSI/UL-1479), CAN/ULC S-115, ASTM E-119 (ANSI/UL-263)sdsfirestop
DAP Foam Inc.Touch ‘n Seal Foam Kit 1000Foam Kit 1000: 1000 board feet ( 92.9 m2 @ 25 mm). Tack Free Time 30 – 60 seconds. Fully Cured Approximately 1 hour. Cuttable 2 – 5 minutes. ASTM G21 Fungi Resistance: Does not support growth. ASTM E-84 Surface Burning Characteristics @ 2” (51 mm): Flame Spread: 10 Smoke Development: 250. ASTM E-90 Sound Transmission Class: .33 @ 1½ in. (38mm). ASTM E-96 Water Vapor Transmission 5.4 perms @ 1 in. (25 mm). ASTM E-283 Air Leakage: 1.57 psf (25 mpf): 0.003 cfm/sq ft. 6.24 psf (50 mpf): 6.24 psf (50 mpf). ASTM C423 Noise Transmission Coefficient: .35. ASTM C-518 R-Value – Initial / Aged 4.96 / 4.1 / in. (25 mm). ASTM D-1622 Density (core) 1.0 – 1.25 pcf/16.0 – 20.0 kg/m3. ASTM D-2856 Closed Cell Content < 10%. ASTM D-6226 Open Cell Content > 90%. • ASTM G21 Fungi Resistance • ASTM E84 Surface Burning Characteristics • ASTM E90 Sound Transmission Class • ASTM E96 Water Vapor Transmission • ASTM E283 Air Leakage • ASTM C423 Noise Reduction Coefficient • ASTM C518 R-Value • ASTM D1622 Density • ASTM D2856 Closed Cell Content • ASTM D6226 Open Cell Content.ASTM G21, ASTM E84, ASTM E90, ASTM E96, ASTM E283, ASTM C423, ASTM C518, ASTM D1622, ASTM D2856, ASTM D6226, ASTM G 21, ASTM E 84, ASTM E 90, ASTM E 96, ASTM E 283, ASTM C 423, ASTM C 518, ASTM D 1622, ASTM D 2856, ASTM D 6226, ASTM G-21, ASTM E-84, ASTM E-90, ASTM E-96, ASTM E-283, ASTM C-423, ASTM C-518, ASTM D-1622, ASTM D-2856, ASTM D-6226tdspolyurethane-foam
DAP Foam, Inc.Touch ‘n Seal Foam Kit 1000Foam Kit 1000: 1000 board feet ( 92.9 m2 @ 25 mm). Tack Free Time 30 – 60 seconds. Fully Cured Approximately 1 hour. Cuttable 2 – 5 minutes. ASTM G21 Fungi Resistance: Does not support growth. ASTM E-84 Surface Burning Characteristics @ 2” (51 mm): Flame Spread: 10 Smoke Development: 250. ASTM E-90 Sound Transmission Class: .33 @ 1½ in. (38mm). ASTM E-96 Water Vapor Transmission 5.4 perms @ 1 in. (25 mm). ASTM E-283 Air Leakage: 1.57 psf (25 mpf): 0.003 cfm/sq ft. 6.24 psf (50 mpf): 6.24 psf (50 mpf). ASTM C423 Noise Transmission Coefficient: .35. ASTM C-518 R-Value – Initial / Aged 4.96 / 4.1 / in. (25 mm). ASTM D-1622 Density (core) 1.0 – 1.25 pcf/16.0 – 20.0 kg/m3. ASTM D-2856 Closed Cell Content < 10%. ASTM D-6226 Open Cell Content > 90%. • ASTM G21 Fungi Resistance • ASTM E84 Surface Burning Characteristics • ASTM E90 Sound Transmission Class • ASTM E96 Water Vapor Transmission • ASTM E283 Air Leakage • ASTM C423 Noise Reduction Coefficient • ASTM C518 R-Value • ASTM D1622 Density • ASTM D2856 Closed Cell Content • ASTM D6226 Open Cell ContentASTM G21, ASTM E84, ASTM E90, ASTM E96, ASTM E283, ASTM C423, ASTM C518, ASTM D1622, ASTM D2856, ASTM D6226, ASTM G 21, ASTM E 84, ASTM E 90, ASTM E 96, ASTM E 283, ASTM C 423, ASTM C 518, ASTM D 1622, ASTM D 2856, ASTM D 6226, ASTM G-21, ASTM E-84, ASTM E-90, ASTM E-96, ASTM E-283, ASTM C-423, ASTM C-518, ASTM D-1622, ASTM D-2856, ASTM D-6226sdspolyurethane-foam
DAP Foam, Inc.Touch ‘n Seal Foam Kit 300Foam Kit 300: 300 board feet ( 27.8 m2 @ 25 mm).Tack Free Time 30 – 60 seconds. Fully Cured Approximately 1 hour. Cuttable 2 – 5 minutes. ASTM G21 Fungi Resistance: Does not support growth. ASTM E-84 Surface Burning Characteristics @ 2” (51 mm): Flame Spread: 10 Smoke Development: 250. ASTM E-90 Sound Transmission Class: .33 @ 1½ in. (38mm). ASTM E-96 Water Vapor Transmission 5.4 perms @ 1 in. (25 mm). ASTM E-283 Air Leakage: 1.57 psf (25 mpf): 0.003 cfm/sq ft. 6.24 psf (50 mpf): 6.24 psf (50 mpf). ASTM C423 Noise Transmission Coefficient: .35. ASTM C-518 R-Value – Initial / Aged 4.96 / 4.1 / in. (25 mm). ASTM D-1622 Density (core) 1.0 – 1.25 pcf/16.0 – 20.0 kg/m3. ASTM D-2856 Closed Cell Content < 10%. ASTM D-6226 Open Cell Content > 90%. • ASTM G21 Fungi Resistance • ASTM E84 Surface Burning Characteristics • ASTM E90 Sound Transmission Class • ASTM E96 Water Vapor Transmission • ASTM E283 Air Leakage • ASTM C423 Noise Reduction Coefficient • ASTM C518 R-Value • ASTM D1622 Density • ASTM D2856 Closed Cell Content • ASTM D6226 Open Cell Content.ASTM G21, ASTM E84, ASTM E90, ASTM E96, ASTM E283, ASTM C423, ASTM C518, ASTM D1622, ASTM D2856, ASTM D6226, ASTM G 21, ASTM E 84, ASTM E 90, ASTM E 96, ASTM E 283, ASTM C 423, ASTM C 518, ASTM D 1622, ASTM D 2856, ASTM D 6226, ASTM G-21, ASTM E-84, ASTM E-90, ASTM E-96, ASTM E-283, ASTM C-423, ASTM C-518, ASTM D-1622, ASTM D-2856, ASTM D-6226tdspolyurethane-foam
DAP Foam, Inc.Touch ‘n Seal Foam Kit 300Foam Kit 300: 300 board feet ( 27.8 m2 @ 25 mm).Tack Free Time 30 – 60 seconds. Fully Cured Approximately 1 hour. Cuttable 2 – 5 minutes. ASTM G21 Fungi Resistance: Does not support growth. ASTM E-84 Surface Burning Characteristics @ 2” (51 mm): Flame Spread: 10 Smoke Development: 250. ASTM E-90 Sound Transmission Class: .33 @ 1½ in. (38mm). ASTM E-96 Water Vapor Transmission 5.4 perms @ 1 in. (25 mm). ASTM E-283 Air Leakage: 1.57 psf (25 mpf): 0.003 cfm/sq ft. 6.24 psf (50 mpf): 6.24 psf (50 mpf). ASTM C423 Noise Transmission Coefficient: .35. ASTM C-518 R-Value – Initial / Aged 4.96 / 4.1 / in. (25 mm). ASTM D-1622 Density (core) 1.0 – 1.25 pcf/16.0 – 20.0 kg/m3. ASTM D-2856 Closed Cell Content < 10%. ASTM D-6226 Open Cell Content > 90%. • ASTM G21 Fungi Resistance • ASTM E84 Surface Burning Characteristics • ASTM E90 Sound Transmission Class • ASTM E96 Water Vapor Transmission • ASTM E283 Air Leakage • ASTM C423 Noise Reduction Coefficient • ASTM C518 R-Value • ASTM D1622 Density • ASTM D2856 Closed Cell Content • ASTM D6226 Open Cell Content.ASTM G21, ASTM E84, ASTM E90, ASTM E96, ASTM E283, ASTM C423, ASTM C518, ASTM D1622, ASTM D2856, ASTM D6226, ASTM G 21, ASTM E 84, ASTM E 90, ASTM E 96, ASTM E 283, ASTM C 423, ASTM C 518, ASTM D 1622, ASTM D 2856, ASTM D 6226, ASTM G-21, ASTM E-84, ASTM E-90, ASTM E-96, ASTM E-283, ASTM C-423, ASTM C-518, ASTM D-1622, ASTM D-2856, ASTM D-6226sdspolyurethane-foam
UnifraxUnifrax FyreWrap® 0.5 Plenum Insulation•Intertek Laboratories (OPL) Listed Applied Fire Protection, File 16341-3 •UL 1887 Passes; Intertek Design Nos. UNI/BI 20-03, UNI/BI 20-04 •Plastic Pipe and Cable Sheathing PVC, CPVC, PB, PE, PP, PVDF and ABS •Plastic Pipe Size (minimum) 1" or larger individual pipes or pipe bundles •Plastic Coated Cable Groupings 3 or more multi-stranded telecommunication wires •ASTM E136 Non-combustibility Passes •ASTM E84, UL 723, ULC S102.2 UL File No. R14514 •Flame Spread Rating: Unfaced Blanket Zero, Encapsulated <25 •Smoke Developed Rating: Unfaced Blanket Zero, Encapsulated <50UL 1887, ASTM E136, ASTM E84, UL 723, ULC S102.2 UL R 14514. UL 1887, ASTM E 136, ASTM E 84, UL723, ULC S 102.2 UL File No. R 14514. UL-1887, ASTM E-136, ASTM E-84, UL-723, ULC S102.2 UL R-14514. tdsfirestop
UnifraxUnifrax FyreWrap® 0.5 Plenum Insulation•Intertek Laboratories (OPL) Listed Applied Fire Protection, File 16341-3 •UL 1887 Passes; Intertek Design Nos. UNI/BI 20-03, UNI/BI 20-04 •Plastic Pipe and Cable Sheathing PVC, CPVC, PB, PE, PP, PVDF and ABS •Plastic Pipe Size (minimum) 1" or larger individual pipes or pipe bundles •Plastic Coated Cable Groupings 3 or more multi-stranded telecommunication wires •ASTM E136 Non-combustibility Passes •ASTM E84, UL 723, ULC S102.2 UL File No. R14514 •Flame Spread Rating: Unfaced Blanket Zero, Encapsulated <25 •Smoke Developed Rating: Unfaced Blanket Zero, Encapsulated <50UL 1887, ASTM E136, ASTM E84, UL 723, ULC S102.2 UL R 14514. UL 1887, ASTM E 136, ASTM E 84, UL723, ULC S 102.2 UL File No. R 14514. UL-1887, ASTM E-136, ASTM E-84, UL-723, ULC S102.2 UL R-14514. sdsfirestop
UnifraxUnifrax FyreWrap® Dryer Protection System (DPS) Insulation•ISO 6944 UL Assembly No. V-32, ULC Assembly No. FRD-29. •UL 1479 (ASTM E814), CAN/ULC S115 UL Assembly Nos. F-C-7057, F-C-7058. •Intertek Laboratories (OPL) Listed Applied Fire Protection, File 16341-3. •ASTM E136 Non combustibility Test Passes. •ASTM E84, UL 723, ULC S102.2 UL File No. R14514. •Flame Spread Rating: Unfaced Blanket: Zero, Encapsulated <25. •Smoke Developed Rating: Unfaced Blanket: Zero, Encapsulated <50.•ISO 6944, UL 1479 (ASTM E814), CAN/ULC S115, ASTM E136, ASTM E84, UL 723, ULC S102.2 UL File No. R14514. •ISO 6944, UL 1479 (ASTM E 814), CAN/ULC S 115, ASTM E 136, ASTM E84, UL723, ULC S 102.2 UL File No. R14514. •ISO 6944, UL-1479 (ASTM E-814), CAN/ULC S-115, ASTM E-136, ASTM E-84, UL-723, ULC S-102.2 UL File No. R-14514. tdsfirestop
UnifraxUnifrax FyreWrap® Dryer Protection System (DPS) Insulation•ISO 6944 UL Assembly No. V-32, ULC Assembly No. FRD-29. •UL 1479 (ASTM E814), CAN/ULC S115 UL Assembly Nos. F-C-7057, F-C-7058. •Intertek Laboratories (OPL) Listed Applied Fire Protection, File 16341-3. •ASTM E136 Non combustibility Test Passes. •ASTM E84, UL 723, ULC S102.2 UL File No. R14514. •Flame Spread Rating: Unfaced Blanket: Zero, Encapsulated <25. •Smoke Developed Rating: Unfaced Blanket: Zero, Encapsulated <50.•ISO 6944, UL 1479 (ASTM E814), CAN/ULC S115, ASTM E136, ASTM E84, UL 723, ULC S102.2 UL File No. R14514. •ISO 6944, UL 1479 (ASTM E 814), CAN/ULC S 115, ASTM E 136, ASTM E84, UL723, ULC S 102.2 UL File No. R14514. •ISO 6944, UL-1479 (ASTM E-814), CAN/ULC S-115, ASTM E-136, ASTM E-84, UL-723, ULC S-102.2 UL File No. R-14514. sdsfirestop
UnifraxUnifrax FyreWrap® Elite® 1.5 Air Distribution System (ADS) Duct Insulation•Intertek Testing Services Design Listings Duct System: UNI/FRD 120-15 •Fire Endurance Rating ISO 6944 – Type A Duct, Stability 2 Hours, Integrity 2 Hours, Insulation 2 Hours •Firestop Test F-rating = 2 hrs. T-rating = 2 hrs. •Per ASTM E814, E119 Firestop System: UNI/FRD 120-21 •UNI/FRD 120-23, UNI/FRD 120-24. •UNI/PHV 120-03, UNI/PHV 120-04. •ASTM E84, UL 723, ULC S102.2 – UL File No. R14514. •Flame Spread Rating: Unfaced Blanket: 0, Encapsulated < 25. •Smoke Developed Rating: Unfaced Blanket: 0, Encapsulated < 50. •ASTM E136 Non-combustibility: Pass. •ASTM C411 Surface Performance: Hot Pass. •ASTM C518 Durability Pass; R-Value = 4.8 per inch @ 75°F. •ASTM C518 Thermal Resistance: R-Value of Elite 1.5 (11⁄2") = 7.2. •ASTM E90 Sound Transmission Class STC = 31 dB. •ASTM D6329-03 Microbial Resistance: Resistant to Mold Growth. •California State Fire Marshal Listing No: 240-1478:100. •New York City Building Bulletin 2018-003.ISO 6944, ASTM E814, E119, ASTM E84, UL 723, ULC S102.2 – UL R14514. ASTM E136, ASTM C411, ASTM C518, ASTM C518, ASTM E90, ASTM D6329-03. ISO 6944, ASTM E 814, E 119, ASTM E 84, UL723, ULC S 102.2 – UL R14514. ASTM E 136, ASTM C 411, ASTM C 518, ASTM C 518, ASTM E 90, ASTM D 6329-03. ISO 6944, ASTM E-814, E119, ASTM E-84, UL-723, ULC S-102.2 – UL R14514. ASTM E-136, ASTM C-411, ASTM C-518, ASTM C-518, ASTM E-90, ASTM D-6329-03.tdsfirestop
UnifraxUnifrax FyreWrap® Elite® 1.5 Air Distribution System (ADS) Duct Insulation•Intertek Testing Services Design Listings Duct System: UNI/FRD 120-15 •Fire Endurance Rating ISO 6944 – Type A Duct, Stability 2 Hours, Integrity 2 Hours, Insulation 2 Hours •Firestop Test F-rating = 2 hrs. T-rating = 2 hrs. •Per ASTM E814, E119 Firestop System: UNI/FRD 120-21 •UNI/FRD 120-23, UNI/FRD 120-24. •UNI/PHV 120-03, UNI/PHV 120-04. •ASTM E84, UL 723, ULC S102.2 – UL File No. R14514. •Flame Spread Rating: Unfaced Blanket: 0, Encapsulated < 25. •Smoke Developed Rating: Unfaced Blanket: 0, Encapsulated < 50. •ASTM E136 Non-combustibility: Pass. •ASTM C411 Surface Performance: Hot Pass. •ASTM C518 Durability Pass; R-Value = 4.8 per inch @ 75°F. •ASTM C518 Thermal Resistance: R-Value of Elite 1.5 (11⁄2") = 7.2. •ASTM E90 Sound Transmission Class STC = 31 dB. •ASTM D6329-03 Microbial Resistance: Resistant to Mold Growth. •California State Fire Marshal Listing No: 240-1478:100. •New York City Building Bulletin 2018-003.ISO 6944, ASTM E814, E119, ASTM E84, UL 723, ULC S102.2 – UL R14514. ASTM E136, ASTM C411, ASTM C518, ASTM C518, ASTM E90, ASTM D6329-03. ISO 6944, ASTM E 814, E 119, ASTM E 84, UL723, ULC S 102.2 – UL R14514. ASTM E 136, ASTM C 411, ASTM C 518, ASTM C 518, ASTM E 90, ASTM D 6329-03. ISO 6944, ASTM E-814, E119, ASTM E-84, UL-723, ULC S-102.2 – UL R14514. ASTM E-136, ASTM C-411, ASTM C-518, ASTM C-518, ASTM E-90, ASTM D-6329-03.sdsfirestop
UnifraxUnifrax FyreWrap® Elite® 1.5 Grease Duct Insulation•ICC Evaluation Services Evaluation Report ESR-2224 •Intertek Laboratories Listed. Duct System: Design No. UNI/BI 120-02, UNI/Bl 120-14, UNI/WA 120-01 •ASTM E2336 Passes all tests •ASTM E2336 Internal Grease Duct Test Zero Clearance to Combustibles at all locations on wrap •ASTM E119 Full Scale Engulfment Test 2-hour Fire Resistance Rating •ASTM E119 Vertical Wall Test 2-hour Fire Resistance Rating •ASTM E84, UL 723, ULC S102.2 – UL File No. R14514, Flame Spread/Smoke Developed Rating, Unfaced Blanket Zero/Zero, Encapsulated <25/<50 •ASTM E814 Firestop Test Firestop System: UNI/FRD 120-19, UNI/BI 120-02, F-Rating = 2 Hrs., T-Rating = 2 Hrs. UNI/BI 120-14 •ASTM E136 Non-Combustibility Test Passes •ASTM C518 Durability Test Passes; R-Value = 4.8 per inch at 75°F •ASTM C518 Thermal Resistance. R-Value of Elite 1.5 (11⁄2") = 7.2 •ASTM D6329-03 Microbial Resistance . Highly Resistant to Mold Growth •California State Fire Marshal Listing No: 2440-1478:100ASTM E2336, ASTM E119, ASTM E84, UL 723, ULC S102.2 – UL File No. R14514, ASTM E814, ASTM E136, ASTM C518, ASTM D6329-03. ASTM E 2336, ASTM E 119, ASTM E 84, UL 723, ULC S102.2 – UL File No. R14514, ASTM E 814, ASTM E 136, ASTM C 518, ASTM D 6329-03. ASTM E-2336, ASTM E-119, ASTM E-84, UL-723, ULC S102.2 – UL File No. R14514, ASTM E-814, ASTM E-136, ASTM C-518, ASTM D-6329-03.tdsfirestop
UnifraxUnifrax FyreWrap® Elite® 1.5 Grease Duct Insulation•ICC Evaluation Services Evaluation Report ESR-2224 •Intertek Laboratories Listed. Duct System: Design No. UNI/BI 120-02, UNI/Bl 120-14, UNI/WA 120-01 •ASTM E2336 Passes all tests •ASTM E2336 Internal Grease Duct Test Zero Clearance to Combustibles at all locations on wrap •ASTM E119 Full Scale Engulfment Test 2-hour Fire Resistance Rating •ASTM E119 Vertical Wall Test 2-hour Fire Resistance Rating •ASTM E84, UL 723, ULC S102.2 – UL File No. R14514, Flame Spread/Smoke Developed Rating, Unfaced Blanket Zero/Zero, Encapsulated <25/<50 •ASTM E814 Firestop Test Firestop System: UNI/FRD 120-19, UNI/BI 120-02, F-Rating = 2 Hrs., T-Rating = 2 Hrs. UNI/BI 120-14 •ASTM E136 Non-Combustibility Test Passes •ASTM C518 Durability Test Passes; R-Value = 4.8 per inch at 75°F •ASTM C518 Thermal Resistance. R-Value of Elite 1.5 (11⁄2") = 7.2 •ASTM D6329-03 Microbial Resistance . Highly Resistant to Mold Growth •California State Fire Marshal Listing No: 2440-1478:100ASTM E2336, ASTM E119, ASTM E84, UL 723, ULC S102.2 – UL File No. R14514, ASTM E814, ASTM E136, ASTM C518, ASTM D6329-03. ASTM E 2336, ASTM E 119, ASTM E 84, UL 723, ULC S102.2 – UL File No. R14514, ASTM E 814, ASTM E 136, ASTM C 518, ASTM D 6329-03. ASTM E-2336, ASTM E-119, ASTM E-84, UL-723, ULC S102.2 – UL File No. R14514, ASTM E-814, ASTM E-136, ASTM C-518, ASTM D-6329-03.sdsfirestop
UnifraxUnifrax FyreWrap® Elite® Blanket Insulation•ASTM E84, UL 723, ULC S102.2 – UL File No. R14514 - Flame Spread/Smoke Developed Rating: Unfaced Blanket Zero/Zero, Encapsulated: <25/<50 •ASTM E136 Non-Combustibility Test: Passes •ASTM C518 Durability Test: Passes; R-Value = 4.8 per inch at 75°F •ASTM C518 Thermal Resistance: R-Value of Elite 1.5 (1 1⁄2") = 7.2ASTM E84, UL723, ULC S102.2, UL R14514, ASTM E136, ASTM C518 ASTM C518. ASTM E-84, UL-723, ULC S-102.2, UL R-14514, ASTM E-136, ASTM C-518. ASTM E 84, UL 723, ULC S 102.2, UL R 14514, ASTM E 136, ASTM C 518.tdsfirestop
UnifraxUnifrax FyreWrap® Elite® Blanket Insulation•ASTM E84, UL 723, ULC S102.2 – UL File No. R14514 - Flame Spread/Smoke Developed Rating: Unfaced Blanket Zero/Zero, Encapsulated: <25/<50 •ASTM E136 Non-Combustibility Test: Passes •ASTM C518 Durability Test: Passes; R-Value = 4.8 per inch at 75°F •ASTM C518 Thermal Resistance: R-Value of Elite 1.5 (1 1⁄2") = 7.2ASTM E84, UL723, ULC S102.2, UL R14514, ASTM E136, ASTM C518 ASTM C518. ASTM E-84, UL-723, ULC S-102.2, UL R-14514, ASTM E-136, ASTM C-518. ASTM E 84, UL 723, ULC S 102.2, UL R 14514, ASTM E 136, ASTM C 518.sdsfirestop
3MVenture 1520CW Cold Weather Foil Insulation TapeUL723 Classified (5/10 Flame/Smoke Rating) UL file # R10984, ULC S102 Classification (10/0 Flame/Smoke Rating) ULC file # R10984, U.S. Coast Guard Approved (CGA # 164.112/63/0), BS476 parts 6 & 7 class 1, IMO Resolution A653(16), IMO Resolution MSC 61(67) Annex 1 Part 5 and Annex 2 IMO Resolution MSC 61(67) Annex 1 Part 2 and Annex 2, Specifically designed for cold weather conditions, Product Thickness (excluding liner) Typical Value: 3.3 mils, (Metric): 0.08 mm PSTC-133, Tensile Strength 21 lb/in, (Metric): 94.9 N/25 mm PSTC-131, Elongation 4%, (Metric): 4 % PSTC-131, Service Temperature -40 to 250 °F, (Metric): -40 to 121 °CUL723, ULC S102, BS476, A653, PSTC133, PSTC131. UL 723, ULC S 102, BS 476, A 653, PSTC 133, PSTC 131. UL-723, ULC S-102, BS-476, A-653, PSTC-133, PSTC-131.tdstapes
3MVenture 1520CW Cold Weather Foil Insulation TapeUL723 Classified (5/10 Flame/Smoke Rating) UL file # R10984, ULC S102 Classification (10/0 Flame/Smoke Rating) ULC file # R10984, U.S. Coast Guard Approved (CGA # 164.112/63/0), BS476 parts 6 & 7 class 1, IMO Resolution A653(16), IMO Resolution MSC 61(67) Annex 1 Part 5 and Annex 2 IMO Resolution MSC 61(67) Annex 1 Part 2 and Annex 2, Specifically designed for cold weather conditions, Product Thickness (excluding liner) Typical Value: 3.3 mils, (Metric): 0.08 mm PSTC-133, Tensile Strength 21 lb/in, (Metric): 94.9 N/25 mm PSTC-131, Elongation 4%, (Metric): 4 % PSTC-131, Service Temperature -40 to 250 °F, (Metric): -40 to 121 °CUL723, ULC S102, BS476, A653, PSTC133, PSTC131. UL 723, ULC S 102, BS 476, A 653, PSTC 133, PSTC 131. UL-723, ULC S-102, BS-476, A-653, PSTC-133, PSTC-131.sdstapes
3MVenture Tape 1525CW Cold Weather FSK Insulation TapeUL723 Classified (5/10 Flame/Smoke Rating) UL file # R10984, FSK facing meets ASTM C1136, type II and IV, Tri-directionally reinforced 2 x 3 squares per inch fiberglass scrim, UL listed FSK lamination, High performance insulation tape is ideal for use as a vapor seal for reinforced fiberglass or mineral wool thermal insulation, Venture CW® cold weather solvent acrylic adhesive performs well over a wide temperature range, Product Thickness (excluding liner) Typical Value: 9.5 mils, (Metric): 0.24 mm PSTC-133, Tensile Strength 40 lb/in, (Metric): 108.8 N/25 mm PSTC-131, Elongation 2%, (Metric): 2 % PSTC-131, Service Temperature -40 to 240 °F, (Metric): -40 to 116 °CASTM C1136, ASTM E96, ASTM C 1136, ASTM E 96, ASTM C-1136, ASTM E-96tdstapes
3MVenture Tape 1525CW Cold Weather FSK Insulation TapeUL723 Classified (5/10 Flame/Smoke Rating) UL file # R10984, FSK facing meets ASTM C1136, type II and IV, Tri-directionally reinforced 2 x 3 squares per inch fiberglass scrim, UL listed FSK lamination, High performance insulation tape is ideal for use as a vapor seal for reinforced fiberglass or mineral wool thermal insulation, Venture CW® cold weather solvent acrylic adhesive performs well over a wide temperature range, Product Thickness (excluding liner) Typical Value: 9.5 mils, (Metric): 0.24 mm PSTC-133, Tensile Strength 40 lb/in, (Metric): 108.8 N/25 mm PSTC-131, Elongation 2%, (Metric): 2 % PSTC-131, Service Temperature -40 to 240 °F, (Metric): -40 to 116 °CASTM C1136, ASTM E96, ASTM C 1136, ASTM E 96, ASTM C-1136, ASTM E-96sdstapes
3MVenture Tape 1540CW Cold Weather ASJ Insulation TapeUL723 Classified (0/5 Flame/Smoke Rating) UL file # R10984, Facing used meets ASTM C1136, Type I, II, III, IV, Specifically designed for cold weather; also excels in high heat and humidity conditions, Tri-directionally reinforced 4 x 4 squares per inch fiberglass scrim, UL listed laminate, High performance insulation tape is ideal for use as a vapor seal for on ASJ faced fiberglass duct board and pipe insulation, In stock product available for immediate delivery, Product Thickness (excluding liner) Typical Value: 10.8 mils, (Metric): 0.27 mm PSTC-133, Tensile Strength 55 lb/in, (Metric): 248.6 N/25 mm PSTC-131, Elongation 6%, (Metric): 6% PSTC-131, Service Temperature -40 to 240 °F, (Metric): -40 to 116 °CASTM C1136, ASTM E96, ASTM E408, ASTM C 1136, ASTM E 96, ASTM E 408, ASTM C-1136, ASTM E-96, ASTM E-408tdstapes
3MVenture Tape 1540CW Cold Weather ASJ Insulation TapeUL723 Classified (0/5 Flame/Smoke Rating) UL file # R10984, Facing used meets ASTM C1136, Type I, II, III, IV, Specifically designed for cold weather; also excels in high heat and humidity conditions, Tri-directionally reinforced 4 x 4 squares per inch fiberglass scrim, UL listed laminate, High performance insulation tape is ideal for use as a vapor seal for on ASJ faced fiberglass duct board and pipe insulation, In stock product available for immediate delivery, Product Thickness (excluding liner) Typical Value: 10.8 mils, (Metric): 0.27 mm PSTC-133, Tensile Strength 55 lb/in, (Metric): 248.6 N/25 mm PSTC-131, Elongation 6%, (Metric): 6% PSTC-131, Service Temperature -40 to 240 °F, (Metric): -40 to 116 °CASTM C1136, ASTM E96, ASTM E408, ASTM C 1136, ASTM E 96, ASTM E 408, ASTM C-1136, ASTM E-96, ASTM E-408sdstapes
3MVenture Tape 1581A-CW Duct Board TapeUL File # MH16587, meets requirements of UL181A-P (2 ½” minimum width) and UL181B-FX (1 7/8” minimum width), High performance duct closure tape is specifically designed for use as a vapor seal on reinforced fiberglass duct board, High performance solvent acrylic adhesive performs well over a wide temperature range, Hand tearable allows for easy installation, Also excels in high heat and humidity conditions, In stock product available for immediate delivery, Product Thickness (excluding liner) Typical Value: 4.0 mils, (Metric): 0.10 mm PSTC-133, Tensile Strength 27 lb/in, (Metric): 122.0 N/25 mm PSTC-131, Elongation 10%, (Metric): 10% PSTC-131, Service Temperature -40 to 300 °F, (Metric): -40 to 149 °CUL MH-16587, UL181A-P, UL181B-FX, PSTC-133, PSTC-131, PSTC-131. UL MH16587, UL181A-P, UL181B FX, PSTC133, PSTC131, PSTC131. UL MH 16587, UL 181A P, UL 181B FX, PSTC 133, PSTC 131, PSTC 131.tdstapes
3MVenture Tape 1581A-CW Duct Board TapeUL File # MH16587, meets requirements of UL181A-P (2 ½” minimum width) and UL181B-FX (1 7/8” minimum width), High performance duct closure tape is specifically designed for use as a vapor seal on reinforced fiberglass duct board, High performance solvent acrylic adhesive performs well over a wide temperature range, Hand tearable allows for easy installation, Also excels in high heat and humidity conditions, In stock product available for immediate delivery, Product Thickness (excluding liner) Typical Value: 4.0 mils, (Metric): 0.10 mm PSTC-133, Tensile Strength 27 lb/in, (Metric): 122.0 N/25 mm PSTC-131, Elongation 10%, (Metric): 10% PSTC-131, Service Temperature -40 to 300 °F, (Metric): -40 to 149 °CUL MH-16587, UL181A-P, UL181B-FX, PSTC-133, PSTC-131, PSTC-131. UL MH16587, UL181A-P, UL181B FX, PSTC133, PSTC131, PSTC131. UL MH 16587, UL 181A P, UL 181B FX, PSTC 133, PSTC 131, PSTC 131.sdstapes
3MVenture Tape VentureClad 1577CW Insulation CladdingPSTC-133, PSTC-101, PSTC-107, PSTC-131, ASTM D1000, ASTM C1371, ASTM E96, UL723 Classified (10/20 Flame/Smoke Rating) UL file # R10984, U.S. Coast Guard Approved (CGA # 164.112/63/0), ULC S102 Classification (25/25 Flame/Smoke Rating) ULC file # R10984, Japan Building Standard Law Article 2 Clause 9, Meets requirements of GSA facilities standard PBS 100, Listed as a cladding option for 3M™ Interam™ Endothermic Mat E-5A-4 (system meets UL 1709 standards - UL design number BYBU.XR202), Zero permeability, absolute vapor barrier for insulation cladding and jacketing applications, High puncture and tear resistance, Cuts and installs easily on-site, no special tools required, Product Thickness Flat (excluding liner) Typical Value: 7.0 mils, (Metric): 0.18 mm PSTC-133, Tensile Strength 70 lb/in, (Metric): 316.5 N/25 mm PSTC-131, Elongation 85%, (Metric): 85% PSTC-131, Service Temperature -94 to 300°F, (Metric): -70 to 149 °CASTM D1000, ASTM C1371, ASTM E96, ASTM D 1000, ASTM C 1371, ASTM E 96, ASTM D-1000, ASTM C-1371, ASTM E-96tdscladding
3MVenture Tape VentureClad 1577CW Insulation CladdingPSTC-133, PSTC-101, PSTC-107, PSTC-131, ASTM D1000, ASTM C1371, ASTM E96, UL723 Classified (10/20 Flame/Smoke Rating) UL file # R10984, U.S. Coast Guard Approved (CGA # 164.112/63/0), ULC S102 Classification (25/25 Flame/Smoke Rating) ULC file # R10984, Japan Building Standard Law Article 2 Clause 9, Meets requirements of GSA facilities standard PBS 100, Listed as a cladding option for 3M™ Interam™ Endothermic Mat E-5A-4 (system meets UL 1709 standards - UL design number BYBU.XR202), Zero permeability, absolute vapor barrier for insulation cladding and jacketing applications, High puncture and tear resistance, Cuts and installs easily on-site, no special tools required, Product Thickness Flat (excluding liner) Typical Value: 7.0 mils, (Metric): 0.18 mm PSTC-133, Tensile Strength 70 lb/in, (Metric): 316.5 N/25 mm PSTC-131, Elongation 85%, (Metric): 85% PSTC-131, Service Temperature -94 to 300°F, (Metric): -70 to 149 °CASTM D1000, ASTM C1371, ASTM E96, ASTM D 1000, ASTM C 1371, ASTM E 96, ASTM D-1000, ASTM C-1371, ASTM E-96sdscladding
3MVenture Tape VentureClad Plus 1579CW Insulation Cladding PSTC-133, PSTC-101, PSTC-107, PSTC-131, ASTM D1000, ASTM C1371, ASTM E96, ASTM E84 (25/20 Flame/Smoke Rating), U.S. Coast Guard Approved (164.112/1121/WCL MED0315TE), Zero permeability, absolute vapor barrier for insulation cladding and jacketing applications, High puncture and tear resistance, Cuts and installs easily on-site, no special tools required, Bonds and seals even in cold temperatures, Meets CINI 3.3 – 12 requirement, Japan Building Standard Law Article 2 Clause 9, In stock product available for immediate delivery, Product Thickness Flat (excluding liner) Typical Value: 17.5 mils, (Metric): 0.45 mm PSTC-133, Tensile Strength 187 lb/in, (Metric): 830. N/25 mm PSTC-131, Elongation 35%, (Metric): 35% PSTC-131, Service Temperature -94 to 248 °F, (Metric): -70 to 120 °CASTM D1000, ASTM C1371, ASTM E96, ASTM E84, ASTM D 1000, ASTM C 1371, ASTM E 96, ASTM E 84, ASTM D-1000, ASTM C-1371, ASTM E-96, ASTM E-84tdscladding
3MVenture Tape VentureClad Plus 1579CW Insulation CladdingPSTC-133, PSTC-101, PSTC-107, PSTC-131, ASTM D1000, ASTM C1371, ASTM E96, ASTM E84 (25/20 Flame/Smoke Rating), U.S. Coast Guard Approved (164.112/1121/WCL MED0315TE), Zero permeability, absolute vapor barrier for insulation cladding and jacketing applications, High puncture and tear resistance, Cuts and installs easily on-site, no special tools required, Bonds and seals even in cold temperatures, Meets CINI 3.3 – 12 requirement, Japan Building Standard Law Article 2 Clause 9, In stock product available for immediate delivery, Product Thickness Flat (excluding liner) Typical Value: 17.5 mils, (Metric): 0.45 mm PSTC-133, Tensile Strength 187 lb/in, (Metric): 830. N/25 mm PSTC-131, Elongation 35%, (Metric): 35% PSTC-131, Service Temperature -94 to 248 °F, (Metric): -70 to 120 °CASTM D1000, ASTM C1371, ASTM E96, ASTM E84, ASTM D 1000, ASTM C 1371, ASTM E 96, ASTM E 84, ASTM D-1000, ASTM C-1371, ASTM E-96, ASTM E-84sdscladding